INSTALLATION INSTRUCTIONS

Report 0 Downloads 36 Views

Most of the procedures require the use of common tools and materials, which are ... BAR (1) works best if secured to a wall stud or cross brace within the wall,.

INSTALLATION INSTRUCTIONS Rem Personal Hand Shower with Adjustable Wall Mounted Bar ®

Model D35100780

Phillips Screwdriver Drill

Teflon Tape

Plumbers' Putty or Caulking

Level

Flat Blade Screwdriver

ROUGHING-IN DIMENSIONS: • For reference 1/2" (13 mm)

2-1/8" (54 mm)

1-1/16" (27 mm) WALL SUPPLY WITH BUILT IN BACK FLOW PREVENTER

1/2" (13 mm) N.P.T. 1-3/8" D. (35 mm) 48" - 60" (1219 - 1524 mm) (OPTIONAL) TO FINISHED FLOOR

23-5/8" (600 mm)

27-3/8" (695 mm)

2-3/8" (59 mm)

2-9/16" DIA. (65 mm)

1-7/16" (37mm)

1/2 (13 mm) NPSM HOSE CONNECTION RUBBER GASKET FINISHED WALL

7-3/4" (197 mm) 5-3/4" (146 mm)

FINISHED WALL In the United States: DXV One Centennial Avenue Piscataway, New Jersey 08855 Attention: Director of Customer Care For residents of the United States, warranty information may also be obtained by calling the following toll free number: (800) 227-2734 www.DXV.com Product names listed herein are trademarks of AS America, Inc. © AS America, Inc. 2017

59" (1498 mm)

1" (25mm) In Canada: DXV 5900 Avebury Road Mississauga, Ontario L5R 3M3 Canada Toll Free: 1-800-387-0369 Local: 905-306-1093 Fax: 1-800-395-1498 www.DXV.ca

-1-

In Mexico: DXV Via Morelos 330 Col. Santa Clara Coatitla Ecatepec, Estado de México 55540 Toll Free: 01-800-8391200 www.DXV.mx

M965507 Rev. 1.6 (5/17)

F U T U R E

Adjustable Wrench

F O R

Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing supply stores. It is essential that the tools and materials be on hand before work is begun.

S A V E

RECOMMENDED TOOLS AND MATERIALS

U S E

Thank you for selecting DXV. To ensure that your installation proceeds smoothly, please read these instructions carefully before you begin.

1 INSTALL WALL SUPPLY CAUTION

2

Turn off hot and cold water supplies before beginning.

1

• Supply to WALL SUPPLY (1) is 1/2" NPT. See rough-in above for detailed information. • Install RUBBER SEAL (2) onto WALL SUPPLY (1). • Apply sealant or teflon tape to threads of 1/2" NPT supply nipple. Thread WALL SUPPLY (1) onto supply nipple making a water tight seal. WALL SUPPLY (1) with RUBBER SEAL (2) should be tight against finished wall.

1/2" NPT APPLY SEALANT

2 INSTALL WALL BRACKETS • The ADJUSTABLE SHOWER BAR (1) works best if secured to a wall stud or cross brace within the wall, using the SCREWS (2) supplied. • If the ADJUSTABLE SHOWER BAR (1) is to be installed on a tile or plaster wall the ANCHORS (4) and SCREWS (2) should be used. • Secure MOUNTING PLATES (3) to wall with SCREWS (2). • For installations on drywall or tiled walls: Use ANCHORS (4) and SCREWS (2) for securing MOUNTING PLATE (3) to finished wall. Drill two 1/4" dia. holes a minimum of 1-3/4" deep. Insert the two ANCHORS (4) flush with face of the finished wall. • Determine desired height and location (optional) of the top MOUNTING PLATE (3). Using the TEMPLATE (12) supplied mark the two spots for the ANCHORS (4). Use a level to make the center line between the two MOUNTING PLATES (3) vertical. If the MOUNTING PLATES (3) are secured to a stud or cross brace drill small pilot holes for SCREWS (2).

3 INSTALL ADJUSTABLE SHOWER BAR 2

• Install ADJUSTABLE SHOWER BAR (1) onto installed MOUNTING PLATES (3). Push ADJUSTABLE SHOWER BAR (1) flush against finished wall and tighten SET SCREWS (5) with HEX WRENCH (6) supplied with accessory.

3

4

C/L

C/L

USE MOUNTING PLATE AS TEMPLATE

5 11

*23-5/8" (600 mm) FINISHED WALL

6

9

2

1

10

LEVEL

OPTIONAL TO FINISHED FLOOR

3

8 6

12

4

7

C/L

*FROM CENTER TO CENTER OF WALL BRACKETS *NOTE: MEASURMENT IS APPROXIMATE ONLY, PLEASE USE BAR AS TEMPLATE FOR ACTUAL CENTER TO CENTER MEASUREMENTS.

5

-2-

M965507 Rev. 1.6 (5/17)

4 INSTALL HOSE AND HAND SHOWER • Install SEAL (6) into COUPLING NUT (7). Connect COUPLING NUT (7) to WALL SUPPLY NIPPLE (8) and tighten. • INSTALL second SEAL (9) into SPRAY HOSE END (10 ) and connect HAND SHOWER (11) to SPRAY HOSE END (11). Hand tighten.

5 TEST INSTALLED HAND SHOWER • Lift HAND SHOWER (1) from HOLDER (2) and direct spray into tub. Turn hand shower valve on to check HAND SHOWER (1) for proper operation and hose connections for leaks. • Use KNOB (3) on HOLDER (2) to adjust HAND SHOWER (1) height on slide bar.

1

2 3

-3-

M965507 Rev. 1.6 (5/17)

Rem

®

Personal Hand Shower with Adjustable Wall Mounted Bar MODEL NUMBER

D35100780 Replace the “YYY” with appropriate finish code POLISHED CHROME

100

BRUSHED NICKEL

144

M964660-0070A MOUNTING KIT

D35100781.XXX HAND SHOWER M964659-YYY0A SHOWER BAR END

H960440.XXX HOSE & SEALS

M964561-YYY0A ADJUSTABLE BAR

D35700035.XXX WALL ELBOW

M964512-0070A SET SCREW

-4-

M965507 Rev. 1.6 (5/17)

Recommend Documents
Feb 7, 2017 - Plug remaining holes with the appropriate color plugs. ... Run connection wires through large hole between mounting holes C ... WHITE COMM.

FINIAL/CAP ASSEMBLY, HEX NUT, and. LOCKWASHER. Then carefully lift the. CAGE ASSEMBLY, tilting it at an angle to clear the bulbs and LAMPHOLDERS.

Installation & Setup. Mount the appropriate 11 pin octal socket (Macromatic 70170-D or. Custom Connector OT11-PC) in a suitable enclosure. Wire the socket.

Feb 7, 2017 - SURFACE MOUNT EDGE-LIT LED EXIT SIGN ... the switch is released, EXIT section remains ON and the LED indicator turns back to RED.

If you have any questions, please call our customer service line at ... Insert the end of the misting line into the faucet connector for about 1/2 in. to 5/8 in. by.