Connect each DC device to terminal pairs on DC output board 1 thru 8, marked [P (+) and N (-)] carefully observing correct polarity. Connect each AC device to terminal pairs on AC output board 1 thru 8, marked [P (+) and N (-)]. 6. When batteries are being used the DC output voltage must be adjusted by turning the trim pot ...

ALTV1224C AC/DC Dual Output Power Supply Overview: The Altronix ALTV1224C AC/DC Dual Output Power Supply is designed to provide both 12VDC and 24VAC outputs where a combination of both AC and DC outputs are required. Provides eight (8) 12VDC outputs with a total current of 3.5 amp and eight (8) 24VAC outputs with a total current of 3.5 amp.

+ DC INPUT -

DC

- BAT +

AC

1

ON

2 3

XFMR

AC

AC

4

MAIN FUSE

MAIN FUSE

Black Lead

D1

FUSED

N

COMMON

POWER

POWER

DC Outputs

OUTPUTS

OUTPUTS

R1

LED

INPUT

5 6 7 8

D1

FUSED

N

COMMON

POWER

POWER

OUTPUTS

OUTPUTS

115VAC, 50/60 Hz Input, 1.52 amp

OFF

1 2 3 4

P

White Lead

ON

5 6 7 8

OFF

1 2 3 4

P

ON

Specifications: • 115VAC 50/60 Hz, 1.52 amps. • 7 amp total output current. • 16 individually fused outputs. • 3.5 amp supply current at 12VDC (Fig. 1). • Eight (8) outputs @ 12VDC. • 3.5 amp supply current at 24VAC (Fig. 1). • Eight (8) outputs @ 24VAC. • Output fuses are rated at 3.5 amp / 250VAC. • Main fuses are rated at 5 amp / 250VAC (Fig. 1). • Surge suppression. • AC /DC power LED indicator. • Power ON/OFF switch. • Spare fuses included. • Unit maintains camera synchronization. • Ease of installation saves time and eliminates costly labor. Enclosure dimensions: 15.5"H x 12"W x 4.5"D

R1

LED

INPUT

AC Outputs

Optional available with 220VAC input order model # ALTV1224C/220. Installation Instructions: Wiring methods shall be in accordance with the Fig. 1 National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 2). Secure enclosure to earth ground. 2. Slide switch SW1 (Fig. 1) to OFF position. 3. Connect the AC (115 VAC 50/60 Hz) to the two black and white flying leads of the transformers (Fig 1). 4. Measure output voltage before connecting devices. This helps avoid potential damage. 5. Connect devices to output terminals using the following procedure (Fig. 1). Connect each DC device to terminal pairs on DC output board 1 thru 8, marked [P (+) and N (-)] carefully observing correct polarity. Connect each AC device to terminal pairs on AC output board 1 thru 8, marked [P (+) and N (-)]. 6. When batteries are being used the DC output voltage must be adjusted by turning the trim pot VR1 (Fig 1) clockwise to increase the output voltage to 13.7 VDC. Connect battery to terminals marked [- BAT +] (Fig. 1) on the unit (battery leads included). CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage. When the battery charging voltage is increased the DC output voltage will also increase. 7. Slide switch SW1 (Fig. 1) to ON position. 8. Green LED on the PD8’s will illuminate when power is present. 9. Upon completion of wiring, secure enclosure door with screws (supplied).

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code. Terminal Identification: SMP5

Terminal Legend AC/ AC + DC - BAT +

Function/Description Low voltage AC input (24VAC / 175VA). Altronix part # T24175. 12VDC @ 3.5 amp total supply current. Stand-by battery connections. Maximum charge rate .5 amp.

PD8 (DC Output)

1P - 8P 1N - 8N

Positive DC power outputs. Negative DC power outputs.

PD8 (AC Output)

1P - 8P 1N - 8N

AC power outputs. AC power outputs.

Enclosure Dimensions: 15.5"H x 12"W x 4.5"D

1.285 1.285

Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: [email protected], Made in U.S.A. IIALTV1224C - Rev. 113004 A05J

MEMBER

Recommend Documents
Green LED on the circuit board will illuminate when power is present. 8. Upon completion of wiring, secure enclosure door with screws (supplied). WARNING: To ... 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site:

Tracking, Independent, Series and Parallel modes of operation. Dual Tracking, Triple Output DC Power Supply. Ordering ... Constant Voltage (CV) and. Constant ...

All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com. Single power supply with multiple DC outputs. 6/5/08 - R2.

4.1 Instrument Hook-Up. 1. Turn off the power supply and the equipment to be powered during hook- up. 2. Connect the positive polarity of the device being ...

Data Sheet. Technical data subject to change. © B&K Precision Corp. 2015 v082515 www.bkprecision.com. Tel.: 714.921.9095. Specifications. Specifications.

Data Sheet. Technical data subject to change. © B&K Precision Corp. 2015 v082515 ... ≤0.01% +3 mV (A&B). ≤10 mV (C). Recovery Time. 100µs. Ripple.

The 9130 is a fully programmable triple Output DC Power Supply delivering ... (9 kg). Dimensions (W x H x D). 8.45" x 3.47" x 13.9". (214.5 x 88.2 x 354.6 mm).

Regulated Multiple Output AC/DC Power .... Warranty Service: Please go the support and service section on our website www.bkprecision.com to obtain a RMA ...

0.05% + 10 mV (< 1% second and third output). Recovery Time ... 22820 Savi Ranch Parkway, Yorba Linda, CA 92887. Tel: 714-921-9095, Fax: 714-921-6422.

programmable DC power supply featuring isolated outputs that can be adjusted independently or combined in series or parallel to output higher voltage or ...