Green LED on the circuit board will illuminate when power is present. 8. Upon completion of wiring, secure enclosure door with screws (supplied). WARNING: To ... 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: [email protected], Made in U.S.A..

ALTV1224C4 AC/DC Dual Output Power Supply

XFMR IN AC2

DC

AC1

F3

OFF

SW2

F4

ON

OFF

SW1

+ DC1 ---

Voltage Adjustment

Wire Strap (from Enclosure to Door)

+ DC2 ---

Door

F1

F2

ON

Specifications: • 115VAC 50/60 Hz, 2 amps. • Four (4) individually fuse protected outputs: - Two (2) outputs @ 12VDC. - Two (2) outputs @ 24VAC. • 2 amp supply current at 12VDC (Fig. 1). • 4 amp supply current at 24VAC (Fig. 1). • Output fuses are rated at: AC fuses: 3.5 amp / 250VAC. DC fuses: 1 amp / 250VAC. • AC/DC power LED indicators. • Power ON/OFF switch. • Spare fuses included. • Unit maintains camera synchronization. • Ease of installation saves time and eliminates costly labor. Enclosure dimensions: 13.5"H x 13"W x 3.25"D

AC

Overview: The Altronix ALTV1224C4 AC/DC Dual Output Power Supply is designed to provide both 12VDC and 24VAC outputs where a combination of both AC and DC outputs are required. Provides two (2) 12VDC outputs with a total current of 2 amp and two (2) 24VAC outputs with a total current of 4 amp.

Black Lead

Input 115VAC 60Hz, 2 amp

XFMR XFMR Installation Instructions: 1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the Fig. 1 enclosure’s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 2). Secure enclosure to earth ground. 2. Slide switches SW1, SW2 to OFF position. 3. Connect the AC (115VAC 50/60 Hz) to the two black and white flying leads of the transformers. 4. Measure output voltage before connecting devices. 5. Connect devices to output terminals using the following procedure. Connect DC cameras to terminals marked [+ DC1 --, + DC2 --] carefully observing the correct polarity. Connect AC cameras to terminals marked [AC1, AC2]. 6. Slide switches SW1, SW2 to ON position. 7. Green LED on the circuit board will illuminate when power is present. 8. Upon completion of wiring, secure enclosure door with screws (supplied). White Lead

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to all local codes and in accordance with the National Electrical Code. Fuse Replacement: 1. Before replacing fuses slide switchs SW1, SW2 to OFF position. 2. Replace AC outputs fuses F1 or F2 with fuses rated @ 3.5 amp/250VAC. Replace DC outputs fuses F3 or F4 with fuses rated @ 1 amp/250VAC.

Terminal Identification: Terminal Legend Function/Description XFMR IN Low voltage AC input from two (2) (24VAC / 100VA). + DC1 -, + DC2 DC power outputs. AC1, AC2 AC power outputs. Enclosure Dimensions: 13.5"H x 13"W x 3.25"D 1.40"

4.85"

4.85"

1.40"

1.20" 3.25"

Top 12.50"

1.20" 0.75"

1.20" 0.75"

11.00"

0.9375"

1.40"

1.40"

5.10"

5.10"

Left

Right

5.10" 6.5625"

0.9375"

3.25"

3.25"

Bottom 3.25"

1.00"

1.00"

1.00"

10.50"

1.00"

Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: [email protected], Made in U.S.A. IIALTV1224C4 - Rev. 062906 F29F

MEMBER

Recommend Documents
Connect each DC device to terminal pairs on DC output board 1 thru 8, marked [P (+) and N (-)] carefully observing correct polarity. Connect each AC device to terminal pairs on AC output board 1 thru 8, marked [P (+) and N (-)]. 6. When batteries are

Tracking, Independent, Series and Parallel modes of operation. Dual Tracking, Triple Output DC Power Supply. Ordering ... Constant Voltage (CV) and. Constant ...

All rights reserved including the right of reproduction in whole or in part in any form. www.extech.com. Single power supply with multiple DC outputs. 6/5/08 - R2.

4.1 Instrument Hook-Up. 1. Turn off the power supply and the equipment to be powered during hook- up. 2. Connect the positive polarity of the device being ...

Data Sheet. Technical data subject to change. © B&K Precision Corp. 2015 v082515 www.bkprecision.com. Tel.: 714.921.9095. Specifications. Specifications.

Data Sheet. Technical data subject to change. © B&K Precision Corp. 2015 v082515 ... ≤0.01% +3 mV (A&B). ≤10 mV (C). Recovery Time. 100µs. Ripple.

The 9130 is a fully programmable triple Output DC Power Supply delivering ... (9 kg). Dimensions (W x H x D). 8.45" x 3.47" x 13.9". (214.5 x 88.2 x 354.6 mm).

Regulated Multiple Output AC/DC Power .... Warranty Service: Please go the support and service section on our website www.bkprecision.com to obtain a RMA ...

0.05% + 10 mV (< 1% second and third output). Recovery Time ... 22820 Savi Ranch Parkway, Yorba Linda, CA 92887. Tel: 714-921-9095, Fax: 714-921-6422.

programmable DC power supply featuring isolated outputs that can be adjusted independently or combined in series or parallel to output higher voltage or ...