...a step into a digital world 130416 • 02215
Kabel 22/99
Description
Data Sheet
Halogen free, low smoke emission and UV resistant coaxial cable 75 Ohm Security sheath of LSZH material (Screening Class A)
LSNH grå 2,2/9,9
22/99ZH
Art. nr: 413 11 57 | Kabel 22/99, 2,2/9,9 grå LSNH 250 m | E-nr: 41 311 57
2,20 (Cu)
9,90 (PEG)
10,00 (Cu/Pet)
10,48 (Cu)
(LSZH)
Constructive data
Inner conductor of plain copper
(Cu)
2,20 ± 0,10
mm
Dielectric of physical foam polyethylene
(PEG)
9,90 ± 0,15
mm
Water repellent sealing (dielectric)
(Jelly1)
Copper/Polyester tape longitudinally overlapped
(Cu/Pet)
Braid of annealed copper wires
(Cu)
Braid optical coverage (IEC 96-1)
55 %
Tracer Identifier
Year + Flag
Outer sheath of Thermoplastic material grey (RAL 7001) halogen-free, flame retardant and UV-resistant (Q8)
(LSZH)
12,70 ± 0,15
Printed each meter by yellow ink-jet : CCS TV 75 Ohm CAVEL 2.2/9.9 ZH MADE IN ITALY EN50117-2-3 ss/aa m
(ss=week, aa=year) (m=meter marking) Electrical data
Characteristic impedance (@ 200 MHz)
75,00 ± 2,00
Ohm
Capacitance (@1kHz)
52,00 ± 2,00
pF/m
Inner conductor resistance
5,00
Outer conductor resistance Loop Resistance Insulation voltage of the sheath (spark test) Maximum current (Ieff)
Ohm/km
8,50
Ohm/km
13,50
Ohm/km
5,00
kV
21,00
A
Structural return loss (SRL) 5 - 470 MHz
>30 dB
470 - 1000 MHz
>28 dB
1000 - 2000 MHz
>23 dB
2000 - 3000 MHz
>20 dB
Screening attenuation (SA)
Transfer impedance
30 - 1000 MHz
>90 dB
1000 - 2000 MHz
>100 dB
2000 - 3000 MHz
>85 dB
www.macab.com
5 - 30 MHz
0,4 mOhm/m
mm
... a step into a digital world Description
Data Sheet
Halogen free, low smoke emission and UV resistant coaxial cable 75 Ohm Security sheath of LSZH material (Screening Class A)
22/99ZH
Attenuation (at 20°C and dB/100m): Frequency [MHz]
Attenuation [dB/100m]
Frequency [MHz]
Attenuation [dB/100m]
862 1000 1750 2150 2400 3000
9,10 9,80 13,30 14,90 15,70 18,30
0,80 1,10 1,50 2,00 4,00 4,90 6,40
5 10 30 50 200 300 470 Mechanical data
Weight of copper conductors Total weight of cable
60,30
kg/km
148,30
kg/km
Minimum bending radius (single/repetead bending)
150
mm
Max. cable pulling strenght
600
N
Attenuazione di schermatura / Screening Attenuation Cavo classe A / A Class Cable Cavo tipo / Cable type :
-45
22/99 ZH
-50
Attenuazione di schermatura / Screening attenuation (dB)
-55
< 5 mOhm/m
-60 --65 65 -70 --75 75 -80 --85 85 -90 -95
-100 -105 -110 -115 -120
Limiti secondo norma EN50117 Limits as per EN50117 Std
-125 -130 -135 0,1
1
Connector FM-13 IEC14M-13
5
100 30 Frequenza / Frequency (MHz)
1000 1000
2000 3000
10000
F male connector for outdoor and underground installation, nitin-plated brass - 58,5 x 22,5 mm IEC male connector for outdoor and underground installation, nitin-plated brass - 70,0 x 23,0 mm N male connector for outdoor and underground installation, nitin-plated brass - 62,0 x 23,0 mm 5/8" connector for outdoor and underground installation, nitin-plated brass - 59,0 x 22,5 mm 3,5/12" connector for outdoor and underground installation, nitin-plated brass - 68,0 x 23,0 mm
NM-13 5/8MU-13 3,5/12M-13
ITALIANA CONDUTTORI s.r.l. Viale Zanotti 90
10
Date
I - 27027 Gropello Cairoli
Tel +39-382.815150
Responsible
02/07/07
Fax +39-0382.814212
GRG-Macab AS Lierstranda 82 NO-3414 Lierstranda, Norway Phone: +47 32 22 99 90 Fax: +47 32 22 99 91
[email protected] Macab AB Post: Box 3 SE-231 21 Trelleborg, Sweden Besök: Vannhögsgatan 7, SE-231 66 Trelleborg Tel: +46 (0) 410 36 36 10 Fax: +46 (0) 410 36 36 01
[email protected] PierPaolo Piccinini
Max Nordic A/S Friis Hansensvej 2 DK-7100 Vejle, Denmark Telefon: +45 31 68 20 10
[email protected] www.macab.com
Page 2 / 2