• Use only one (1) Vizia™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will turn the light on at the brightness level selected at the dimmer.

• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformeroperated appliance.

• Recommended minimum wall box depth is 2-1/2". • Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).

• For Hi-lume® or Eco-10™ (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications.

• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.

• Vizia™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ devices for multi-location switching.

• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

Tools needed to install your Remote: Slotted/Phillips Screwdriver Pliers Cutters

Step 4b 3-Way Wiring with Coordinating Remote (no LEDs) Application:

Step 2 cont’d

Electrical Tape Pencil Ruler

Strip Gage (measure bare wire here or use gage on back of the dimmer)

Changing the color of your Remote:

5/8" (1.6 cm)

Your Remote includes three color options. The Remote ships with the White frame attached. To change color of frame, proceed as follows:

NOTE: Use check boxes

Step 1

when Steps are completed.

WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!

���

��

���

��

���

��

���

��

���

��

���

��

���

��

���

��

���

��

���

��

���

��

���

��

• Make sure that the ends of the wires from the wall box are straight (cut if necessary).

Step 4a

Matching Remote

NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician.

Terminal Screw marked Black (BK)

BK

WH

Dimmer Additional Neutral Wire 4 BK

1

2

4

Terminal Screw marked Yellow/Red (YL/RD)

YL/RD RD

3

3 YL/RD RD

1

5

5

Matching Remote (no LEDs) Dimmer

2

1

1

3

2 4 5 6

3 4 5

3-Way 1. Line or Load (See important instruction below) 2. Neutral 3. Ground 4. First Traveler – note color 5. Second Traveler – note color NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot.

4-Way 1. First Traveler – note color 2. Second Traveler – tagged 3. Neutral 4. Ground 5. Third Traveler – note color 6. Fourth Traveler – tagged NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot.

IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. For 4-Way applications, note that the old switch being removed will have 4 screws plus a ground screw. Tag the two same color insulated wires with electrical tape.

Step 3

Hot (Black)

WH

BK Green Ground

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to terminal screw marked "BK" or Black dimmer lead. • Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" (note wire color). This traveler from the remote must go to terminal screw marked "YL/RD" or Yellow/Red control lead. • Line Neutral wall box to remote terminal screw marked "WH".

3

3

4

4

YL/RD RD

5

5

Coordinating Remote (no LEDs) not used

BK

WH

Black RD

YL/RD

Hot (Black)

BK

Green Ground

Green Ground

Load

Dimmer

WIRING DIMMER (wall box with Load connection): YL/RD

RD

Line 120VAC, 60Hz

White

WIRING DIMMER:

Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "BK" or Black dimmer lead. • First Traveler wall box wire to terminal screw marked "RD" or Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red dimmer lead. • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".

Black

YL/RD

BK

RD

YL/RD

Terminal Screw marked White (WH)

Wiring Dimmer (wall box with Load connection):

Additional Neutral Wire

Black

2 BK

WH

Terminal Screw marked Black (BK)

1

2

White

4 YL/RD RD

4

3

1

Red

5

3

5

Terminal Screw marked Yellow/Red (YL/RD)

Yellow/Red

Matching Remote (w/LEDs) Control Hot (Black)

Line 120VAC, 60Hz

WH

BK Green Ground

YL/RD

White

Black

Green Ground

Red

Black Yellow/Red

Load White

Neutral (White)

Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from control to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to First Traveler (note color as above). • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Remove White insulating label from terminal screw marked "WH". • Line Neutral wall box wire to terminal screw marked "WH". • Proceed to Step 6.

Step 5a

WH

4-Way Wiring with Matching Remote (w/LEDs) Application:

BK

YL/RD RD

WH

Ground

Line 120VAC, 60Hz

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted. Terminal Screw marked White (WH)

BK

Black

WH

1

1

YL/RD RD

2 Green

3

4

5

3

Yellow/Red

WH

BK

not used Green Ground

Black RD

not used

Load

4

5

Coordinating Remote (no LEDs)

YL/RD

Control

White

Black

Hot (Black)

Green Ground

Red

Yellow/Red Line 120VAC, 60Hz

White Neutral (White)

WIRING CONTROL:

RD

YL/RD

Load

NOTE: The dimmer must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).

