In-Line Circulators Series S & H - National Pump Supply


Dec 5, 2013 - pump, eliminating cumbersome disconnecting of pipes. ▻ Oversized Shaft. Armstrong circulating pumps have an oversized shaft made.

Series S & H

In-Line Circulators

(Maintenance free option avaliable) File No: Date: Supersedes: Date:

10.10 dec. 05, 2013 10.10 october 01, 2013

Series S & H

Armstrong Series S & H in-line circulators are suitable for applications such as hydronics heating and cooling, domestic water systems, multi-stage zoning and general industrial service. Both models are available in a wide range of sizes to match the performance requirements of any of these applications. Armstrong Series S & H circulators are durable and trusted products that have been used by hvac professionals for decades. Besides the existing Sleeve bearing design, Armstrong now has introduced the ‘Maintenance free’ design which has permanently lubricated ball bearings and require no maintenance at all.  Design Features

 Centrifugal Impeller

Armstrong Series S & H in-line circulators are built using a standard three-piece design that features a radially-split body, oversized shaft, centrifugal impeller, sintered silicon carbide seal and modular construction.

 Body The radially-split body can be left in line while servicing the pump, eliminating cumbersome disconnecting of pipes.

 Oversized Shaft Armstrong circulating pumps have an oversized shaft made from either special alloy steel, (sleeve bearing design) or stainless steel (‘Maintenance free’ design) machined to exacting tolerance. Both shaft designs provide longer life under severe working conditions.

The balanced, centrifugal-design impeller ensures maximum water delivery in the hvac system.

 Positive Mechanical Seal A proven method of preventing water leakage, the well known sintered silicon carbide construction is a frequently imitated feature of the Armstrong circulator. Made from long-lasting hard-wearing materials, it ensures many years of noise-free, trouble-free service.

 Modular Construction Models s-25 through s-57 and h-32 through h-54 feature a unique Armstrong shaft and bearing module which fits all of these models for ease of serviceability and reduced inventory costs.

 Materials of Construction iron body pump

part name

bronze-fitted construction

volute

lf bronze body pump*

Cast iron

s-25 to s-57 h-32 to h-54 impeller s-69 h-63 to h-68 mechanical seal assembly bearing shaft

Lead free bronze Non-ferrous Non-ferrous Brass-stamped

Cast bronze Cast lf bronze Sintered silicon carbide seal Sleeve oil lubricated/permanently lubricated Alloy steel-copper sleeve/stainless steel

* Certified ≤0.25 weighted average percent lead and complies with California Health and Safety Code Section 116875 (commonly known as ab1953).

 Design Information max operating conditions

s-25 to s-69, h-32, h-41

h-51 to h-54, h-63 to h-68

125 psi at 225°f (862 kPa at 107°c)

175 psi at 225°f (1207 kPa at 107°c)

Notes: 1 All circulators are to be mounted with pump and shaft in horizontal position. 2 For domestic hot water or fresh water systems, always specify bronze body pumps or lead free bronze body pumps. 3 For temperatures over 225°f (107°c) consult your Armstrong representative. 4 Maintenance free S&H circulators are identified by ‘mf’ in their item numbers.

Series S & H In-Line Circulators  Composite Performance Charts  Series S This chart is based on 1800 rpm, 60Hz motors.

(12.1) 40 P R E F E R R E D

(10.7) 35 S-69 3"

Total Head -eet f (m)

(9.1) 30

S E L E C T I O

N A

S-57 3"

(7.6) 25

For 50 Hzmotors write for special capacity char ts.

R

E

A

S-55 3"

(6.1) 20 S-46 3" (4.6) 15

(3.0) 10

S-35 2" S-25 ¾", 1", 1¼" & 1½"

(1.5)5

(0.0)0

0 (0)

S-45 2½" & 3"

10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 (0.63) (1.26) (1.89) (2.52) (3.15) (3.78) (4.41) (5.05) (5.68) (6.31) (6.94) (7.57) (8.20) (8.83) (9.46) (10.09) (10.73) Flow - USgpm (L/s)

 Series H

H-65

. .

H-64 H-68

H-63

H-66 H-67 H-41 H-52

H-32

H-54 H-53

H-51

 Typical Specification Furnish and install as shown on the plans, Armstrong S or H Series Circulating Pump, designed for quiet operation and guaranteed by the manufacturer for the intended application. The pump shall have a capacity of USgpm (L/s), handling (state liquid and temperature) against a total head of ft (m). Pump shall be equipped with a hp (kW), Volt, phase, Hz, 1800 rpm drip-proof

mounted motor. Pump shall be construction, three-piece design featuring the Armstrong shaft and bearing module which shall fit all models s-25 through s-57 and h-32 through h-54. Pump to be equipped with a water-tight, long-life silicon carbide mechanical seal and be suitable for psi (kPa) working pressure.

