Heavy Duty. Receptacles and Connectors†. Delayed Action for Hazardous Areas. CPS. 1002. CES/CESD. 1011. Non-Interlocked For Non-Hazardous Areas.

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0959-5 Name: P-959

100: DATE: JAN 19 2006

Time: 6:04:18 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Plugs & Receptacles Section P

959

STIBOINFO((CRH:66008com:P:959)) CHI NT R OP

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0960-12 Name: P-960

P

100: DATE: JAN 19 2006

Time: 6:04:20 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Plugs and Receptacles Considerations for Selection

The Plugs and Receptacles Section of the Cooper Crouse-Hinds Product Catalog contains complete technical information on the Cooper Crouse-Hinds line of these products. In addition to product listings and features, the section contains information on interchangeability of plugs and receptacles, the different grounding methods incorporated in the construction of the units, and separate sections devoted to receptacles interlocked with switches and/or circuit breakers. The product lines featured are Arktite,® and ARK-trol plugs and receptacles and CableGard TM cord and cable reels.

Considerations for Selection

Arktite Series

Grounding

Metallic and non-metallic Arktite series units are available for use in hazardous and nonhazardous areas for general purpose, heavyduty applications in power circuits. All units through 200 ampere rating offer circuit breaking capability under load; some units are offered with interlocking mechanism with switch and/or circuit breaker, where dead front receptacles are desired, 400 ampere units are for service disconnect use only and are not for current interrupting. An interchangeability table on page 961 graphically shows interchangeability between products in the complete line of pin and sleeve type plugs and receptacles. Full electrical rating details are shown in the interchangeability charts at the beginning of each section in the Plugs and Receptacles Section of this catalog.

Cooper Crouse-Hinds utilizes two methods for completing the grounding circuit in plugs and receptacles. Style 1: A Style 1 plug is one in which the grounding conductor in the flexible cable is bonded to the plug sleeve by a pressure connector. A Style 1 receptacle is one which is grounded by virtue of the fact that it is an integral part of a grounded conduit system. On insertion, the plug sleeve makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded. Style 2: A Style 2 plug is one in which the grounding conductor in the flexible cable is bonded to the extra (grounding) pole and sleeve by a pressure connector. A Style 2 receptacle is one in which the extra (grounding) pole is electrically connected to the equipment grounding conductor and the receptacle housing which itself is grounded by virtue of the fact that it is an integral part of a grounded conduit system. In a Style 2 receptacle, the grounding connection is made before line and load poles engage, and is broken after line and load poles disengage. Furthermore, upon insertion, the plug sleeve of metal shelled units makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded. This method is used on plugs and receptacles for hazardous areas, on configured Arktite and on all Arktite products made of Krydon® material.

ARK-trol Series Units are available for use in hazardous and non-hazardous areas for special purpose application in power and/or control circuits where environmental factors are important or a wide range of contacts, sizes and configurations is required.

Cable-Gard Series Electric cord and cable reels are used extensively in modern factories for ‘‘managing’’ all loose extension cables to ensure safety, increase efficiency, and extend cable and portable equipment life. Electric reels automatically transmit electric current (power or control) from a stationary position to a moving consumer of current.

960

STIBOINFO((CRH:66008com:P:960)) CH0 0 0 P - 0

The considerations in the selection of plugs and receptacles are the electrical ratings desired and the physical location of the units. This information, together with the product features, construction details, and customer benefits, is shown on the individual pages in selecting the proper plugs and receptacles, other factors in addition to the electrical ratings and the physical aspects regarding location of the application (e.g., hazardous areas) should be considered. Principally, these factors are: interchangeability of plug and receptacle, interlocking and grounding.

US: 1-866-764-5454

CAN: 1-800-265-0502

It meets the National Electrical Code/ Canadian Electrical Code requirements for this equipment. The Arktite line offers a choice of both methods; other plugs and receptacles are offered in one of the two styles (details are given on the individual pages). Details on construction and diagrams of both methods are found in Section 1P, pages 966 and 967.

Interlocked Units Where added safety is desired and for units of higher ratings, Sections 3P and 4P detail receptacles with interlocked switches and/or circuit breakers. The ability to break the load before removal of the plug, circuit protection and disconnect capability are the prime benefits to be derived from equipment shown in those sections.

Interchangebility Between Cooper Crouse-Hinds Product Families A unique capability exists throughout much of the Cooper Crouse-Hinds plug and receptacle line that enables a variety of receptacles to be used with the same plug— provided the electrical rating and style of plug and receptacle are the same (see Interchangeability Table on next page). Where a common wiring system is in use, it is possible to use the same standard plug with a number of different receptacle assemblies located in different areas where each receptacle is selected to meet the physical or environmental requirement of the specific area. For example, a process industry facility could include Class I, Groups C and D areas and Class II, Group G areas as well as nonhazardous areas. A portable device suitable for use in the hazardous areas could be equipped with an APJ Arktite plug or NPJ Arktite plug made of Krydon® material and be used in all areas of the plant. The receptacle installation could include AR or NR units in the nonhazardous areas; DR receptacles or DBR interlocked receptacles in the Class II, Groups F and G areas and FSQ or EPC interlocked receptacles in the Class I, Groups C and D areas—all of which will accept the same APJ or NPJ plug. CPH Plugs can also be used with any receptacle which accepts a standard APJ or NPJ Arktite plug of the same ampere rating, style, and number of poles. This feature permits the use of a portable device, suitable for hazardous locations, in all areas of a plant, but prevents the use of an ‘‘ordinary locations’’ device in the hazardous areas. The following table is a summary of possible combinations. Full details describing the possibilities for interchanging plugs and receptacles are given in this section of the Cooper Crouse-Hinds Product Catalog.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0961-9 Name: P-961

100: DATE: JAN 19 2006

Time: 6:04:20 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Plugs and Receptacles

P

Interchangeability Table

Cooper Crouse-Hinds Pin and Sleeve Design Plugs†

Cooper Crouse-Hinds Heavy Duty Receptacles and Connectors†

Cat. Pg. APJ Delayed Action for Hazardous Areas CPS 1002 CES/CESD 1011

AP

BHP

BP

FP

Interlocked for Non-Hazardous Areas CSR 1024 ɀ DBR 1030 ɀ NBR 1034 ɀ NSR 1032 ɀ SRG 1028 WSR 1018 ɀ WSQC 1037 ɀ WSRD 1018 ɀ WSRD SS 1020 ɀ WSRDW 1018 ɀ

CPP

DP

NPJ

SP

ɀ ɀ

Non-Interlocked For Non-Hazardous Areas APR 966 ɀ ɀ AR 966 ɀ ɀ CPR 1006 NR 983 ɀ NPR 983 ɀ Interlocked for Hazardous Areas BHR 1049 DBR 1061 ɀ EBBR 1053 ɀ EPC 1056 ɀ EPCB 1059 ɀ FSQ230 1042 FSQ232 1042 FSQC 1042 ɀ SRD 1051 W2SR 1048 ɀ

CPH

ɀ ɀ ɀ ɀ

ɀ ɀ ɀ ɀ ɀ

ɀ ɀ ɀ ɀ

ɀ

ɀ ɀ ɀ ɀ ɀ

ɀ

ɀ ɀ ɀ ɀ

ɀ ɀ ɀ

ɀ

ɀ

ɀ

ɀ ɀ ɀ ɀ

ɀ ɀ ɀ ɀ

ɀ ɀ ɀ ɀ ɀ

ɀ ɀ ɀ ɀ ɀ

ɀ

ɀ

ɀ

ɀ

ɀ Plugs mate with indicated receptacles.

† Consult individual catalog pages for complete listing of Cooper Crouse-Hinds plugs, receptacles and connectors

US: 1-866-764-5454

STIBOINFO((CRH:66008com:P:961)) CH0 0 0 P - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

961

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0962-3 Name: P-962

P

100: DATE: JAN 19 2006

Time: 6:04:22 PM Operator: RB

COLOR: CMYK

TCP: 15001

Plugs and Receptacles Table of Contents

Section 1P Industrial Heavy Duty Plugs and Receptacles

Section 6P Wiring Devices with Covers

(for use in non-hazardous areas)

(for use in non-hazardous areas)

Receptacles Plugs AR AP, APJ, CPH, CPP, NPJ APR AP, APJ, APQ, CPH, CPP, NPJ, NPQ NR APJ, CPH, CPP, NPJ NPR APJ, CPH, CPP, NPJ, NPQ

WLRS/WLRD Covers GFCI Covers

Section 2P Industrial Heavy Duty Plugs and Receptacles (for use in hazardous areas) Receptacles CES, CESD CPR* CPS DR ENR

Plugs CPH CPP APJ, NPJ APJ, NPJ ENP

Cable-Gard TM Series W14 W16 W19 Static Discharge Reels

Section 8P Special Purpose Plugs and Receptacles (for use in non-hazardous areas)

Section 3P Interlocked Heavy Duty Plugs and Receptacles (for use in non-hazardous areas) Receptacles CSR DBR SRG NBR WSR, WSRD NSR DSR WSQC

Section 7P Industrial Cord and Cable Reels

Plugs APJ, NPJ APJ, CPH, NPJ SP, BHP APJ, CPH, NPJ APJ, CPH, NPJ APJ, CPH, NPJ APJ, CPH, NPJ APJ, CPH, NPJ

Ark-trol® Series RPC RPE

Section 9P Special Purpose Plugs and Receptacles (for use in hazardous areas) Ark-trol Series RPX

* Do not use in hazardous areas

Section 4P Interlocked Heavy Duty Plugs and Receptacles (for use in hazardous areas) Receptacles BHR DBR EPC EBBR EPCB FSQ SRD DSR W2SR

Plugs BHP, SP APJ, CPH, NPJ APJ, DP, CPH, NPJ APJ, CPH, NPJ APJ, CPH, NPJ APJ, BP, CPH, NPJ SP, BHP APJ, CPH, NPJ APJ, CPH, NPJ

Section 5P IEC309

962

STIBOINFO((CRH:66008com:P:962)) CH0 0 0 P - 2

Pin & Sleeve

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0963-5 Name: 1P-963

100: DATE: JAN 19 2006

Time: 6:04:22 PM Operator: RB

COLOR: CMYK

TCP: 15001

Plugs and Receptacles Industrial Heavy Duty Non-Hazardous

Typedriver Name: TS name csm no.: 100

1P

Description

Page No.

Application/Selection

964, 965

Arktite® Series Technical Data Aluminum AR/APJ Style 20A 30A 60A 100A 200A 400A Configured Arktite® ARC/APJC Style Technical Data 30, 60, 100A Back Boxes Krydon® NR/NPJ Style Technical Data 30, 60, 100A Flanged Panel Mount Motor Plugs

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:963)) CH0 0 0 0 1 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

966-969 970 972, 973 974, 975 976, 977 978-980 981, 982 986, 987 988, 989 990, 993 983 984, 985 994, 995 996, 997

963

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0964-3 Name: 1P-964

100: DATE: JAN 19 2006

Time: 6:04:23 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Plugs and Receptacles

1P

Industrial Heavy Duty Application and Selection

Application: ɀ Distribution of secondary electrical power ɀ Provide quick disconnect from power source

Considerations for Selection:

Options:

Electrical System: ɀ Amperage and voltage required for application Wiring system and number of conductors required. See page 969 for contact sizes. Compatibility with System: ɀ Need for interchangeability with plugs in existing system and within parts of new system. Grounding styles. Two styles utilized. See page 967 for complete description to determine which is suitable for needs. Mounting Arrangement: ɀ Three types of mounting available – surface, flush and panel Application: ɀ Fixed receptacle for power outlet; cable connectors for portable cable extensions Other Considerations: ɀ Wire sizes and recess dimensions available. See page 969 for complete details. National Electrical Code, UL, NEMA, Canadian Electrical Code, CSA compliances ɀ Environment – need for operation in harsh, dirty or corrosive conditions.

ɀ Special polarity arrangements available as well as special back boxes and hub arrangements. See listing pages for details.

Quick Selector Chart Electrical Characteristics No. of Poles (Range)

Grounding Style† Mounting

Mating Plug

600VAC 250VDC

2-5

1-2

APJ, NPJ, APQ, AP

30, 60, 100

600VAC 250VDC

3-5

2

APJC, APQC

Fixed

20, 30, 60, 100, 200, 400

600VAC 250VDC

2-5

1-2

Back box (surface)

APJ, NPJ, AP

ARC

Fixed

30, 60, 100

600VAC 250VDC

3-5

2

Back box (surface)

APJC

AR

Fixed

30, 60, 100, 200

600VAC 250VDC

2-4

1-2

Panel mtg. (semi-flush)

APJ, NPJ, AP

NPR

Portable cable

30, 60, 100

600VAC 250VDC

3-4

2

NR

Fixed

30, 60, 100

600VAC 250VDC

3-4

2

Receptacle Series

Receptacle Type

Amperage (Range)

Volts (Max.)

APR

Portable cable

20, 30, 60, 100, 200, 400

APRC

Portable cable

AR

NPQ, APJ, NPJ (fixed) Back box (surface)

† See page 967 for detailed explanation.

964

STIBOINFO((CRH:66008com:1P:964)) CH0 0 1 P - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

APJ, NPJ

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0965-2 Name: 1P-965

DATE: JAN 19 2006

Time: 6:04:24 PM Operator: JB

COLOR: CMYK

TCP: 15001

Plugs and Receptacles

Typedriver Name: TS name csm no.: 100

1P

Industrial Heavy Duty Interchangeability Chart

Interchangeability Chart Many of the plugs listed in this section can be used interchangeably with receptacles from other sections, both in hazardous and nonhazardous areas, provided electrical rating and style of plug and receptacle are the same. The following table is a summary of possible combinations.

Plugs Shown in Section 1P

Can be Used with These Receptacle Series

Listed in Section

APJ, NPJ*

DR

2P

30, 60 amp. 2-wire, 2-pole 3-wire, 3-pole 4-wire, 4-pole 2-wire, 3-pole 3-wire, 4-pole

DBR

3P

30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole

FSQ

4P

30 amp. 2-wire, 3-pole 3-wire, 4-pole

EPC, EPCB, EBBR

4P

30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole

NBR, NSR

3P

30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole

WSR

3P

30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole

WSRD

3P

60 amp. 3-wire, 3-pole 3-wire, 4-pole

AR, NR*, NPR*

1P

30 and 60 amp. 2-wire, 3-pole

DR, CES, CESD

2P

FSQ, EPC, EPCB, DBR

4P

DBR, NBR, NSR, WSR, WSRD

3P

CPH

Plugs & Receptacle Electrical Rating

30 and 60 amp. 3-wire, 4-pole

* NPJ, NR and NPR available in 2-wire, 3-pole and 3-wire, 4-pole electrical ratings only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:965)) CH0 0 1 P - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

965

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0966-2 Name: 1P-966

1P

100: DATE: JAN 19 2006

Time: 6:04:24 PM Operator: JB

Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

Industrial Heavy Duty Non-Hazardous Areas illustrated here, is for conditions where it is desired to use the contact of the plug sleeve with the detent spring to complete the grounding safety circuit. The extra grounding conductor in the portable cable is connected to the plug sleeve by a pressure connector.) Each plug contact fits closely the opening of its individual arcing chamber. Grounding contact is bonded to the plug sleeve. Grounding contact is keyed to its proper location to prevent mispolarization. Arktite connectors’ gasketing system provides unsurpassed watertight integrity. All-aluminum UNI-SHELL TM threaded construction provides added strength to withstand extreme physical abuse.

Application: Arktite circuit breaking plugs and receptacles are used: ɀ to supply power to portable electrically operated devices such as motor-generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems and similar equipment ɀ where temporary power is needed, such as at trailers, building units, heavy machinery and similar equipment ɀ wherever electrical loads must be quickly disconnected from power source ɀ in a typical installation, where a large machine utilizes a number of electrical motor drives and for ease of adjustment, removal, maintenance and replacement, each motor is connected by portable cord and Arktite receptacles rather than permanently wired ɀ in areas where dust, dirt, moisture and corrosion are a problem ɀ indoors and outdoors in non-hazardous areas of chemical plants, process industry facilities, meat packing plants, manufacturing plants and similar industrial locations

NEW! NEMA 4 Rating

Features: ɀ Circuit breaking: Plugs through 200 ampere rating may be disconnected under load; 400 ampere units are for service disconnect use only. ɀ Receptacles accept only plugs of the same amperage rating, style and number of poles, making it impossible to mismate, and provides for positive polarization. ɀ Extra wide electrical spacing allows for maximum safety. ɀ Insulator materials are the result of intensive testing. Selection has been made based on highest dielectric strength, maximum mechanical and impact resistance, lowest moisture absorption and highest arc tracking resistance. ɀ A variety of installations is possible due to the availability of several types of back boxes. ɀ Designed to withstand rough usage and the effects of adverse environments. ɀ Reversible interiors, 30, 60 and 100 ampere (except 30 and 60 ampere, 5-pole) Arktite plug and receptacle interiors are interchangeable using a screwdriver. This makes it possible to feed a normally deenergized receptacle from an energized plug with usual Arktite safety; no energized contacts are exposed. ɀ Additional features are indicated in the view at right: Grounding contact in Style 2 is bonded to the receptacle housing. Easily wired interior assemblies in receptacles and plugs. See table on page 938 for type of contacts in units. Arktite Style 2, illustrated here, has an extra grounding contact which forms a parallel circuit with the circuit formed by the plug sleeve and receptacle detent spring, and assures continuity of the grounding

966

STIBOINFO((CRH:66008com:1P:966)) CH0 0 1 P - 2

Arktite Style 2 60 ampere

NEW! Smaller Cable Range safety circuit under severe service. Grounding contact is no longer than the others, so grounding circuit is made first and broken last. The arc formed by pulling the plug is instantly snuffed in the deep, confined insulated arcing chamber while the plug contact is still a considerable distance inside. The arc cannot travel over to the other side of the circuit or to the housing. Detent spring forms a grounding path from plug sleeve to receptacle housing. Arktite plugs and receptacles are made in two styles. With either style, the portable appliance is grounded before it is energized and remains grounded until after it is deenergized. (Arktite Style 1, not

US: 1-866-764-5454

CAN: 1-800-265-0502

Arktite’s TRI-LOCK TM cable grip has three clamps that tighten around the cable to securely lock it in place, even when subjected to extreme flexing and jerking. The unique SURE-SEAL TM cable gland provides a complete environmental seal by distributing pressure equally around the circumference of the cable. Wrenching surfaces make Arktite connector quick and easy to assemble.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0967-29 Name: 1P-967

100: DATE: JAN 19 2006

Time: 6:05:30 PM Operator: RB

Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

1P

Industrial Heavy Duty Non-Hazardous Areas

Grounding: Style 1 vs. Style 2 Cooper Crouse-Hinds Arktite devices utilize two methods, or styles, for completing the grounding circuit in plugs and receptacles. NEC reference 250.138 (A) & (B).

Style 1 – Metallic

STYLE 2 – Metallic

Style 2 – Non-Metallic

A Style 1 plug is one in which the grounding conductor in the flexible cable is bonded to the plug sleeve by a pressure connector. A Style 1 receptacle is one which is grounded by virtue of the fact that it is an integral part of a grounded conduit system. On insertion, the plug sleeve makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded.

A Style 2 metallic housing plug is one in which the grounding conductor in the flexible cable is bonded to the extra (grounding) pole and metal plug sleeve by a pressure connector. A Style 2 metallic housing receptacle is one in which the extra (grounding) pole is electrically connected to the equipment grounding conductor and the metal receptacle housing which itself is grounded by virtue of the fact that it is an integral part of a grounded conduit system. In Style 2, non-metallic housing plugs and receptacles, the extra pole is used for grounding since the housings are nonconductive.

In a Style 2 receptacle, the grounding connection is made before line and load poles engage, and is broken after the line load poles disengage. Furthermore, upon insertion, the plug sleeve of metal shelled units, makes contact with detent springs of the grounded receptacle housing before line and load poles engage, and on withdrawal, remains in contact until after line and load poles disengage. Therefore, exposed metal parts of the portable equipment or plug are suitably grounded. Made of non-metallic Krydon material

Metal shelled type

Style 2 Ground conductor attaches to contact, which is bonded to shell.

Style 1 Ground conductor attaches to shell.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:967)) CH0 0 1 P - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

967

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0968-18 Name: 1P-968

1P

100: DATE: JAN 19 2006

Time: 6:05:35 PM Operator: RB

COLOR: CMYK

TCP: 15001

Arktite® Heavy Duty Circuit Breaking§ Plugs and Receptacles

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

Industrial Heavy Duty Non-Hazardous Areas

Options: ɀ The following special options are available from factory by adding suffix to Cat. No.: Suffix to be Added to Cat. # Description S22. . . . .Reversed contacts. Receptacle assembled with plug interior (exposed contacts), plug assembled with receptacle interior (recessed contacts). For applications where plug is energized to feed normally deenergized receptacle. Available on 30 through 400 ampere units NOTE: 30 (2, 3, 4-pole), 60 and 100 ampere interiors can be interchanged in the field using a screwdriver. Factory conversion is required for 200 and 400 ampere products. S4. . . . . .Special polarity. For use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages and/or frequencies. Prevents insertion of a plug in a receptacle with different electrical rating. Available on 20 through 400 ampere units as follows: Receptacle interior rotated 221⁄2 degrees to right and plug changed to match (See photo to right)

Arktite receptacles have a cast raised rib located inside the receptacle sleeve. The location of the rib is in a specific relationship to the receptacle insulator that houses the contacts.

The mating plug has a cast groove located on the outside of the plug sleeve. This groove lines up with the raised rib.

Standard Materials: ɀ Metallic receptacle housings, plug and cord connector bodies – high impact strength copper-free aluminum ɀ Nonmetallic receptacles, plugs and cord connectors – Krydon® fiberglass-reinforced polyester material ɀ Back boxes: 20, 30, 60, 100 and 200 ampere – cast aluminum; 400 ampere – Feraloy® iron alloy ɀ Insulation (metallic products): (2-, 3-, and 4-pole) 30, 60, 100, 200, 400 ampere – fiberglass-reinforced polyester; 20, 30 ampere (5-pole) – melamine ɀ Contacts: pressure, solder, binding screw – brass; crimp/solder – leaded red brass; 20, 30, 60, 100 ampere – telurium copper; 200, 400 ampere

Accessories: Accessories include a variety of angle adapters, panel adapters and back boxes for Arktite receptacles, listed on pages 990-993. Included throughout 1P are wire mesh cable grips and protective caps for Arktite plugs.

Certifications and Compliances: ɀ UL Standards: 1682, 514; 1010 (APJ and NPJ plugs only) ɀ CSA Standard: C22.2 No. 182.1 Typical installation

Standard Finishes: ɀ Feraloy—electrogalvanized and aluminum acrylic paint ɀ Aluminum – natural ɀ Krydon fiberglass-reinforced polyester material – grey ɀ Fiberglass-reinforced polyester insulation – (red) ɀ Melamine – natural (brown) ɀ Brass – natural ɀ Leaded red brass – electro-tin-plate § 400A rated units are for service disconnect use only.

968

STIBOINFO((CRH:66008com:1P:968)) CH0 0 1 P - 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0969-13 Name: 1P-969

DATE: JAN 19 2006

Time: 6:05:36 PM Operator: RB

COLOR: CMYK

Arktite® Heavy Duty Circuit Breaking§ Plugs and Receptacles

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

1P

Industrial Heavy Duty Non-Hazardous Areas

Arktite Horsepower Ratings ɀ Locked-Rotor Interrupting Electrical System Single-phase

Three-phase

ɀ Emergency Interrupting

Ampere Rating Plug and Receptacle 30 60 100 200

Motor Horsepower† 120 240 480 Volts Volts Volts 2 3 7.5 5 10 25 10 20 15 40

600 Volts 10 20

30 60 100 200

3 10 15 30

10 50 25 15

5 20 30 60

10 40 40 25

Electrical System Single-phase

Three-phase

Ampere Rating Plug and Receptacle 30 60 100 200

H.P. Rating 120 240 Volts Volts 2 3 5 10 7.5 20 15 40

480 Volts 10 25 30 40

600 Volts 10 20 30 40

30 60 100 200

3 10 10 20

15 40 40 50

20 50 40 50

7.5 20 30 60

Wire Sizes: The table below lists the diameter of the wire recess in Arktite plug and receptacle contacts so that maximum size of bare conductor can be figured. Range of wire sizes shown in table is intended only as a guide. Depending on type of wire used (building wire, flexible or extra flexible cable) and its construction (number and size of strands), bare copper diameters vary widely.

Diameter of Wire Recess in Plug and Receptacle Contacts Ampere Rating 20 30 (2, 3, & 4-pole) 30 (2, 3, & 4-pole) 30 (5-pole) 60 (2, 3, 4 & 5-pole) 60 (3 & 4-pole) 100 (2, 3 & 4-pole) 100 (3 & 4-pole) 200 (Std. 3 & 4-pole) 200 (Lg. 3 & 4-pole) 400 (Std. 3 & 4-pole) 400 (Lg. 3 & 4-pole)

Contact Type Binding Screw Pressure Crimp/Solder Solder Pressure Crimp/Solder Pressure Crimp/Solder Crimp/Solder Crimp/Solder Crimp/Solder Crimp/Solder

Diameter of Recess N/A .281 .180 .188 .312 .277 .390 .390 .56 .75 .84 1.25

Wire Size‡ Building #14-#12 #10-#6 #10-#8** #12-#6 #6-#4 #6-#4** #4-#1 #2-#1** #1-4/0 4/0-250MCM 250-500MCM 500-1000MCM

Extra Flex #14-#12 #10-#8 #10-#8 #12-#8 #8-#4 #8-#4 #4-#2 #2-#2 #1-3/0 3/0-250MCM 250-400MCM 400-750MCM

** Smaller sizes may be used with well reducers – information on request. † Horsepower ratings are based on Cooper Crouse-Hinds testing in which locked-rotor currents were interrupted by withdrawing the plug from the receptacle. It is highly recommended, however, that such use be limited to emergency conditions only; and that a horsepower rated switch be used for motor disconnect.

‡ Do not use wire size smaller than minimum size recommended. § 400A rated units are for service disconnect use only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:969)) CH0 0 1 P - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

969

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0971-4 Name: Note Page-970

DATE: JAN 19 2006

Time: 6:05:39 PM Operator: KN

COLOR: CMYK

Notes Page

970

STIBOINFO((CRH:66008com::970)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0970-44 Name: 1P-971

DATE: JAN 19 2006

Time: 6:05:37 PM Operator: KN

Arktite® Heavy Duty Circuit Breaking Receptacles, Plugs and Connectors

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

1P

20 A, 600 VAC/250 VDC, 50**-400 hertz

Receptacle with Back Box Config. 2W 2P 2W 2P

Hub Size 1⁄2 1⁄2 3⁄4 3⁄4

Descrip. Spring Door Threaded Cap Spring Door Threaded Cap

Cat No. # ARE2211 ARE2271 ARE2212 ARE2272

Receptacle Config. 2W 2P

Descrip. Spring Door Threaded Cap

Cat No. # AR221 AR227

Plug Config. 2W 2P

Cable Dia. .250–.500 .250–.500

Descrip. Fastening Ring W/O Fastening Ring

Cat No. # APJ2271 APJ2251

2W 2P

.500–.875 .500–.875

Fastening Ring W/O Fastening Ring

APJ2273 APJ2253

Descrip. Connector Connector

Cat No. # APR2251 APR2253

Connector Config. 2W 2P

Cable Dia. .250–.500 .500–.850

Dimensions ARE Assembly

AR Receptacle - Spring Door

AR Receptacle - Open and with cap

APJ Plug

Hub size a 11⁄16 1⁄2 3⁄4 13⁄16 NOTE: For listing of additional back boxes, see pages 999 and 991. ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:971)) C H 100 1 P - 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

971

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0972-12 Name: 1P-972

DATE: JAN 19 2006

Time: 6:05:40 PM Operator: RB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings

1P

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

30 A, 600 VAC/250 VDC, 50**-400 hertz

Receptacle Assembly

With ARE Back Boxes Style 1 Description

Mating Plug

Receptacle

Receptacle Housings Only Style 1

Mating APJ Plugs† Style 1

Hub‡ Size

Spring Door Cat. #

Spring Door Cat. #

Threaded Cap Only Cat. #

2-wire, ⎫ 2-pole ⎬⎭

1⁄2 3⁄4

ARE3211 ARE3212

AR321

AR327

3-wire, ⎫ 3-pole ⎬⎭

3⁄4 1

ARE3312 ARE3313

AR331

AR337

4-wire, ⎫ 4-pole ⎬⎭

3⁄4 1

ARE3412 ARE3413

AR341

AR347

5-wire, ⎫ ⎬ 5-pole ⎭

1

ARE3513

AR351

Style 2

Style 2

Mating APR Connectors Style 1

Cat. #

Cable Dia.

Cat. #

Cable Dia.

APJ3275

0.39 to 1.20

APR3255

0.39 to 1.20

APJ3375

0.39 to 1.20

APR3355

0.39 to 1.20

APJ3475

0.39 to 1.20

APR3455

0.87 to 1.02

APJ3573

.500 to .875

APR3553

.500 to .875

Style 2

2-wire, ⎫ 3-pole ⎬⎭

3⁄4 1

ARE3322 ARE3323

AR332

AR338

3-wire, ⎫ 4-pole ⎬⎭

3⁄4 1

ARE3422 ARE3423

AR342

AR348

4-wire, ⎫ ⎬ 5-pole ⎭

1

ARE3523

AR352

Style 2

APJ3575

.875 to 1.375

APR3555

.875 to 1.375

APJ3485

0.39 to 1.20

APR3465

0.39 to 1.20

APJ3583 APJ3585

.500 to .875 .875 to 1.375

APR3563 APR3565

.500 to .875 .875 to 1.375

Dimensions ARE Assembly

AR Receptacle - Spring Door

Plug

AR Receptacle - Open and with cap

Connector

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

972

STIBOINFO((CRH:66008com:1P:972)) CH0 0 1 P - 8

US: 1-866-764-5454

Mating Connector

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0973-7 Name: 1P-973

DATE: JAN 19 2006

Time: 6:05:42 PM Operator: JB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

1P

30 A, 600 VAC/250 VDC, 50**-400 hertz

Plug Closure Caps: Application: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing

Standard Materials:

Config.