WIRING MATCHING REMOTE (4-Way wall box with Line Hot connection):

Red

Terminal Screw marked Yellow/Red (YL/RD)

Ground

YL/RD

White

White

2

YL/RD

YL/RD RD

Neutral (White)

Control

Coordinating Remote

BK

YL/RD RD

3-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:

Step 4d

WIRING COORDINATING REMOTE:

Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is Load 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. White • Load wall box wire identified (tagged) when removing old switch to Neutral (White) terminal screw marked "BK". • First Traveler wall box wire (note color as above) to terminal screw NOTE: The dimmer must be installed in a wall box that has a Load marked "RD". This traveler from the remote must go to the terminal connection. The matching remote must be installed in a wall box screw on the dimmer marked "RD" or Red dimmer lead. with a Line Hot connection and a Neutral connection. A Neutral wire • Second Traveler wall box wire (note color as above) to terminal to the matching remote needs to be added as shown. screw marked "YL/RD". This traveler from the remote must go to If you are unsure about any part of these instructions, consult a the terminal screw on the dimmer marked "YL/RD" or Yellow/Red qualified electrician. dimmer lead. NOTE: Maximum wire length from dimmer to all installed remotes cannot • Remote terminal screw marked "WH" should have White insulation exceed 300 ft. label affixed. Wiring Matching Remote (wall box with Line Hot connection): NOTE: If insulating label is not affixed to terminal screw marked Connect wires per WIRING DIAGRAM as follows: "WH", use electrical tape to cover. • Green or bare copper wire in wall box to Green terminal screw. • Proceed to Step 6. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler to dimmer terminal screw marked “BK” Step 4c 3-Way Wiring with Matching Remote (w/ LEDs) for Controls with Neutral Connection or the Black dimmer lead. Application: • Second Traveler wall box wire from dimmer to remote terminal screw NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan marked “YL/RD” (note wire color). This traveler from the remote Speed and Electronic Switch installations only. must go to the terminal screw on the dimmer marked “YL/RD” or the NOTE: Dimmer is depicted. Yellow/Red dimmer lead. Matching Remote Control • Line Neutral wall box to remote terminal screw marked “WH”. Green Line 120VAC, 60Hz

Step 4d cont’d WIRING COORDINATING REMOTE:

NOTE: Incandescent and Magnetic Low-Voltage Connect wires per WIRING DIAGRAM as follows: installations only. NOTE: Screw terminal dimmer • Green or bare copper wire in wall box to Green terminal screw or depicted. Green control lead. • Load wall box wire identified Dimmer Matching Remote Matching Remote (tagged) when removing old (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall box from Step 2) switch to terminal screw marked Terminal Terminal Additional Screw marked Screw marked Additional "RD" or Red control lead. Neutral Wire White (WH) White (WH) Neutral Wire • First Traveler Line Hot to terminal 4 2 screw marked "BK" or Black 3 1 Terminal Terminal 1 Screw marked Screw marked 2 control lead. Black (BK) Black (BK) 5 4 3 • Remove Red insulating label from 4 3 1 Terminal 2 terminal screw marked "YL/RD" or ScrewTerminal marked Screw marked 5 5 Yellow/Red Yellow/Red Yellow/Red control lead. 6 (YL/RD) (YL/RD) • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD" or Yellow/ Red control lead. This traveler from the control must go to the Matching Remote Matching Remote terminal screw on the remote marked "YL/RD". Dimmer (w/LEDs) (w/LEDs) • Line neutral wall box wire to terminal screw marked "WH" or White control lead. Hot (Black) BK WH WH BK BK Green Green • Proceed to Step 6. Green Ground Black

BK Green Ground

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. Preparing and connecting wires: • Load wall box wire identified (tagged) when removing old switch to This remote can be wired using side wire terminal screws dimmer terminal screw marked “RD” or the Red dimmer lead. or through backwire openings. Choose appropriate wire • First Traveler Line Hot to dimmer terminal screw marked “BK” or the stripping specifications accordingly. Black dimmer lead. • Remove Red insulating label from terminal screw marked “YL/RD” or Yellow/Red dimmer lead. • Second Traveler wall box wire (note color as above) to dimmer terminal screw marked “YL/RD” or the Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. Cut • Proceed to Step 6.

(if necessary)

WIRING MATCHING REMOTE (wall box with Line Hot connection):

2

Neutral (White)

3-Way Wiring with Matching Remote (w/LEDs) Application:

Terminal Screw marked White (WH)

1

BK

2

• Remove insulation from each wire in the wall box as shown.

NOTE: Incandescent and Magnetic Low-Voltage installations only. NOTE: Screw terminal dimmer depicted.

Identifying your wiring application (most common):

1

YL/RD RD

5/8" (1.6 cm)

2

Step 2

WH

BK

Terminal Screw marked Red (RD)

Back Wire (either hole may be used) Back wire openings use #14-12 AWG solid copper wire only.