 Pump and Motor Data model

motor flange size (npt) hp volts & phase

dimensions inches (mm)

shipping weight lbs (kg)

a

b

c

d

13.75 (349) 13.75 (349) 13.75 (349) 13.75 (349)

6.50 (165) 6.50 (165) 6.50 (165) 6.50 (165)

11.50 (292) 11.50 (292) 11.50 (292) 11.50 (292)

0.75 (19) 0.75 (19) 0.88 (22) 0.88 (22)

20 (9) 20 (9) 20 (9) 20 (9)

¾ 1 1¼ 1½

A/ab A/ab A/ab A/ab

S-35

2

V

15.00 (381)

8.50 (216)

12.50 (318)

0.88 (22)

35 (16)

S-45

2½ 3

¼ ¼

15.75 (400) 15.75 (400)

10.00 (254) 10.00 (254)

12.50 (318) 12.50 (318)

1.00 (25) 1.00 (25)

51 (23) 51 (23)

S-46

3

L

15.75 (400)

10.00 (254)

12.50 (318)

1.00 (25)

51 (23)

S-55

3

½

19.50 (495)

12.00 (305)

16.00 (406)

1.00 (25)

82 (37)

S-57

3

¾

20.00 (508)

12.00 (305)

16.50 (419)

1.00 (25)

85 (39)

S-69

3

1

­­25.00 (635)

14.25 (362)

20.25 (514)

1.00 (25)

135 (61)

S-25

model

115 Volt 1 phase

115/230 Volt 1 phase or 208-230/460 or 575 Volt 3 phase

motor flange size (npt) hp volts & phase

dimensions inches (mm)

shipping weight lbs (kg)

a

b

c

d

15.00 (381) 15.00 (381) 15.00 (381)

8.50 (216) 8.50 (216) 8.50 (216)

12.50 (318) 12.50 (318) 12.50 (318)

0.88 (22) 0.88 (22) 0.88 (22)

33 (15) 33 (15) 33 (15)

15.25 (387)

8.50 (216)

12.50 (318)

0.75 (19)

33 (15)

H-32

1 1¼ 1½

T T T

H-41

1

T

H-51

1

¼

17.25 (438)

11.50 (292)

13.50 (343)

0.75 (19)

54 (24)

H-52



L

17.25 (438)

11.50 (292)

13.50 (343)

0.88 (22)

54 (24)

H-53



½

20.00 (508)

11.50 (292)

16.50 (419)

0.88 (22)

64 (29)

H-54

2

¾

20.00 (508)

11.50 (292)

16.50 (419)

0.88 (22)

71 (32)

H-63



½

23.00 (584)

13.50 (343)

19.75 (502)

0.88 (22)

96 (44)

H-64



¾

23.00 (584)

13.50 (343)

19.75 (502)

0.88 (22)

100 (45)

H-65



1

23.00 (584)

13.50 (343)

19.75 (502)

0.88 (22)

102 (46)

H-66

2

¾

23.25 (591)

14.00 (356)

19.75 (502)

0.88 (22)

120 (54)

H-67

2

1

23.25 (591)

14.00 (356)

19.75 (502)

0.88 (22)

125 (57)

H-68

2



21.75 (552)

14.00 (356)

18¼ (464)

0.88 (22)

130 (59)

115 Volt 1 phase

115/230 Volt 1 phase or 208-230/460 or 575 Volt 3 phase

208-230/460 or 575 Volt 3 phase Notes:

1 Dimensions given are for reference only. For exact dimensional data, contact factory. 2 All single-phase motors are equipped with built-in thermal overload protection.

Three-phase motors require external overload protection.

3 Companion flanges not furnished as standard on s-25, s-45 and h-32. 4 For other design characteristics, consult your Armstrong Representative.

toronto 23 Bertrand Avenue Toronto, Ontario Canada, m1l 2p3 t +1 416 755 2291 f +1 416 759 9101

buffalo 93 East Avenue North Tonawanda, New York U.S.A., 14120-6594 t +1 716 693 8813 f +1 716 693 8970

manchester Wenlock Way Manchester United Kingdom, m12 5jl t +44 (0) 8444 145 145 f +44 (0) 8444 145 146 ©armstrong fluid technology 2013

For Armstrong Fluid Technology locations worldwide, please visit www.armstrongfluidtechnology.com

Recommend Documents
Series e-60 ECM Bronze Fitted. RATED MOTOR CHARACTERISTICS. PUMP DESCRIPTION. MODEL. NUMBER. PART. NUMBER. FLANGE. SIZE. HP VOLTAGE PHASE Hz. AMPS. MIN. RPM. MAX. RPM. MOTOR MODEL. #. WEIGHT. Series e-60 ECM - 1x1x5.25, .50 HP, 115V. e650S-ECM BF. 1E

Mar 2, 2015 - Taco 2400 Series High Capacity Circulators are specifically designed for quiet, efficient, dependable operation in a wide range of medium to high flow/head hydronic heating, chilled water cooling and hot water recirculation applications

Mar 2, 2015 - Compact, space saving design. • Powerful close-coupled, maintenance free motor. • Superior efficiency, high starting torque. • Permanently lubricated, sealed for life bearings. • Rugged 1/2" Stainless Steel Shaft. • Carbon/Sil

Taco In-Line Circulators are designed to efficiently circulate heated or chilled water in residential or light commercial Hydronic Systems. These circulators may also be used for zoning large installations and are available in bronze or stainless ste

Dec 5, 2013 - Cast bronze. Cast lf bronze mechanical seal assembly. Sintered silicon carbide seal bearing. Sleeve oil lubricated/permanently lubricated shaft.

Requesting other information. Special versions can be supplied with supplementary instruction leaflets. See the sales contract for any modifications or special version characteristics. For instructions, situations, or events that are not considered i

Gas mask. • Hearing protection. • First-aid kit. • Safety devices. NOTICE: Never operate a unit unless safety devices are installed. Also see specific information.

This pump also has available power levels that range from 1/4 to 3 hp and 1750 rpm. ..... Insert the new wave spring into the rear bearing bore. 3. Lubricate the ...

For cast iron bearing assemblies, install the coverplate on the housing. 6. If used, install the adapter ring and gasket on the new bearing assembly. 7. Install the impeller on the new bearing assembly and use the new impeller nut and lockwasher prov

3. Insert a long punch between the impeller vanes or grasp the impeller with a strap wrench in order to prevent the impeller from turning. 4. Remove the impeller ...