Cat No. #

2P & 3P & 4P 5P

CPK13 CPK32

ɀ Copper-free aluminum

Standard Finishes: ɀ Natural

Replacement Parts:

Config.

Receptacle Interior

Plug Interior

2W 2P 2W 3P 3W 3P 3W 4P 4W 4P 4W 5P 5W 5P

ATP275 ATP278 ATP276 ATP279 ATP277 ATP125 ATP94

ATP270 ATP273 ATP271 ATP274 ATP272 ATP109 ATP73

Spring Door

Screw Cap

QE50

QE13

N/A

N/A

Recep

Plug

AR30CONKIT

AP30CONKIT

Replacement Pin & Sleeve Contacts: Description Available as a kit only. 5 phase contacts & 1 ground contact included

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:973)) CH0 0 1 P - 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

973

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0974-10 Name: 1P-974

DATE: JAN 19 2006

Time: 6:05:43 PM Operator: JB

COLOR: CMYK

Arktite ® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings

1P

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

60 A, 600 VAC/250 VDC, 50**-400 hertz

Receptacle Assembly

With AJ Back Boxes and Angle Adapters

Style 1

Threaded Cap Only Cat. #

Mating Plug

Receptacle

with ARE Back Boxes

Receptacle Housing Only

Spring Door Cat. #

Spring Door Cat. #

Threaded Cap Only Cat. #

Cable Dia.

Mating Connector

Description

Hub Spring Door Size Cat. #

Cat. #

Cat. #

2-wire, ⎫ 2-pole ⎬⎭

1 11⁄4

AREA6213 AREA6214

ARE6213 ARE6214

AR621

AR627

0.50 to 1.45

APJ6275

APR6255

3-wire, ⎫ 3-pole ⎬⎭

1 11⁄4

AREA6313 AREA6314

ARE6313 ARE6314

AR631

AR637

0.50 to 1.45

APJ6375

APR6355

4-wire, ⎫ 4-pole ⎬⎭

11⁄4 11⁄2

AREA6414 AREA6415

ARE6414 ARE6415

AR641

0.50 to 1.45

APJ6475

APR6455

5-wire, ⎫ 5-pole ⎬⎭

11⁄4 11⁄2

AR657

0.50 to 1.45

APJ6575

AREA6574 AREA6575

Style 2 2-wire, ⎫ 3-pole ⎬⎭

1 11⁄4

AREA6323 AREA6324

ARE6323 ARE6324

AR632

AR638

0.50 to 1.45

APJ6385

APR6365

3-wire, ⎫ 4-pole ⎬⎭

11⁄4 11⁄2

AREA6424 AREA6425

ARE6424 ARE6425

AR642

AR648

0.50 to 1.45

APJ6485

APR6465

4-wire, ⎫ 5-pole ⎬⎭

11⁄4 11⁄2

AR658

0.75 to 1.45

APJ6585

APR6585 APR6567

Dimensions

AREA6584 AREA6585 AR Receptacle - Spring Door

APJ Plug

ARE Assembly

APR Connector AR Receptacle - Open and with cap

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

974

STIBOINFO((CRH:66008com:1P:974)) CH0 1 P - 1 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Config 2P or 3P 4P 5P

a 81⁄2 81⁄2 9

Copyright© 2006 Cooper Crouse-Hinds

Plug b c 53⁄4 35⁄8 513⁄16 33⁄4 63⁄16 47⁄16

Connector a b c 61⁄2 35⁄8 215⁄16 81⁄4 35⁄8 215⁄16 81⁄4 35⁄8 31⁄4

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0975-4 Name: 1P-975

DATE: JAN 19 2006

Time: 6:05:45 PM Operator: JB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

1P

60 A, 600 VAC/250 VDC, 50**-400 hertz

Plug Closure Caps: Application: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing

Standard Materials:

Config.

Cat No. #

2P & 3P 4P

CPK32 CPK34

ɀ Copper-free aluminum

Standard Finishes: ɀ Natural

Replacement Parts:

Config.

Receptacle Interior

Plug Interior

2W 2P 2W 3P 3W 3P 3W 4P 4W 4P 4W 5P 5W 5P

ATP295 ATP298 ATP296 ATP299 ATP297 ATP385 ATP384

ATP290 ATP293 ATP291 ATP294 ATP292 ATP387 ATP386

Spring Door

Screw Cap

QE51

QE32

QE52

QE34

N/A N/A

AR:11393B

Recep

Plug

AR60CONKIT

AP60CONKIT

Replacement Pin & Sleeve Contacts: Description Available as a kit only. 5 phase contacts & 1 ground contact included

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:975)) CH0 1 P - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

975

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0976-7 Name: 1P-976

DATE: JAN 19 2006

Time: 6:05:46 PM Operator: RB

COLOR: CMYK

Arktite ® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings

1P

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

100 A, 600 VAC/250 VDC, 50**-400 hertz

Receptacle Assembly

Mating Plug

Receptacle

Style 1

Mating Connector

Receptacle Housings Only

Hub Description Size

Spring Door Cat. #

Spring Door Cat. #

Threaded Cap Only Cat. #

2-wire, ⎫ 2-pole ⎬⎭

11⁄4 11⁄2

AREA10214 AREA10215

AR1021

AR1027

3-wire, ⎫ 3-pole ⎬⎭

11⁄4 11⁄2

AREA10314 AREA10315

AR1031

AR1037

4-wire, ⎫ 4-pole ⎬⎭

11⁄2 2

AREA10415 AREA10416

AR1041

AR1047

2-wire, ⎫ 3-pole ⎬⎭

11⁄4 11⁄2

AREA10324 AREA10325

AR1032

AR1038

3-wire, ⎫ 4-pole ⎬⎭

11⁄2 2

AREA10425 AREA10426

AR1042

AR1048

Style 2

Style 2

Cable Dia.

Cat. #

Cat. #

0.875 to 1.70

APJ10277

APR10257

0.875 to 1.70

APJ10377

APR10357

0.875 to 1.70

APJ10477

APR10457

Style 2 0.875 to 1.70

APJ10387

APR10367

0.875 to 1.70

APJ10487

APR10467

Dimensions ARE Assembly

AR Receptacle - Spring Door

APJ Plug

No. Poles f 9⁄32 2 or 3 13⁄32 4 AR Receptacle - Open and with cap

No. Poles 3 4 APR Connector

No. Poles 2 or 3 4 2 or 3 4

Housing open open with cap with cap

c 3 3⁄16 3 7⁄16 3 11⁄16 3 7⁄8

No. Poles 3 4

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

976

STIBOINFO((CRH:66008com:1P:976)) CH0 1 P - 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

b 6 9⁄16 6 5⁄8

c 3 3⁄4 4 1⁄8

b 3 3⁄8 3 1⁄2

c 3 3⁄16 3 7⁄16

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0977-3 Name: 1P-977

DATE: JAN 19 2006

Time: 6:05:48 PM Operator: JB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies and Housings

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight Dimensions Pages 947, 961, 964-966

1P

100 A, 600 VAC/250 VDC, 50**-400 hertz

Plug Closure Caps: Application: CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing

Standard Materials:

Config.

Cat No. #

2P & 3P 4P

CPK62 CPK64

ɀ Copper-free aluminum

Standard Finishes: ɀ Natural

Replacement Parts:

Config.

Receptacle Interior

Plug Interior

2W 2P 2W 3P 3W 3P 3W 4P 4W 4P 4W 5P 5W 5P

ATP315 ATP318 ATP316 ATP319 ATP317 N/A N/A

ATP310 ATP313 ATP311 ATP314 ATP312 N/A N/A

Spring Door

Screw Cap

QE53

QE62

QE54

QE64

N/A

N/A

Recep

Plug

AR100CONKIT

AP100CONKIT

Replacement Pin & Sleeve Contacts: Description Available as a kit only. 5 phase contacts & 1 ground contact included

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:977)) CH0 1 P - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

977

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0978-2 Name: 1P-978

1P

100: DATE: JAN 19 2006

Time: 6:05:49 PM Operator: JB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weatherproof

200 A, 600 VAC/250 VDC, 50**-400 hertz

See pages 966–969 for general Application, Features, Grounding, Standard Materials, Standard Finishes, Options, Accessories, Compliances, Electrical Rating Ranges, and Wire Sizes.

Plug Closure Caps:

Features:

CPK caps for Arktite plugs are used: ɀ where portable equipment is on a standby basis and plugs are not in use ɀ to effectively protect insulation and contacts from excessive moisture, dirt, dust and corrosion ɀ with 30, 60, 100 and 200 ampere plugs with fastening ring and standard 200 ampere plugs for the clamp door housing Config.

ɀ Grounding contact wire terminators will accommodate ground wire of same size as phase wire. ɀ Spring band contact design provides multiple points of electrical contact. Improves electrical reliability and significantly reduces effort required for insertion and withdrawal ɀ Crimp/solder type contacts are standard ɀ Large wire wells are available for ‘‘extra flexible’’ wire ɀ Larger wire well size connectors will interchange with connectors of other wire well size of same amperage and contact configuration. ɀ Self-closing spring doors on receptacles and cord connectors provide environmental sealing ɀ Threaded nuts provide positive plug retention ɀ Two piece plug and cord connector design provide easy installation NOTES: 1. For listing of additional back boxes, see page 991. 2. S22 suffix for reverse interiors is available from factory only. Field conversion cannot be done. 3. Replacement interiors for standard units vs. S22 units vary in length. Specify the unit type when ordering parts.

Application:

Standard Materials: ɀ Copper-free aluminum

3P 4P

Cat No. # CPK102 CPK104

Standard Finishes: ɀ Natural

Wire Mesh Grips: Application: Wire mesh grips are used: ɀ to provide secure cable termination ɀ to extend cable life ɀ with 20, 200 and 400 ampere plugs

Dimensions AREA Assembly

Features: ɀ Eliminate sharp radius of cable bend at the point where cable enters plug, thereby reducing cable failure ɀ Absorb longitudinal stresses placed on the point of termination caused by pulling the cable ɀ Gripping action increases in direct proportion to amount of tension applied to cable

Standard Material & Finishes: ɀ Stainless steel wire braid – Natural

Ordering Information: Plug Cable Range 1.375 to 1.875 1.875 to 2.500 AR Receptacle

No. Poles 3 4

AP Plug

c 4 3⁄16 4 9⁄16

Grip Range 1.375 to 1.625 1.625 to 1.875 1.875 to 2.000 2.000 to 2.250

APR Connector

d 3 1⁄4 3 5⁄8

** For use on system less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

978

STIBOINFO((CRH:66008com:1P:978)) CH0 1 P - 1 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Nominal Grip Length – Inches 8 11 10 113⁄4

Copyright© 2006 Cooper Crouse-Hinds

Grip Cat. # K163 K188 K200 K225

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0979-13 Name: 1P-979

DATE: JAN 19 2006

Time: 6:05:50 PM Operator: RB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weatherproof

1P

200 A, 600 VAC/250 VDC, 50**-400 hertz

Receptacle Assembly

Mating Plug

Receptacle

With AJ Back Boxes and Angle Adapters

Mating Connector

Receptacle Housings only

Style 1 – Wire Well Takes .56⍯ Maximum Conductor Size Hub Size

Spring Door Cover Cat. #

Spring Door Cat. #

Cable Dia.

Plug Cat. #

Connector Cat. #

3-wire, 3-pole

11⁄2 2 21⁄2

AREA20315 AREA20316 AREA20317

AR2031

0.875 to 1.375 1.375 to 1.875 1.875 to 2.500

AP20355 AP20357 AP20358

APR20315 APR20317 APR20318

4-wire, 4-pole

2 21⁄2

AREA20416 AREA20417

AR2041

0.875 to 1.375 1.375 to 1.875 1.875 to 2.500

AP20455 AP20457 AP20458

APR20415 APR20417 APR20418

1.375 to 1.875 1.875 to 2.500

AP203511 AP203512

APR203111 APR203112

1.375 to 1.875 1.875 to 2.500 2.500 to 3.000

AP204511 AP204512 AP204513

APR204111 APR204112 APR204113

Description

Style 1 – Wire Well Takes .75⍯ Maximum Conductor Size 3-wire, 3-pole

11⁄2 2 21⁄2

AREA203125 AREA203126 AREA203127

4-wire, 4-pole

2 21⁄2

AREA204126 AREA204127

AR20312

AR20412

Style 2 – Wire Well Takes .56⍯ Maximum Conductor Size 2-wire, 3-pole

11⁄2 2 21⁄2

AREA20325 AREA20326 AREA20327

AR2032

0.875 to 1.375 1.375 to 1.875 1.875 to 2.500

AP20365 AP20367 AP20368

APR20325 APR20327 APR20328

3-wire, 4-pole

11⁄2 2 21⁄2

AREA20425 AREA20426 AREA20427

AR2042

0.875 to 1.375 1.375 to 1.875 1.875 to 2.500

AP20465 AP20467 AP20468

APR20425 APR20427 APR20428

0.875 to 1.375 1.375 to 1.875 1.875 to 2.500

AP203610 AP203611 AP203612

APR203210 APR203211 APR203212

1.375 to 1.875 1.875 to 2.500

AP204611 AP204612

APR204211 APR204212

Style 2 – Wire Well Takes .75⍯ Maximum Conductor Size 2-wire, 3-pole

11⁄2 2 21⁄2

AREA203225 AREA203226 AREA203227

AR20322

3-wire, 4-pole

11⁄2 2 21⁄2

AREA204225 AREA204226 AREA204227

AR20422

Option: ɀ Mechanical lug wire conductor terminations. Add ‘‘L’’ to catalog prefix i.e. : ARL2042

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:979)) CH0 1 P - 1 2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

979

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0980-9 Name: 1P-980

DATE: JAN 19 2006

Time: 6:05:52 PM Operator: JB

Arktite® Heavy Duty Circuit Breaking Receptacle Assemblies

1P

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weatherproof

200 A, 600 VAC/250 VDC, 50**-400 hertz

200A Replacement Parts

200A Standard and S4 Receptacle Interior .56 wire well

.75 wire well

Plug Interior .56 wire well

Brass Retaining Shoe

.75 wire well

.56 wire well

.75 wire well

2W 3P

ATP401

ATP402

ATP433

ATP434

0490335

0490335

3W 3P

ATP397

ATP398

ATP429

ATP430

0490327

0490328

3W 4P

ATP403

ATP404

ATP435

ATP436

0490337

0490337

4W 4P

ATP399

ATP400

ATP431

ATP432

0490331

0490332

200A ST22 and S4 S22 Receptacle Interior .56 wire well

.75 wire well

Plug Interior .56 wire well

Brass Retaining Shoe

.75 wire well

.56 wire well

ATP417

ATP418

ATP449

ATP450

0490335

0490335

3W 3P

ATP413

ATP414

ATP445

ATP446

0490327

0490328

3W 4P

ATP419

ATP420

ATP451

ATP452

0490337

0490337

4W 4P

ATP415

ATP416

ATP447

ATP448

0490331

0490332

Cord Grip Assembly Cord Diameter Range .875 - 1.375 1.375 - 1.875 1.875 - 2.500

AP2 KIT1 M80 AP2 KIT2 M80 AP2 KIT3 M80

Plug Clamp Nut

Rec Spring Door

2W 3P 3W 3P

AP:0401965

AR:0401502-2

2W 3P 3W 3P

AP:0401964

AR:0401502-1

Replacement Pin & Sleeve Contacts 200A Standard & S4 Receptacle .56 wire well .75 wire well Phase Contact Ground Contact

0490339 0490343

0490340 0490344

200A S22 & S4 S22 Receptacle .56 wire well .75 wire well Phase Contact Ground Contact

980

STIBOINFO((CRH:66008com:1P:980)) CH0 1 P - 1 4

.75 wire well

2W 3P

0490351 0490347

US: 1-866-764-5454

0490352 0490348

CAN: 1-800-265-0502

Plug .56 wire well

.75 wire well

0490319 0490323

0490320 0490324

Plug .56 wire well

.75 wire well

0490355T 0490359

0490356 0490360

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0981-1 Name: 1P-981

DATE: JAN 19 2006

Time: 6:05:53 PM Operator: RB

Arktite® Heavy Duty Receptacle Assemblies

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weatherproof

1P

400 A, 600 VAC/250 VDC, 50-400 hertz

Features: ɀ Grounding contact wire terminators will accommodate ground wire of same size as phase wire ɀ Spring band contact design provides multiple points of electrical contact. Improves electrical reliability and significantly reduces effort required for insertion and withdrawal ɀ Crimp/solder type contacts are standard. ɀ Large wire wells are available for ‘‘extra flexible’’ wire ɀ Larger wire well connectors will interchange with connectors of other wire well size, of same amperage and contact configuration. ɀ Self-closing spring doors on receptacles and cord connectors provide environmental sealing ɀ Threaded nuts provide positive plug retention ɀ Two piece plug and cord connector design provide easy installation ɀ For disconnect use only – not for current interrupting NOTES: 1. For listing of additional back boxes, see page 991. Illustration shows 3 blank plates and 1 hub plate. 2. S22 suffix for reverse interiors is available from factory only. Field conversion cannot be done. 3. Replacement interiors for standard units vs. S22 units vary in length. Specify the unit type when ordering parts.

Dimensions With blank hub plate With hub plate max.

Wire mesh grips are used: ɀ to provide secure cable termination ɀ to extend cable life ɀ with 20, 200 and 400 ampere plugs

Features: ɀ Eliminate sharp radius of cable bend at the point where cable enters plug, thereby reducing cable failure ɀ Absorb longitudinal stresses placed on the point of termination caused by pulling the cable ɀ Gripping action increases in direct proportion to amount of tension applied to cable

Standard Material & Finishes: ɀ Stainless steel wire braid – Natural

Ordering Information: Plug Cable Range 1.375 to 1.875

AREX Assemblies Description

Wire Mesh Grips Application:

1.875 to 2.500

a

Grip Range 1.375 to 1.625 1.625 to 1.875 1.875 to 2.000 2.000 to 2.250

Nominal Grip Length – Inches 8 11 10 113⁄4

Grip Cat. # K163 K188 K200 K225

5⁄16

45⁄8

AP Plugs

AR Receptacles

No. Poles 3 4

c 5 3⁄16 5 13⁄16

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:981)) CH0 1 P - 1 6

APR Connectors

d 4 3⁄16 4 11⁄16

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

981

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0982-13 Name: 1P-982

DATE: JAN 19 2006

Time: 6:05:54 PM Operator: RB

Arktite® Heavy Duty Receptacle Assemblies

1P

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weatherproof

400 A, 600 VAC/250 VDC, 50-400 hertz Receptacle Assembly

Receptacle

Mating Plug

Mating Connector

With AJ Back Boxes‡ Receptacle Housings and Angle Adapters only Style 1 – Wire Well Takes .84⍯ Maximum Conductor Size Hub Size

Spring Door Cover Cat.#

Spring Door Cat. #

Cable Dia.

Plug Cat. #

Connector Cat. #

3-wire, 3-pole

21⁄2 3

AREX40317 AREX40318

AR4031

1.375 to 1.875 1.875 to 2.500

AP40357 AP40358

APR40317 APR40318

4-wire, 4-pole

21⁄2 3

AREX40417 AREX40418

AR4041

1.375 to 1.875 1.875 to 2.500

AP40457 AP40458

APR40417 APR40418

2.500 to 3.000 3.000 to 3.800

AP403510 AP403512

APR403110 APR403112

2.500 to 3.000 3.000 to 3.800

AP404510 AP404512

APR404110 APR404112

1.375 to 1.875 1.875 to 2.500

AP40367 AP40368

APR40327 APR40328

1.375 to 1.875 1.875 to 2.500

AP40467 AP40468

APR40427 APR40428

2.500 to 3.000 3.000 to 3.500

AP403610 AP403612

APR403210 APR403212

2.500 to 3.000 3.000 to 3.500

AP404610 AP404612

APR404210 APR404212

Description

Style 1 – Wire Well Takes 1.25⍯ Maximum Conductor Size 3-wire, 3-pole

3 31⁄2 4

AREX403128 AREX403129 AREX4031210

AR40312

4-wire, 4-pole

4 5

AREX4041210 AREX4041212

AR40412

Style 2 – Wire Well Takes .84⍯ Maximum Conductor Size 2-wire, 3-pole

2 21⁄2 3

AREX40326 AREX40327 AREX40328

AR4032

3-wire, 4-pole

21⁄2 3

AREX40427 AREX40428

AR4042

Style 2 – Wire Well Takes 1.25⍯ Maximum Conductor Size 2-wire, 3-pole

3 31⁄2 4

AREX403228 AREX403229 AREX4032210

AR40322

3-wire, 4-pole

4 5

AREX4042210 AREX4042212

AR40422

† Furnished with cable grip and neoprene bushing.

982

STIBOINFO((CRH:66008com:1P:982)) CH0 1 P - 1 2

US: 1-866-764-5454

CAN: 1-800-265-0502

‡ Hub plates and blank plates may be interchanged to permit conduit feed from bottom or sides.

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0983-3 Name: 1P-983

100: DATE: JAN 19 2006

Time: 6:05:55 PM Operator: RB

COLOR: CMYK

Non-Metallic Arktite® Heavy Duty Circuit Breaking Plugs and Receptacles Made of Krydon® Material, 600 VAC/250 VDC, 50-400 hertz;

TCP: 15001

Typedriver Name: TS name csm no.: 100

Watertight§ Corrosion-Resistant NEMA 4X Dimensions Pg. 984

1P

Application: Arktite circuit breaking plugs, receptacles, cord connectors and motor plugs are used: ɀ to supply power to portable electrical devices such as welders, motors, pumps, conveyors and other similar equipment ɀ where electrical loads must be quickly disconnected from power sources ɀ in areas where severe corrosion hose down, moisture, dirt and dust are problems ɀ indoors and outdoors in non-hazardous areas of chemical plants, sewage treatment facilities, cement plants, pulp and paper plants, food processing plants and other similar industries

Features: ɀ Plugs, receptacles, cord connectors, and motor plugs are molded of Krydon fiberglassreinforced polyester material which is highly resistant to corrosion, heat, weathering and physical abuse 2-stage cord sealing system positively grips cord and protects against environmental contaminants Spring door provides environmental protection of receptacle ɀ Elastomeric snap-on caps provide environmental protection of receptacles and cord connectors ɀ Threaded construction allows quick assembly and disassembly for installation or maintenance Grounding contact circuit is made first and broken last Contact design provides multiple points of electrical contact for full-load circuit breaking capability ɀ Total interchangeability with all existing Arktite products for comparable ratings and configurations Unique environmental sealing system includes o-ring gaskets on all contacts and between housing parts for NEMA 4 integrity Threaded clamping ring provides plug retention Pressure contact wire terminals are standard. Crimp/solder terminals are optional ɀ NPQ motor plugs and NPR cable connectors offer reversed interior capability Unique cord and cable gripping system provides positive strain relief

Interchangeability of Plugs With Other Non-Hazardous and Hazardous Location Receptacles: ɀ Plugs listed for use with NRE/NREA assemblies are standard NPJ Arktite plugs. Other standard APJ and CPH plugs of the

same rating, style and number of poles may be used with NR receptacles, as well as with AR and AREA, receptacles listed in Section 1P, with DR receptacles listed in section 2P, with DBR, NBR, NSR, WSR, CSR, WSQC, and WSRD receptacles listed in Section 3P and with FSQ, EPC, FSQC, W2SR, C2SR and EPCB receptacles listed in Section 4P. ɀ Portable equipment, suitable for locations and equipped with the proper NPJ plug, can be used with non-hazardous AR receptacles; with DBR and WSR interlocked receptacles located in non-hazardous locations; with EPC, EPCB and FSQC receptacles for Class I, Groups B, C, D hazardous locations; with DR and DBR receptacles for Class II, Groups F, G hazardous locations; and with NBR/ NSR, CSR interlocked receptacles for hose down and corrosive locations.

STIBOINFO((CRH:66008com:1P:983))

ɀ Krydon material – natural (gray) ɀ Neoprene – natural ɀ Elastomer – natural ɀ Brass – natural ɀ Leaded red brass – electro-tin-plated ɀ Aluminum – natural ɀ Stainless steel – natural

Grounding: ɀ NPJ plugs are Style 2, which includes a grounding conductor in the flexible cord or cable that is electrically connected to the extra (grounding) pole ɀ NR receptacles are Style 2, in which the ground connection is made before line and load poles engage, and is broken after line and load poles disengage. ɀ The National Electrical Code® and Canadian Electrical Code requires that under conditions favorable to corrosion, the grounding conductor for enclosures and equipment be of copper or other corrosionresistant material in alternating current systems. This necessitates running another conductor, usually of copper, back to the common grounding electrode. This may be run through the conduit containing the circuit conductors. At the receptacle, this grounding conductor should be connected to the extra (grounding) pole by the pressure connector provided for that purpose. Where such an extra ground conductor is required, Style 2 receptacles should be used.

Options: ɀ Alternate polarization (4-pole plugs and receptacles only) – Style 2 – receptacle interior Typical 3-wire, rotated 221⁄2 degrees to 4-pole plug right and plug changed and receptacle to match – add suffix S4 to Cat. No. ɀ Crimp/solder terminals – add suffix T to Cat. No. ɀ Corro-free TM epoxy powder coat on back boxes and angle adapters – information on request

Certifications and Compliances: ɀ UL Standard: 1682 ɀ UL 1010 hazardous locations (NPJ plug only) ɀ Wet and damp locations, watertight ɀ CSA Standard C22.2 No. 182.1

Standard Materials: ɀ Housing, interiors, spring doors, clamping rings – Krydon fiberglass-reinforced polyester material ɀ Gaskets and o-rings – neoprene ɀ Cable clamping basket – nylon ɀ Contacts – pressure – brass; crimp/solder – leaded brass ɀ Snap-on cap – molded elastomer ɀ Back boxes – copper-free aluminum

US: 1-866-764-5454

CH0 1 P - 2 7

Standard Finishes:

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

983

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0984-8 Name: 1P-984

DATE: JAN 19 2006

Time: 6:05:57 PM Operator: JB

COLOR: CMYK

TCP: 15001

Non-Metallic Arktite® Heavy Duty Circuit Breaking Motor Plugs, Plugs & Cord Connectors

1P

Typedriver Name: TS name csm no.: 100

Watertight§ Corrosion-Resistant NEMA 4X

Made of Krydon® Material, 30 A, 60 A and 100 A 600 VAC/250 VDC, 50**–400 hertz Receptacle Assembly

NREA

Amps

Receptacle

Mating Plugs

Snap-on Cap/ Spring Door Cat. #1

Cord Dia.

Motor Plugs

NRE

Hub Size

Snap-on Cap/ Spring Door Cat. #1

2-wire, 3-pole

3⁄4

NRE3322 NRE3323

NR332

0.55–0.70 0.70–0.85

3-wire, 4-pole

3⁄4

1

NRE3422 NRE3423

NR342

2-wire, 3-pole

1 11⁄4

NRE6323 NRE6324

3-wire, 4-pole

11⁄4 11⁄2

2-wire, 3-pole 3-wire, 4-pole

Description

Mating Connectors

Plug Cat. #

Cord Connector Cat. #

Motor Plug Cat. #

NPJ3383 NPJ3384

NPR3363 NPR3364

NPQ338

0.55–0.70 0.70–0.85

NPJ3483 NPJ3484

NPR3463 NPR3464

NPQ348

NR632

0.75–1.07 1.07–1.35

NPJ6384 NPJ6385

NPR6364 NPR6365

NPQ638

NRE6424 NRE6425

NR642

0.75–1.07 1.07–1.35

NPJ6484 NPJ6485

NPR6464 NPR6465

NPQ648

11⁄4 11⁄2

NREA10324‡ NREA10325‡

NR1032

0.93–1.21 1.21–1.50

NPJ10386 NPJ10387

NPR10366 NPR10367

NPQ1038

11⁄2 2

NREA10425‡ NREA10426‡

NR1042

0.93–1.21 1.21–1.50

NPJ10486 NPJ10487

NPR10466 NPR10467

NPQ1048

1

30

60

100

1 Krydon Arktite Receptacles are supplied with both a spring door and snap-on cap. § Wet and damp locations when used with spring door or snap-on cap, watertight when used with QE threaded cap. ‡ AJ back boxes are square, making it possible to install with hub in several positions. ** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

984

STIBOINFO((CRH:66008com:1P:984)) CH0 1 P - 2 9

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0985-4 Name: 1P-985

DATE: JAN 19 2006

Time: 6:05:59 PM Operator: JB

COLOR: CMYK

Non-Metallic Arktite® Heavy Duty Circuit Breaking Motor Plugs, Plugs & Cord Connectors

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions

1P

Made of Krydon® Material, 30 A, 60 A and 100 A 600 VAC/250 VDC, 50**–400 hertz

Fig. 1 – 30 A Receptacle Assemblies

Fig. 2 – 60 A Receptacle Assemblies

Fig. 3 – 60 and 100 A Receptacle Assemblies

NRE 30 and 60 A Assemblies – Fig. 1 NREA 60 and 100 A Assemblies – and 2 Fig. 3 Hub Size 3⁄4 1 11⁄4 11⁄2

Dimension a

Dimension b

30 A 13⁄16 15⁄16

30 A 17⁄8 2

60 A 15⁄16 13⁄16 15⁄16

60 A 29⁄16 25⁄8 211⁄16

60 A Hub Size 1, 11⁄4, 11⁄2 9 11 115⁄16

Dim. a b c

100 A Hub Size 11⁄4, 11⁄2 2 91⁄4 913⁄16 12 12 19⁄16 19⁄16 Fig. 6 – NPQ Motor Plugs

Fig. 7 – NPJ Plugs Fig. 4 – Spring Door Housings

Amps

Fig. 5 – Housings with Cap

30

No. Poles 3 or 4 3 or 4

Housing Spring Door Open

a 31⁄4 213⁄16

b 33⁄8 33⁄8

c — 29⁄16

d 23⁄4 23⁄4

e 12-24 12-24

Spring Door Spring Door Open Open

41⁄2 41⁄2 41⁄16 41⁄16

41⁄4 41⁄4 41⁄4 41⁄4

— — 215⁄16 31⁄4

31⁄2 31⁄2 31⁄2 31⁄2

5⁄16-18

60

3 4 3 4

Spring Door Spring Door Open Open

53⁄4 53⁄4 55⁄16 55⁄16

41⁄4 41⁄4 41⁄4 41⁄4

— — 33⁄16 37⁄16

31⁄2 31⁄2 31⁄2 31⁄2

5⁄16-18

100

3 4 3 4

Fig. 8 – NPR Cord Connectors

5⁄16-18 5⁄16-18 5⁄16-18

5⁄16-18 5⁄16-18 5⁄16-18

Amps/Poles a b NPQ Motor Plugs – Fig. 6 33⁄8 30/3 or 4 23⁄4 60/3 or 4 31⁄2 41⁄4 100/3 or 4 31⁄2 41⁄4 NPJ Plugs – Fig. 7 7 30/3 or 4 81⁄2 60/3 91⁄2 613⁄16 60/4 91⁄2 613⁄16 73⁄4 100/3 111⁄4 73⁄4 100/4 111⁄4 NPR Cord Connectors – Fig. 8 29⁄16 30/3 or 4 87⁄8 60/3 93⁄4 215⁄16 60/4 93⁄4 31⁄4 100/3 111⁄2 33⁄16 100/4 111⁄2 37⁄16

c 215⁄16 45⁄16 57⁄16 33⁄16 35⁄8 4 4 41⁄4 25⁄8 215⁄16 215⁄16 35⁄16 35⁄16

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:985)) CH0 1 P - 3 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

985

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0986-4 Name: 1P-986

1P

100: DATE: JAN 19 2006

Time: 6:06:58 PM Operator: RB

Configured Arktite® Heavy Duty Power Connectors

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Rainproof 30 to 100 A 600 VAC/250 VDC 60-400 hertz

Heavy-Duty and Voltage Polarized Configured Arktite® Power Connectors offer the heavy-duty metal construction of our standard Arktite line, plus voltage configuration. This combination is the ultimate in pin and sleeve connector reliability and safety. The new Configured Arktite Connector series incorporates a unique voltage polarization system that insures that only receptacles and plugs rated for the same voltage can be physically connected. This assures a safe and correct electrical connection every time. Compliance with the National Electrical Code® article 210-7 requirement for non-interchangeability of receptacles and plugs on the same premises with different voltages is now easier than ever. Equipment damage due to the misapplication of the wrong voltage using these connectors when properly installed can be virtually eliminated. This new connector series is not intermateable with our standard line of Arktite power connectors, but it utilizes many of the same time-tested construction features that have been the proven standard of excellence in the electrical industry for years. Configured Arktite Power Connectors are available in 4 or 5 pole (includes ground contact) versions for 30, 60, or 100 amp requirements. Every plug and receptacle is marked numerically and color coded for the specific voltage making it simple and easy to determine the proper plug and receptacle combination. A larger ground contact and unique keying system insures that only the connectors of the same voltage

will intermate. Five distinct configurations are available covering the most common voltages in industry. Configured Arktite Power Connectors are designed for rugged use in the most abusive applications. The unique gasketing system provides a sure seal even in the most adverse environments. They also feature the Cooper Crouse-Hinds patented TRI-LOCK TM cable grip that securely locks the cable in place even when subjected to extreme flexing and jerking. The larger ground contact makes first, breaks last, and is bonded to the metal housing

to insure all metal parts are properly grounded. The power contacts are specially designed and located in arc quenching chambers to allow these connectors to be safely disconnected under load. Cooper Crouse-Hinds Configured Arktite Power Connectors are designed in compliance with the latest UL, CSA and NEMA standard.