INSTALLING YOUR REMOTE

Terminal Screw marked Black (BK) Terminal Screw marked Yellow/Red (YL/RD)

Line up tabs and press in side to attach

Dimmer

Coordinating Remote

Side Wire Connection Side wire terminals accept #14 AWG solid Bl copper wire only. Strip Gage (measure bare wire here or use gage on back of the dimmer)

Push in side at tab to release

NOTE: Incandescent and Magnetic Low-Voltage installations only. NOTE: Screw terminal dimmer depicted.

NOTE: The control must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m).

Connect wires per WIRING DIAGRAM as follows: NOTE: The control must be installed in a wall box that has a Line Hot Connection. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green control lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked "BK" or Black control lead. • First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note wire color). • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red control lead (note wire color). This traveler from the control must go to the terminal screw on the remote marked "YL/RD". • Line Neutral wall box wire to terminal screw marked "WH" or White control lead.

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire from dimmer in the 3-way box to remote terminal screw marked "BK" in the 4-way box, and to the terminal screw marked "BK" of the remaining remote in the 3-way box. • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from dimmer in the 3-way box to remote terminal screw marked "YL/RD" in the 4-way box, and to the terminal screw marked "YL/RD" of the remaining remote in the 3-way box (note wire colors). This traveler from the remotes must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. • Line Neutral wall box wire to remote terminal screw marked "WH".

WIRING MATCHING REMOTE (3-Way wall box with Line Hot connection):

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler dimmer terminal screw marked "BK" or the Black dimmer lead. • Second Traveler wall box wire from dimmer to remote terminal screw marked "YL/RD" (note wire color as above). This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. • Line Neutral wall box wire to remote terminal screw marked "WH".

Step 5a cont’d 4-Way Wiring with Matching Remote (w/LEDs) Application:

4-Way Wiring with Matching Remote (w/LEDs) for Controls with Neutral Connection Application:

Step 5c

NOTE: Incandescent and Magnetic Low-Voltage installations only. NOTE: Screw terminal dimmer depicted.

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted.

WIRING DIMMER (3-Way wall box with Load connection):

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Load wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "RD" or the Red dimmer lead. • First Traveler Line Hot to dimmer terminal screw marked "BK" or the Black dimmer lead. • Remove Red insulating label from terminal screw marked "YL/RD" or the Yellow/ Red dimmer lead. • Second Traveler wall box wire (note color as above) to dimmer terminal screw marked "YL/RD" or the Yellow/Red dimmer lead. This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD". • Proceed to Step 6.

Step 5b

NOTE: Incandescent and Magnetic Low-Voltage installations only. NOTE: Screw terminal dimmer depicted. Coordinating Remote (3-Way Wall box from Step 2)

Coordinating Remote Dimmer (4-Way Box from Step 2) (3-Way Wall Box from Step 2)

Terminal Screw marked Red (RD)

BK

WH

Terminal Screw marked Black (BK)

1

Terminal Screw marked Red (RD)

BK

YL/RD RD

1

BK

3

4

3 4

1

YL/RD RD

5

2

WH

BK

4

Terminal Screw marked Yellow/Red (YL/RD)

3

YL/RD RD

5

Black

4

3

1

2

White

4

Terminal Screw marked Yellow/Red (YL/RD)

5

WH

BK

Terminal Screw marked Black (BK)

1

Green

2

YL/RD RD

3

1

Red

6

5 Yellow/Red

Matching Remote Matching Remote (w/LEDs) (w/LEDs) WH

Line 120VAC, 60Hz

Green Ground

Green Ground

YL/RD

YL/RD

Green Ground

Black Yellow/Red

Red

5

Load White

WIRING MATCHING REMOTE (4-Way wall box with Line Hot connection): Coordinating Remote (no LEDs) not used

Black

Load

WH

Coordinating Remote (no LEDs)

BK

not used

WH

Green Ground

RD

YL/RD

not used

BK

Green Ground

RD

Dimmer

YL/RD

Hot (Black)

BK Green Ground

RD

YL/RD

Line 120VAC, 60Hz

White Neutral (White)

WIRING COORDINATING REMOTE (4-Way box):

Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire (note wire colors) to terminal screw marked "RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "RD" or Red dimmer lead, and to the terminal screw marked "RD" of the remaining remote in the 3-way box. • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note wire colors) to terminal screw marked "YL/RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead, and to the terminal screw marked "YL/RD" of the remaining remote in the 3-way box. • Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. Remote terminal screw marked "BK" is not used. Use electrical tape to cover.

