8000 SERIES. MANY DAILY ON/OFF. OPERATIONS PER DAY. DUTY CYCLE. 24 HOUR TIME SWITCH. Duty cycling. Ventilating fans. Pumping. Irrigation. Process control. Laboratory experiments. For one or multiple daily. ON/OFF operations . SCHEDULING: Minimum ON setting is. 15 minutes with minimum OFF setting at.

8000 SERIES

CONTACT RATINGS

SPECIFICATIONS

MANY DAILY ON/OFF OPERATIONS PER DAY DUTY CYCLE 24 HOUR TIME SWITCH

INPUT VOLTAGE: 120, 208-277VAC or 480VAC, 60Hz, varies by model. TIMING ACCURACY: Line frequency. TERMINAL RANGE: #8 - #14AWG.

ORDERING INFO ENCLOSURE TYPE

CATALOG NO.

UPC CODE

INPUT SUPPLY (VAC) 60Hz

OUTPUT CONTACTS

8001

70001

120

SPDT

8001-N

70025

120

SPDT

8001-NC

70009

120

SPDT

Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Noryl® Indoor/Outdoor NEMA 3R w/ clear Lexan® cover

8001-LC/WB

70010

120

SPDT

Mechanism and bracket

8001-O

70029

120

SPDT

8004

70002

208-277

SPDT

8001U

70003

480/120 Trans.

SPDT

NEW!

8001U-N

70014

480/120 Trans.

SPDT

NEW!

8001U-O

70011

480/120 Trans.

SPDT

Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Noryl® Indoor/Outdoor NEMA 3R Metal Indoor/Outdoor NEMA 3

DUTY CYCLE: Adjustable from 1⁄2, 1, 2, 3, 4, 6, 12, and 24 hours.

24 HOUR WITH 7 DAY OMIT 70005

120

SPDT

8007-O

70012

120

SPDT

8008

70006

208-277

SPDT

NEW!

8007U

70008

480/120 Trans.

SPDT

NEW!

8007U-0

70028

480/120 Trans.

SPDT

Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3 Metal Indoor NEMA 1 Metal Indoor NEMA 1 Metal Indoor/Outdoor NEMA 3

24 HOUR WITH 7 DAY OMIT & RESERVE POWER 8007L

70015

120

SPDT

8008L

70016

208-277

SPDT

Metal Indoor NEMA 1 Metal Indoor NEMA 1

24 HOUR WITH 14 DAY OMIT 8007V

70007

120

SPDT

Metal Indoor NEMA 1

SPDT

Metal Indoor NEMA 1

24 HOUR WITH 14 DAY OMIT & RESERVE POWER 8007VL Replacement Motor

TORK 37

120 or 240VAC 480VAC

20A 20A

Motor

120VAC

3/4 HP

OTHER MOUNTINGS: Intermatic® Adaptor Plate model #IAP allows 8001 & 8004 to fit into an Intermatic case.

WIRING DIAGRAMS

70017

120

M

ALL SPDT MODELS

C L

H

8007

SKIP-A-DAY: Some models include 7 day or 14 day wheel to omit selected days of the week.

ELECTROMECHANICAL CONTROLS

Resistive

ENCLOSURE: Lockable hasp. Type varies by model (see page 153 for enclosure dimensions).

8001-N

FEATURES

OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage.

CONTACT RATING

POWER CONSUMPTION: 3 watts, 5 watts for “L” models maximum.

For one or multiple daily ON/OFF operations.

SCHEDULING: Minimum ON setting is 15 minutes with minimum OFF setting at 15 minutes. Dial accommodates up to 96 captive tabs.

VOLTAGE

OPERATING TEMPERATURE: -40˚ to 165˚F (-40˚ to +74˚C).

APPLICATIONS Duty cycling Ventilating fans Pumping Irrigation Process control Laboratory experiments

TYPE

120VAC N

NC

NO 2

LOAD 2 CLOSED WITH TAB OUTWARD

LOAD 1 CLOSED WITH TAB INWARD

SPECIFICATION WRITER’S GUIDE The time switches shall be of duty cycle type, capable of programming at 15 minute intervals of the day. Scheduled tabs shall be captive on the dial, and shall be easily set by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the field. FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007 or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.

#101(120V) & #201 (208-277V). For “L” models #36 (120V) & #46 (208-277V)

A DIVISION OF NSi INDUSTRIES, LLC USA • 800.321.5847 • www.nsiindustries.com

TORK 38

Recommend Documents
Camden Door Controls offers the widest range of high quality, feature rich and affordable pneumatic 'Request to Exit' switches in the industry. All switches ...

OPTIONAL RESERVE POWER: “L” models keep dial on time up to 16 hours during power outage . INPUT VOLTAGE: 120, 208-277VAC or. 480VAC, 60Hz ...

Wood. Electrical. • .24 Amps at. 12 VDC/VAC. • .12 Amps at. 24 VDC/VAC .... For use with: Extended lip for 'knock-down' style frame installations. For use with ...

No cutting on frame required. Vertical adjustability to ... Strike body width decreased to 1-7/16" to increase frame compatibility. Five year limited warranty.

The devices are Underwriters. Laboratory (UL, USA and ULC, Canada) listed for Panic Exit Hardware or Fire Exit Hardware, and are certified to ANSI.

8000-AAB Series. The PumPac 8000 Series is used in centrifugal pumps, .... Reversing thrust on bearing B (15˚). P = YFA. P = Dynamic equivalent radial load.

These meters are designed for use with TSP or HSP transmitters. The meter can be used for either local or remote indication of the sensed variable. All meters of the ASP-500 series are zero suppressed - taut band - 100° flat arc movement type with a

BlackDiamond® 8800 series switches simplify enterprise, data center and service .... port and a range of QoS technologies that can prioritize and .... 128. 128. 128. 128. Layer 2 MAC FDB. 128k. 512k. 512k. 512k. 32k. 32k. 32k. 8k. 32k. 32k.

ENCLOSURE: Indoor NEMA 1 Metal with lockable hasp (see page ... Duty cycling. Ventilating fans ... DUTY CYCLE: Settings of 1⁄60 th of dial speed . CATALOG.

Includes the 801 and 801A faceplates in the box. Model 8000C includes a 801 and a 801A faceplate in the box. The 8000. Series is also available in a Complete. One Box. Solution. INT. EGR. A. T. ED. PR. ODUC. T. S. C. A. BINE. T LO. CK. S. AC. C. ES.