Applications: Configured Arktite voltage polarized circuit breaking plugs and receptacles are used: ɀ to supply power to portable electrically operated devices such as motor-generator sets, compressors, heating and cooling units, welders, conveyors, lighting systems, and similar equipment. ɀ where temporary power is needed, such as at trailers, building units, heavy machinery, and similar equipment. ɀ wherever electrical loads must be quickly disconnected from a power source. ɀ in areas where dust, dirt, moisture, and corrosion are a problem. ɀ indoors and outdoors in non-hazardous areas of chemical plants, process industry facilities, meat packing plants, manufacturing plants, and similar industrial locations.

Accessories: Accessories include a variety of angle adapters, panel adapters, and back boxes for Configured Arktite receptacles. They include protective caps for Configured Arktite plugs and receptacles.

986

STIBOINFO((CRH:66008com:1P:986)) CH0 1 P - 1 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0987-4 Name: 1P-987

DATE: JAN 19 2006

Time: 6:06:59 PM Operator: RB

Configured Arktite® Heavy Duty Power Connectors

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Rainproof 30 to 100 A 600 VAC/250 VDC 60-400 hertz

1P

Voltage/Color Configurations A 16 position ‘face’ is used to illustrate the grounding contact location for receptacles. To identify the system voltage, identify the housing color and position of the receptacle grounding contact or marking on the polarizer.

Standard Materials: ɀ Metallic receptacle housings, plug, and connector bodies – high impact strength copper-free aluminum ɀ Back boxes – cast aluminum ɀ Insulators: 3, 4, and 5 pole – fiberglass-reinforced polyester ɀ Contacts: Pressure screw type – brass ɀ Polarizers – PBT polyester

Standard Finishes: ɀ Aluminum – natural ɀ Fiberglass-reinforced polyester insulator – gray ɀ Brass – natural

Certifications and Compliances: ɀ UL Standards: 1682 and 1686 ɀ CSA Standard: C22.2 No. 182.1

Electrical Rating Ranges: ɀ Voltage – 600 VAC; 60 to 400 hertz; 250 VDC ɀ Amperes – 30, 60, and 100 ɀ Horsepower Rating – same as standard product. See page 969.

Typical Installation:

Catalog Numbering System: Ordering Configured Arktite is easy.

AR APJ APR APQ

⍧ Arktite Receptacle ⍧ Arktite Plug ⍧ Arktite Connector ⍧ Arktite Motor Plug

AR

Configured

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:987)) CH0 1 P - 1 9

C

3

4

3 ⍧ 30 Amps 6 ⍧ 60 Amps 10 ⍧ 100 Amps

CAN: 1-800-265-0502

C 4 ⍧ 4 Poles 5 ⍧ 5 Poles

C ⍧ 208Y/120 VAC (Blue) E ⍧ 240 VAC 1X or 3X (Blue) K ⍧ 208 VAC 3X (Dark Blue) P ⍧ 480 VAC 1X or 3X (Red) W ⍧ 600 VAC 3X (Black)

Copyright© 2006 Cooper Crouse-Hinds

987

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0988-11 Name: 1P-988

100: DATE: JAN 19 2006

Time: 6:07:01 PM Operator: RB

Configured Arktite® Heavy Duty Power Connectorsɍ

1P

COLOR: CMYK

TCP: 15001

Rainproof 30/60 A 600 VAC/250 VDC 60-400 hertz

30 Amp Plugs, Receptacles, Connectors, Motor Plugs Heavy-Duty Voltage Polarized Circuit Breaking NEMA 3R Rainproof UL/CSA

Amps 30 30 30 30 30

Poles 4 4 4 4 5

Volt Rating 208 VAC 3X 240 VAC 3X 480 VAC 3X 600 VAC 3X 208Y/120 VAC

Color Dark Blue Blue Red Black Blue

Plug Cat. No. APJC34K APJC34E APJC34P APJC34W APJC35C

Receptacle w/Spring Door* Cat. No. ARC34K ARC34E ARC34P ARC34W ARC35C

Back Box Ordering Information – See pages 990 and 991. 60 Amp Plugs, Receptacles, Connectors, Motor Plugs Heavy-Duty Voltage Polarized Circuit Breaking NEMA 3R Rainproof UL/CSA

Amps 60 60 60

Poles 4 4 5

Volt Rating 480 VAC 3X 600 VAC 3X 208Y/120 VAC

Color Red Black Blue

Plug Cat. No. APJC64P APJC64W APJC65C

Receptacle w/Spring Door* Cat. No. ARC64P ARC64W ARC65C

Back Box Ordering Information – See pages 990 and 991. ɍ Configured Interlocks are available. – See page 1027.

988

STIBOINFO((CRH:66008com:1P:988)) CH0 1 P - 2 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0989-13 Name: 1P-989

DATE: JAN 19 2006

Time: 6:07:06 PM Operator: XX

Configured Arktite® Heavy Duty Power Connectorsɍ

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Rainproof 100 A 600 VAC/250 VDC 60-400 hertz

1P

100 Amp Plugs, Receptacles, Connectors, Motor Plugs Heavy-Duty Voltage Polarized Circuit Breaking NEMA 3R Rainproof UL/CSA

Amps 100 100 100 100 100

Poles 4 4 4 4 5

Volt Rating 208 VAC 3X 240 VAC 3X 480 VAC 3X 600 VAC 3X 208Y/120 VAC

Color Dark Blue Blue Red Black Blue

Plug Cat. No. APJC104K APJC104E APJC104P APJC104W APJC105C

Receptacle w/Spring Door* Cat. No. ARC104K ARC104E ARC104P ARC104W ARC105C

Dimensions ARC RECEPTACLES 30, 60, 100A SPRING DOOR

ARC RECEPTACLES 30, 60, 100A WITH CAP

APJC PLUGS

ARC Receptacles Amps 30 30 60 60 100 100

Housing Spring door w/cap Spring door w/cap Spring door w/cap

A 27⁄8 33⁄16 41⁄4 41⁄2 51⁄4 59⁄16

B 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4 41⁄4

Amps 30 60 100

APJC Plugs A 61⁄2 81⁄2 101⁄8

B 413⁄16 513⁄16 65⁄8

C 215⁄16 33⁄4 41⁄8

C 3 311⁄16 37⁄8

D 223⁄32 223⁄32 31⁄2 31⁄2 31⁄2 31⁄2

E 12-24 12-24 5/16-18 5/16-18 5/16-18 5/16-18

F 3⁄4 9⁄32 13⁄32

ɍ Configured Interlocks are available. – See page 1027.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:989)) CH0 1 P - 2 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

989

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0990-1 Name: 1P-990

100: DATE: JAN 19 2006

Time: 6:07:07 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

AR Back Boxes and Accessories for 20, 30, & 60 A Receptacle Housings

1P

Dimensions Pages 992 and 993

For ARRH and ARRC back boxes

ARRC ARE Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2

20/30 A Cat. # ARE13 ARE23 ARE33

60 A Cat. #

ARE36 ARE46 ARE56

20/30 A Cat. # ARRH13 ARRH23 ARRH33

60 A Cat. #

ARRH36 ARRH46 ARRH56

20/30 A Cat. # ARJ13 ARJ23 ARJ33

990

STIBOINFO((CRH:66008com:1P:990)) CH0 1 P - 2 3

60 A Cat. #

ARRC36 ARRC46 ARRC56

AR 15° Angle Adapter Mounts On

Takes AR Receptacle Housings

Cat. #

ARRH and ARRC back boxes

20 and 30 amp.

AR30

ARRH and ARRC back boxes

60 amp.

AR60

Steel panel or cabinet

60 and 100 amp.

AR610

Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2

20/30 A Cat. # ARD13 ARD23 ARD33

60 A Cat. #

ARD36 ARD46 ARD56

Spring Door Assembly Used With 30 amp, 2, 3 & 4-pole 60 amp, 2 & 3-pole 60 amp, 4-pole 100 amp, 2 & 3-pole 100 amp, 4-pole

Cat. # QE50 QE51 QE52 QE53 QE54

ARJG

ARJ Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2

20/30 A Cat. # ARRC13 ARRC23 ARRC33

ARD

ARRH Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2

Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2

For steel panel or cabinet

60 A Cat. #

ARJ36 ARJ46 ARJ56

Hub Size 1⁄2 3⁄4 1 11⁄4 11⁄2

US: 1-866-764-5454

20/30 A Cat. # ARJG13 ARJG23 ARJG33

60 A Cat. #

Cap and Chain ARJG36 ARJG46 ARJG56

CAN: 1-800-265-0502

Used With 30 amp, 2, 3 & 4-pole 60 amp, 2 & 3-pole 60 amp, 4-pole 100 amp, 2 & 3-pole

Cat. # QE13 QE32 QE34 QE62

100 amp, 4-pole

QE64

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0991-3 Name: 1P-991

DATE: JAN 19 2006

Time: 6:07:09 PM Operator: GK COLOR: CMYK

AJ and AJC Back Boxes with Angle Adapters for 60, 100, 200 & 400 A Receptacle Housings AJX Assemblies and Component Parts For 200 and 400 A Receptacle Housings

TCP: 15001

Typedriver Name: TS name csm no.: 100

Dimensions Pages 992 and 993

1P

AJX Assemblies Back Box with Angle Adapter, 3 Blank Plates and 1 Hub Plate AJ Back Box with 60/100 A Angle Adapter

AJ Back Box with 200/400 A Angle Adapter

Hub Size

400 A Cat. #

2 21⁄2 3 31⁄2 4 5

AJX69 AJX79 AJX89 AJX929 AJX9210 AJX9212

AJX Component Parts For use in making up assemblies with arrangements of hub plates (4 required) other than those listed.

AJC Back Box with 60/100 A AJA Angle Adapter

AJC Back Box with 200 A Angle Adapter

AJ and AJC Back Boxes † 60 & 100A HUB SIZE

TYPE

BOX ONLY

200A

BOX & ADAPTER ASSEMBLY

ONE HUB

AJ56*

AJ37

FEED THRU

AJC56*

AJC37

400A

BOX ONLY

BOX & ADAPTER ASSEMBLY

BOX ONLY

BOX & ADAPTER ASSEMBLY

AJ71*

AJ58

AJ71*

AJ68

AJ82*

AJ69

AJ82*

AJ79

1⍯

ONE HUB

AJ56*

AJ47

FEED THRU

AJC56*

AJC47

Back Box

Angle Adapter

400 A Cat. # AJX99

400 A Cat. # AJ245

11⁄4⍯

ONE HUB

AJ56

AJ57

FEED THRU

AJC56

AJC57

11⁄2⍯

ONE HUB

AJ66

AJ67

FEED THRU

AJC66

AJC67

2⍯

ONE HUB

AJ71

AJ78

FEED THRU

AJC71

AJC78

Hub Plate

21⁄2⍯

ONE HUB

AJ82

AJ89

3⍯ FEED THRU ANGLE ADAPTER

AJA6

AJA1

AJA2

*REDUCER SUPPLIED WITH ASSEMBLY

† AJ and AJC back boxes are square, making it possible to install with hub in several positions. ‡ Use AJ69, AJ79 or AJ89 for cables up to 2 – #350MCM, 3 – #300MCM or 4 – #250MCM. For larger cables, use AJX69, etc., listed under assemblies.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:991)) CH0 1 P - 2 4

CAN: 1-800-265-0502

Hub Size 2 21⁄2 3 31⁄2 4 5

400 A Cat. # YYP96 YYP97 YYP98 YYP99 YYP910 YYP9012

Copyright© 2006 Cooper Crouse-Hinds

Blank Plate 400 A Cat. # YYP900

991

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0992-4 Name: 1P-992

DATE: JAN 19 2006

Time: 6:07:11 PM Operator: GK COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Back Boxes

1P

Dimensions

20, 30 A

60 A AJX Back Body

ARE Cat. # 13 23 33 36 46 56

Rating 20, 30A 20, 30A 20, 30A 60 A 60 A 60 A

Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2

a 127⁄32 127⁄32 131⁄32 29⁄16 25⁄8 211⁄16

400 Amperes

b 11⁄16 13⁄16 15⁄16 15⁄16

13⁄16 15⁄16

Hub Plate Hub Size YYP96 2 YYP97 21⁄2 YYP98 3 YYP99 31⁄2 YYP910 4 YYP9012 5

ARJG Cat. # 13 23 33 36 46 56

Rating 20, 30A 20, 30A 20, 30A 60 A 60 A 60 A

Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2

a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4

b 415⁄32 415⁄32 419⁄32 55⁄8 511⁄16 53⁄4

c 23⁄4 23⁄4 23⁄4 411⁄16 411⁄16 411⁄16

d 41⁄4 41⁄4 41⁄4 51⁄4 51⁄4 51⁄4

h Dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8

e 13⁄8 13⁄8 13⁄8 15⁄8 15⁄8 15⁄8

AJ Angle Adapter

AJ and AJC With 60, 100, 200 and 400 Ampere Angle Adapters Cat. # Rating Size a b 57⁄8 8 37, 47, 57 60, 100 A 1, 11⁄4, 11⁄2 8 67 60, 100A 2 57⁄8 8 103⁄4 58, 68, 78 200 A 11⁄2, 2, 21⁄2 9 115⁄8 69, 79, 89 400 A 2, 21⁄2, 3

992

STIBOINFO((CRH:66008com:1P:992)) CH0 1 P - 3 2

US: 1-866-764-5454

c 77⁄16 8 97⁄8 1113⁄16

CAN: 1-800-265-0502

d 47⁄8 47⁄8 63⁄4 73⁄4

‘‘A’’ 33⁄4 37⁄8 37⁄8 37⁄8 37⁄8 45⁄8

e 7 7 91⁄2 103⁄8

f 15° 15° 45° 45°

Copyright© 2006 Cooper Crouse-Hinds

‘‘B’’ 111⁄16 25⁄16 25⁄16 29⁄16 213⁄16 37⁄16

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0993-3 Name: 1P-993

DATE: JAN 19 2006

Time: 6:07:12 PM Operator: GK COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Back Boxes

1P

Dimensions

ARRC and ARRH Cat. # 13 23 33 36 46 56

Rating 20/30 A 20/30 A 20/30 A 60 A 60 A 60 A

Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2

a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4

b 55⁄16 55⁄16 55⁄16 61⁄2 61⁄2 61⁄2

c 25⁄8 25⁄8 25⁄8 31⁄2 31⁄2 31⁄2

d 49⁄16 49⁄16 49⁄16 53⁄4 53⁄4 53⁄4

e 21⁄4 21⁄4 21⁄4 31⁄8 31⁄8 31⁄8

f Dia. 11⁄32 11⁄32 11⁄32 7⁄16 7⁄16 7⁄16

g 11⁄16 13⁄16 15⁄16 13⁄8 13⁄8 13⁄8

AR30 and AR60 Angle Adapters Cat. # AR30 AR60

Rating 20/30 A 60 A

a 33⁄8 41⁄4

b 41⁄8 415⁄16

ARD Cat. # 13 23 33 36 46 56

Rating 20/30 A 20/30 A 20/30 A 60A 60 A 60 A

Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2

a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4

b 55⁄16 55⁄16 55⁄16 71⁄16 71⁄16 71⁄16

c 323⁄32 323⁄32 323⁄32 53⁄4 53⁄4 53⁄4

d 41⁄4 41⁄4 41⁄4 51⁄8 51⁄8 51⁄8

e 127⁄32 127⁄32 127⁄32 23⁄4 23⁄4 23⁄4

f Dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8

g 11⁄16 13⁄16 15⁄16 15⁄16 15⁄16 15⁄16

AR610 Angle Adapter

ARJ Cat. # 13 23 33 36 46 56

Rating 20/30 A 20/30 A 20/30 A 60 A 60 A 60 A

Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2

a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4

b 35⁄8 35⁄8 35⁄8 411⁄16 411⁄16 411⁄16

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:993)) CH0 1 P - 3 3

c 23⁄4 23⁄4 23⁄4 411⁄16 411⁄16 411⁄16

d 45⁄8 45⁄8 45⁄8 5 5 5

CAN: 1-800-265-0502

e 17⁄32 17⁄32 17⁄32 123⁄32 123⁄32 123⁄32

f 55⁄16 55⁄16 55⁄16 63⁄8 63⁄8 63⁄8

h Dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8

Copyright© 2006 Cooper Crouse-Hinds

j 15⁄16 15⁄16 15⁄16 15⁄16 15⁄16 15⁄16

993

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0994-2 Name: 1P-994

1P

100: DATE: JAN 19 2006

Time: 6:07:13 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

AR Arktite® Circuit Breaking Round Flange Receptacle Housings for Panel Mounting

Application: AR round flange receptacle housings are designed specifically for semi-flush mounting in sheet metal panels or cabinets.

Features: ɀ Back boxes are not needed for these receptacle assemblies. ɀ Where wiring behind a panel is exposed and subject to either mechanical injury or contact by personnel, suitable shields or guards should be provided.

APJ Plugs with cable grip, Neoprene bushing and fastening ring

Standard Materials: ɀ Receptacle housings – copper-free aluminum ɀ Plug exteriors – copper-free aluminum ɀ Insulation: 30, 60, 100, 200 ampere – fiberglass-reinforced polyester ɀ Pressure and solder contacts – brass ɀ Crimp/solder contacts – leaded red brass

AR Receptacle housings with round flange and threaded cap

AP Plugs with cable grip, Neoprene bushing and fastening ring

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate

Options: Available with these assemblies are: ɀ Reversed interiors (add suffix S22 to Cat. No.) ɀ Special polarity (add suffix S4 to Cat. No.) See page 968 for details.

Certifications and Compliances: ɀ UL Standard: 1682 NOTE: For general information on application, features and grounding, see pages 966 to 969.

994

STIBOINFO((CRH:66008com:1P:994)) CH0 1 P - 3 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0995-2 Name: 1P-995

DATE: JAN 19 2006

Time: 6:07:14 PM Operator: RB

COLOR: CMYK

AR Arktite® Circuit Breaking Round Flange Receptacle Housings for Panel Mounting With Threaded Cap

TCP: 15001

Typedriver Name: TS name csm no.: 100

Weatherproof

1P

30/60/100/200 A, 600 VAC/250 VDC, AP and APJ Plugs Amps

30

Style‡ Description 3-wire, * 1 3-pole 4-wire, * 4-pole 2 3-wire, * 4-pole

} } }

3-wire, 3-pole 4-wire, 4-pole 3-wire, 4-pole

}* }* }*

3-wire, 3-pole 4-wire, 4-pole 3-wire, 4-pole

}* }* }*

1

3-wire, 3-pole

}

2

2-wire, 3-pole

}

1 60 2

1 100 2

200

Recept. Cat. #

Cable Dia.

Plug Cat. #

AR6337

0.60 to 1.20

APJ3375

AR6347

0.60 to 1.20

APJ3475

AR6348

0.60 to 1.20

APJ3485

AR6637

0.75 to 1.45

APJ6375

AR6647

0.75 to 1.45

APJ6475

AR6648

0.75 to 1.45

APJ6485

AR61037

1.00 to 1.70

APJ10377

AR61047

1.00 to 1.70

APJ10477

AR61048

1.00 to 1.70

APJ10487

⎧ .875 to 1.375 AR62031ɍ ⎨ ⎩ 1.875 to 2.500 ⎧ .875 to 1.375 AR62032ɍ ⎨ ⎩ 1.875 to 2.500

AP20355 AP20358 AP20365 AP20368

‡ Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. ɍ 200 ampere size is provided with clamp cover. * Pressure connectors are standard. Crimp/solder type terminators are optionally available for 2, 3 and 4-pole 30 ampere, 3 and 4-pole 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug) AR6337-T (Receptacle)

Dimensions

AR Round Flange Receptacles Description

a

b

c

30 amp. 2, 3, 4-pole 60 amp. 2, 3-pole 60 amp. 4-pole 100 amp. 2, 3-pole 100 amp. 4-pole 200 amp. 3-pole

2

12-24

43⁄4

d 27⁄16

e 15⁄8

f 21⁄4

2

12-24

43⁄4

213⁄16

17⁄8

33⁄8

2

12-24

43⁄4

31⁄8

17⁄8

33⁄8

2

12-24

43⁄4

31⁄16

17⁄8

49⁄16

2

12-24

43⁄4

35⁄16

17⁄8

49⁄16

33⁄8

3⁄8-16

73⁄4

43⁄16

27⁄8

51⁄8

AP 200A Plugs

APJ 30, 60 and 100A Plugs

Amps 30 60 60 100 100 200

No. Poles 2, 3 or 4 2 or 3 4 2 or 3 4 3

a 61⁄2 81⁄2 81⁄2 101⁄8 101⁄8 143⁄4

b 413⁄16 53⁄4 513⁄16 69⁄16 65⁄8 1011⁄16

c 215⁄16 35⁄8 33⁄4 33⁄4 41⁄8 63⁄4

† These dimensions are approximate and vary with cable size.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:995)) CH0 1 P - 3 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

995

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0996-3 Name: 1P-996

1P

100: DATE: JAN 19 2006

Time: 6:07:15 PM Operator: RB

COLOR: CMYK

APQ Arktite® Circuit Breaking Motor Plugs

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4 Watertight

APJ Plugs, APR Cable Connector Receptacles 30/60/100 A, 250 VDC/600 VAC, 50**-400 hertz

Application: APQ motor plugs are used: ɀ on portable electric equipment

Features: ɀ Eliminates problem of storing and protecting a long length of portable cord and plug on portable device ɀ Connection to fixed receptacle used as power source is made with cord sets which may be hung on wall, out of the way ɀ Cord sets are made up using an APR receptacle at one end and an APJ plug at the other ɀ Cord sets may be used singly or connected together to provide longer lengths when needed ɀ With spare cord sets on hand, portable equipment may be kept in service while normal cord replacement is being made ɀ Where design of portable equipment permits, APQ motor plugs can be attached directly to a sheet metal panel or cabinet ɀ May be mounted on AR and AJ back boxes for conduit connection ɀ See typical installation diagram on page 997

APR Cable connector receptacles with cable grip, Neoprene bushing, and protected contacts.

APQ Motor plugs with square flange, gaskets, fastening ring, and exposed contacts.

APJ Plugs with cable grip, Neoprene bushing, exposed contacts, and fastening ring.

Standard Materials: ɀ Motor plugs: mounting plate – Feraloy®, Iron Alloy; protective sleeve – copper-free aluminum ɀ Plug and receptacle exteriors – copper-free aluminum ɀ Back boxes – copper-free aluminum ɀ Insulation – fiberglass-reinforced polyester ɀ Pressure and solder contacts – brass ɀ Crimp/solder contacts – leaded red brass

Amps

Style‡

1 30

Standard Finishes: ɀFeraloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate

2

1

Options: Available with these assemblies: ɀ Special polarity (add suffix S4 to Cat. No.) See page 968 for details.

60

2

Certifications and Compliances: ɀ UL Standards: 514, 1682 ɀ CSA Standard C22.2 No. 182.1 NOTE: For general information on application, features and grounding, refer to pages 966 to 969.

1 100

‡ Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. * Pressure connectors are standard. Crimp/solder terminators are optionally available for 2, 3 and 4 pole 30 ampere. 3 and 4-pole 60 and 100 ampere. For details, see page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APR3355-T (Connector) APJ3375-T (Plug)

2

Description 2-wire, ⎫ * ⎬ 2-pole ⎭ 3-wire, ⎫ * 3-pole ⎬⎭ 4-wire, ⎫ * 4-pole ⎬⎭ 2-wire, ⎫ * 3-pole ⎬⎭ 3-wire, ⎫ * ⎬ 4-pole ⎭ 2-wire, ⎫ * 2-pole ⎬⎭ 3-wire, ⎫ * 3-pole ⎬⎭ 4-wire, ⎫ * 4-pole ⎬⎭ 2-wire, ⎫ * 3-pole ⎬⎭ 3-wire, ⎫ * 4-pole ⎬⎭ 2-wire, ⎫ ⎬ 2-pole ⎭ 3-wire, ⎫ ⎬ 3-pole ⎭ 4-wire, ⎫ ⎬ 4-pole ⎭ 2-wire, ⎫ ⎬ 3-pole ⎭

* * * *

3-wire, ⎫ * ⎬ 4-pole ⎭

Cable Dia. 0.60 to 0.88 0.87 to 1.02 0.60 to 0.88 0.87 to 1.02 0.60 to 0.88 0.87 to 1.02

Cable Connector Receptacle Cat. # APR3253 APR3255 APR3353 APR3355 APR3453 APR3455

APJ3385

0.60 to 0.88 0.87 to 1.02

APR3363 APR3365

APQ338

APJ3485

0.60 to 0.88 0.87 to 1.02

APR3463 APR3465

APQ348

0.75 to 0.88 0.87 to 1.37 0.75 to 0.88 0.87 to 1.37 0.75 to 0.88 0.87 to 1.37 0.75 to 0.88 0.87 to 1.37

APR6253 APR6255 APR6353 APT6355 APR6453 APR6455 APR6363 APR6365

0.75 to 0.88 0.87 to 1.37

APR6463 APR6465

1.00 to 1.38 1.37 to 1.50 1.00 to 1.38 1.37 to 1.50 1.00 to 1.38 1.37 to 1.50 1.00 to 1.38 1.37 to 1.50

APR10255 APR10257 APR10355 APR10357 APR10455 APR10457 APR10365 APR10367

1.00 to 1.38 1.37 to 1.50

APR10465 APR10467

Plug Cat. # APJ3275 APJ3375 APJ3475

APJ6275 APJ6375 APJ6475 APJ6385 APJ6485 APJ10277 APJ10377 APJ10477 APJ10387 APJ10487

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

996

STIBOINFO((CRH:66008com:1P:996)) CH0 1 P - 3 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Motor Plug Cat. # APQ327 APQ337 APQ347

APQ627 APQ637 APQ647 APQ638 APQ648 APQ1027 APQ1037 APQ1047 APQ1038 APQ1048

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0997-1 Name: 1P-997

DATE: JAN 19 2006

Time: 6:07:16 PM Operator: RB

COLOR: CMYK

TCP: 15001

Weatherproof

Typical Back Boxes

Typedriver Name: TS name csm no.: 100

1P

®

For APQ Arktite Circuit Breaking Motor Plugs

Typical back boxes used with APQ motor plugs

ARE

AJ

For APQ 30 Amp.

For APQ 60 and 100 Amp.