WIRING DIMMER (3-Way box):

Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to dimmer terminal screw marked "BK" or Black dimmer lead. • First Traveler wall box wire to dimmer terminal screw marked "RD" or Red dimmer lead (note wire color as above). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red dimmer lead. • Second Traveler wall box wire to dimmer terminal screw marked "YL/RD" or Yellow/ Red dimmer lead (note wire color as above). This traveler from the dimmer must go to the terminal screw on the remote marked "YL/RD".

WIRING COORDINATING REMOTE (3-Way box):

Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to terminal screw marked "BK". • First Traveler wall box wire (note color as above) to terminal screw marked "RD". This traveler from the remote must go to the terminal screw on the dimmer marked "RD" or the Red dimmer lead. • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw on the dimmer marked "YL/RD" or the Yellow/Red dimmer lead. • Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. • Proceed to Step 6.

WIRING COORDINATING REMOTE (4-Way box):

Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Connect First Traveler wall box wire to Third Traveler wall box wire (note wire colors) to terminal screw marked "RD" of remote in 4-way box, and to terminal screw marked "RD" of the remaining remote in 3-way box. • Connect Second Traveler and Fourth Traveler wall box wire (note wire colors) to terminal screw marked "YL/RD" of remote in 4-way box, and to terminal screw marked "YL/RD" of the remaining remote in 3-way box. This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Remove White insulating label from terminal screw marked "WH". • Line Neutral wall box wire to terminal screw marked "WH".

WIRING CONTROL (3-Way box):

Black

White

BK

WH

BK

Control

NOTE: The control must be installed in a wall box that has a Load connection. The matching remote must be installed in a wall box with a Line Hot connection and a Neutral connection. A Neutral wire to the matching remote needs to be added as shown. If you are unsure about any part of these instructions, consult a qualified electrician. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m).

4 YL/RD RD

Terminal Screw marked Yellow/Red (YL/RD)

Terminal Screw marked Yellow/Red (YL/RD)

Terminal Screw marked Black (BK)

Additional Neutral Wire

Terminal Screw marked White (WH)

Additional Neutral Wire

2

3

2 6

5

Terminal Screw marked White (WH)

Matching Remote Control (4-Way Box from Step 2) (3-Way Wall Box from Step 2)

Neutral (White)

WH

2

Matching Remote (3-Way Wall box from Step 2)

Hot (Black)

4-Way Wiring with Coordinating Remote (no LEDs) Application:

Step 5d cont’d

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire to remote terminal screw marked "BK" in 4-way box, and to terminal screw marked "BK" of the remaining remote in 3-way box. • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from control in 3-way box to remote terminal screw marked "YL/RD" in 4-way box and to terminal screw marked "YL/RD" of the remaining remote in 3-way box (note wire colors). This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Line Neutral wall box wire to remote terminal screw marked "WH".

WIRING MATCHING REMOTE (3-Way wall box with Line Hot connection): Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and First Traveler wall box wire to control terminal screw marked "BK" or Black dimmer lead. • Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" (note wire color as above). This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red dimmer lead. • Line Neutral wall box wire to remote terminal screw marked "WH".

WIRING CONTROL (3-Way wall box with Load connection):

Connect wires per WIRING DIAGRAM as follows: NOTE: The control must be installed in a wall box that has a Line Hot connection. NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw or Green control lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to terminal screw marked "BK" or Black control lead. • First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note wire color as above). • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red control lead (note wire color as above). This traveler from the control must go to the terminal screw on the remote marked "YL/RD". • Line Neutral wall box wire to terminal screw marked "WH" or White control lead.

WIRING COORDINATING REMOTE (3-Way box):

Connect wires per WIRING DIAGRAM as follows: NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both screws. NOTE: Maximum wire length from control to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. • Load wall box wire identified (tagged) when removing old switch to First Traveler (note color as above). • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. • Remove White insulating label from terminal screw marked "WH". • Line Neutral wall box wire to terminal screw marked "WH". • Proceed to Step 6.

Coordinating Remote (4-Way Box from Step 2)

Terminal Screw marked Yellow/Red (YL/RD)

BK

WH

3

1

Terminal Screw marked Black (BK)

2

Terminal Screw marked Yellow/Red (YL/RD)

4

YL/RD RD

5

BK

WH

White

3

4 YL/RD RD

2

1

• Restore power at circuit breaker or fuse. • See applicable operation section to ensure dimmer or switch is functioning properly. If lights do not turn ON, refer to the TROUBLESHOOTING section.

