A-1 Series Injection Safety Valve

Report 13 Downloads 67 Views


A-1 Series Injection Safety Valve Applications

• Sweet to moderately corrosive environments from 40°F to 300° [4°C to 149°C]

Benefits

• Offers a versatile solution • • • • •

Provides an unobstructed flow path and reliable production Design is cost effective and easy to run Allows fewer potential leak paths Reduces problems associated with solids and scale deposition. Applies to a wide range of subsurface enviroments

Features • • • • • • • •

Unlimited setting depths Straight-through bore Designed in accordance with API 14A criteria Compact design Minimum number of seals Field-proven flapper and seat with metal-to-metal sealing Optimal geometry and clearance between sliding components Adjustable flow rates and closing pressures

The Camco* type A-1 Injection Safety Valve is designed to prevent wells from flowing back or blowing out in the event of an emergency. The A-1 will open at preset injection flow rates†, have unlimited setting depth and, are suitable for severely corrosive environments. These valves are available to 10,000-psi [68,950-kPa] working pressure. The A-1 prolongs the life of the valve by protecting the flapper from erosive injection flow. The A-1 is available in a variety of materials and features an innovative and field-proven flapper closure system. This premium flapper mechanism has full, metal­-tometal sealing plus a secondary soft seat, and it meets a leakage­acceptance criterion that is substantially more stringent than API and ISO specifications. The A-1 Injection Safety Valve is “normally closed”, and open with dif­ferential pressure created by the injection flow. Operation The A-1 Series Injection Valve with the appropriate lock and equalizing sub†† are installed in a landing nipple in the tubing string using con­ventional slickline methods. Open The A-1 Series Injection Valve opens when injection flow reaches a predetermined rate. The spring-loaded flow tube holds the flapper open and out of the injection­stream flow path, providing an unobstructed flow bore through the inside diameter of the valve. Close The A-1 Series Injection Valve close when injection ceases.

A-1 series Open

Q1-0099

Copyright Tejas Research & Engineering, LLC 2015, All rights reserved 9185 Six Pines Dr., The Woodlands, TX 77380 Phone: 281 466 8700

14A-0032

www.tejasre.com [email protected]



A-1 Series Injection Safety Valve Engineering Data For A-Series Injection Safety Valves‡

Tubing OD in [mm]

Valve Type

Valve OD ‡ ‡ in [mm]

Max I.D. [in/mm]

Max Flow Area in2[mm2]

Working Pressure psi [kPa]

1.660 [42.2)

A-1

1.250 [31.8]

0.437 [11.1]

0.150 [96.8]

5,000 [34,400]

2.063 [52.4]

A-1

1.625 [41.3]

0.620 [15.7]

0.302 [194.8]

5,000 [34,400]

A-1H

1.750 [44.5]

0.563 [14.3]

0.249 [160.6]

10,000 [68,900]

A-1

1.797 [45.6]

0.750 [19.1]

0.442 [285.2]

A-1

1.848 [46.9]

0.750 [19.1]

0.442 [285.2]

A-1H

2.218 [56.4]

.957 [24.3]

0.718 [463.8]

A-1

2.235 [56.8]

1.235 [31.4]

1.198 [774.4]

2.375 [60.3]

5,000 [34,400]

2.875 [73.0]

10,000 [68,900]

5,000 [34,400] A-1

2.286 [58.1]

1.125 [28.6]

0.994 [641.3]

3.000 [76.2]

A-1

2.808 [71.3]

1.485 [37.7]

1.732 [1117.4]

3.500 [88.9]

A-1

2.808 [71.3]

1.548 [37.7]

1.808 [46.0]

4.000 [101.6]

A-1

3.781 [96.0]

2.125 [54.0]

3.547 [2288.4] 2.895 [1867.7]

4.500 [114.3]

A-1

3.733 [94.4]

2.110 [53.6]

3.497 [2256.1]

2.562 [65.1]

5.155 [3325.8]

5,000 [34,400]

3.625 [92.1]

10.321 [6658.7]

5,000 [34,400]

5,000 [34,400

6,000 [41,300]

4.500 [114.3] 5.500 [139.7]

A-1 4.515 [114.7]

6.000 [152.4]

A-1 series Closed

A-1

5.700 [144.8]

* Camco™ A-1 Series licensed from Schlumberger. Camco is a mark of Schlumberger. † The spring and choke will be sized to match well performance. †† These valves can be matched to any lock with a suitable crossover. The working pressure of the system is equal to the lowest pressure rating of any component in the lock,valve, and nipple combination. ‡ The engineering data provided illustrate the scope of this product offering and are not all inclusive. Additional sizes and pressure ratings are a vailable upon request. ‡ ‡ Injection valves suit any landing nipple with a bore size 0.03 in. larger than the OD of the valve. ™ The Tejas logo is a trademark of Tejas Research & Engineering LLC Direct request for quotations to: [email protected]

Copyright Tejas Research & Engineering, LLC 2015, All rights reserved 9185 Six Pines Dr., The Woodlands, TX 77380 Phone: 281 466 8700

www.tejasre.com [email protected]