Hub Size 1⁄2 3⁄4 1

Hub Size 1 11⁄4 11⁄2 2

Cat. # ARE13 ARE23 ARE33

For APQ 60 Amp. Hub Size 1 11⁄4 11⁄2

Cat. # AJ37 AJ47 AJ57 AJ67

Cat. # ARE36 ARE46 ARE56

Dimensions Typical installation

APQ Motor Plugs Amps. a 30 23⁄4 60 31⁄2 100 31⁄2 (2 & 3-pole)

b 33⁄8 41⁄4 41⁄4

c 35⁄8 47⁄8 61⁄8

s 12-24 5⁄16-18 5⁄16-18

31⁄2

41⁄4

67⁄16

5⁄16-18

100 (4-pole)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:1P:997)) CH0 1 P - 3 9

For additional back box listings, see pages 990 and 991. For back box dimensions, see pages 992 and 993.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

997

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-0998-1 Name: Note Page-998

DATE: JAN 19 2006

Time: 6:07:17 PM Operator: RB

COLOR: CMYK

Notes Page

998

STIBOINFO((CRH:66008com::998)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-0999-2 Name: 2P-999

100: DATE: JAN 19 2006

Time: 6:07:18 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Arktite® Plugs and Receptacles Industrial Heavy Duty Hazardous

2P

Description

Page No.

Application/Selection

1000, 1001

Arktite® Delayed Action Circuit Breaking Technical Data 20 & 30A CPS Receptacle 20 & 30A CPP Plug 20A CPR Connector

1002, 1003 1004, 1005 1004, 1005 1006

NEMA Interlocked/Circuit Breaking Technical Data 15 & 20A Receptacles & Plugs

GFCI

1007 1008, 1009 1010

Delayed Action/Circuit Breaking Technical Data 7 thru 60A CES/CESD Receptacles CPH Plugs

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:999)) CH0 0 0 0 2 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1011, 1012 1013 1013

999

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1000-2 Name: 2P-1000

100: DATE: JAN 19 2006

Time: 6:07:18 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Plugs and Receptacles For Industrial Heavy Duty Hazardous Area Use

2P

Application and Selection Application: ɀ To connect portable or movable electrical equipment, such as motors, motor-generator sets, tools, light systems.

Considerations for Selection: Environmental: ɀ The environment of the enclosure location in terms of NEC/CEC compliance. ɀ Material and construction to withstand rough usage and atmospheric conditions. Electrical:† ɀ Sufficient current carrying capacity to meet load requirements. ɀ Compatibility with electrical system (new or existing installation). ɀ Interchangeability of plugs with other hazardous and non-hazardous area receptacles. See ‘‘Quick Selector’’ below and ‘‘Interchangeability Chart’’ on page 1001 for guidance.

Options: Special polarity arrangements available as options, as well as special back boxes and hub arrangements for some series. See listing pages for details.

Quick Selector Chart Receptacle Series

NEC Compliances

Electrical Rating† Poles

Amps & Volts

Mating Plug

CES, CESD

Cl. I, Division 1 and 2, Groups C,D

2-wire, 3-pole 3-wire, 4-pole

30A, 120-240VAC 7A, 460VAC1

CPH

60A, 115-230VAC 30A, 460VAC1 CPR

Non-Hazardous

2-wire, 3-pole

20A, 125-250VAC 20A, 18VDC

CPP

CPS

Cl. I, Division 1 and 2, Groups C,D

2-wire, 3-pole

20A, 125-250VAC 20A, 18VDC 30A, 125-250VAC 7A, 480VAC1

CPP

3-wire, 4-pole

30A, 125-250VAC 7A, 460VAC1

CPP

Cl. II, Division 1 and 2, Groups F,G

2-wire, 2-pole 2-wire, 3-pole 3-wire, 3-pole 3-wire, 4-pole 4-wire, 4-pole

30A, 480VAC

APJ, NPJ*

Cl. II, Division 1 and 2, Groups F,G

2-wire, 3-pole 3-wire, 3-pole 3-wire, 4-pole 4-wire, 4-pole

60A, 480VAC

APJ, NPJ*

Cl. I, Division 1 and 2, Groups C,D

2-wire, 3-pole 3-wire, 4-pole

60A, 480VAC

APJ, NPJ*

Cl. I, Division 1 and 2, Groups B,C,D Cl. II, Division 1 and 2, Groups F,G Cl. III

NEMA 5&6 Config.

20A, 125VAC 20A, 250VAC

ENP

DR

ENR

WARNING: CPR Arktite® cable connectors are for use in non-hazardous areas only. † If higher ratings are needed, refer to receptacles interlocked with safety switches and circuit breakers in Section 4P. * NPJ plug is available in 2-wire, 3-pole and 3-wire, 4-pole ratings. 1 CSA certified units are rated at 600 VAC.

1000

STIBOINFO((CRH:66008com:2P:1000)) CH0 0 2 P - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1001-1 Name: 2P-1001

100: DATE: JAN 19 2006

Time: 6:07:19 PM Operator: RB

COLOR: CMYK

TCP: 15001

Plugs and Receptacles For Industrial Heavy Duty Hazardous Area Use

Typedriver Name: TS name

csm no.: 100

2P

Interchangeablility Chart Interchangeability Chart Many of the plugs listed in this section can be used interchangeably with receptacles from other sections, both in hazardous and nonhazardous areas, provided electrical rating and style of plug and receptacle are the same. The following table is a summary of possible combinations. Can be Used with these Receptacle Series

Listed in Section

APJ

AR, NR, NPR DR FSQ, EPC, EPCB, EBBR DBR, WSR, NSR, NBR

1P 2P 4P 3P, 4P

30 and 60 amp. 2-wire, 3-pole 3-wire, 4-pole 30 and 60 amp. 3-wire, 4-pole

CPH

AR, NR, NPR DR FSQ, EPC, EPCB, EBBR DBR, WSR, NBR, NSR

1P 2P 4P 3P, 4P

30 and 60 amp. 2-wire, 3-pole 3-wire, 4-pole 30 and 60 amp. 3-wire, 4-pole

CPP

AR, NR, NPR

1P

DBR, WSR, NBR, NSR

3P, 4P

30 amp. 2-wire, 3-pole 3-wire, 4-pole 30 amp. 3-wire, 4-pole

Plugs Shown in Section 2P

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1001)) CH0 0 2 P - 1

Plug & Receptacle Electrical Rating

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1001

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1002-1 Name: 2P-1002

2P

100: DATE: JAN 19 2006

Time: 6:07:20 PM Operator: RB

Arktite® Circuit Breaking CPS Receptacles and CPP Plugs

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Groups C,D Explosionproof Wet Locations

Delayed Action Factory Sealed Application: CPS receptacles, angle and straight types, and CPP plugs are used: ɀ with portable electrically operated devices such as motor-generator sets, compressors, conveyors, portable tools, lighting systems and similar equipment ɀ in locations which are hazardous due to the presence of flammable vapors or gases ɀ in damp or corrosive locations ɀ in petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist

Features: ɀ The delayed action feature permits the plug to be used as an emergency push-pull switch ɀ CPS receptacles are equipped with a rotating mechanism which prevents complete withdrawal of the CPP plug in one continuous movement. Details of operation are illustrated and explained below

Fig. 1

Figure 1 shows a CPS angle type receptacle assembly with CPP plug fully engaged. Figure 2 shows the plug withdrawn until it is stopped by the delayed action mechanism. In this position the circuit has been broken and the arc has been snuffed in the contact chambers. To completely withdraw the plug as shown in Figure 3, the delayed action release lever mush be rotated counterclockwise. The time required to actuate the mechanism permits dissipation of the arc-generated heat before contacts and arcing chambers are opened to the atmosphere. When inserting the plug, the reverse procedure is followed. ɀ CPS receptacles are factory sealed to simplify installation and wiring – external seals are not required ɀ Series 152 receptacles have top hinged cover design, with 45° downward angled receptacle housing, to provide superior environmental protection from accumulations of dust, snow, ice, and water ɀ Back boxes used for angle type receptacles are standard EDS bodies. Assemblies are listed with single and two gang bodies and dead end or through feed hubs – 1⁄2⍯ to 1⍯ sizes ɀ Back boxes used for straight type receptacles are available with a variety of hub arrangements in 1⁄2⍯ and 3⁄4⍯ sizes ɀ All receptacles and 30 ampere plugs are provided with pressure terminals for ease of field wiring. 20 ampere plugs have solder terminals.

Grounding:

Fig. 2

ɀ NEC Article 501 and CEC Part 1 Section 18 requires that metal frames or exposed noncurrent-carrying metal parts of portable devices used in hazardous locations be grounded through an extra conductor in the portable cord ɀ CPS receptacles and CPP plugs are provided with an extra grounding pole ɀ In plugs, provision is made for attachment of the grounding wire to the grounding pole. In addition, direct connection is provided between plug and receptacle housings and the grounding pole. In the receptacle, grounding is accomplished through the conduit system

Standard Materials: ɀ Receptacle housings – die cast copper-free aluminum ɀ EDS Back boxes – Feraloy® iron alloy (U.S.)/Copper-free aluminum (Canada) ɀ Other back boxes – Feraloy iron alloy ɀ Plug exteriors – copper-free aluminum or Krydon® fiberglass-reinforced polyester material. See listings ɀ Insulation – all receptacles and plugs – Krydon fiberglass-reinforced polyester material ɀ Pressure or solder contacts – brass ɀ Crimp/solder contacts – leaded red brass

Standard Finishes: ɀ Copper-free aluminum – aluminum acrylic paint. ɀ Feraloy – electrogalvanized and aluminum lacquer ɀ Fiberglass-reinforced polyester – natural (red, white) ɀ Brass – natural ɀ Leaded red brass – electro-tin-plate

Electrical Rating Ranges: ɀ Angle type – 20 and 30 amperes; 125 and 250 VAC ɀ Straight type – 20 amperes; 125 and 250 VAC

Certifications and Compliances: ɀ NEC/CEC: Class I, Division 1 and 2, Groups C,D ɀ UL Standard: 1010 ɀ CSA Standard C22.2 No. 30

Interchangeability of Plugs with Non-Hazardous Location Receptacles:

Fig. 3

1002

STIBOINFO((CRH:66008com:2P:1002)) CH0 0 2 P - 2

ɀ 30 ampere CPP plugs can also be used with standard 30 ampere AR Arktite receptacles of the same style and number of poles, thus permitting portable devices suitable for use in hazardous locations to be connected to receptacles in both hazardous and non-hazardous areas NOTE: Equipment to be used in hazardous areas must be suitable for use in the specific hazardous location.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1003-1 Name: 2P-1003

DATE: JAN 19 2006

Time: 6:07:21 PM Operator: RB

Arktite® Circuit Breaking CPS Receptacles and CPP Plugs

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Groups C,D Explosionproof Wet Locations

csm no.: 100

2P

Delayed Action Factory Sealed Options: ɀ Material: copper-free aluminum, natural finish, is available on certain back boxes. See listings. Add suffix SA to Cat. No.

* The following special options are available from factory by adding suffix to Cat. No. Suffix to be Added to Description Cat. # Receptacle interior rotated 221⁄2 degrees to right (viewed from face) and plug changed to match. 30 ampere units only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4 Combination of receptacles and EFS/EFD or EDS series devices, such as pilot lights, switches, push button stations, etc., can be furnished using three, four and five gang bodies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specify Hub arrangements other than those listed can be supplied . . . . . . . . . . . . . . . . . . . . . . . . . . Specify

Dimensions

Straight type receptacles Series 152

20 Ampere plugs Cat. # CPP516 CPP512

a† 83⁄8 7

b† 67⁄8 51⁄2

C 13⁄4 13⁄4

d 19⁄16 19⁄16

† These dimensions are approximate and vary with cable size.

Series 532 and 732

Angle type receptacles a = 31⁄2 for single gang 73⁄16 for two gang

30 Ampere plugs

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1003)) CH0 0 2 P - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1003

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1004-1 Name: 2P-1004

2P

DATE: JAN 19 2006

Time: 6:07:22 PM Operator: RB

Arktite® Circuit Breaking CPS Receptacles and CPP Plugs

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Groups C,D Explosionproof Wet Locations

Delayed Action Factory Sealed

CPS152R – Receptacle unit only CPS152 – Single gang angle type

CPS152 – Two gang angle type

CPP plugs with mechanical cable grip and Neoprene bushing

Style 2 – Grounded through extra pole and shell

Rating

20A, 1 HP, 125-250VAC, 60 hertz, 20A, 18VDC 30A, 11⁄2 HP, 125-250VAC, 60 hertz, 7A, 1⁄2 HP, 480VAC1, 60 hertz 30A, 3 HP, 125-250VAC, 60 hertz, 7A, 1 HP, 480VAC1, 60 hertz

Description Dead End

Single Gang Receptacle Hub Assembly Size Cat. # 1⁄2 3⁄4

1

Two Gang Receptacle Assembly Cat. #

Through Feed Dead End

3⁄4

1 1⁄2 3⁄4

1

Through Feed Dead End

3⁄4

1 1⁄2 3⁄4

1

Through Feed

3⁄4

1

STIBOINFO((CRH:66008com:2P:1004)) CH0 0 2 P - 4

US: 1-866-764-5454

CPP516ɍ CPP512 ɍ

CPS152R

}

† .375 to .875

CPP4553

CPS532R

}

† .375 to .875

CPP4752

CPS732R

CPS532-111 CPS532-211 CPS532-311 CPS732-101 CPS732-201 CPS732-301

CPS532-112 CPS532-212 CPS532-312 CPS732-102 CPS732-202 CPS732-302

CPS732-111 CPS732-211 CPS732-311

CPS732-112 CPS732-212 CPS732-312

* Back boxes are available in copper-free aluminum. To order, add suffix SA to the Cat. No. 1 CSA certified units are rated at 600 VAC at 7A.

1004

† .312 to .625

CPS152-112* CPS152-212* CPS152-312* CPS532-102 CPS532-202 CPS532-302

3-wire, 4-pole 1⁄2

}

CPS152-111* CPS152-211* CPS152-311* CPS532-101 CPS532-201 CPS532-301

2-wire, 3-pole 1⁄2

Plug With High Impact Molded Composition Receptacle Handle Unit only Cat. # Cat. #

CPS152-101* CPS152-102* CPS152-201* CPS152-202* CPS152-301* CPS152-302*

2-wire, 3-pole 1⁄2

Cable Dia.

Plug With Aluminum Handles Cat. #

CAN: 1-800-265-0502

† Receptacles will take any of the plugs grouped in the bracket opposite the receptacle listings. ɍ 20 amp plugs are furnished with solder terminations at standard, ground contacts have pressure terminations.

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1005-1 Name: 2P-1005

DATE: JAN 19 2006

Time: 6:08:24 PM Operator: RB

Arktite® Circuit Breaking CPS Receptacles and CPP Plugs

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Groups C,D Explosionproof Wet Locations

csm no.: 100

2P

Delayed Action Factory Sealed

CPS straight type shown with plug Style 2 – Grounded through extra pole and shell 2-wire, 3-pole 20A, 1HP, 125-250VAC, 60-400 hertz, 20A, 18VDC

With aluminum handle

With high impact molded composition handle

CPP Plugs

CPS Dead End Hub Size 1⁄2 3⁄4

Assembly Cat. # CPS14-120 CPS14-20

CPS Receptacle Unit Body Cat. # CPS120 CPS20

With Spring Door

With Mechanical Cable Grip and Neoprene Bushing

Cat. # CPS14R Cable Dia. .312 to .625

Aluminum Cat. # CPP516

Composition Cat. # CPP512

CPS Through Feed Hub Size 1⁄2 3⁄4

Assembly Cat. # CPS14-121 CPS14-21

Body Cat. # CPS121 CPS21

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1005)) CH0 0 2 P - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1005

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1006-3 Name: 2P-1006

2P

100: DATE: JAN 19 2006

Time: 6:08:29 PM Operator: RB

COLOR: CMYK

TCP: 15001

Arktite® CPR Cable Connector Receptacles Delayed Action Circuit Breaking

Application: CPR Arktite delayed action cable connector receptacles are used in non-hazardous areas only*: ɀ to make up adapter sets for connecting portable devices having CPP plugs to receptacles in non-hazardous areas. This is accomplished by equipping one end of the length of cable with the CPR receptacle and the other with a plug to mate with the receptacle in the non-hazardous area. ɀ to make up extension cords using the CPR receptacle at one end and a CPP plug at the other

Features: ɀ Spring door housing with the same delayed action rotating mechanism provided in CPS receptacles listed on pages 1002 through 1005 ɀ Pressure terminals are furnished for ease of wiring ɀ Gland nut with mechanical cable grip and bushing for effective strain relief

Style 2 – Grounded through extra pole and shell. For use with CPP516 and CPP512 series plugs listed on page 1005. Description 2-wire, 3-pole

Rating 20A, 1HP, 125-250VAC, 60 hertz 20A, 18 VDC

Cable Dia.

Cat. #

.375 to .625

CPR154

Standard Materials: ɀ Housing – copper-free aluminum ɀ Insulation – fiberglass-reinforced polyester ɀ Contacts – brass

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Brass – natural

* CSA certified unit suitable for Class I Groups C and D (not available in USA).

1006

STIBOINFO((CRH:66008com:2P:1006)) CH0 0 2 P - 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1007-1 Name: 2P-1007

100: DATE: JAN 19 2006

Time: 6:08:30 PM Operator: RB

ENR Dead Front Interlocked Circuit Breaking Receptacles ENP Plugs General Purpose ArkɀGard® 2; Factory Sealed

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 & 2, Groups B†,C,D Cl. II, Div. 1 & 2, Groups F,G Cl. III NEMA 3,7BCD,9FG,12

Typedriver Name: TS name

Explosionproof Dust-Ignitionproof Raintight Wet Locations

csm no.: 100

2P

Application: ENR receptacles and ENP plugs are used: ɀ with portable electrical equipment such as compressors, tools, lighting systems, and similar devices ɀ in areas made hazardous by the presence of flammable vapors and gases or combustible dusts ɀ wherever portable electrical equipment is likely to be transferred from hazardous to nonhazardous areas ɀ in damp and corrosive areas ɀ when power requirements do not exceed 20 amperes ɀ where general purpose application is required

Features:

ɀ ArkȿGard 2 receptacle incorporates three spring-loaded slide keys that prevent the receptacle face plate from being rotated until the ENP plug is fully inserted into the receptacle. To make the connection, the ENP plug is fully inserted; and the receptacle face moved inward by pushing the plug forward (Fig. 1). The plug is then rotated, (Fig. 2), closing the circuit. As rotation begins, the plug becomes locked in the receptacle and cannot be accidentally disengaged. In making or breaking the circuit, any resulting electrical arc is confined in the factory-sealed chamber. ɀ Factory-sealed chamber encloses the potential arcing components between two explosion-proof threaded joints. These threads are specially coated to guarantee freedom of movement, which ensures on-off action. No additional seals are required. ɀ One piece molded gasket seals cover plate and ENP plug when plug is inserted, providing full environmental protection at the receptacle face. ɀ Top-hinged cover design with 45° downward angle provides superior protection in damp, wet, and dirty locations. ɀ Molded-in contact design provides superior interior contact reliability. ɀ ENP plugs can be used in nonhazardous areas with standard U-ground NEMA/EEMAC configuration 5 and 6 receptacles, eliminating the need for two separately equipped portable units of the same type. The ENR receptacle will not accept standard NEMA/ EEMAC configuration plugs. ɀ ENP plug handle body is designed with an internal cord strain relief mechanism and a cable sealing grommet which will accept various cable diameters. ɀ Field assembly is accomplished with standard tools. ɀ Use standard EDS back boxes.

Figure 2

Figure 1

Grounding: ɀ NEC Article 501 and CEC Section 18 requires that metal frames or exposed noncurrent-carrying metal parts of portable devices used in hazardous locations be grounded through an extra conductor in the portable cord. ENR receptacles and ENP plugs are provided with an extra grounding pole.

Standard Materials: ɀ Receptacle housing, spring door and plug body – die cast copper-free aluminum ɀ Interiors: receptacle – Krydon® fiberglassreinforced polyester material; plugs – nylon 100 ɀ Contacts: receptacle blade – brass; receptacle switch – silver; plug – brass ɀ Receptacle cover hinge pin and spring – stainless steel ɀ Receptacle gasket – neoprene ɀ Plug bushing – neoprene

Standard Finishes: ɀ Copper-free aluminum – aluminum acrylic paint ɀ Brass – natural

Electrical Rating Ranges: ɀ Receptacles – 20 amperes; 125 vac and 250 vac, 50-400 hertz ɀ Plugs – 15 amperes; 125 vac and 250 vac, 50-400 hertz 20 amperes; 125 vac and 250 vac, 50-400 hertz

Certifications and Compliances: ɀ NEC: Class I, Division 1 and 2, Groups B†,C,D Class II, Division 1 and 2, Groups F,G Class III ɀ ANSI/UL Standard 1010 ɀ NEMA/EEMAC 3,7BCD,9FG ɀ CEC: Class I, Division 1 and 2, Groups B, C, D Class II, Division 1 and 2, Group G Class III CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

Dimensions

† Single gang receptacles purchased as a complete assembly with EDS back box are suitable for Class I, Group B usage. Two gang receptacles can be modified for Class I, Group B usage. Add the letter B to Cat. No. Example: ENRB22201. Seals must be installed within 11⁄2⍯ of each conduit opening. Receptacle units only (ie. ENR5201) are not suitable for Class I, Group B. a=31⁄2 for single gang; 79⁄16 for two gang. US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1007)) CH0 0 2 P - 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1007

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1008-2 Name: 2P-1008

2P

DATE: JAN 19 2006

Time: 6:08:31 PM Operator: RB

ENR Dead Front Interlocked Circuit Breaking Receptacles ENP Plugs General Purpose (For US NEC Applications); ArkȿGard® 2; Factory Sealed

ENR single gang dead end assembly

Receptacle Rating

Description Dead End

ENR single gang dead end assembly with spring door open

Hub Size 1⁄2 3⁄4 1

Single Gang Receptacle Assembly Cat. # ‡ ENR11201 ENR21201 ENR31201

COLOR: CMYK

20 amp, 125 volt

ENR receptacle only, with spring door open Receptacle Unit Only Cat. #

ENP plug

15 Amp NEMA Plug Config. Cat. #

NEMA Config.

ENP5151

Through Feed

3⁄4

1 1⁄2

Dead End

3⁄4

1

ENRC12201 ENRC22201 ENRC32201

ENR11202 ENR21202 ENR31202

ENR12202 ENR22202 ENR32202

20 amp, 250 volt

5-15P

ENP6152

ENR6202 Through Feed

3⁄4

1

ENRC11202 ENRC21202 ENRC31202

NEMA Config.

5-20P

ENP6202

6-20R 1⁄2

20 Amp Plug Cat. #

ENP5201

5-20R ENRC11201 ENRC21201 ENRC31201

Explosionproof Raintight Wet Locations Dust-Ignitionproof

ENR two gang dead end assembly with one spring door open

ENR5201 1⁄2

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1 & 2, Groups F,G Cl. III NEMA 3,7BCD,9FG,12

ENR two gang dead end assembly

Two Gang Receptacle Assmebly Cat. # ‡ ENR12201 ENR22201 ENR32201

TCP: 15001

6-15P

6-20P

ENRC12202 ENRC22202 ENRC32202 * Single gang receptacles purchased as a complete assembly with EDS back box are suitable for Class I, Group B usage. Two gang receptacles can be modified for Class I, Group B usage. Add the letter B to Cat. No. Example: ENRB22201. Seals must be installed within 11⁄2⍯ of each conduit opening. Receptacle units only (ie. ENR5201) are not suitable for Class I, Group B. ‡ With Feraloy

1008

STIBOINFO((CRH:66008com:2P:1008)) CH0 0 2 P - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

®

Iron Alloy EDS, EDSC back boxes.

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1009-1 Name: 2P-1009

DATE: JAN 19 2006

Time: 6:08:33 PM Operator: RB

ENR Dead Front Interlocked Circuit Breaking Receptacles ENP Plugs; General Purpose (For CEC Applications) ArkȿGard® 2; Factory Sealed

ENR single gang dead end assembly

Receptacle Rating

Description Dead End

TCP: 15001

Cl. I, Div. 1 & 2, Groups B*,C,D Cl. II, Div. 1 & 2, Group G Cl. III EFC 3,7BCD,9G,12

ENR single gang dead end assembly with spring door open

Hub Size 1⁄2 3⁄4 1

COLOR: CMYK

Single Gang Receptacle Assembly Cat. # ‡ ENR11151 ENR21151 ENR31151

Explosionproof Raintight Wet Locations Dust-Ignitionproof

ENR two gang dead end assembly Two Gang Receptacle Assembly Cat. # ‡ ENR12151 ENR22151 ENR32151

15 amp, 125 volt

Typedriver Name: TS name

Receptacle Unit Only Cat. #

EEMAC Config.

Plug Cat. #

Through Feed

3⁄4

1 1⁄2

Dead End

3⁄4

1

ENRC12151 ENRC22151 ENRC32151

ENR11152 ENR21152 ENR31152

ENR12152 ENR22152 ENR32152

15 amp, 250 volt

5-15P

ENP6152

ENR6152 6-15A 1⁄2

Through Feed

3⁄4

1 1⁄2

Dead End

3⁄4

1

ENRC11152 ENRC21152 ENRC31152

ENRC12152 ENRC22152 ENRC32152

ENR11201 ENR21201 ENR31201

ENR12201 ENR22201 ENR32201

20 amp, 125 volt

6-15P

ENP5201

ENR5201 5-20R 1⁄2

Through Feed

3⁄4

1 1⁄2

Dead End

3⁄4

1

ENRC11201 ENRC21201 ENRC31201

ENRC12201 ENRC22201 ENRC32201

ENR11202 ENR21202 ENR31202

ENR12202 ENR22202 ENR32202

20 amp, 250 volt

6-20R Through Feed

3⁄4

1

ENRC11202 ENRC21202 ENRC31202

5-20P

ENP6202

ENR6202 1⁄2

EEMAC Config.

ENP5151 5-15R

ENRC11151 ENRC21151 ENRC31151

2P

ENR two gang dead end assembly with one spring door open

ENR5151 1⁄2

csm no.: 100

6-20P

ENRC12202 ENRC22202 ENRC32202

* Single gang receptacle units can be modified for Class 1, Group B usage. Add suffix B to the Cat. No. Example: ENRB11201. Seals must be installed immediately adjacent to each conduit opening. ‡ 15A With Copper-free aluminum EDS, EDSC back boxes. 20A with Feraloy® iron alloy EDS, EDSC back boxes

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1009)) CH0 0 2 P - 9

CAN: 1-800-265-0502

©

Copyright 2006 Cooper Crouse-Hinds

1009

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1010-3 Name: 2P-1010

2P

100: DATE: JAN 19 2006

Time: 6:08:35 PM Operator: RB

GFS ground fault circuit interrupters are used: ɀ with portable electrical equipment such as tools, lighting systems, compressors and similar devices for personnel protection ɀ in areas made hazardous by the presence of flammable vapors, gases or combustible dusts ɀ in branch circuits of 15 to 20 amperes at 125 volts AC ɀ in conjunction with ENR or CPS152 receptacles

TCP: 15001

Cl. I, Div. 1 & 2, Groups C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III NEMA/EFC 7CD,9EFG,12

GFS Ground Fault Circuit Interrupter

Application:

COLOR: CMYK

Application Recommendations:

ɀ NEC/CEC: Class I, Division 1 and 2, Groups C,D Class II, Division 1, Groups E,F,G Class II, Division 2, Groups F,G Class III ɀ ANSI/UL Standard: 943, 1203 ɀ NEMA/EEMAC 7CD, 9EFG, 12 ɀ CSA Standard C22.2 No. 30, 144

GFS-1 can be installed in an EDS back box (pg. 397) for point-of-use protection or for protection of downstream receptacles.

GFS-1 with EDS271 back box

GFS-1 can be used with ENR or CPS receptacles and EDS back box for circuit interrupter protection of portable equipment.

Ordering Information Amps 20

Description Factory-sealed ground fault circuit interrupter – 5 milliampere trip

Cat. # GFS-1

GFS-1 with EDS172 back box and ENR5201 receptacle

Standard Materials: ɀ Cover – sand cast copper-free aluminum ɀ Sealing well – die cast copper-free aluminum ɀ Pushbuttons and guards – stainless steel ɀ Shaft seals – neoprene ɀ Interior – body – polycarbonate; contacts – brass

Dimensions

Standard Finishes: ɀ Copper-free aluminum – aluminum lacquer ɀ Stainless steel – natural ɀ Polycarbonate – natural (ivory) ɀ Brass – natural

Electrical Rating Ranges: ɀ 20 amperes ɀ 125 VAC ɀ 5 milliampere trip setting ɀ Class A per ANSI/UL943

1010

STIBOINFO((CRH:66008com:2P:1010)) CH0 2 P - 1 0

Explosionproof Dust-Ignitionproof

Certifications and Compliances:

Features: ɀ Factory sealed chamber encloses the ground fault circuit interrupter (GFCI) and its potentially arcing components in an enclosure with explosion-proof ground joints. No additional sealing is required when proper body is used. ɀ GFCI protects personnel against possible injury due to unwanted ground faults; meets requirements for personnel protection as defined in the National Electrical Code®. ɀ GFCI is feed-through type to serve several receptacles. ɀ Decentralized GFCI protection on branch circuits permits immediate identification of circuit where a ground fault is occurring; does not interrupt power on total branch circuit if tripped or when periodically tested; significantly reduces incidence of nuisance tripping; provides for use of 125 VAC portable lighting even when working on metal floors or catwalks. ɀ Field installation is accomplished with standard tools. ɀ Can be installed on any Cooper CrouseHinds single or multiple gang EDS or EDSC device box.

Typedriver Name: TS name

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1011-2 Name: 2P-1011

DATE: JAN 19 2006

Time: 6:08:36 PM Operator: RB

CES and CESD Arktite Receptacles Delayed Action Circuit Breaking CPH Plugs

COLOR: CMYK

2P

Interchangeability of Plugs with Non-Hazardous Location Receptacles:

Features: ɀ CES and CESD receptacles are equipped with a delayed action rotating sleeve which prevents complete withdrawal of the CPH plug in one continuous movement ɀ The delayed action feature permits the plug to be used as an emergency push-pull switch ɀ Details of operation are illustrated and described below: Fig. 3

Fig. 4

Figure 4 shows the plug completely withdrawn. To accomplish this, the delayed action sleeve must be rotated counterclockwise. The time required to actuate the mechanism permits dissipation of the arc-generated heat before contacts and arcing chambers are opened to the atmosphere. When inserting the plug, the reverse procedure is followed. ɀ Receptacles are factory sealed to simplify installation and wiring. External seals are not required ɀ The 30 ampere receptacles are provided with pressure terminals for field connection. The 60 ampere receptacles have flexible leads. Plugs are equipped with solder terminals. ɀ Two arrangements are provided for the 3⁄4⍯ and 11⁄4⍯ conduit hubs, as shown in the listings and dimensions on page 1012.