Green

5

3

6

Red Yellow/Red

4

WH Black

not used

WH

Green Ground

RD

not used

Load

BK

Coordinating Remote (no LEDs)

YL/RD

BK

not used Green Ground

RD

not used

YL/RD

Control White

Green Ground

Red

Black

NOTE: The lights will turn ON at brightness set on dimmer’s DIM/BRIGHT bar. The lighting can be controlled from either the dimmer or the remote location. Push Pad (Default settings) LED Brightness DIM/BRIGHT Turn ON from OFF position: Tap – Lights turn ON to preset level. Display Bar Press and Hold – Lights turn ON to full bright. Turn OFF from ON position: Tap – Lights turn OFF. Press and Hold for 2 seconds – Lights remain ON for 10 seconds and then turn OFF. DIM/BRIGHT Bar BRIGHTEN: Press upper half of DIM/BRIGHT Bar – Lights brighten to desired level. DIM: Press lower half of DIM/BRIGHT Bar – Lights dim to desired level. If you continue to hold, the lights will DIM to minimum level and then turn OFF. Push Pad Locator If there is a power outage, when the power is restored Light the lights will return to the last setting before the power interruption.

VZ0SR Switch Remote Operation (Switch may be unlighted): NOTE: The lights will turn ON at brightness set on dimmer’s DIM/BRIGHT bar. The lighting can be controlled from either the dimmer or the remote location. Push Pad (Default settings) Turn ON from OFF position: Tap – Lights turn ON to preset level. Turn OFF from ON position: Tap – Lights turn OFF. If there is a power outage, when the power is restored the lights will return to the last setting before the power interruption.

For additional information, contact Leviton’s Techline at 1-800-824-3005 or visit Leviton’s website at www.leviton.com U.S. & Foreign Patents Pending Copyright© 2006 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved Eco-10™ (Eco Series) is a trademark and Hi-lume® is a registered trademark of Lutron Electronics Inc. FCC COMPLIANCE STATEMENT

5

Coordinating Remote (no LEDs)

VZ00R Dimmer Remote Operation (Dimmer may be unlighted):

• Lights Flickering - Lamp has a bad connection. - Wires not secured firmly under terminal screws of dimmer and/or remote. • Light does not turn ON and Locator LED does not turn ON - Circuit breaker or fuse has tripped. - Lamp is burned out. - Lamp Neutral connection is not wired. • Intermittent dimmer operation - Minimum load is under 40W. • Remote does not operate lights - Ensure that total wire length does not exceed 300 ft (90 m).

1 2

OPERATION CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners.

TROUBLESHOOTING

NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when mounting device.

Black Terminal Screw marked Black (BK)

Restore power at circuit breaker or fuse. Installation is complete.

Locator Light

Control (3-Way Wall Box from Step 2)

Terminal Screw marked White (WH)

Step 8 Restore Power:

Push Pad

NOTE: Electronic Low-Voltage, Mark 10™, Quiet Fan Speed and Electronic Switch installations only. NOTE: Dimmer is depicted.

Terminal Screw marked White (WH)

Installation may now be completed by tightening mounting screws into wall box. Attach wallplate.

• Position all wires to provide room in outlet wall box for device. • Ensure that the word "TOP" is facing up on the device strap. • Partially screw in mounting screws in wall box mounting hole.

4-Way Wiring with Coordinating Remote (no LEDs) for Controls with Neutral Connection Application:

Coordinating Remote (3-Way Wall box from Step 2)

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

Step 6 Testing your Remote prior to completely mounting in wall box:

Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Load wall box wire identified (tagged) when removing old switch to terminal screw marked "RD" or Red control lead. • First Traveler Line Hot to terminal screw marked "BK" or Black control lead. • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red control lead. • Second Traveler wall box wire (note color as above) to terminal screw marked "YL/RD" or Yellow/Red control lead. This traveler from the control must go to the terminal screw on the remote marked "YL/RD". • Line Neutral wall box wire to terminal screw marked "WH" or White control lead. • Proceed to Step 6.

Step 5d

Step 7 Dimmer Remote Mounting:

Hot (Black)

Yellow/Red Line 120VAC, 60Hz

White Neutral (White)

This equipment has been tested and found to comply with the limits for a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving Antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/tv technician for help.

PK-93393-10-00-2A

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FOLD SCHEME 16.5¨

Cat. No.

6

5

4

3

2

1

15.0¨ LEVITON INSTRUCTION SHEET/MANUAL SPECIFICATIONS PK-93393-10-00-2A Black

Helvetica

40 Lb. offset

Paper size: Overall size: 16.5" x 15" (printing spec) Final fold size: 2.75" X 3.75" (Locking fold)

Cat. No.

2.75¨

DOCUMENTATION N/A KKC

Cat. No. 1/24/06

3.75¨ Final Fold Size

Fold Line Panel Line #'s =

Fold Sequence