1 Inductive sensor NJ2-D-US-1.025-V12


General specifications. Switching element function. NO contact. Rated operating distance sn. 2 mm. Installation flush. Output polarity. AC/DC. NO. Assured ...

Inductive sensor

NJ2-D-US-1.025-V12 Dimensions

LEDs

Ø48 35

2x Ø6.5

38 1/2"-20 UNF

Ø25

Model Number NJ2-D-US-1.025-V12

26.2

34.2

Cylinder Position Switch 11

Features • • • •

"X"

2-wire AC/DC Weld Immune Sensing range 2 mm 3000 psi rating

Ø12.7

Connection 2 AC/DC 3 1

Pinout

1

Release date: 2012-11-22 10:01

Date of issue: 2012-11-22 906579_eng.xml

2

3

Wire colors 1 2 3

GN (green) RD/BK (red/black) RD/WH (red/white)

Technical Data General specifications Switching element function Rated operating distance Installation Output polarity Assured operating distance Reduction factor rAl Reduction factor r304 Nominal ratings Operating voltage Switching frequency Hysteresis Reverse polarity protection Short-circuit protection Voltage drop Momentary current (20 ms, 0.1 Hz) Operating current Off-state current Mag. Field strength, AC fields Mag. Field strength, DC fields Limit data Operating pressure dynamically Indicators/operating means LED green LED red LED red/green Standard conformity Standards Ambient conditions Ambient temperature Mechanical specifications Connection type Protection degree Material Note Approvals and certificates

Accessories V12-G-YE2M-PVC

UL approval CSA approval

sn sa

UB f H

Ud IL Ir

NO contact 2 mm flush AC/DC NO 0 ... 1.62 mm 0.4 0.85 20 ... 250 V AC/DC 0 ... 20 Hz 10 ... 20 % 15 typ. yes yes ≤7V ≤3A 8 ... 300 mA < 1.7 mA 250 mT 100 mT 3000 psi Power on Output status Short circuit/overload indication EN 60947-5-2 -25 ... 70 °C (-13 ... 158 °F) Device connector 1/2"-20 UN , 3-pin IP67 Housing: zinc Probe: aluminum X = 1.025 in (26 mm) cULus Listed, General Purpose cCSAus Listed, General Purpose

Connecting cable, 1/2" - 20 UNF, 3-pin, PVC cable

V12-W-YE2M-PVC Connecting cable, 1/2" - 20 UNF, 3-pin, PVC cable

SPACER 0.160 TO 0.375 : X.XXX" Spacer for cylinder switches

SPACER 0.380 TO 0.875 : X.XXX" Spacer for cylinder switches

Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com [email protected]

Germany: +49 621 776-4411 [email protected]

Copyright Pepperl+Fuchs Singapore: +65 6779 9091 [email protected]

1

Inductive sensor NPT Type Mounting Holes: 1000 and 3000 psi NPT Types: Mounting hole screw thread shall be 1/4" - 20. Minimum thread engagement depth is 0.250" (6.35 mm) Hole spacing is 35 mm center to center.

Sensor through-hole

NJ2-D-US-1.025-V12

Mounting hole (x2)

Mounting hole spacing

Cylinder End-Cap Overhead View

Mounting Screws: Standard 1000 and 3000 psi models use two, self-locking 1/4"- 20 socket head cap screws (provided). Recommended tightening torque: 150 in lb (16.95 N-m).

Release date: 2012-11-22 10:01 Date of issue: 2012-11-22

906579_eng.xml

Important: When using spacers, make certain to maintain the 0.250" (6.35 mm) minimum mounting screw thread engagement.

2

Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com [email protected]

Germany: +49 621 776-4411 [email protected]

Copyright Pepperl+Fuchs Singapore: +65 6779 9091 [email protected]

Recommend Documents
General specifications. Switching element function. NAMUR, NC. Rated operating distance sn. 5 mm. Installation not embeddable. Assured operating distance sa. 0 ... 4.05 mm. Reduction factor rAl. 0.25. Reduction factor rCu. 0.2. Reduction factor rV2A.

Oct 12, 2012 - s Stainless steel, 1.4305 s DC 3-wire, 10…30 VDC s NO contact, NPN output s M12 x 1 connector. Wiring diagram. Functional principle. The inductive all-metal switches operate on the basis of the electromagnetic pulse method. Unlike st

Conserning induc- tive sensors, this field is generated by an. LC resonant circuit with a ferrite core coil. ... Ambient temperature. -25…+ 70 °C. Operating voltage. 10… 30VDC. Residual ripple р 10 % Uss. DC rated operational current р 150 mA.

KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ[email protected] ñwww.turck.com. Inductive sensor. Bi5-M18-Y1X-H1141. ○ ATEX category II 1 G, Ex zone 0. ○ ATEX category II 1 D, Ex zone 20. ○ SIL2 a

Jun 10, 2016 - NO contact. □ Terminal chamber. Wiring Diagram. Functional principle. Inductive sensors detect metal objects con- tactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. In

Short-circuit protection yes/ Cyclic. Voltage drop at Ie ð 1.8 V. Wire breakage/Reverse polarity protection yes/ Complete. Output function. 3-wire, NO contact, PNP.

Jul 25, 2012 - KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com. Type.

n: • 25 .11.2008. Hans Turck GmbH & Co.KG сD-45472 Mьlheim an der Ruhr сWitzlebenstraЯe 7 сTel. 0208 4952-0 сFax 0208 4952-264 с[email protected] сwww.turck. ... factor 1 for all metals. ○ degree of protection IP68. ○ magnetic field immune

Functional principle. Inductive sensors are designed for wear-free and non-contact detection of metal objects. For this purpose they use a high-frequency electro-magnetic AC field that interacts with the target. Inductive ring sensors generate this f

Dec 17, 2015 - NO contact. □ Cable connection. Wiring diagram. Functional principle. Inductive sensors detect metal objects con- tactless and wear-free. For this, they use a high-frequency electromagnetic AC field that interacts with the target. In