Grounding:

Figure 1 above shows a CES receptacle assembly with CPH plug fully engaged. Figure 2 shows the plug withdrawn until it is stopped by the delayed action sleeve. In this position the circuit has been broken and the arc has been snuffed in the contact chambers. Figure 3 shows the delayed action receptacle sleeve rotated approximately 45° to allow withdrawal of plug from receptacle.

csm no.: 100

ɀ CES and CESD receptacles and CPH plugs are provided with an extra grounding pole for attachment of the grounding wire. In the plugs, provision is made for attachment of the grounding wire to the grounding pole. In addition, direct connection is provided between plug and receptacle housings and the ground pole. In the receptacles, grounding is accomplished through the conduit system.

CES and CESD receptacles with CPH plugs are used: ɀ with portable electrically operated devices such as motor-generator sets, compressors, conveyors, portable tools, lighting systems and similar equipment ɀ in locations which are hazardous due to the presence of flammable vapors or gases ɀ in damp or corrosive locations ɀ at petroleum refineries, chemical and petrochemical plants, and other process industry facilities where similar hazards exist

Fig. 2

Typedriver Name: TS name

CESD – Cl. I, Div. 1 & 2, Group D* CES – Cl. I, Div. 1 & 2, Groups C,D Explosionproof Wet Locations Factory Sealed

Application:

Fig. 1

TCP: 15001

ɀ NEC article 501 and CEC Part 1 Section 18 require that metal frames or exposed noncurrent-carrying metal parts of portable devices used in hazardous locations be grounded through an extra conductor in the portable cord.

ɀ CPH plugs can also be used with standard AR and NR receptacles of the same ampere rating, style and number of poles, thus permitting portable devices which are suitable for use in hazardous locatioins to be connected to receptacles in both hazardous and non-hazardous areas ɀ Portable devices for non-hazardous areas equipped with APJ and NPJ Arktite plugs cannot be used with CES and CESD receptacles

Standard Materials: ɀ Back boxes – Feraloy® iron alloy ɀ Receptacle housings – 30 ampere – copper-free aluminum; 60 ampere – Feraloy® iron alloy ɀ Plug bodies – copper-free aluminum ɀ Insulation – Krydon® fiberglass – reinforced polyester ɀ Contacts – brass or hard-drawn copper

Standard Finishes: ɀ Feraloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Krydon material – red ɀ Brass and copper – natural

Electrical Rating Ranges: ɀ 30 and 60 amperes

Certifications and Compliances: ɀ NEC/CEC: CES – Class I, Division 1 and 2, Groups C,D; CESD – Class I, Division 1 and 2, Group D* ɀ ANSI/UL Standard: 1010 ɀ CSA Standard C22.2 No. 182.1 * For U.S. CESD are also suitable for Class I, Group C when used with immediately adjacent seals.

Options: ɀ The following special options are available from factory by adding suffix to Cat. No.:

Suffix to be Added to Cat. #

Description Special polarity – for use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available as follows: Receptacle interior rotated 221⁄2 degrees clockwise when viewed from face and plug changed to match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4 US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1011)) CH0 2 P - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1011

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1012-1 Name: 2P-1012

DATE: JAN 19 2006

Time: 6:08:38 PM Operator: RB

CES and CESD Arktite Receptacles

2P

Circuit Breaking Delayed Action, CPH Plugs Dimensions

CES Cat. # CES2213 CES2214 CES4233 CES4234

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

CESD – Cl. I, Div. 1 and 2, Group D* CES – Cl. I, Div. 1 and 2, Groups C,D Explosionproof Wet Locations Factory Sealed

CESD a

b

c

d

e

f

g

h

j

77⁄16

45⁄8

23⁄16

33⁄8

23⁄4

41⁄8

5⁄16

11⁄32

7⁄8

Cat. # CESD2213 CESD2214

12

7

27⁄8

51⁄4

43⁄8

61⁄8

7⁄16

13⁄32

11⁄8

CESD4233 CESD4234

a

b

e

f

g

h

j

75⁄8

63⁄8

41⁄4

5

17⁄8

11⁄32

13⁄16

131⁄2

95⁄8

61⁄4

71⁄4

3

13⁄32

13⁄16

CPH Cat. # CPH7713 CPH7913 CPH7714 CPH7914 CPH7733 CPH7933 CPH7734 CPH7934

a 6 67⁄16 6 67⁄16 73⁄4 81⁄8 73⁄4 81⁄8

b 23⁄8 23⁄8 23⁄8 23⁄8 23⁄4 23⁄4 31⁄16 31⁄16

c 45⁄16 43⁄4 45⁄16 43⁄4 5 53⁄8 5 53⁄8

* In U.S. CESD are also suitable for Class I, Group C when used with immediately adjacent seals.

1012

STIBOINFO((CRH:66008com:2P:1012)) CH0 2 P - 1 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1013-5 Name: 2P-1013

DATE: JAN 19 2006

Time: 6:08:38 PM Operator: RB

CES and CESD Arktite® Receptacles Delayed Action Circuit Breaking CPH Plugs

CES Receptacles with three hubs – one on each side and one at top – and two pipe plugs with CPH plug fully engaged

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

CESD – Cl. I, Div. 1 & 2, Group D* CES – Cl. I, Div. 1 & 2, Groups C,D Explosionproof Wet Locations Factory Sealed

csm no.: 100

2P

CESD Receptacles with vertical through feed hubs and one pipe plug. Removable threaded cover at top to facilitate pulling wires

CES/CESD Receptacles Hub Size 3⁄4

Circuit 2-wire, 3-pole

3⁄4

3-wire, 4-pole

11⁄4

2-wire, 3-pole

11⁄4

3-wire, 4-pole

Phase 1 3

{ {

1 3

Max. HP 1⁄2 11⁄2

Max. Amps 7 30

Volts at 60 Cycles AC 4801 120 to 240

1 3

7 30

4801 120 to 240

3

30 60

4801 120 to 240

5

30 60

4801 120 to 240

Max. HP 1⁄2 11⁄2

Max. Amps 7 30

Volts at 60 Cycles AC 4801 120 to 240

1 3

7 30

4801 120 to 240 4801 120 to 240 4801 120 to 240

CES Cat. #

CESD Cat. #

CES2213

CESD2213

CES2214

CESD2214

CES4233

CESD4233

CES4234

CESD4234

CPH Plugs with mechanical cable grip and Neoprene bushing

CPH Plugs Circuit 2-wire, 3-pole 3-wire, 4-pole

Phases 1 3

{ {

2-wire, 3-pole

1

3

30 60

3-wire, 4-pole

3

5

30 60

CABLE DIA. .375 to .875 CPH7713 CPH7714

.500 to .875

CPH7733 CPH7734

.875 to 1.375 CPH7913 CPH7914 CPH7933 CPH7934

* In U.S. CESD are also suitable for Class I, Group C when used with immediately adjacent seals. 1 CSA certified units are rated at 600 volts.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:2P:1013)) CH0 2 P - 1 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1013

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1014-1 Name: Note Page-1014

DATE: JAN 19 2006

Time: 6:08:40 PM Operator: RB

COLOR: CMYK

Notes Page

1014

STIBOINFO((CRH:66008com::1014)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1015-6 Name: 3P-1015

100: DATE: JAN 19 2006

Time: 6:08:40 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

csm no.: 100

3P

Description

Page No.

Application/Selection

1016, 1017

Interlocked Receptacle with – Disconnect Switch WSR 30, 60, 100A Aluminum WSRD 30, 60, 100A Sheet Metal WSRDW 30, 60, 100A Viewing Window WSRD SM S901 Stainless Steel DSR 30, 60, 100A Aluminum Arktite Welder Series Interlocked Power Module

1018, 1019 1018, 1019 1018, 1019 1020-1022 1036 1027

Rotary Switch CSR 30 & 60A Non-metallic NEMA 4X SRG/SP 30, 60 & 100A WSQC 30 & 60A Aluminum

1024-1026 1028, 1029 1037

Circuit Breaker DBR 30, 60 & 100A Aluminum

1030, 1031

®

Watertight Krydon NEMAX 4X NSR 30, 60 & 100A Switch NBR 30, 60 & 100A Breaker

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1015)) CH0 0 0 0 3 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1032, 1033 1034, 1035

1015

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1016-3 Name: 3P-1016

100: DATE: JAN 19 2006

Time: 6:08:41 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Plugs and Receptacles

3P

Industrial Heavy Duty Interlocked Application and Selection

Application: ɀ Where extra protection is a requirement. Interlocked units provide dead front receptacles; connection cannot be made or broken when unit is under load ɀ In areas where dirt, moisture, and corrosion are a problem; to supply power for portable electrical equipment and provide safe disconnect means and short circuit protection

Considerations for Selection: Environmental: ɀ The environment of the enclosure location in terms of NEMA/EEMAC type required ɀ Material and construction to withstand rough usage and corrosive atmospheric conditions Electrical: ɀ Sufficient current carrying capacity to meet load requirements ɀ Compatibility with electrical system (new or existing installations)

ɀ Interchangeability of plugs with hazardous and non-hazardous area receptacles Function: ɀ Switch vs. circuit breaker See ‘‘Quick Selector Chart’’ below and ‘‘Interchangeability Chart’’ on page 1017 for guidance.

Options: Special polarity and conduit arrangements are available to meet specific needs. See individual listing pages for details.

Quick Selector Chart

Series

Receptacle Interlocked With

NEMA/EEMAC Rating

Mating Plug

Electrical Characteristics

CSR

Disconnect switch

3,4X,12

APJ/NPJ

Circuit breaker: 30, 60 amp 600VAC Fusible or non-fusible

Receptacle: 30, 60 amp 600VAC 3-wire, 4-pole

DBR

Circuit breaker

3,9F,G,12 NEC: Cl. II, Division 1 and 2, Groups F,G Cl. III CEC: Cl. II, Division 1 and 2, Group G Cl. III

APJ/NPJ

Circuit breaker: 100 amp. frame size 250VDC/600VAC

Receptacle: 30, 60, 100 amp. 250VDC/600VAC 3-wire, 3-pole 3-wire, 4-pole

DSR

Disconnect switch

3,12

APJ

Switch: 60 and 100 amp 250VDC/600VAC 3-pole Fusible or non-fusible

Receptacle: 60 and 100 amp. 250VDC/600VAC 3-wire, 4-pole

NBR

Circuit breaker

3,12

APJ/NPJ

Circuit breaker: 100 amp. frame size 250VDC/600VAC 3-pole

Receptacle: 30, 60, 100 amp. 250VDC/600VAC 3-wire, 3-pole 3-wire, 4-pole

NSR

Disconnect switch

3,12

APJ/NPJ

Switch: 30, 60, 100 amp. 250VDC/240VAC 600VAC 3-pole Fusible or non-fusible

Receptacle: 30, 60, 100 amp. 250VDC/600VAC 3-wire, 3-pole 3-wire, 4-pole

SRG

Rotary switch

SP

Switch: 30, 60, 100 amp. 480VAC

Receptacle: 30, 60, 100 amp. 480VAC 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

WSR

Disconnect switch

3,4,12

APJ/NPJ

Switch: 30, 60, 100 amp. 250VDC/240VAC 600VAC 3-pole Fusible or non-fusible

Receptacle: 30, 60, 100 amp. 250VDC/600VAC 3-wire, 3-pole 3-wire, 4-pole

WSRD

Disconnect switch

12

APJ/NPJ

Switch: 60 amp. 250VDC/240VAC 600VAC 3-pole Fusible or non-fusible

Receptacle: 60 amp. 250VDC/600VAC 3-wire, 3-pole 3-wire, 4-pole

1016

STIBOINFO((CRH:66008com:3P:1016)) CH0 0 3 P - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1017-1 Name: 3P-1017

DATE: JAN 19 2006

Time: 6:08:41 PM Operator: RB

COLOR: CMYK

TCP: 15001

Plugs and Receptacles

Typedriver Name: TS name

csm no.: 100

3P

Industrial Heavy Duty Interlocked Interchangeability Chart

Interchangeability Chart Many of the plugs listed in this section can be used interchangeably with receptacles from other sections, both in hazardous and nonhazardous areas, provided electrical rating and style of plug and receptacle are the same. The following table is a summary of possible combinations. Plugs Shown in Section 3P

Can be Used with these Receptacle Series

Plug & Receptacle Listed in Electrical Section Rating

AP

AR

1P

APJ/NPJ

AR DR DBR, EBBR FSQ, EPC, EPCB BHR

1P 2P 4P 4P 4P

SP

200 and 400 amp. 3-wire, 4-pole 30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole 30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1017)) CH0 0 3 P - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1017

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1018-1 Name: 3P-1018

100: DATE: JAN 19 2006

Typedriver Name: TS name

30,60,100A NEMA 3,3R,4,4X,12 Raintight Watertight Corrosion-Resistant

WSR

WSRD

WSRDW

Sheet Metal NEMA 3R,12

Sheet Metal Viewing Window NEMA 3R,12

ɀ The WSR and WSRD disconnect switches are used as a service outlet for portable or fixed electrical equipment – generators, compressors, welders, etc. ɀ They are designed for use in nonhazardous areas where dust, moisture and corrosion may be a problem. ɀ Designed for flush or surface mounting. ɀ A fusible type switch, when used, also provides short circuit protection.

Features: WSR and WSRD: ɀ Switches are NEMA type HD heavy duty 3-pole, with visible blades; a quick makeand-break mechanism with reinforced, positive pressure type blade and jaw construction. Fusible types have fuse clips with steel reinforcing springs of positive pressure type. Pressure connectors are used for wire connectors. ɀ For maximum safety, the spring door receptacle at the bottom of the unit is mechanically interlocked with the switch operating mechanism. The switch cannot be closed until the plug is fully inserted and the plug cannot be withdrawn or inserted unless the switch is open. With the switch open, accidental plug withdrawal is prevented by the interlock mechanism. Withdrawal can only be accomplished by activation of the interlock release lever located on the receptacle. ɀ Enclosures are compact and rectangular in shape with a gasketed, hinged door. ɀ Enclosure, handle and other exterior parts are corrosion resistant.

STIBOINFO((CRH:66008com:3P:1018))

TCP: 15001

Aluminum NEMA 3R,12

Application:

CH0 0 3 P - 2

COLOR: CMYK

WSR, WSRD, WSRDW Interlocked Arktite® Receptacles with Enclosed Disconnect Switches

3P

1018

Time: 6:08:42 PM Operator: RB

ɀ The switch enclosure covers are interlocked with the body and operating mechanism and cannot be opened when the plug is engaged and the switch is closed (‘‘ON’’). When the switch is open, the switch cannot be put in a closed (‘‘ON’’) position with the door open. WSR: ɀ Mounting lugs may be rotated 90° or moved to the vertical centerline portion for pole mounting. ɀ Side hinged covers are retained in a closed position by compression spring draw-pull catches, which permit the opening or closing of the cover without tools. ɀ The switch operating handle may be padlocked in the ‘‘ON’’ or ‘‘OFF’’ position, thereby preventing unauthorized operation of the switch and/or opening of the enclosure. Up to three padlocks may be used. In addition, a unique hinge arrangement has been devised to allow the door of the unit to be padlocked. This feature allows operation while preventing unqualified or unauthorized entry.

Standard Materials: WSR and WSRD: ɀ Receptacle housings and plug exteriors – copper-free aluminum ɀ Insulation (plug and receptacle) – fiberglass-reinforced polyester ɀ Pressure contacts – brass ɀ Crimp/solder contacts – leaded red brass WSR: ɀ Enclosure – copper-free aluminum ɀ Operating handle – copper-free aluminum ɀ Other exterior parts – stainless steel WSRD: ɀ Enclosure – sheet steel ɀ Operating handle – sheet steel ɀ Other exterior parts – stainless steel

US: 1-866-764-5454

CAN: 1-800-265-0502

Standard Finishes: ɀ Copper-free aluminum – WSR enclosure, plug exteriors – natural ɀ Leaded red brass – electro-tin-plate ɀ Brass – natural ɀ Sheet steel – baked grey enamel ɀ Fiberglass-reinforced polyester – natural (red)

Electrical Rating Ranges: ɀ 3 and 4 pole; fusible or non-fusible; 240 vac, 250 vdc; 600 vac ɀ 30, 60, 100 amperes ɀ 71⁄2 to 75 HP

Certifications and Compliances: WSR: ɀ NEMA 3R, 4, 12 (enclosure) ɀ UL Standard 98 WSRD: ɀ NEMA 3R, 12 ɀ UL Standard 98

Options: ɀ Interiors rotated 221⁄2° to the right (viewed from face) – add suffix S4 to Cat. No. ɀ Auxiliary switch, 600 vac-dc heavy duty push button station rating, can be supplied, and its contacts will close after safety switch contacts open and close before safety switch opens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S483 ɍɍ Pressure connectors are supplied as standard. To

specify crimp/solder type terminations, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug)

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1019-2 Name: 3P-1019

DATE: JAN 19 2006

Time: 6:08:43 PM Operator: JB COLOR: CMYK

WSR, WSRD, WSRDW Interlocked Arktite® Receptacles with Enclosed Disconnect Switches WSR

System

Amps

Typedriver Name: TS name csm no.: 100

30,60,100A NEMA 3,3R,4,4X,12 Raintight Watertight Corrosion-Resistant

APJ/NPJ Plugs

Conduit Opening Sizes§

TCP: 15001

3P

WSRD‡2 For viewing window see note 2

240VAC 600VAC 250VDC Cat. #

Max. HP Rating 240VAC

Max. HP Rating 480VAC

Max. HP Rating 600VAC

Max.1 HP Rating 480VAC

600VAC 250VDC Cat. #

Max.1 HP Rating 600VAC

3-Wire, 3-Pole Style 1, Fusible

30 60 100

1 11⁄4 11⁄2

WSR3351* WSR6351* WSR10351*

71⁄2 15 30

15 30 60

20 50 75

WSRD3351* WSRD6351* WSRD10351*

15 30 60

20 50 75

3-Wire, 4-Pole Style 2, Fusible

30 60 100

1 11⁄4 11⁄2

WSR3352* WSR6352* WSR10352*

71⁄2 15 30

15 30 60

20 50 75

WSRD3352* WSRD6352*  WSRD10352*

15 30 60

20 50 75

3-Wire, 3-Pole Style 1, NonFusible

30 60 100

1 11⁄4 11⁄2

WSR33541 WSR63541 WSR103541

71⁄2 15 30

15 30 60

20 50 75

WSRD33541 WSRD63541  WSRD103541

15 30 60

20 50 75

3-Wire, 4-Pole Style 2, NonFusible

30 60 100

1 11⁄4 11⁄2

WSR33542 WSR63542 WSR103542

71⁄2 15 30

15 30 60

20 50 75

WSRD33542 WSRD63542  WSRD103542

15 30 60

20 50 75

APJ/NPJ Plugs Outside Dia. of Cable, Flexible Conduit or Style 1† 3-wire, Armored Cable 3-pole Cat. #

Style 2† 3-wire, 4-pole Cat. #

250 DC 600 AC

0.60 to 1.20 0.55 to .070 0.70 to 0.85

APJ3375

APJ3485 NPJ3483 NPJ3484

60

250 DC 600 AC

0.75 to 1.45 0.75 to 1.07 1.07 to 1.35

APJ6375

APJ6485 NPJ6484 NPJ6485

100

250 DC 600 AC

1.00 to 1.70 0.93 to 1.21 1.21 to 1.50

APJ10377

APJ10487 NPJ10486 NPJ10487

Amps 30

Max. Volts

* Arranged for NEC Class H fuses. May be field converted to NEC Class J fuses. § Furnished with reducer which may be removed to obtain one size larger opeing. Locknut and bushing used must meet NEC requirements. (WSR only). † Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a detailed description of these grounding methods, see page 966. ‡ Conduit entrances not furnished. 1 Ratings of unfused and fusible switches with time delay fuses. 2 Viewing window – add ‘‘W’’ to prefix, i.e.: WSRDW6352.

Dimensions WSR

WSR Amps. a b c d e f g gg Mtg. Holes

WSRD

30 113⁄4 201⁄16 69⁄16 71⁄4 215⁄32 2711⁄16 43⁄4 7

60 113⁄4 201⁄16 69⁄16 71⁄4 215⁄32 2811⁄16 51⁄4 613⁄16

100 147⁄8 265⁄16 99⁄16 81⁄4 27⁄8 353⁄8 71⁄4 73⁄4

3⁄8

3⁄8

7⁄16

WSRD 60 Amps. g 513⁄16 gg 613⁄16 Mtg. 5⁄16 Holes Dim. ‘‘g’’ and ‘‘gg’’ are exposed portion of plug when engaged with receptacle.

APJ

NPJ

APJ

 – available with Lightning Service

TM

delivery. See Section G for complete details.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1019)) CH0 0 3 P - 3

NPJ

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1019

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1020-7 Name: 3P-1020

3P

100: DATE: JAN 19 2006

Time: 6:08:45 PM Operator: RB

Arktite® WSRD SMS901 Stainless Steel Interlocked Receptacles

COLOR: CMYK

TCP: 15001

30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed

Typedriver Name: TS name

Watertight Corrosion-Resistant

Fused and Non-Fused WSRD SMS901 SERIES STAINLESS STEEL ARKTITE® INTERLOCKED RECEPTACLES

Cooper Crouse-Hinds Arktite Stainless Steel Interlocks prevent engagement and disengagement of the plug under load, providing safe portable connections and extended product life. Available in 30-100 Amp in both fused and nonfused versions, the Stainless Steel Interlock is rated Enclosure Type 4X watertight and features an optional viewing window. Arktite stainless steel interlocked receptacles: ឣ supply power to portable or fixed electrical equipment such as welders, compressors, conveyors, portable tools, lighting systems and similar equipment. ឣ are used in damp or corrosive locations. ឣ are ideal for use in wet locations & hosedown areas.

ADDITIONAL FEATURES AND BENEFITS

ɀ Heavy duty Arktite receptacle is compatible with existing Cooper Crouse-Hinds Arktite plugs of same rating and configuration. ɀ Self-wiping, naval brass contacts in receptacle assure reliable performance and long dependable life ɀ Stainless steel interior hardware. ɀ Ground bar supplied as standard and connected to 4th wire in receptacle. ɀ UL and cUL Listed

ORDERING INFORMATION (3 Pole, 4 Wire - 600 VAC) Catalog Amps Number

1020

STIBOINFO((CRH:66008com:3P:1020)) CH0 0 4 F - 5

US: 1-866-764-5454

Description

Cooper Crouse-Hinds Weight Mating Arktite Plug lbs. Catalog Numbers

30 30 30

WSRDW3352SMS901 WSRD33542SMS901 WSRDW33542SMS901

Fused w/Window Non-Fused Non-Fused w/Window

24 22 22

APJ3485 & NPJ3485 APJ3485 & NPJ3485 APJ3485 & NPJ3485

60 60 60

WSRDW6352SMS901 WSRD63542SMS901 WSRDW63542SMS901

Fused w/Window Non-Fused Non-Fused w/Window

30 29 29

APJ6485 & NPJ6485 APJ6485 & NPJ6485 APJ6485 & NPJ6485

100 100 100

WSRDW10352SMS901 Fused w/Window WSRD103542SMS901 Non-Fused WSRDW103542SMS901 Non-Fused w/Window

36 35 35

APJ10487 & NPJ10487 APJ10487 & NPJ10487 APJ10487 & NPJ10487

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1021-5 Name: 3P-1021

DATE: JAN 19 2006

Time: 6:08:47 PM Operator: RB

Arktite® WSRD SM S901 Stainless Steel Interlocked Receptacles

COLOR: CMYK

30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed

TCP: 15001

Typedriver Name: TS name

Watertight Corrosion-Resistant

csm no.: 100

3P

Fused and Non-Fused

Optional window allows viewing of both visible blade and indicating type fuses.

Plug locks into receptacle, providing positive, worry-free power engagement as well as watertight protection

CERTIFICATIONS AND COMPLIANCES

ɀ UL Listed - (UL Standards 508, 1682) ɀ cUL Listed (Certified by UL to CSA Standards C22.2 Nos. 14, 182.1) ɀ Enclosure Type 3, 4, 4X, 12 ɀ IP66 Enclosure

STANDARD MATERIALS ɀ Enclosure - Type 304 stainless steel ɀ Hardware - stainless steel ɀ Receptacle Housing - aluminum ɀ Power Contacts - naval brass ɀ Interlock Mechanism - stainless steel

STANDARD FINISHES

ɀ Stainless Steel - natural ɀ Aluminum - Corro-free‡ epoxy powder ɀ Brass - natural

OPTIONS

Suffix to be added to Cat. #

Description

ɀ Factory Installed Auxiliary Contacts . . . . . . . . . . . . . . . . .S483 ɀ Rotated Interior (22 1⁄2 degrees to right) . . . . . . . . . . . . . .S4

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1021)) CH0 0 4 F - 5

Complies with OSHA lockout/ tagout requirements

CAN: 1-800-265-0502

Heavy-duty, epoxy coated cast aluminum receptacle with stainless steel interlocking mechanism for superior durability and corrosion resistance.

Copyright© 2006 Cooper Crouse-Hinds

1021

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1022-3 Name: 3P-1022

3P

DATE: JAN 19 2006

Time: 6:08:49 PM Operator: JB COLOR: CMYK

Arktite® WSRD SM S901 Stainless Steel Interlocked Receptacles

TCP: 15001

30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed

Typedriver Name: TS name csm no.: 100

Watertight Corrosion-Resistant

Fused and Non-Fused HORSEPOWER RATINGS Cooper Crouse-Hinds Catalog Number WSRD33542SMS901 WSRDW33542SMS901 WSRDW3352SMS901

240 VAC (1 PH) 5 5 1.5 (3)

240 VAC (3 PH) 10 10 3 (7.5)

480 VAC (1 PH) 7.5 7.5 3 (7.5)

480 VAC (3 PH) 20 20 5 (15)

600 VAC (1 PH) 10 10 3 (10)

600 VAC (3 PH) 30 30 7.5 (20)

250 VDC 5 5 5

10 10 3 (10)

20 20 7.5 (15)

20 20 5 (20)

50 50 15 (30)

25 25 10 (25)

60 60 15 (50)

10 10 10

WSRD103542SMS901 100 Non-Fused 15 40 30 75 40 WSRDW103542SMS901 100 Non-Fused 15 40 30 75 40 WSRDW10352SMS901 100 Fused 7.5 (15) 15 (30) 10 (30) 25 (60) 15 (40) NOTE: Values for Non-Fused units are maximum horsepower. Values for Fused units are standard horsepower with standard fuse and (maximum horsepower with time delay).

100 100 30 (75)

20 20 20

WSRD63542SMS901 WSRDW63542SMS901 WSRDW6352SMS901

Amps Fusing 30 Non-Fused 30 Non-Fused 30 Fused 60 60 60

Non-Fused Non-Fused Fused

DIMENSIONS (Inches)

1022

STIBOINFO((CRH:66008com:3P:1022)) CH0 0 4 F - 5

US: 1-866-764-5454

Amps

A

B

C

D

E

30 60

5.47 7.99

16.49 18.49

23.49 25.49

9.00 11.52

8.61 8.61

100

8.47

24.18

31.18

12.00

8.61

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1023-4 Name: Note Page-1023

DATE: JAN 19 2006

Time: 6:08:51 PM Operator: JB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Notes Page

US: 1-866-764-5454

STIBOINFO((CRH:66008com::1023)) CH0 3 A - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1023

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1024-10 Name: 3P-1024

3P

DATE: JAN 19 2006

Time: 6:09:50 PM Operator: RB

Arktite® CSR Series Nonmetallic Interlocked Receptacles

COLOR: CMYK

TCP: 15001

30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed

Typedriver Name: TS name csm no.: 100

Watertight Corrosion-Resistant

Fused and Non-Fused CSR SERIES COMPACT INTERLOCKED ARKTITE® RECEPTACLES

Cooper Crouse-Hinds interlocked receptacles prevent engagement and disengagement of the plug under load, providing safe portable connections and extended product life. Arktite compact interlocked receptacles are used: ឣ to supply power to portable or fixed electrical equipment such as welders, compressors, conveyors, portable tools, lighting systems and similar equipment. ឣ in damp or corrosive locations. ឣ in wet locations. ឣ in hosedown areas.

ADDITIONAL FEATURES AND BENEFITS

ɀ Enclosure Type 4X, Watertight, IP66. ɀ Compact enclosure is designed to fit into the web of an I-beam. ɀ Heavy duty Arktite® receptacle is compatible with existing Cooper Crouse-Hinds Arktite® plugs of same rating and configuration. ɀ Bussmann® CubeFuse TM with Indicator – the world’s first ‘‘finger-safe’’ industrial power fuse. ɀ Front mounted handle permits the interlocked receptacles to be easily mounted side by side or in tight spots. ɀ Molded-in-place mounting feet require only four screws to mount the entire unit. ɀ UL and cUL Listed

ORDERING INFORMATION (600 VAC) Amps 30 30 60 60

1024

STIBOINFO((CRH:66008com:3P:1024)) CH0 0 4 F - 5

US: 1-866-764-5454

Configuration

Hub Size

Fusing

Catalog Number

Mating Catalog Number

3W, 4P 3W, 4P 3W, 4P 3W, 4P

1⍯ 1⍯ 11⁄4⍯ 11⁄4⍯

Fused Non-Fused Fused Non-Fused

CSR3352 CSR33542 CSR6352 CSR63542

APJ3485/NPJ3484 APJ3485/NPJ3484 APJ6485/NPJ6484 APJ6485/NPJ6484

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1025-9 Name: 3P-1025

DATE: JAN 19 2006

Time: 6:09:53 PM Operator: JB COLOR: CMYK

Arktite® CSR Series Nonmetallic Interlocked Receptacles

30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed

TCP: 15001

Typedriver Name: TS name csm no.: 100

Watertight Corrosion-Resistant

3P

Fused and Non-Fused

Fully rated for 30A and 60A at 600 VAC. For use with Bussmann CubeFuse. Fuses not included.

