G A N Mini Safety Limit Switch SLM

Report 3 Downloads 84 Views
SLM

C

US

Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 CSA approved



Actual Size

2.13 in 54 mm

safety interlock switches

G

SLM

250 Vac 2A 100 Vac 5A Made in England

0.96 in 25 mm

SLM

Mini Safety Limit Switch ■





Miniature size will fit in the most confined spaces, while providing the performance of larger units NEMA 1 enclosure makes the SLM suitable for dry, dust-free, indoor applications





Positive operation—all contacts are force guided for positive operation by the actuator conforming to safety switch standards Long life—the SLM with its stainless steel roller plunger is designed for ten million actuations

Choice of roller plunger orientations will satisfy most installation requirements

A N Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 G124

For the Latest Information On the Internet: www.sti.com or www.omron.ca

Go to the Engineering Guide For in-depth information on safety standards and use.

For More Guarding Products See Section N for safeguarding cutting and turning machines

SLM or

or

Operation Trojan

Cadet/Ensign

Elf/Sprite

Contact Arrangements

(A)

FRS1

or

30°

Senator

Imp

FRS1, 2, 20, 21

AC/DC A2 A1 34 100% ED. 53 22 54 42 41 12

2.5 Ferrotek

Ferrocode

AC/DC A2 A1 34 100% ED. 51 22 52 42 41 12

33 21 11

33 21 11

AC/DC 100% ED. 3

A1 A2

Titan TLS 3

or Typical Application of SLM with a Safety Monitoring Relay Lifeline 1

Lifeline 2

Lifeline 4

CU2

MSR5T

MSR9T

MSR10 RD

K1 (AUX)

23

12

24

A1

11

12

23

STOP MOMENTARY PUSH BUTTON

SLM SERIES SWITCH

SLM SERIES SWITCH

S11

S21

S12

S14

13

CU1 RESET

23

33

41

K1

relay control and fault monitoring

Power supply (S11 = 24 V)

MOMENTARY PUSH BUTTON

MSR7C

+

K2

K2

24

AC/DC A1 A2 100% ED.

+

STOP

K1

3

Sr103Am A2

S10

S13

EB SERIES LATCHING E-STOP BUTTON

14

24

9 10

CONTACT PROTECTION E.G. THERMAL CUT OUT

8 22 4

m

Atlas424 (3 pole)

34

MSR11R & 12T

FUSE

FUSE K1

7 21

BUTTON 1

11

K2

Trojan

BUTTON 2

GUARD CLOSED

L1 L2 L3

K2 (AUX)

E-STOP

START MOMENTARY PUSH BUTTON

Rotacam 3pole

Protekta 2 hand control

a full explanation of the circuit operating principle and fault detection, see ✎ For “Common Circuit Examples” in the Engineering Section of this catalog. Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

9 10

Atlas 4

Application Diagram

24VAC/DC, 110VAC, 230VAC

G

7

safety interlock switches

Titan TLS 1 & 2 ■

CONTROL UNIT

1

Ferrocode Sensor

The actuating cam should be profiled at 30° for optimum operation.

.0197 5

SENSOR

0.039 1

SENSOR

11/12 23/24

CONTROL UNIT

(SLM 1 & 2 - slow break make) 0

FRS21

Operating Example

FRS20

Cam Displacement

FRS2



For the Latest Information On the Internet: www.sti.com or www.omron.ca

G125

SLM



Application

Typical applications are on sliding guard doors, moving machine beds, crane arms, etc.



safety interlock switches

G

Specifications

Electrical

All Models

Contact Configurations:

1 N/C + 1 N/O



Safety Contacts:

1 N/C positive break



Switching Ability





AC:

500 V–1 A, 250 V–2 A, 100 V–5 A



DC:

250 V–0.5 A, 24 V–2 A



Safety Contact Gap:

> 2 mm (0.079 in.)



Auxiliary Contacts:

1 N/O



Max Switching Current/Volt/Amp:

500 V/500 VA



Minimum Current:

5 V 5 mA DC



Electrical Life:

1 x 106 minimum

Mechanical

Mounting:

Any position



Mounting Hardware:

2 x M3 or 2 x M4 screws



Actuator Travel for Positive Opening:

2.5 mm (0.098 in.)



Max Actuator Travel:

5 mm (0.197 in.)



Break Contact Min Force:

10 N (2.25 lb.)



Max Actuation Speed:

160 mm/sec (6.30 in./sec)

Max Actuation Frequency:

2 cycles/sec

Case Material:

UL listed glass-filled polyester



Actuator Material:

Stainless steel roller/acetal plunger



Wiring Entry:

3 x wiring breakous



Weight:

36 g (1.3 oz.)



Color:

Red



Mechanical Life:

10 x 106 minimum

Environmental

Protection:

IP30 (NEMA 1)



Operating Temperature:

-25 to 80°C (-13 to 176°F)

Compliance

Standards:

EN1088, EN292, EN60947-5-1, EN60204-1



Approvals/Listings:

CE marked for all applicable directives, CSA

Specifications are subject to change without notice. Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)— i.e., with the guard closed, actuator in place, and the machine able to be started.

A N

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766 G126

For the Latest Information On the Internet: www.sti.com or www.omron.ca

Go to the Engineering Guide For in-depth information on safety standards and use.

For More Guarding Products See Section N for safeguarding cutting and turning machines

SLM



Dimensions — mm/in.

10.3 0.41

11.0 0.43 2xM4

4.0 0.16 37.7 1.48 15.0 0.59 25.0 0.98

20.0 0.79

4.0 0.16 23.3 0.92

15.2 0.60

G safety interlock switches



5 MM ROLLER TRAVEL

54.0 2.13

2.4 0.09

2xM3

Ordering

Model Contacts

Wiring Entry

Part No.

SLM-1K (Roller parallel to switch front)

1 N/C + 1 N/O

3 x wiring breakouts

44511-0010

SLM-2K (Roller parallel to switch side)

1 N/C + 1 N/O

3 x wiring breakouts

44511-0020

Accessories (see page G238)

Omron Scientific Technologies, Inc. USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766

For the Latest Information On the Internet: www.sti.com or www.omron.ca

G127