Plug locks into receptacle, providing positive, worry-free power engagement as well as watertight protection

CERTIFICATIONS AND COMPLIANCES

ɀ UL Listed – (UL Standards 508, 1682) ɀ cUL Listed (Certified by UL to CSA Standards C22.2 Nos. 14, 182.1) ɀ Enclosure Type 3, 4, 4X, 12 ɀ IP66 Enclosure

STANDARD MATERIALS ɀ Enclosure - fiber reinforced polyester ɀ Hardware - stainless steel ɀ Receptacle Housing - aluminum ɀ Power Contacts - naval brass ɀ Interlock Mechanism - stainless steel

STANDARD FINISHES

ɀ Aluminum - Corro-free TM epoxy powder ɀ Brass - natural ɀ Stainless Steel - natural

Complies with OSHA lockout/ tagout requirements

OPTIONS

Suffix to be Description added to Cat. # ɀ Factory Installed Auxiliary Contacts . . . . . . . . . . . . . . . . S483 ɀ Rotated Interior (22 1⁄2 degrees to right) . . . . . . . . . . . . . S4

HORSEPOWER RATINGS 30 A 60 A

250 VAC 10 HP 20 HP

480 VAC 20 HP 40 HP

600 VAC 25 HP 40 HP

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1025)) CH0 0 4 F - 5

CAN: 1-800-265-0502

Heavy-duty, epoxy coated cast aluminum receptacle with stainless steel interlocking mechanism for superior durability and corrosion resistance.

Copyright© 2006 Cooper Crouse-Hinds

1025

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1026-2 Name: 3P-1026

3P

100: DATE: JAN 19 2006

Time: 6:09:55 PM Operator: RB

Arktite® CSR Series Nonmetallic Interlocked Receptacles

COLOR: CMYK

TCP: 15001

30, 60 and 100 Amp Enclosure Type 3,4,4X,12 IP66 UL and cUL Listed

Fused and Non-Fused

Amps 30 30 60 60

1026

STIBOINFO((CRH:66008com:3P:1026)) CH0 0 4 F - 5

Style

Dimension A

Dimension B

Hub Size

Fused Non-Fused Fused Non-Fused

18.26 18.26 19.26 19.26

8.00 7.87 8.00 7.87

1⍯ 1⍯ 11⁄4⍯ 11⁄4⍯

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name

Watertight Corrosion-Resistant

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1027-5 Name: 3P-1027

DATE: JAN 19 2006

Time: 6:09:59 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

UL/cUL Listed

Arktite Welder Series

csm no.: 100

3P

Interlocked Power Modules

Cooper Crouse-Hinds Interlocked Power Modules are ideal for the harsh, heavy duty environments of welding applications. The Welder Series Power Module is a unique patented design that employs a mechnical interlock linkage system that interfaces with the power receptacle and the built in circuit breaker. It is ideal for protecting the safety of your personnel and your valuable welding equipment.

APPLICATIONS

ɀ Ship building yards ɀ Ports ɀ Offshore platform fabrication yards ɀ Test stations at remote sites ɀ Military heavy equipment manufacturing

FEATURES & BENEFITS

ɀ Mechanically interlocked to prevent insertion or withdrawal of plug under load ɀ Circuit breaker protected ɀ Stainless steel and die cast construction provides durability and corrosion resistance ɀ Flanged design for easy panel mounting and flexibility of Power Stand design ɀ Arktite® receptacle accepts existing Cooper Crouse-Hinds Arktite die cast and Krydon® plugs of the same rating and configuration

CERTIFICATIONS & COMPLIANCES

ɀ UL/cUL Listed Module ɀ UL 498 Listed ɀ CSA Certified Molded Case Circuit Breaker

STANDARD MATERIALS & FINISHES

ORDERING INFORMATION 3 Wire 4 Pole 480 VAC 22K AIC Rating* Amps 30 30 (configured) 30 60 60 (configured) 60 100 100 (configured) 100 200

Receptacle Die cast Die cast Krydon Die cast Die cast Krydon Die cast Die cast Krydon Die cast

Catalog Number M4IPM AR342 3048022K M4IPM ARC34P 3048022K M4IPM NR342 3048022K M4IPM AR642 6048022K M4IPM ARC64P 6048022K M4IPM NR642 6048022K M4IPM AR1042 10048022K M4IPM ARC104P 10048022K M4IPM NR1042 10048022K M4IPM AR2042 20048022K

Dimension A B 2.8 8.00 2.8 8.00 3.1 8.00 4.3 8.00 4.3 8.00 4.5 8.00 5.3 8.00 5.3 8.00 5.6 8.00 7.3 10.0

65K AIC rating available, substitute 65K for 22K in catalog number

DIMENSIONS - 30, 60, 100 A

ɀ Frame, On/Off Rod, Interlock Mechanism, Fasteners - Stainless steel ɀ Receptacle Housing - Die cast aluminum or Krydon ɀ Power Contacts - Naval brass ɀ Receptacle Insulator - Krydon

DIMENSIONS - 200 A

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1027)) CH0 0 4 F - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1027

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1028-1 Name: 3P-1028

3P

100: DATE: JAN 19 2006

Time: 6:10:01 PM Operator: RB

COLOR: CMYK

TCP: 15001

Weather Resistant

SRG Dead Front Interlocked Receptacles and Switches SP Plugs For Panel and Cabinet Mounting

Application: SRG dead front interlocked receptacles and switches and SP plugs are used: ɀ to supply power to portable electrical equipment such as motor-generator sets, compressors, heating and cooling units, conveyors, and similar equipment ɀ in areas where dust, dirt, moisture and corrosion are a problem ɀ mounted on sheet metal panels or cabinets and installed indoors or outdoors in nonhazardous areas of chemical plants, process industry facilities, manufacturing plants, and similar industrial locations

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Phenolic – natural (black) ɀ Brass – silver plated

Options: ɀ Special polarity – where two or more receptacles of the same ampere rating and number of poles are to be installed in the same area for use on different voltages, alternate polarizations can be furnished. Detailed information on request.

Electrical Rating Ranges: ɀ 30, 60 and 100 amperes, 480 vac

Features: ɀ The receptacle assembly contains a built-in rotary switch which is automatically operated when the plug is inserted and withdrawn. The switch, capable of making and breaking the circuit at full rated load, is operated by a helical blade in the center of the plug ɀ Plug and receptacle contacts cannot be made or broken under load. When the plug is inserted, the plug and receptacle contacts engage before the switch closes. When the plug is withdrawn, the switch opens before the plug and receptacle contacts disengage. This sequence of operation provides a dead front receptacle with the maximum of safety ɀ Operation is simple, safe and fast. In the event of difficulty with the portable device, it can be quickly and completely disconnected by a straight pull on the plug, since there are no separate interlock devices or operating handles to actuate ɀ There is a distinct phsyical polarization of plug and receptacle in every rating, thereby assuring positive engagement without mismating ɀ Receptacles are furnished with flexible leads for splicing to the circuit wires ɀ Although intended primarily for mounting on sheet metal panels or cabinets, a back box for conduit connection is listed for the 30 and 60 ampere units

Grounding: ɀ Both receptacles and plugs are provided with an extra grounding pole. In plugs, provision is made for attachment of the grounding wire to the grounding pole. In addition, direct connection is also provided between plug and receptacle housings and the grounding pole.

Dimensions SRG Receptacle

SP Plug

Standard Materials: ɀ Receptacle housings and plug exteriors – copper-free aluminum ɀ Insulation – high impact glass filled phenolic ɀ Contacts – brass

1028

STIBOINFO((CRH:66008com:3P:1028)) CH0 0 3 P - 5

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1029-1 Name: 3P-1029

DATE: JAN 19 2006

Time: 6:10:02 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

30/60/100A 480VAC 50**-400 hertz Weather Resistant

SRG Dead Front Interlocked Receptacles and Switches SP Plugs

csm no.: 100

3P

For Panel and Cabinet Mounting

Rating 30 amp.

60 amp.

100 amp.

Description 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

Receptacle with Spring Door Cat. # SRG332N SRG342D SRG352-NW SRG632N SRG642D SRG652-NW SRG1032N SRG1042D SRG1052-NW

Plug with Cable Grip and Neoprene Bushing Cable Dia. .500 to .875 .875 to 1.375 .500 to .875 .875 to 1.375 .500 to .875 .875 to 1.375 .500 to .875 .875 to 1.375 .500 to .875 .875 to 1.375 .875 to 1.375 1.375 to 1.875 .875 to 1.375 1.375 to 1.875 .875 to 1.375 1.375 to 1.875 .875 to 1.375 1.375 to 1.875

Cat. # SP3363N SP3365N SP3463D SP3465D SP3563-NW SP3565-NW SP6363N SP6365N SP6463D SP6465D SP6565-NW SP6567-NW SP10365N SP10367N SP10465D SP10467D SP10565-NW SP10567-NW

Receptacle with Threaded Cap Cat. # SRG338N SRG348D SRG358-NW SRG638N SRG648D SRG658-NW SRG1038N SRG1048D SRG1058-NW

Plug with Fastening Ring Cable Grip and Neoprene Bushing Cable Dia. Cat. # .500 to .875 SP3383N .875 to 1.375 SP3385N .500 to .875 SP3483D .875 to 1.375 SP3485D .500 to .875 SP3583-NW .875 to 1.375 SP3585-NW .500 to .875 SP6383N .875 to 1.375 SP6385N .500 to .875 SP6483D .875 to 1.375 SP6485D .875 to 1.375 SP6585-NW 1.375 to 1.875 SP6587-NW .875 to 1.375 SP10385N 1.375 to 1.875 SP10387N .875 to 1.375 SP10485D 1.375 to 1.875 SP10487D .875 to 1.375 SP10585-NW 1.375 to 1.875 SP10587-NW

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

Dimensions

Back Box For 30 and 60 amp. SRG receptacles Furnished with vertical through feed hubs, 11⁄4⍯ size, and threaded cover at top for wiring access. Cat. # CESD42

Back box For 30 and 60 Amp SRG Receptacles.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1029)) CH0 0 3 P - 6

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1029

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1030-2 Name: 3P-1030

3P

100: DATE: JAN 19 2006

Time: 6:10:03 PM Operator: RB

DBR Interlocked Arktite® Receptacles With Enclosed Circuit Breakers

COLOR: CMYK

Application:

Standard Materials:

DBR interlocked Arktite receptacles with enclosed circuit breakers and APJ/NPJ Arktite plugs are used: ɀ to supply power to portable electrical equipment such as motor-generator sets, compressors, heating and cooling units, conveyors, and similar equipment ɀ in locations where hazardous dusts are present, as in grain processing and handling plants, chemical plants and certain food processing industries ɀ indoors or outdoors in damp, wet or corrosive locations

ɀ Bodies, covers and operating handles – copper-free aluminum ɀ Operating shafts – stainless steel ɀ Receptacle housings and plug exteriors – copper-free aluminum ɀ Insulation: plugs and receptacles – fiberglass-reinforced polyester ɀ Pressure contacts – brass ɀ Crimp/solder contacts – leaded red brass

ɀ Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection. ɀ Enclosures are compact and rectangular in shape permitting close spacing. ɀ For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the circuit breaker operating mechanism. The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open. ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the ‘‘ON’’ position. ɀ Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a threaded-in bushing. The size furnished is 11⁄2⍯, and removing the bushing permits the use of a 2⍯ conduit.

Interchangeability of Plugs with Other Hazardous and Non-Hazardous Location Receptacles: ɀ Plugs listed for use with DBR assemblies are standard Arktite APJ/NPJ plugs. Other standard APJ/NPJ and CPH plugs of the same rating, style and number of poles may be used with DBR receptacles, as well as with DR receptacles listed in Section 2P and with EBBR, EPC and EPCB receptacles listed in Section 4P. ɀ As a result, portable equipment suitable for the locations and equipped with the proper plug can be used with AR receptacles for non-hazardous locations, with EBBR, EPC and EPCB receptacles for Class I hazardous locations, and with DR and DBR interlocked receptacles for Class II hazardous locations.

Standard Finishes: ɀ Copper-free aluminum – plug exterior, enclosure and receptacle housing – natural ɀ Stainless steel – natural ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate

Options: The following special options are available by adding suffix to Cat. No. Suffix to be Added to Description Cat. # Special polarity – for use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available as follows: ɀ Receptacle interior rotated 221⁄2 degrees clockwise when viewed from receptacle face and plug changed to match . . . . . . . . . . . . . . . . . . . . . S4 Breather (drain furnished as standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . S219 Conduit arrangements other than standard can be supplied . Details on request

Dimensions

Certifications and Compliances: ɀ NEC: Class II, Division 1 and 2, Groups F,G Class III ɀ NEMA/EFC: 3,9FG,12 ɀ UL Standard: 698, 1010 ɀ CEC: Class II, Division 1 and 2, Group G Class III ɀ Encl.: 3,5

Electrical Rating Ranges: ɀ Receptacle ratings: 30, 60 and 100 amperes ɀ Circuit breakers – 100 ampere frame size Amps a b bb 413⁄16 7 30 213⁄4 513⁄16 613⁄16 60 223⁄4 100 231⁄2 65⁄8 73⁄4 Dim. ‘‘b’’ and ‘‘bb’’ are exposed portion of plug when engaged with receptacle.

APJ

ɍɍ Pressure connectors are standard. Crimp/solder type terminators are optionally available for 3 and 4-pole, 30, 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: AP3375-T (Plug)

1030

STIBOINFO((CRH:66008com:3P:1030)) CH0 0 3 P - 7

Typedriver Name: TS name

Cl. II, Div 1 and 2, Groups F,G Cl. III NEMA/EFC 3,9FG,12 Dust-Ignitionproof Raintight

APJ/NPJ Arktite Plugsɍɍ

Features:

TCP: 15001

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

NPJ

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1031-1 Name: 3P-1031

100: DATE: JAN 19 2006

Time: 6:10:05 PM Operator: RB

DBR Interlocked Arktite® Receptacles With Enclosed Circuit Breakers

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. II, Div 1 and 2, Groups F,G Cl. III NEMA/EFC 3,9FG,12 Dust-Ignitionproof Raintight

csm no.: 100

3P

100 Ampere Frame Size with Non-Interchangeable Thermal Trip and Non-Adjustable Magnetic Trip Enclosure Ckt. Hub Bkr. Size Amps

Receptacle With Spring Door Housing†

Circuit Breaker Rating

30 amp., 3-wire, 3-pole, Style 1 30 amp., 2-wire, 3-pole, Style 2 30 amp., 3-wire, 4-pole, Style 2 60 amp., 3-wire, 3-pole, Style 1

3-pole 600VAC

11⁄2

2-pole 600VAC or 250VDC 3-pole 600VAC

11⁄2

3-pole 600VAC

11⁄2

60 amp., 2-wire, 3-pole, Style 2

2-pole 600VAC or 250VDC

11⁄2

60 amp., 3-wire, 4-pole, Style 2

3-pole 600VAC

11⁄2

100 amp., 3-wire, 3-pole, Style 1 100 amp., 2-wire, 3-pole, Style 2 100 amp., 3-wire, 4-pole, Style 2

3-pole 600VAC

11⁄2

2-pole 600VAC or 250VDC 3-pole 600VAC

11⁄2

11⁄2

11⁄2

20 30 40 50 20 30 40 50 20 30 40 50 50 60 70 90 100 50 60 70 90 100 50 60 70 90 100 60 70 90 100 60 70 90 100 60 70 90 100

Without Circuit Breaker Cat. # DBR53731

DBR53732

DBR53742

DBR56731

DBR56732

DBR56742

DBR51731

DBR51732

DBR51742

With Circuit Breaker Cat. # Westinghouse ‘‘FDB’’ DBR53731-WT20-3 DBR53731-WT30-3 DBR53731-WT40-3* DBR53731-WT50-3* DBR53732-WT20-2 DBR53732-WT30-2 DBR53732-WT40-2* DBR53732-WT50-2* DBR53742-WT20-3 DBR53742-WT30-3 DBR53742-WT40-3* DBR53742-WT50-3* DBR56731-WT50-3 DBR56731-WT60-3 DBR56731-WT70-3* DBR56731-WT90-3* DBR56731-WT100-3* DBR56732-WT50-2 DBR56732-WT60-2 DBR56732-WT70-2* DBR56732-WT90-2* DBR56732-WT100-2* DBR56742-WT50-3 DBR56742-WT60-3 DBR56742-WT70-3* DBR56742-WT90-3* DBR56742-WT100-3* DBR51731-WT60-3 DBR51731-WT70-3 DBR51731-WT90-3 DBR51731-WT100-3 DBR51732-WT60-2 DBR51732-WT70-2 DBR51732-WT90-2 DBR51732-WT100-2 DBR51742-WT60-3 DBR51742-WT70-3 DBR51742-WT90-3 DBR51742-WT100-3

* Circuit breaker trip rating may exceed receptacled rating for welding equipment applications only, as higher trip rating may not protect wiring. ɍɍ Pressure connectors are standard. Crimp/solder type terminators are optionally available for 3 and 4-pole 30, 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug) † Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a detailed description of these grounding methods, see page 967. ‡ For circuit breaker Cat. No. refer to Section 6C, Table 9, List FDB. For detailed information on circuit breaker selection, see Section 6C.

APJ/NPJ Arktite Plugsɍɍ 600VAC/250VDC with Cable Grip and Neoprene Bushing Amps 30

60

APJ Plug

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1031)) CH0 0 3 P - 8

100

NPJ Plug

CAN: 1-800-265-0502

Cable O.D. Range 0.60 to 1.20 0.55 to 0.70 0.70 to 0.85 0.75 to 1.45 0.75 to 1.07 1.07 to 1.35 1.00 to 1.70 0.93 to 1.21 1.21 to 1.50

Style 1†

Style 2†

3-wire, 3-pole Cat. # APJ3375

2-wire, 3-pole Cat. # APJ3385 NPJ3383 NPJ3384 APJ6385 NPJ6384 NPJ6385 APJ10387 NPJ10386 NPJ10387

APJ6375

APJ10377

Copyright© 2006 Cooper Crouse-Hinds

3-wire, 4-pole Cat. # APJ3485 NPJ3483 NPJ3484 APJ6485 NPJ6484 NPJ6485 APJ10487 NPJ10486 NPJ10487

1031

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1032-1 Name: 3P-1032

3P

100: DATE: JAN 19 2006

Time: 6:10:05 PM Operator: RB

NSR Arktite® Interlocked Receptacles With Enclosed Disconnect Switches

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

NEMA 3,3R,4*,4X*,12 Watertight Corrosion-Resistant

APJ/NPJ Arktite Plugs Application: NSR Arktite interlocked receptacles with enclosed disconnect switches are used: ɀ to provide a power disconnect for fixed or portable electrical equipment such as welders, generators and compressors where the switch will be subject to frequent operation ɀ to provide short circuit protection when a fusible switch is needed ɀ in non-hazardous indoor or outdoor areas where corrosion, dust, hosedown and moisture may be a problem such as in offshore and marine locations, pulp and paper mills, chemical plants, sewage treatment plants and food processing facilities

Features: ɀ Enclosures are made of Krydon® highimpact strength fiberglass-reinforced polyester material having excellent resistance to corrosion and heat ɀ Switches are NEMA type HD heavy duty 3-pole, enclosed blade; a quick make-andbreak mechanism with reinforced, positive pressure type blade and jaw construction. Fusible switches have fuse clips with steel reinforcing springs ɀ For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the switch operating mechanism. The switch cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the switch is open ɀ Switch enclosure access door is mechanically interlocked with switch and cannot be opened unless switch operator is in ‘‘OFF’’ position ɀ Enclosure has hinged access door for easy wiring and maintenance. Three screws, located behind access door in door frame, prevent disassembly when door is locked ɀ A Krydon material hub (not mounted) is supplied with each enclosure as follows: Rating Hub Size Cat. No. 3⁄4 NHUB2 30A NHUB4 60A 11⁄4 100A 2 NHUB6 For alternate hub sizes, refer to catalog page 658. ɀ Receptacle has self-closing spring door assembly to provide environmental protection ɀ Mounting feet may be rotated 90° to horizontal or vertical mounting positions ɀ Switch operating handle may be padlocked in the ‘‘OFF’’ position, preventing unauthorized operation of the switch

Interchangeability of Plugs With Other Non-Hazardous and Hazardous Location Receptacles:

standard APJ/NPJ and CPH plugs of the same rating, style and number of poles may be used with NSR receptacles, as well as with DR receptacles listed in Section 2P, and with EBBR, EPC and EPCB receptacles listed in Section 4P ɀ Portable equipment, suitable for the locations and equipped with the proper plug, can be used with non-hazardous rated AR receptacles, DBR and WSR interlocked receptacles located in non-hazardous locations, with EBBR, EPC and EPCB receptacles for Class I, Groups B, C, D hazardous locations, with DR and DBR interlocked receptacles for Class II, Groups F, G hazardous locations, and with NBR/NSR interlocked receptacles for wet and corrosive locations

Standard Materials: ɀ Receptacle housings – copper-free aluminum ɀ Insulators (plug and receptacle) – Krydon material ɀ Crimp/solder contacts – leaded red brass ɀ Enclosure and operating handle – Krydon fiberglass-reinforced polyester material ɀ Other exterior parts – stainless steel

Standard Finishes: ɀ Copper-free aluminum – baked-on powder epoxy ɀ Stainless steel – natural ɀ Leaded red brass – electro-tin-plated ɀ Enclosure – natural (gray) ɀ Insulator (plug and receptacle) – natural (red)

Options: ɀ Special polarity – for use where two or more receptacles for the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Receptacle interior rotated 221⁄2 degrees to right (viewed from face) and matching plug – add suffix S4 to Cat. No. ɀ Hubs for other conduit sizes can be supplied. See listing on page 655.

Certifications and Compliances: ɀ NEMA 3, 3R, 4*, 4X*, 12 ɀ ANSI/UL standard 489 ɀ UL standard 1682 ɀ CSA

ɀ Plugs listed for use with NSR assemblies are standard Arktite APJ/NPJ plugs. Other *30 & 60A style 2 only

1032

STIBOINFO((CRH:66008com:3P:1032)) CH0 0 3 P - 9

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1033-1 Name: 3P-1033

DATE: JAN 19 2006

Time: 6:10:07 PM Operator: RB

NSR Arktite® Interlocked Receptacles with Enclosed Disconnect Switches

Amps

TCP: 15001

Typedriver Name: TS name

240 and 600 VAC 250 VDC NEMA 3,3R,4,4X,12 Watertight Corrosion-Resistant

APJ/NPJ Arktite Plugsɍɍ

Conduit Opening Sizes§

COLOR: CMYK

240VAC/250VDC Style 1† Style 2† 3-wire, 3-wire, 3-pole 4-pole Cat. # Cat. #

AC HP Rating

NSR331** NSR631** NSR1031**

NSR332** NSR632** NSR1032**

NSR3341 NSR6341 NSR10341

NSR3342 NSR6342 NSR10342

csm no.: 100

3P

DC HP Rating

600VAC/250VDC Style 1† Style 2† 3-wire, 3-wire, 3-pole 4-pole Cat. # Cat. #

AC HP Rating

DC HP Rating

3 5 10

5 10 20

NSR3351* NSR6351* NSR10351*

NSR3352* NSR6352* NSR10352*

71⁄2 20 30

5 10 20

71⁄2 20 30

5 10 20

NSR33541 NSR63541 NSR103541

NSR33542 NSR63542 NSR103542

20 50 75

5 10 20

FUSIBLE 30 60 100

3⁄4 11⁄4 2

NON-FUSIBLE 30 60 100

3⁄4 11⁄4 2

APJ/NPJ PLUGS 600VAC/250VDC, with Cable Grip and Neoprene Bushing

Amps 30

60

100

Cable O.D. Range

Style 1† 3-wire, 3-pole Cat. #

Style 2† 3-wire, 4-pole Cat. #

0.60 to 1.20 0.55 to 0.70 0.70 to 0.85 0.75 to 1.45 0.75 to 1.07 1.07 to 1.35 1.00 to 1.70 0.93 to 1.21 1.21 to 1.50

APJ3375

APJ3485 NPJ3483 NPJ3484 APJ6485 NPJ6484 NPJ6485 APJ10487 NPJ10486 NPJ10487

APJ6375

APJ10377

* Arranged for NEC Class H fuses. May be field converted to NEC Class J fuses. ** Fuse clips accommodate NEC Class H fuses. For NEC Class J fuses, use 600V switches. ɍɍ Pressure connectors are supplied as standard. To specify crimp/solder type terminators add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug) † Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a detailed description of these grounding methods, see page 967. § For alternate hub sizes, refer to catalog page 658.

Dimensions Amps b a aa 413⁄16 7 30 313⁄8 613⁄16 60 33 513⁄16 100 333⁄4 65⁄8 73⁄4 Dim. ‘‘a’’ and ‘‘aa’’ are exposed portion of plug when engaged with receptacle.

APJ

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1033)) CH0 3 P - 1 0

CAN: 1-800-265-0502

NPJ

Copyright© 2006 Cooper Crouse-Hinds

1033

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1034-3 Name: 3P-1034

3P

100: DATE: JAN 19 2006

Time: 6:10:08 PM Operator: JB COLOR: CMYK

NBR Arktite® Interlocked Receptacles with Enclosed Circuit Breakers

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 3,3R,4*,4X*,12 Watertight Corrosion-Resistant

APJ/NPJ Arktite Plugs Application: NBR Arktite interlocked receptacles with enclosed circuit breakers are used: ɀ to supply power and provide short circuit protection, thermal overload protection, and a disconnect means for portable electrical equipment such as motor generator sets, compressors, conveyors, and other similar equipment ɀ in locations where corrosion is present such as in offshore and marine locations, pulp and paper mills, chemical plants, food processing, and sewage treatment plants ɀ indoors and outdoors in damp, wet or hosedown locations

Features: ɀ Enclosures are made of Krydon® highimpact strength fiberglass-reinforced polyester material having excellent resistance to corrosion and heat ɀ Receptacles are mechanically interlocked with circuit breakers which provide a disconnect means, short circuit protection, and thermal time delay overload protection ɀ For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the circuit breaker operating mechanism. The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open ɀ Enclosure has hinged access door for easy wiring and maintenance. Three screws, hidden behind access door in door frame, prevent disassembly when door is locked ɀ Enclosure access door is mechanically interlocked with operating handle and cannot be opened unless operating handle operator is in ‘‘OFF’’ position ɀ A Krydon material hub (not mounted) is supplied with each enclosure as follows: Rating Hub Size Cat. # 3⁄4 NHUB2 30A NHUB4 60A 11⁄4 100A 2 NHUB6 For alternate hub sizes, refer to catalog page 658. ɀ Receptacle has self-closing spring door assembly to provide environmental protection ɀ Operating handle can be padlocked in ‘‘OFF’’ position. Breaker is trip-free of handle and will open under short circuit or overload when handle is in the ‘‘ON’’ position ɀ Provided with top and bottom mounting feet which may be rotated 90° to vertical or horizontal mounting positions *30 & 60A style 2 only

1034

STIBOINFO((CRH:66008com:3P:1034)) CH0 3 P - 1 1

Interchangeability of Plugs With Other Non-Hazardous And Hazardous Location Receptacles: ɀ Plugs listed for use with NBR assemblies are standard Arktite APJ/NPJ plugs. Other standard APJ/NPJ and CPH plugs of the same rating, style and number of poles may be used with NBR receptacles, as well as with DR receptacles listed in Section 2P, and with EBBR, EPC and EPCB receptacles listed in Section 4P ɀ Portable equipment, suitable for the locations and equipped with the proper plug, can be used with non-hazardous rated AR receptacles, DBR and WSR interlocked receptacles located in non-hazardous locations, with EBBR, EPC and EPCB receptacles for Class I, Groups B, C, D hazardous locations, with DR and DBR interlocked receptacles for Class II, Groups F, G hazardous locations, and with NBR/NSR interlocked receptacles for wet and corrosive locations

Standard Materials: ɀ Enclosure, covers and operating handles – Krydon fiberglass reinforced polyester material ɀ Operating shafts – stainless steel ɀ Receptacle housings – copper-free aluminum ɀ Receptacle insulators – Krydon material ɀ Crimp/solder contacts – leaded red brass

Standard Finishes: ɀ Copper-free aluminum – baked on powder epoxy ɀ Stainless steel – natural ɀ Enclosure – natural ɀ Receptacle insulators – natural (red) ɀ Brass – natural ɀ Leaded red brass – electro-tin-plated

Options: ɀ Special polarity – for use where two or more receptacles of the same ampere rating, style and number of poles are to be installed on the same premises for use of different voltages. Receptacle interior rotated 221⁄2 degrees to right (viewed from face) and plug changed to match – add suffix S4 to Cat. No. ɀ Hubs for other conduit sizes can be supplied. See listing on page 658.

Certifications and Compliances: ɀ NEMA 3, 3R, 4*, 4X*, 12 ɀ ANSI/UL Standard 489 ɀ UL Standard 1682 ɀ CSA

Electrical Rating Ranges: ɀ Receptacles – 30, 60 and 100 amperes ɀ Circuit Breakers – 100 ampere frame size NOTE: For additional dimensional data, see page 655, enclosure catalog number NCB1024.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1035-1 Name: 3P-1035

DATE: JAN 19 2006

Time: 6:10:09 PM Operator: RB

NBR Arktite® Interlocked Receptacles with Enclosed Circuit Breakers APJ/NPJ Arktite Plugsɍɍ

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

3-Pole, 600 VAC

csm no.: 100

3P

NEMA 3,3R,4,4X,12 Watertight Corrosion-Resistant

100 Ampere Frame Size with Non-Interchangeable TripठReceptacle With Spring Door Housing

Enclosure Ckt. Hub Brkr. Size Amps

APJ/NPJ Plugs Without Circuit Breaker Cat. #

With Cutler-Hammer Circuit Breaker Cat. #

NBR53731

NBR53731-WT20-3 NBR53731-WT30-3 NBR53731-WT40-3* NBR53731-WT50-3*

600 VAC With Cable Grip and Neoprene Bushing

STYLE 1† 3⁄4

20 30 40 50

60 amp., 3-wire, 3-pole

11⁄4

50 60 70 90 100

NBR56731

NBR56731-WT50-3 NBR56731-WT60-3 NBR56731-WT70-3* NBR56731-WT90-3* NBR56731-WT100-3*

100 amp., 3-wire, 3-pole

2

60 70 90 100

NBR51731

NBR51731-WT60-3 NBR51731-WT70-3 NBR51731-WT90-3 NBR51731-WT100-3

30 amp., 3-wire, 3-pole

STYLE 2 † 30 amp., 3-wire, 4-pole 60-amp., 3-wire, 4-pole 100 amp., 3-wire, 4-pole

APJ

NPJ 3⁄4

11⁄4

2

20 30 40 50 50 60 70 90 100 60 70 90 100

NBR53742

NBR56742

NBR51742

NBR53742-WT20-3 NBR53742-WT30-3 NBR53742-WT40-3* NBR53742-WT50-3* NBR56742-WT50-3 NBR56742-WT60-3 NBR56742-WT70-3* NBR56742-WT90-3* NBR56742-WT100-3* NBR51742-WT60-3 NBR51742-WT70-3 NBR51742-WT90-3 NBR51742-WT100-3

Amps 30

60

100

Cable O.D. Range 0.60 to 1.20 0.55 to 0.70 0.70 to 0.85 0.75 to 1.45 0.75 to 1.07 1.07 to 1.35 1.00 to 1.70 0.93 to 1.21 1.21 to 1.50

Style 1† 3-wire, 3-pole Cat. # APJ3375

APJ6375

APJ10377

Style 2† 3-wire, 4-pole Cat. # APJ3485 NPJ3483 NPJ3484 APJ6485 NPJ6484 NPJ6485 APJ10487 NPJ10486 NPJ10487

Dimensions Amps b a aa 413⁄16 7 30 313⁄8 613⁄16 60 33 513⁄16 100 333⁄4 65⁄8 73⁄4 Dim. ‘‘a’’ and ‘‘aa’’ are exposed portion of plug when engaged with receptacle.

* Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only, as higher trip rating may not protect wiring. ɍɍ Pressure connectors are standard. Crimp solder type terminators are optionally available for 3 and 4-pole 30, 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug). § Also available with interchangeable trip breakers. Specify on order. † Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a detailed description of these grounding methods, see page 967. APJ

US: 1-866-764-5454

STIBOINFO((CRH:66008com:3P:1035)) CH0 3 P - 1 2

CAN: 1-800-265-0502

NPJ

‡ For circuit breaker Cat. No. refer to Section 6C. Table 9, List FDB. For detailed information on circuit breaker selection, see Section 6C.

Copyright© 2006 Cooper Crouse-Hinds

1035

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1036-2 Name: 3P-1036

3P

100: DATE: JAN 19 2006

Time: 6:10:10 PM Operator: RB

DSR Interlocked Arktite® Receptacles with Enclosed Disconnect Switches

Application:

COLOR: CMYK

TCP: 15001

Cl. II, Div 1 and 2, Group G Cl. III CSA Encl. 3,5 NEMA 3,12

Typedriver Name: TS name

Raintight Dust-Ignitionproof

Dimensions

ɀ The DSR disconnect switches are used as a service outlet for portable or fixed electrical equipment – generators, compressors, welders, etc. ɀ They are designed for use in hazardous and non-hazardous areas where dust, moisture and corrosion may be a problem. ɀ Designed for surface mounting. ɀ A fusible type switch, when used, also provides short circuit protection.

Features: ɀ Switches ɀ Type DS disconnect is a compact load break switch using the De-ion arc quenching principle and quick make-quick break over center toggle mechanism. It has visible contacts, is CSA listed up to 75 hp., and is available either as a fusible or non-fusible switch. ɀ Enclosures are compact and rectangular in shape permitting close spacing with a gasketing cover. ɀ For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the switch operating mechanism. The switch cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the switch is open. ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. ɀ Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a thread-in bushing. The size furnished is 11⁄2⍯, and removing the bushing permits the use of a 2⍯ conduit.

Standard Materials: ɀ Bodies, covers and operating handles – copper-free aluminum. ɀ Operating shafts – stainless steel. ɀ Receptacle housings and plug exteriors – copper-free aluminum. ɀ Insulation: plugs and receptacles – fiberglass-reinforced polyester. ɀ Contacts – brass.

60 Amps – 223⁄4 100 Amps – 231⁄2

a:

Standard Finishes: ɀ Copper-free aluminum – natural. ɀ Stainless steel – natural. ɀ Brass – Bright Dip. ɀ Fiberglass-reinforced polyester – natural (red).

Electrical Rating Ranges: ɀ 3-Wire, 4-Pole: Fusible or non-fusible: 240 VAC 250 vdc: 600 vac 60, 100 amperes ɀ 15 to 75 HP

Certifications and Compliances: ɀ NEC/CEC: Class II, Division 1 and 2, Group G Class III ɀ CSA Encl. 3,5 ɀ NEMA: 3,12

Options: The following special options are available by adding suffix to Cat. No. Description Special polarity for use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available as follows: ɀ Receptacle interior rotated 221⁄2 degrees to right (viewed from face) and plug changed to match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4 ɀ Breather (drain furnished as standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . S219 ɀ Conduit arrangements other than standard can be supplied . . . . . . . . . Details on request.

Ordering Information: Interlocks

System 3-Wire, 4-Pole Style 2, Fusible 3-Wire, 4-Pole Style 2, Non-Fusible

Amps 60 100 60 100

Conduit Opening Sizes 11⁄2 11⁄2 11⁄2 11⁄2

Max. HP Rating 240VAC 15 30 15 30

Max. HP Rating 600VAC 50 75 50 75

DSR 240VAC 250VDC Cat. # DSR632** DSR6342 DSR10342

600VAC 250VDC Cat. # DSR6352* DSR10352* DSR63542 DSR103542

Mating Arktite® Plugs Dia. Style 2 Outside of Cable 3-wire Flexible Conduit or 4-pole Armored Cable Cat. # .75 to 1.45 APJ6485 1.00 to 1.70 APJ10487 .75 to 1.45 APJ6485 1.00 to 1.70 APJ10487

* Arranged for Class J fuses. ** Arranged for Class H fuses.

1036

STIBOINFO((CRH:66008com:3P:1036)) CH0 3 P - 1 3

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1037-1 Name: 3P-1037

DATE: JAN 19 2006

Time: 6:10:11 PM Operator: RB

WSQC Interlocked Arktite® Receptacles with Enclosed Switches

COLOR: CMYK

TCP: 15001

30 & 60A 600 VAC NEMA 3R,12

Typedriver Name: TS name

Raintight Dust Tight

csm no.: 100

3P

APJ Plugs Application: WSQC dead front interlocked receptacles with APJ, NPJ, BP or FP plugs are used: ɀ to supply power to portable electrical equipment such as hand lamps, lighting systems, power tools, conveyors, welders, compressors, etc. ɀ in damp, wet or corrosive locations ɀ indoors or outdoors in non-hazardous areas ɀ in locations where mounting area is confined and compact equipment is required

Features: ɀ NEMA 3R, 12 ɀ Rainproof, dust tight ɀ Available in 30 & 60 amps ɀ Horsepower rated switch ɀ Smallest footprint for interlocked receptacles ɀ Padlockable in OFF position; meets OSHA lockout/tagout requirements ɀ Compatible with Arktite TM APJ aluminum and NPJ Krydon TM material non-metallic plugs

Dimensions (In Inches)

Standard Materials: ɀ Enclosure – copper-free aluminum ɀ Cover & spring door – copper-free aluminum ɀ Insulator – Krydon TM material ɀ Contacts – brass ɀ Cover Gasket – Neoprene

Certifications & Compliances: ɀ NEMA 3R, 12 ɀ CSA Standard C22.2 No. 14, 182.1 ɀ UL and cUL Listed

Amps

A

B

C

D

E

30A 60A

31⁄8 5

93⁄4 147⁄16

— 81⁄2

53⁄4 7

13⁄32

3⁄8

Horsepower Ratings Amps

120V

30A 60A

2

Single Phase 240V 480V 5 10

71⁄2 25

Ordering Information Amps

30A

60A

STIBOINFO((CRH:66008com:3P:1037))

120V

71⁄2 30

3

Three Phase 240V 480V 71⁄2 10

15 25

600V 15 30

OPTIONS:

Hub

Config.

Catalog No.

3⁄4⍯

2W3P 2W3P 3W4P 3W4P 2W3P 3W4P

WSQC2330 WSQC3330 WSQC2340 WSQC3340 WSQC5630 WSQC5640

1⍯ 3⁄4⍯ 1⍯ 11⁄2⍯ 11⁄2⍯

US: 1-866-764-5454

CH0 3 P - 1 4

600V

CAN: 1-800-265-0502

ɀ Interior rotated 221⁄2° to the right (viewed from face) – add suffix to Cat. # – S4, ex: WSQC5640 S4

Copyright© 2006 Cooper Crouse-Hinds

1037

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1038-2 Name: Note Page-1038

DATE: JAN 19 2006

Time: 6:10:12 PM Operator: RB

COLOR: CMYK

Notes Page

1038

STIBOINFO((CRH:66008com::1038)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1039-4 Name: 4P-1039

100: DATE: JAN 19 2006

Time: 6:10:13 PM Operator: RB

COLOR: CMYK

TCP: 15001

Plugs and Receptacles Industrial Heavy Duty Interlocked Hazardous

Typedriver Name: TS name

csm no.: 100

4P

Description

Page No.

Application/Selection

1040, 1041

Interlocked Receptacle with – H.P. Rated Switch Technical Data FSQC 30A & 60A / APJ Plugs FSQC 100A / APJ Plugs FSQ 30A 230 Series / BP Plugs FSQ 30A 232 Series / FP Plugs DSR 60A & 100A W2SR 30A, 60A & 100A

1042 1043 1044 1045 1046 1047 1048

Factory Sealed Switch BHR 30A, 60A & 100A / BHP Plugs SRD 30A & 60A / SP Plugs

1049, 1050 1051, 1052

Circuit Breaker EBBR 30A, 60A, 100A EPC, 30A, 60A, 100A, 200A EPCB 30A, 60A, 100A DBR 30A, 60A, 100A

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1039)) CH0 0 0 0 4 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1053-1055 1056-1058 1059, 1060 1061, 1062

1039

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1040-4 Name: 4P-1040

100: DATE: JAN 19 2006

Time: 6:10:14 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Plugs and Receptacles

4P

Industrial Heavy Duty Interlocked Application and Selection Hazardous Application ɀ Where extra protection is a requirement. Interlocked units provide dead front receptacles; connection cannot be made or broken when unit is under load. ɀ In areas made hazardous by flammable vapors, gases or dusts; to supply power for portable electrical equipment and provide safe disconnect means and short circuit protection.

Considerations for Selection: Environmental: ɀ The environment of the enclosure location in terms of NEC/CEC compliance and NEMA/ EEMAC type required. ɀ Material and construction to withstand rough usage and atmospheric conditions. Electrical: ɀ Sufficient current carrying capacity to meet load requirements. ɀ Compatibility with electrical system (new or existing installation).

ɀ Interchangeability of plugs with other hazardous and non-hazardous area receptacles. Function: ɀ Switch vs. circuit breaker

Options: Special polarity arrangements, material options, accessories, and optional arrangements of enclosure interiors are available to meet specific application needs. See listing pages for details.

Quick Selector Chart NEC/CEC & NEMA/EEMAC Compliances

Receptacles Interlocked With

Class I, Division 1 and 2, Groups B,C,D Class II, Division 1 and 2, Groups F,G Class III NEMA: 3,4,7BCD,9FG,12

Factory Sealed Switch

DBR

NEC: Class II, Division 1 and 2, Groups F,G NEC: Class III NEMA/EFC: 3,9FG,12 CEC: Class II, Division 1 and 2, Group G CEC: Class III Encl. 3,5

DSR

EBBR

Series BHR

EPC

EPC

EPCB

Mating Plugs

Electrical Rating

1049 1050

BHP

30, 60, 100 amp. 480VAC 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

Circuit breaker

1061 1062

APJ/NPJ

Circuit breaker: 100 amp. frame size 250VDC/600VAC Receptacle: 30, 60, 100 amp. 2-wire, 3-pole 3-wire, 3-pole 3-wire, 4-pole

Class II, Division 1 and 2, Group G Class III, Encl. 3,5 NEMA: 3,9G,12

Switch

1047

APJ/NPJ

Class I, Division 1 and 2, Groups B,C,D Class II, Division 1 and 2, Groups F,G Class III NEMA 3,3R,7BCD,9FG,12 NEC: Class I, Division 1 and 2, Groups C,D NEC: Class II, Division 1 and 2, Groups F,G NEC: Class III NEMA: 3,7CD,9FG,12 CEC: Class I, Division 1 and 2, Groups C,D CEC: Class II, Division 1 and 2, Group G CEC: Class III Encl. 3,4 Class I, Division 1 and 2, Group D Class II, Division 1 and 2, Groups F,G Class III NEMA: 3,7D,9FG,12

Circuit breaker

1053 1054 1055

APJ/NPJ

Switch: 60 and 100 amp. 600VAC/250VDC Fusible or non-fusible Receptacle: 60 and 100 amp. 3-wire, 4-pole Receptacle: 30, 60, 100 amp. 3-wire, 4-pole

Circuit breaker

1056 1057 1058

APJ/NPJ

Circuit breaker: 100 amp. frame size 480VAC/250VDC Receptacle: 30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole

Circuit breaker

1057 1058

DP

NEC: Class I, Division 1 and 2, Groups B,C,D NEC: Class II, Division 1 and 2, Groups F,G NEC: Class III NEMA: 3,7BCD,9FG,12 CEC: Class I, Division 1 and 2, Groups B,C,D CEC: Class II, Division 1 and 2, Group G CEC: Class III Encl. 3,4

Circuit breaker

1059 1060

APJ/NPJ

Circuit breaker: 225 amp. frame size 600VAC/250VDC Receptacle: 200 amp. 3-wire, 4-pole Circuit breaker: 100 amp. frame size 600VAC/250VDC Receptacle: 30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole

1040

STIBOINFO((CRH:66008com:4P:1040)) CH0 0 4 P - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Page

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1041-3 Name: 4P-1041

100: DATE: JAN 19 2006

Time: 6:10:14 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Plugs and Receptacles

csm no.: 100

4P

Industrial Heavy Duty Interlocked Quick Selector and Interchangeability Chart Hazardous Quick Selector Chart NEC/CEC & NEMA/EEMAC Compliances

Receptacles Interlocked With

Page

Mating Plugs

Electrical Rating

NEC: Class I, Division 1 and 2, Groups B,C,D NEC: Class II, Division 1 and 2, Groups F,G NEC: Class III NEMA: 3,7BCD,9FG,12 CEC: Class I, Division 1 and 2, Groups B,C,D CEC: Class II, Division 1 and 2, Group G CEC: Class III Encl. 3,5

Switch

1043

APJ/NPJ

1044 1045 1046

BP FP

30A 250V/20A 600VAC 2-wire, 3-pole 3-wire, 4-pole 60A & 100A 2-wire, 3-pole 2-wire, 3-pole 3-wire, 4-pole

W2SR

NEC/CEC: Class I, Division 2, Groups B,C,&D NEC: Class I, Zone 2, Group IIB + Hydrogen NEMA 3R

Rotary Switch

1048

APJ/NPJ

30A,60A,100A 3-wire, 3-pole 3-wire, 4-pole

SRD

Class I, Division 1 and 2, Group D Class II, Division 1 and 2, Groups F,G Class III NEMA: 3,7D,9FG,12

Factory Sealed Switch

1051 1052

5P

30 & 60 amp. 480VAC 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

Series FSQ

Interchangeability Chart Many of the plugs listed in this section can be used interchangeably with receptacles from other sections, both in hazardous and nonhazardous areas, provided electrical rating and style of plug and receptacle are the same. The following table is a summary of possible combinations.

Listed in Section

Plug & Receptacle Electrical Rating

AR, NR DR FSQ, EPC, EPCB, DBR, EBBR, C2SR, FSQC, C2SR, DSR, DBR, NBR, NSR, W2SR, WSR, CSR, WSRD, WSRDW, WSQC, DSR, WSRDCHS901

1P 2P 4P

30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole

3P

30, 60, 100 amp. 3-wire, 3-pole 3-wire, 4-pole

BHP

SRG SRD BHR

3P 4P 4P

30, 60, 100 amp. 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

SP

SRG BHR SRD

3P 4P 4P

30, 60 amp. 2-wire, 3-pole 3-wire, 4-pole 4-wire, 5-pole

Plugs Shown in Section 4P APJ/NPJ

Can be Used with These Receptacle Series

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1041)) CH0 0 4 P - 1

CAN: 1-800-265-0502

CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

Copyright© 2006 Cooper Crouse-Hinds

1041

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1042-3 Name: 4P-1042

4P

100: DATE: JAN 19 2006

Time: 6:10:15 PM Operator: RB

FSQ Dead Front Interlocked Receptacles and Switches

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B*,C,D Cl. II, Div. 1 and 2, Groups F,G Cl. III

Explosionproof Dust-Ignitionproof Raintight Wet Locations

APJ/NPJ, BP and FP Plugs

Application: FSQ dead front interlocked receptacles and switches with APJ/NPJ, BP and FP plugs are used: ɀ to supply power to portable electrical equipment such as hand lamps, lighting systems, power tools, conveyors and similar equipment. ɀ in areas which are hazardous due to the presence of flammable vapors or gases and combustible dusts. ɀ in damp, wet or corrosive locations ɀ indoors or outdoors at petroleum refineries, chemical and petrochemical plants and facilities for processing and handling grain, flour and starch.

Features: ɀ FSQ dead front interlocked receptacles and switches, as shown in the listings, are available with four different types of receptacles, each of which is positively polarized to prevent mismating. With this choice of receptacle types, power outlets for several different voltages can be installed in the same area with assurance that portable equipment cannot be conected to a receptacle of improper voltage. ɀ All FSQ assemblies have the same outstanding safety features. The plug must be fully inserted in the receptacle and rotated clockwise to operate the enclosed switch, closing the circuit to the receptacle. The plug cannot be withdrawn until it is rotated counter-clockwise and the switch opened. Plug and receptacle contacts cannot be made or broken under load and when plug and receptacle are not engaged, receptacle is dead front. ɀ An added safety feature is provided by the cover screw. The cover cannot be removed when the switch is closed and with the cover removed and cover screw in place, the switch cannot be operated by the plug.

Certifications and Compliances: ɀ NEC: Class I, Division 1 and 2, Groups B*,C,D Class II, Division 1 and 2, Groups F,G Class III ɀ NEMA: 3,7B*CD,9FG,12 ɀ ANSI/UL Standard: 1010 ɀ CEC: Class I, Division 1 and 2, Groups B,C,D Class II, Division 1 and 2, Group G Class III ɀ Encl. 3,5 ɀ CSA Standard: C22.2 No. 30 CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

Dimensions:

Interchangeability of Plugs with Other Hazardous and Non-Hazardous Location Receptacles: ɀ Plugs listed for FSQC receptacles on 1043 are standard APJ/NPJ plugs. Other standard APJ/NPJ and CPH plugs of the same rating, style and number of poles may be used with FSQC receptacles as well as with DR, DBR, EBBR, EPC and EPCB receptacles listed in Section 2P and 4P. ɀ As a result, portable equipment suitable for the location and equipped with the proper plug can be used with AR series receptacles for non-hazardous areas, EBBR, EPC, EPCB, and FSQC receptacles for Class I hazardous locations; DR and DBR receptacles for Class II hazardous locations.

FSQC5630, 5640

Grounding: ɀ NEC Article 501 and CEC Part 1 Section 18 requires that metal frames or exposed noncurrent-carrying metal parts of portable devices used in hazardous areas be grounded through an extra conductor in the portable cord. ɀ All FSQ receptacles and matching plugs are provided with an extra grounding pole. In the plugs, provision is made for attachment of the grounding wire. In addition, direct connection is provided between plug and receptacle housings and the grounding pole. If a separate grounding wire is not installed in the receptacle, grounding is accomplished through the conduit system.

Cat. # FSQC2320, 3320 FSQC2430, 3430 FSQC2390, 3390 FSQ230, 330 Series FSQ232, 332 Series FSQ233, 333 Series

Page

Maximum Dimensions a b c

d

e

f

4P-3

43⁄4

31⁄8

53⁄4

93⁄4

3⁄8

4P-4

43⁄4

65⁄8

31⁄8

53⁄4

101⁄4

3⁄8

4P-5

43⁄4

65⁄8

31⁄8

51⁄2

91⁄2

3⁄8

* FSQC units on page 1043 are listed for Class I, Group B, NEMA 7. FSQ units on pages 1045 & 1046 require suffix ‘‘GB’’.

1042

STIBOINFO((CRH:66008com:4P:1042)) CH0 0 4 P - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1043-1 Name: 4P-1043

DATE: JAN 19 2006

Time: 6:10:16 PM Operator: RB

FSQC Arktite® Dead Front Interlocked Receptacles and Switches

COLOR: CMYK

Cl. I, Div. 1 and 2, Groups B,C,D Cl. II, Div. 1 and 2, Groups F,G Cl. III NEMA/EEMAC 3,7BCD,9FG,12

TCP: 15001

Typedriver Name: TS name

Explosionproof Dust-Ignitionproof Raintight Wet Locations

csm no.: 100

4P

APJ/NPJ Arktite Plugs Applications:

Materials:

FSQC dead front switched interlock receptacles are used: ɀ to supply power to portable electrical equipment such as hand lamps, lighting systems, power tools, conveyors, welders and similar equipment. ɀ in areas which are hazardous due to the presence of flammable vapors or gases and combustible dusts. ɀ in damp, wet or corrosive locations. ɀ indoors or outdoors at petroleum refineries, chemical and petrochemical plants and facilities for processing and handling grain, flour and starch.

ɀ Enclosure – Feraloy® iron alloy or copperfree aluminum ɀ Cover and spring door – copper-free aluminum ɀ Insulator – Krydon® ɀ Contacts – brass

Product Features: ɀ Compatible with Arktite® APJ aluminum and NPJ Krydon® plugs ɀ Switch cannot be turned ‘‘ON’’ until plug is fully inserted and rotated. ɀ Plug cannot be withdrawn under load ɀ Cover cannot be removed when switch is ‘‘ON’’ ɀ Satisfies OSHA lockout tagout requirement. ɀ Smallest mounting footprint for interlocks

Certifications and Compliances: ɀ NEMA 3, 7BCD, 9FG, 12 ɀ NEC/CEC: Class I, Division 1 & 2, Groups B, C & D Class I, Zone 1, Group IIB+Hydrogen Class II, Division 1 & 2, Groups F, G Class III ɀ ANSI/UL Standards 1010 UL Listed ɀ CSA Standard C22.2 No. 30 cUL Listed & C22.2 No. 159

Options: Description Special polarity, receptacle interior rotated 221⁄2° Copper-free aluminum enclosure – 60A only

Suffix S4 SA

Ordering Information: Amps

Hub 3⁄4⍯

30A 1⍯ 11⁄2⍯

60A

Config. 2W3P 3W4P 2W3P 3W4P 2W3P 3W4P

Description 2 Pole Switch 3 Pole Switch 2 Pole Switch 3 Pole Switch 2 Pole Switch 3 Pole Switch

Catalog Number FSQC2320 FSQC2430 FSQC3320 FSQC3430 FSQC5630 FSQC5640

Matching Plug APJ3385 APJ3485 APJ3385 APJ3485 APJ6385 APJ6485

FSQC Receptacles With Spring Door (Through Feed Hubs)

Horsepower Rating: Amps 30A 60A

120V 2 —

Single Phase 240V 480V 5 71⁄2 10 25

600V 71⁄2 30

Amps 30A 60A

120V 3 —

Three Phase 240V 480V 71⁄2 15 10 25

600V 15 30

FSQC for Use with Magnetic Motor Starters or Contactors FSQC units listed below operate in the same way as standard units but are intended only for use with magnetic motor starters or contactors. (Wiring diagram 1) Receptacles have leads for splicing to conductors from the load side of contactor. The switch actuated by the plug is wired into the starter or contactor coil circuit and controls only this circuit. The starter or contactor is energized only when the plug is fully inserted and rotated to close the switch. Since the plug is inserted or withdrawn only when the switch is open, the circuit cannot be made or broken under the load. Plugs used are standard APJ units and special polarity units listed are recommended where interchange with devices for other wiring systems is possible.

FSQC Receptacles

APJ/NPJ Plugs

With Spring Door (Through Feed Hubs) 30 Amperes, 250 VAC or VDC; 20 Amperes, 600 VAC No. of Poles

Hub Size 3⁄4 3⁄4

3-wire 4-pole 1 1

Receptacle Cat. # FSQC2390 FSQC2390-S4

}

FSQC3390 FSQC3390-S4

Cable Dia. 0.60 to 1.20 0.55 to 0.70 0.70 to 0.85

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1043)) CH0 0 4 P - 3

{ { {

Plug Cat. # APJ3485 APJ3485-S4 NPJ3483 NPJ3483-S4 NPJ3484 NPJ3484-S4

CAN: 1-800-265-0502

Wiring Diagram 1 (FSQC2390 and 3390 only)

Copyright© 2006 Cooper Crouse-Hinds

1043

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1044-1 Name: 4P-1044

4P

100: DATE: JAN 19 2006

ɀ to supply power to portable or fixed electrical equipment such as welders, pumps, motors, machine tools, conveyors, oil rigs, mixers grain elevators, petroleum refineries, chemical and petrochemical plants ɀ in hazardous areas containing flammable vapors or gases and combustible dusts ɀ in damp, wet or hosedown environments ɀ in highly corrosive locations

Features: ɀ NEMA Type 4 watertight ɀ suitable for Group B ɀ compact housing ɀ simple operation ɀ compatible with Arktite® APJ aluminium and NPJ Krydon® plugs ɀ H.P.-rated enclosed switch ɀ 4 mounting feet can be rotated for flexibility in positioning to surface ɀ wiring channel provided under switch for easy wire routing to terminals ɀ dual botton-feed hubs and one top hub for convenient feed-through installation ɀ bread-loose fork lugs case in place for easy removal of cover

Safety First: ɀ power cannot be turned ‘‘on’’O until plug is fully inserted and Uni-Loc collar is rotated ɀ when Uni-Loc collar is in ‘‘on’’ position, plug is locked in place to prevent disengagement under load ɀ cover cannot be removed while switch is ‘‘on’’ ɀ Cover-Loc TM design prevents switch from being turned ‘‘on’’ while cover is removed ɀ Uni-Loc collar aligns with lug on housing to permit OSHA lockout/tagout in the ‘‘off’’ position

STIBOINFO((CRH:66008com:4P:1044)) CH0 0 2 C- 3

COLOR: CMYK

TCP: 15001

Materials: ɀ body—copper–free aluminum ɀ cover—copper–free aluminum ɀ locking collar—Feraloy®iron alloy ɀ insulator—Krydon® material ɀ contacts—brass

Certifications and Compliances: ɀ NEMA 3, 3R, 4, 4X*, 7BCD, 12 ɀ Class I, Divisions 1 & 2, Groups B,C & D ɀ Class I, Zone 1, Group IIB + H2 ɀ Class II, Divisions 1 & 2, Groups F & G ɀ Class III ɀ ANSI/UL Standards 1010 & 98 UL Listed ɀ cUL Listed, CSA Standard C22.2 No. 30, C22.2 No. 159 刁 NEMA 4X when ordered with suffix S752

Electrical Rating: 100A, 600VAC

Ordering Information: Hub H.P. Rating Config. Size Rating Cat. # 100A, 3W4P 2⍯ 50 H.P. FSQC61040 600VAC @600V, 480V

Options: Special polarity—receptacle interior rotated 221⁄2° to right. Add suffix . . . . . . . . . . . . . . . S4 (example: FSQC61040 S4) NEMA 4X—epoxy powder coated. Add suffix . . . . . . . . . . . . . . . . . . . . . . . . . S752 (example: FSQC61040 S752) Auxiliary contact. Add suffix . . . . . . . . . . S483 Breather/Drain . . . . . . . . . . . . . . . . . . . . S756V

US: 1-866-764-5454

CAN: 1-800-265-0502

Typedriver Name: TS name

Cl. I, Div. 1 and 2 Groups B,C,D NEMA 4 Cl. II, Div. 1 and Groups F,G Watertight Cl. III NEMA 3,3R,4,4X,7BCD,9FG,12 Explosionproof

100 Amp FSQ Dead Front Interlocked

Applications:

1044

Time: 6:10:17 PM Operator: RB

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1045-1 Name: 4P-1045

DATE: JAN 19 2006

Time: 6:11:17 PM Operator: RB

FSQ Dead Front Interlocked Receptacles and Switches BP Plugs

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B*,C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA/EEMAC 3,7BCD,9FG,12 Explosionproof

csm no.: 100

4P

Note:

*Class I, Group B:

ɀ For information on application, features, groundings and compliances, see page 1042. ɀ Available with 3⁄4⍯ and 1⍯ hubs in various arrangements, as shown in the listings.

FSQ units listed below are also available modified for Class I, Group B (NEMA 7B) usage. Add suffix GB to the Cat. No. Example: FSQC230-GB. Seals must be installed within 11⁄2⍯ of each conduit opening.

Standard Materials: ɀ Switch enclosure and receptacle housing – Feraloy® iron alloy ɀ Threaded cover and spring door – copperfree aluminum ɀ Plug exteriors; handle body – copper-free aluminum ɀ Protective sleeve – steel ɀ Insulation (plug and receptacle) – Krydon® fiberglass reinforced polyester ɀ Contacts – brass

Standard Finishes: ɀ Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Steel – zinc electroplate with chromate finish ɀ Brass – natural ɀ Krydon, fiberglass reinforced polyester – natural (red)

FSQ Receptacles With Spring Door

BP Plugs

30 Amperes, 250 VAC or VDC; 20 Amperes, 600 VAC; 2 HP, 120-600 VAC

With Cable Grip and Neoprene Bushing

No. of Poles

Hub Size

Hub Arrangement

Cat. #

Hub Arrangement

Cat. #

3⁄4 1

FSQC230 FSQC330

FSQD230 FSQD330

3⁄4 1

FSQA230 FSQA330

FSQX230 FSQX330

2-wire, 3 pole (2-pole switch)

Cable Dia. .375 to .500 .500 to .625 .625 to .750 .750 to .875

Cat. # BP49 BP59 BP69 BP79

CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1045)) CH0 0 4 P - 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1045

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1046-1 Name: 4P-1046

100: DATE: JAN 19 2006

Time: 6:11:19 PM Operator: RB

FSQ Dead Front Interlocked Receptacles and Switches

4P

FP Plugs

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B*,C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA/EFC 3,7B*CD,9FG,12 Explosionproof

Note:

* Class I, Group B: FSQ units listed below are also available modified for Class I, Group B (NEMA 7B) usage. Add suffix GB to the Cat. No. Example: FSQC232-GB. Seals must be installed within 11⁄2⍯ of each conduit opening.

ɀ For information on application, features, groundings and compliances, see page 1042. ɀ Available with 3⁄4⍯ and 1⍯ hubs in various arrangements, as shown in the listings.

Standard Materials: ɀ Switch enclosures and receptacle housings – Feraloy® iron alloy ɀ Threaded covers – copper-free aluminum ɀ Plug exteriors – FP323 and FP334 – copper-free aluminum ɀ Insulation: receptacles – Krydon® fiberglass reinforced polyester; FP323 and FP334 plugs – Krydon® fiberglass reinforced polyester ɀ Contacts – brass

Standard Finishes: ɀ Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Krydon-fiberglass reinforced polyester – natural (red) ɀ Brass – natural

Options: ɀ Addition of cap and chain (copper-free aluminum, natural finish) to FSQ assemblies with threaded housing protects interior when plug is not in use. Add suffix S1 to Cat. No.

FSQ Receptacles

FP Plugs

With Threaded Housing 30 Amperes, 250 VAC or VDC; 20 Amperes, 600 VAC; 2 HP, 120-600 VAC No. of Poles 2-wire 3-pole

2-wire 3-pole

Hub Size 3⁄4 1

3⁄4

1

Switch

Hub Arrangement

2-pole

Cat. # FSQC232 FSQC332

Hub Arrangement

FSQA232 FSQA332

2-pole

Cat. # FSQD232 FSQD332

With Cable Grip and Neoprene Bushing No. of Poles 2-wire, 3-pole 3-wire, 4-pole

FSQX232 FSQX332

30 Amperes, 240 VAC; 20 Amperes, 600 VAC; 2 HP, 120-600 VAC 3-wire 4-pole

3⁄4

3-wire 4-pole

3⁄4

1

1

1046

STIBOINFO((CRH:66008com:4P:1046)) CH0 0 4 P - 5

3-pole

FSQC233 FSQC333

FSQD233 FSQD333

3-pole

FSQA233 FSQA333

FSQX233 FSQX333

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Cable Dia.

Cat. #

.500 to .875

FP323

.500 to .875

FP334

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1047-1 Name: 4P-1047

100: DATE: JAN 19 2006

Time: 6:11:20 PM Operator: RB

DSR Interlocked Arktite® Receptacle with Enclosed Disconnect Switches

COLOR: CMYK

Cl. II, Div. 1 and 2, Group G Cl. III NEMA: 3,9G,12 Encl. 3,5 Dust-Ignitionproof

TCP: 15001

Typedriver Name: TS name

Raintight

csm no.: 100

4P

Dimensions:

Application: ɀ The DSR disconnect switches are used as a service outlet for portable or fixed electrical equipment – generators, compressors, welders, etc. ɀ They are designed for use in hazardous and non-hazardous areas where dust, moisture and corrosion may be a problem. ɀ Designed for surface mounting. ɀ A fusible type switch, when used, also provides short circuit protection.

Features: ɀ Switches ɀ Type DS disconnect is a compact load break switch using the De-ion arc quenching principle and quick make-break over center toggle mechanism. It has visible contacts, is CSA listed up to 30 hp., and is available either as a fusible or non-fusible switch. ɀ Enclosures are compact and rectangular in shape permitting close spacing with a gasketing cover. ɀ For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the switch operating mechanism. The switch cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the switch is open. ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. ɀ Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a thread-in bushing. The size furnished is 11⁄2⍯, and removing the bushing permits the use of a 2⍯ conduit.

Options: Standard Materials: ɀ Bodies, covers and operating handles – copper-free aluminum. ɀ Operating shafts – stainless steel. ɀ Receptacle housings and plug exteriors – copper-free aluminum. ɀ Insulation: plugs and receptacles – fiberglass-reinforced polyester. ɀ Contacts – brass.

Standard Finishes: ɀ Copper-free aluminum – natural. ɀ Stainless steel – natural. ɀ Brass – Bright Dip. ɀ Fiberglass-reinforced polyester – natural (red).

Electrical Rating Ranges: ɀ 3-Wire, 4-Pole: Fusible or non-fusible: 240VAC 250vdc: 600 vac 60, 100 amperes ɀ 15 to 75 hp

The following special options are available by adding suffix to Cat. No. Description Special polarity for use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available as follows: ɀ Receptacle interior rotated 221⁄2 degrees to right (viewed from face) and plug changed to match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4 ɀ Breather (drain furnished as standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . S219 ɀ Conduit arrangements other than standard can be supplied . . . . . . . . Details on request.

Certifications and Compliances: ɀ NEC/CEC: Class II, Division 1 and 2, Group G Class III ɀ Encl. 3,5 ɀ NEMA 3,9G,12

Ordering Information:

System 3-Wire, 4-Pole Style 2, Fusible 3-Wire, 4-Pole Style 2, Non-Fusible

Amps 60 100 60 100

Conduit Opening Sizes 11⁄2 11⁄2 11⁄2 11⁄2

Max. HP Rating 240VAC 15 30 15 30

Max. HP Rating 600VAC 50 75 50 75

DSR 240VAC 250VDC Cat. # DSR632** DSR6342 DSR10342

600VAC 250VDC Cat. # DSR6352* DSR10352* DSR63542 DSR103542

* Arranged for Class J fuses. ** Arranged for Class H fuses.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1047)) CH0 0 4 P - 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1047

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1048-1 Name: 4P-1048

DATE: JAN 19 2006

Time: 6:11:22 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

W2SR Metallic Interlocked Arktite® Receptacles

4P

Division 2

W2SR Interlocked Arktite® Receptacles Product Features:

ɀ NEMA 3R ɀ Rainproof locations ɀ Available in 30, 60 & 100 amps ɀ RSWP factory-sealed explosionproof switch ɀ No external seals required ɀ Hinged door mechanically interlocked with operating handle ɀ Operating handle meets OSHA lockout/tagout requirements ɀ Compatible with Arktite® APJ aluminum and NPJ Krydon® material non-metallic plugs

Materials:

ɀ Enclosure – copper-free aluminum ɀ Operating handle – copper-free aluminum ɀ Other exterior parts – stainless steel ɀ Receptacle housings – copper-free aluminum ɀ Insulator — Krydon® material ɀ Crimp/solder contacts – leaded red brass ɀ Pressure contacts – brass

Certifications and Compliances:

ɀ NEMA 3R ɀ NEC/CEC: Class I, Division 2, Groups B, C & D ɀ NEC: Class I, Zone 2, Group IIB+Hydrogen ɀ UL Standards 508, 1604, 1682 UL Listed ɀ CSA Standard C22.2 No. 182.1 & No. 213 cUL Listed

Horsepower Ratings:

Dimensions: (In Inches)

Single Phase 120V 240V

Amps 30A 60A 100A

2 3 5

3 71⁄2 10

120V 3 71⁄2 10

Three Phase 240V 480V 71⁄2 15 20

15 30 40

600V 20 40 60

Ordering Information: Amps

Hub

30A

1⍯

60A

11⁄4⍯

100A

11⁄2⍯

Config.

Catalog No.

3W3P 3W4P 3W3P 3W4P 3W3P 3W4P

W2SR33541 W2SR33542 W2SR63541 W2SR63542 W2SR103541 W2SR103542

OPTIONS – The following options are available from the factory by adding suffix to the catalog number: 1) Receptacle interior rotated 221⁄2° . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4

1048

STIBOINFO((CRH:66008com:4P:1048)) CH0 0 4 P - 8

US: 1-866-764-5454

CAN: 1-800-265-0502

A B C D E F Mtg. Holes

Copyright© 2006 Cooper Crouse-Hinds

30 Amps

60 Amps

100 Amps

113⁄4 201⁄16 69⁄16 71⁄4 215⁄32 2711⁄16 3⁄8

113⁄4 201⁄16 69⁄16 71⁄4 215⁄32 2811⁄16 3⁄8

147⁄8 265⁄16 99⁄16 81⁄4 27⁄8 353⁄8 7⁄16

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1049-1 Name: 4P-1049

100: DATE: JAN 19 2006

Time: 6:11:23 PM Operator: RB

BHP Plugs BHR dead front interlocked receptacles and switches with BHP plugs are used: ɀ to supply power to portable electrical equipment such as motor-generator sets, compressors, heating and cooling units, lighting systems, conveyors, and similar equipment ɀ primarily in areas which are hazardous due to the presence of hydrogen or gases, or vapors of equivalent hazard such as manufactured gas ɀ in damp, wet, or corrosive locations ɀ indoors or outdoors in hydrogen areas of process industries, missile bases where hydrogen fuel is used, and gas manufacturing plants

Features: ɀ BHR receptacles feature a built-in rotary switch which is operated automatically when the plug is inserted and withdrawn. The switch, capable of making and breaking the circuit at full rated load, is operated by a helical blade in the center of the plug ɀ The plug and receptacle contacts cannot be made or broken under load. When the plug is inserted, the plug and receptacle contacts engage before the switch closes. When the plug is withdrawn, the switch opens before the plug and receptacle contacts disengage. This sequence of operation provides maximum safety in a dead front receptacle. Arcing is isolated in a flame and dust-tight chamber ɀ Operation is simple, safe and positive. To disconnect the portable device, the plug fastening ring is unscrewed and the plug simply pulled straight out. No separate interlock device or operating handle need be actuated ɀ Positive engagement without mismatching is assured by a distinct physical polarization of the plug and receptacle in every rating ɀPlugs are furnished with pressure terminations. Receptacles are furnished with flexible leads for splicing to the supply conductors. A large threaded cover provides access to the wiring compartment ɀ As shown in the listings, assemblies are available for top, bottom or through feed conduit arrangements in 3⁄4⍯ to 2⍯ sizes

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B,C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA 3,4,7BCD,9FG,12 Explosionproof

BHR Dead Front Interlocked Receptacles with Factory Sealed Switch Application:

COLOR: CMYK

csm no.: 100

4P

Standard Materials: ɀ Receptacle housings – copper-free aluminum ɀ Seals – malleable iron ɀ Plug exteriors – copper-free aluminum ɀ Insulation – high impact glass filled phenolic ɀ Contacts – brass

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Malleable iron – electrogalvanized and aluminum lacquer ɀ Phenolic – natural (black) ɀ Brass – silver plated

Options: ɀ Special polarity – where two or more receptacles of the same ampere rating and number of poles are to be installed in the same areas for use on different voltages, alternate polarizations can be furnished. Details on request

BHR/BHP in use

Electrical Rating Ranges: ɀ 30, 60 and 100 amperes, 480vac

Certifications and Compliances: ɀ Class I, Division 1 and 2, Groups B,C,D Class II, Division 1 and 2, Groups F,G Class III ɀ NEMA: 3,4,7BCD,9FG,12 ɀ ANSI/UL Standard: 1010 CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts

BHR/BHP Separated showing helical driver

Dimensions: (in inches) BHR/BHP

BHR only

Grounding: ɀ BHR receptacles and BHP plugs are provided with an extra grounding pole. In plugs, provision is made for attachment of the grounding wire to the grounding pole. In addition, direct connection is provided between the plug and receptacle housings and the grounding pole. In the receptacle, grounding is accomplished through the conduit system

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1049)) CH0 0 4 P - 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1049

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1050-1 Name: 4P-1050

DATE: JAN 19 2006

Time: 6:11:24 PM Operator: RB

BHR Dead Front Interlocked Receptacles with Factory Sealed Switch

4P

BHP Plugs 480 VAC, 60-400 hertz

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 and 2, Groups B,C,D Cl. II, Div. 1 and 2, Groups F,G Cl. III NEMA 3,4,7BCD,9FG,12

RECEPTACLE Receptacles are supplied ready to install with a threaded cap. Through feed hubs are standard. Sealing fittings, nipples and closure plugs ordered seperatley depending on application. Receptacles can be configured for Top Feed, Bottom feed or Through feed. Order required parts in catalog section 6C.

AMPS 30

60

100

CONFIG.

HUB SIZE

CATALOG #

2 wire 3 pole 2 wire 3 pole 3 wire 4 pole 3 wire 4 pole 4 wire 5 pole 4 wire 5 pole

3⁄4

1 3⁄4 1 1 1 1⁄4

BHRC3382N BHRC3383N BHRC3482D BHRC3483D BHRC3583NW BHRC3584NW

2 wire 3 pole 2 wire 3 pole 3 wire 4 pole 3 wire 4 pole 4 wire 5 pole 4 wire 5 pole

1 1⁄4 1 1⁄2 1 1⁄4 1 1⁄2 1 1⁄4 1 1⁄2

BHRC6384N BHRC6385N BHRC6484D BHRC6485D BHRC6584NW BHRC6585NW

2 wire 3 pole 2 wire 3 pole 3 wire 4 pole 3 wire 4 pole 4 wire 5 pole 4 wire 5 pole

1 1⁄4 1 1⁄2 1 1⁄2 2 1 1⁄2 2

BHRC10384N BHRC10385N BHRC10485D BHRC10486D BHRC10585NW BHRC10586NW

PLUGS Plugs mate to BHR receptacles. Plugs are supplied with threaded locking ring that threads onto receptacle housing for secure connection and environmental seal. Mechanical external cord grip and neoprene bushing provided for secure cord retention and environmental seal.

AMPS 30

60

100

1050

STIBOINFO((CRH:66008com:4P:1050)) CH0 4 P - 1 0

CONFIG.

CABLE DIA.

CATALOG #

2 wire 3 pole 2 wire 3 pole 3 wire 4 pole 3 wire 4 pole 4 wire 5 pole 4 wire 5 pole

.500 - .875 .875 - 1.375 .500 - .875 .875 - 1.375 .500 - .875 .875 - 1.375

BHP3383N BHP3385N BHP3483D BHP3485D BHP3583NW BHP3585NW

2 wire 3 pole 2 wire 3 pole 3 wire 4 pole 3 wire 4 pole 4 wire 5 pole 4 wire 5 pole

.500 - .875 .875 - 1.375 .500 - .875 .875 - 1.375 .875 - 1.375 1.375 - 1.875

BHP6383N BHP6385N BHP6483D BHP6485D BHP6585NW BHP6587NW

2 wire 3 pole 2 wire 3 pole 3 wire 4 pole 3 wire 4 pole 4 wire 5 pole 4 wire 5 pole

.875 - 1.375 1.375 - 1.875 .875 - 1.375 1.375 - 1.875 .875 - 1.375 1.375 - 1.875

BHP10385N BHP10387N BHP10485D BHP10487D BHP10585NW BHP10587NW

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name

Explosionproof Dust-Ignitionproof Raintight Wet Locations

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1051-1 Name: 4P-1051

DATE: JAN 19 2006

Time: 6:11:25 PM Operator: RB

Dead Front Interlocked Receptacles with Factory Sealed Switch SP Plugs 480 VAC, 60-400 hertz Application: SRD dead front interlocked receptacles, switches, and SP plugs are used: ɀ to supply power to portable electrical equipment such as motor-generator sets, compressors, heating and cooling units, lighting systems, conveyors and similar equipment ɀ in areas which are hazardous due to the presence of flammable vapors or gases and combustible dusts ɀ in damp, wet or corrosive locations ɀ indoors or outdoors at petroleum refineries, chemical and petrochemical plants, as well as facilities for processing and handling grain, flour and starch

Features: ɀ SRD receptacles feature a built-in rotary switch that operates automatically when the plug is inserted and withdrawn. The switch, capable of making and breaking the circuit at full rated load, is operated by a helical blade in the center of the plug. ɀ The plug and receptacle contacts cannot be made or broken under load. When the plug is inserted, the plug and receptacle contacts engage before the switch closes. When the plug is withdrawn, the switch opens before the plug and receptacle contacts disengage. This sequence of operation provides the maximum safety of a dead front receptacle. Arcing is isolated in a flame and dust-tight chamber. ɀ Operation is simple, safe and positive. To disconnect the portable device, the plug is simply pulled straight out. No separate interlock device or operating handle need be actuated. ɀ Positive engagement without mismating is assured by a distinct physical polarization of plug and receptacle in every rating. ɀ Plugs are furnished with pressure terminations. Receptacles are furnished with flexible leads for splicing to the supply conductors. A threaded cover at the top provides access to the wiring compartment. ɀ Back box is provided with 11⁄4⍯ vertical through feed hubs.

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Group D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA 3,7D,9FG,12 Explosionproof

csm no.: 100

4P

ɀ Insulation – high impact glass filled phenolic ɀ Contacts – brass

Standard Finishes: ɀ Feraloy iron alloy – electrogalvanized and aluminum acrylic paint ɀ Copper-free aluminum – natural ɀ Phenolic – natural (black) ɀ Brass – silver plated

Options: ɀ Special polarity – where two or more receptacles of the same ampere rating and number of poles are to be installed in the same area for use on different voltages, alternate polarizations can be furnished. Details on request.

Electrical Rating Ranges: ɀ 30 and 60 amperes, 480vac

Certifications and Compliances: ɀ NEC: Class I, Division 1 and 2, Group D Class II, Division 1 and 2, Groups F,G Class III ɀ NEMA 3,7D,9FG,12 ɀ ANSI/UL Standard: 1010 CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

Dimensions: (in inches)

Grounding: ɀ SRD receptacles and SP plugs are provided with an extra grounding pole. In plugs, provision is made for attachment of a grounding wire to the grounding pole. In addition, direct connection is provided between plug and receptacle housings and the grounding pole. In the receptacle, grounding is accomplished through the conduit system.

Standard Materials: ɀ Back box – Feraloy® iron alloy ɀ Threaded cover – copper-free aluminum ɀ Receptacle housings and plug exteriors – copper-free aluminum

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1051)) CH0 4 P - 1 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1051

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1052-1 Name: 4P-1052

DATE: JAN 19 2006

Time: 6:11:26 PM Operator: RB

SRD Dead Front Interlocked Receptacles with Factory Sealed Switch

4P

SP Plugs 480 VAC, 60-400 hertz

SRD Receptacle with spring door

COLOR: CMYK

TCP: 15001

Cl. I, Div. 1 and 2, Group D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA 3,7D,9FG,12 Explosionproof

SRD Receptacle with threaded cap

SP Plug

Typedriver Name: TS name

SP Plug with fastening ring

Back Box – 11⁄4⍯ Vertical Through Feed Hubs

Rating

Description 2-wire, 3-pole

With Spring Door Cat. # SRD3324N

With Threaded Cap Cat. #

With Cable Grip and Neoprene Bushing Cable Dia. Cat. # ⎧ .500 to .875 SP3363N ⎩ .875 to 1.375 SP3365N

SRD3384N

With Cable Grip and Neoprene Bushing Cable Dia. Cat. # ⎧ .500 to .875 SP3383N ⎩ .875 to 1.375 SP3385N

3-wire, 4-pole

SRD3424D

⎧ .500 to .875 ⎩ .875 to 1.375

SP3463D SP3465D

SRD3484D

⎧ .500 to .875 ⎩ .875 to 1.375

SP3483D SP3485D

4-wire, 5-pole

SRD3524-NW

⎧ .500 to .875 ⎩ .875 to 1.375

SP3563-NW SP3565-NW

SRD3584-NW

⎧ .500 to .875 ⎩ .875 to 1.375

SP3583-NW SP3585-NW

2-wire, 3-pole

SRD6324N

⎧ .500 to .875 ⎩ .875 to 1.375

SP6363N SP6365N

SRD6384N

⎧ .500 to .875 ⎩ .875 to 1.375

SP6383N SP6385N

3-wire, 4-pole

SRD6424D

⎧ .500 to .875 ⎩ .875 to 1.375

SP6463D SP6465D

SRD6484D

⎧ .500 to .875 ⎩ .875 to 1.375

SP6483D SP6485D

4-wire, 5-pole

SRD6524-NW

⎧ .875 to 1.375 ⎩ 1.375 to 1.875

SP6565-NW SP6567-NW

SRD6584-NW

⎧ .875 to 1.375 ⎩ 1.375 to 1.875

SP6585-NW SP6587-NW

30 amp.

60 amp.

1052

STIBOINFO((CRH:66008com:4P:1052)) CH0 4 P - 1 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1053-2 Name: 4P-1053

100: DATE: JAN 19 2006

Time: 6:11:28 PM Operator: RB

EBBR Series Interlocked Arktite® Receptacles with Circuit Breakers 30, 60, 100 Amp Interlocked Receptacles

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B,C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F*,G Raintight Cl. III Wet Locations NEMA 3,3R,7BCD,9FG,12 Explosionproof

csm no.: 100

4P

Application:

Grounding:

EBBR interlocked receptacles with circuit breakers are used: ɀ As a service outlet for portable equipment – indoors or outdoors – in damp, wet, corrosive locations, without the need for a protective shelter. ɀ In areas which are hazardous due to flammable vapors, gases or combustible dust, e.g., refineries, chemical plants, and other processing and handling facilities of a hazardous nature. ɀ In areas where frequent washdowns are necessary or where heavy rain or water spray is prevalent.

EBBR interlocked receptacles and matching plugs are provided with an extra grounding pole for attaching a grounding wire. In addition, direct connection is provided between receptacle and metallic plug and the grounding pole. If a compatible non-metallic plug made of Krydon® fiberglass-reinforced polyester material is used, grounding is accomplished through the extra grounding pole only. If a separate grounding wire is not installed in the enclosure, grounding is accomplished through the conduit system.

Features: ɀ Rugged, corrosion resistant, cast copperfree aluminum construction. ɀ Accepts compatible Arktite plug of same rating and configuration. ɀ Mechanical interlock mechanism for dead front construction. ɀ Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection. ɀ A spring door receptacle, located at the bottom of the unit, is mechanically interlocked with the circuit breaker operating mechanism for safe and dependable operation. ɀ Plug and receptacle contacts cannot be made or broken under load. The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is deenergized. ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the ‘‘ON’’ position. ɀ Component operating handles located through the right side wall of the body permits visual confirmation of correct component assembly and operation. ɀ Total compliance to the wiring and room requirements of the National Electrical Code®. ɀ Semi-clamshell enclosure design, with an external machined flat joint flamepath between body and cover makes interior components easily accessible. ɀ Minimum enclosure-to-enclosure spacing with little interference between the opened cover and an adjacent enclosure. ɀ Copper-free aluminum hinges allow the cover to swing well out of the way. ɀ Stainless steel, quick release, captive, hex head cover bolts. Stainless steel springs provide clear indication cover bolts are fully retracted from body. ɀ Versatile, internal operating mechanisms allow for field adjustment to accommodate popular manufacturers’ breakers.

Standard Materials: ɀ Body, cover, and receptacle – copper-free aluminum ɀ Contact insulator (receptacles and plugs) – fiberglass-reinforced polyester ɀ Receptacle contacts – leaded red brass ɀ Pressure contacts (plugs) – brass ɀ Operating handle – copper-free aluminum ɀ Operating shafts and bushings – stainless steel ɀ Interior parts – heavy gauge sheet steel, zinc plated ɀ Cover bolts, washer and retractile springs – stainless steel ɀ Simple, straightforward installation of breaker on pre-drilled mounting plate within enclosure. ɀ Neoprene cover gasket permanently attached to the cover seals out moisture. ɀ Bodies have top drilled and tapped entrance for power conduit (11⁄2⍯) plus one at the top and one at the bottom for a breather and drain (1⁄2⍯). Breather and drain entrances are plugged. ɀ Tap-on mounting feet.

Certifications and Compliances: ɀ NEC: Class I, Division 1 and 2, Groups B,C,D Class II, Division 1 and 2, Groups F*,G Class III ɀ NEMA: 3, 3R, 7BCD, 9FG, 12 ɀ UL Standard: 1203

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Brass – natural ɀ Leaded red brass – electro-tinplated ɀ Stainless steel – natural

Electrical Rating Ranges: ɀ Circuit breakers – 20-100 amps ɀ Receptacles – 30, 60, 100 amp ɀ 3 wire, 4 pole configuration

Options: The following options are available from the factory by adding suffix to the catalog number. Receptacle interior rotated 221⁄2° to right (viewed from face) and plug changed to match. . S4 Breather (ECD13) at top, Drain (ECD11) at bottom . . . . . . S198V Group B Breather and Drain . . . S756V External Powder Epoxy Finish . . S752

* Caution: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1053)) CH0 4 P - 1 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1053

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1054-1 Name: 4P-1054

4P

DATE: JAN 19 2006

Time: 6:11:29 PM Operator: RB

EBBR Series Interlocked Arktite® Receptacles with Circuit Breakers 30, 60, 100 Amp Interlocked Receptacles

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B,C,D Cl. II, Div. 1 and 2, Groups F†,G Cl. III NEMA 3,3R,7BCD,9FG,12 Explosionproof

Dust-Ignitionproof Raintight Wet Locations

Interchangeability of Plugs with Other Hazardous and Non-Hazardous Location Receptacles: ɀ Plugs listed for use with EBBR receptacles are standard Arktite APJ/NPJ plugs. Standard APJ/NPJ and also CPH plugs of the same rating, style and number of poles may be used with EBBR receptacles, as well as with DR receptacles listed in Section 2P and DBR, EPC and EPCB receptacles listed in Section 4P of the catalog. ɀ As a result, portable equipment suitable for the location and equipped with the proper plug can be used with AR/NR series receptacles for non-hazardous locations; EBBR, EPC and EPCB receptacles for Class I and II hazardous locations; and DR and DBR receptacles for Class II hazardous locations.

Complete EBBR receptacle with circuit breaker installed.

Ordering Information Receptacle With Spring Door Housing 30 Amp 3-wire 4-pole Style 2 60 Amp 3-wire 4-pole Style 2 100 Amp 3-wire 4-pole Style 2

Hub Size 11⁄2

11⁄2

11⁄2

Circuit Breaker Rating 3-pole 480VAC+ or 250VDC

Amps 20 30 40 50

Without Circuit Breaker Cat. # EBBRA304 EBBRA304 EBBRA304 EBBRA304

w/Cutler-Hammer Breaker EBBRA304-WT20-3 EBBRA304-WT30-3 EBBRA304-WT40-3* EBBRA304-WT50-3*

w/G.E. Breaker EBBRA304-TT20-3 EBBRA304-TT30-3 EBBRA304-TT40-3* EBBRA304-TT50-3*

w/Square D Breaker EBBRA304-DT20-3 EBBRA304-DT30-3 EBBRA304-DT40-3* EBBRA304-DT50-3*

3-pole 480VAC+ or 250VDC

50 60 70 90 100

EBBRA604 EBBRA604 EBBRA604 EBBRB604 EBBRB604

EBBRA604-WT50-3 EBBRA604-WT60-3 EBBRA604-WT70-3* EBBRB604-WT90-3* EBBRB604-WT100-3*

EBBRA604-TT50-3 EBBRA604-TT60-3 EBBRA604-TT70-3* EBBRB604-TT90-3* EBBRB604-TT100-3*

EBBRA604-DT50-3 EBBRA604-DT60-3 EBBRA604-DT70-3* EBBRB604-DT90-3* EBBRB604-DT100-3*

3-pole 480VAC+ or 250VDC

50 60 70 90 100

EBBRA104 EBBRA104 EBBRA104 EBBRB104 EBBRB104

EBBRA104-WT50-3 EBBRA104-WT60-3 EBBRA104-WT70-3 EBBRB104-WT90-3 EBBRB104-WT100-3

EBBRA104-TT50-3 EBBRA104-TT60-3 EBBRA104-TT70-3 EBBRB104-TT90-3 EBBRB104-TT100-3

EBBRA104-DT50-3 EBBRA104-DT60-3 EBBRA104-DT70-3 EBBRB104-DT90-3 EBBRB104-DT100-3

+ Enclosures with 600 Volt circuit breakers are available. Add suffix ‘‘FDB’’ Ex: EBBRA304 – WT20FDB-3 * Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only, as higher trip rating may not protect wiring. † Caution: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II Group F locations that contain electrically conductive dusts.

1054

STIBOINFO((CRH:66008com:4P:1054)) CH0 4 P - 1 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1055-2 Name: 4P-1055

DATE: JAN 19 2006

Time: 6:11:30 PM Operator: RB

EBBR Series Interlocked Arktite® Receptacles with Circuit Breakers 30, 60, 100 Amp Interlocked Receptacles

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B,C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA 3,3R,7BCD,9FG,12 Explosionproof

APJ and NPJ Arktite Plugs Amps

Cable O.D. Range

csm no.: 100

4P

3-wire, 4-pole Cat. No. Krydon Aluminum material

0.60 to 1.20 0.55 to 0.70 0.70 to 0.85

APJ3485

30

0.75 to 1.45 0.75 to 1.07 1.07 to 1.35

APJ6485

60

1.00 to 1.70 0.93 to 1.21 1.21 to 1.50

APJ10487

100

NPJ3483 NPJ3484 NPJ6484 NPJ6485 NPJ10486 NPJ10487

Krydon® material NPJ series (non-metallic)

Aluminum APJ series

Both APJ and NPJ series plugs may be used with EBBR series interlocked receptacles.

Dimensions

Amps 30 60 100

EBBRA A B 19.40 22.85 19.40 23.95 19.40 24.70

C 17.25 17.25 17.25

D 14.50 14.50 14.50

EBBRB A B

C

D

26.90 26.90

24.75 24.75

22.00 22.00

31.45 32.20

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1055)) CH0 4 P - 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1055

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1056-2 Name: 4P-1056

4P

100: DATE: JAN 19 2006

Time: 6:11:31 PM Operator: RB

COLOR: CMYK

APJ/NPJɍɍ and DP Arktite Plugs Application:

Standard Finishes:

ɀ The EPC interlock receptacle is designed for use as a service outlet for portable equipment ɀ It is designed for use in damp, wet and corrosive locations, indoors or outdoors, in areas which are hazardous due to flammable vapors, gases or combustible dust. For example; refineries, chemical plants, and other processing and handling facilities of a hazardous nature

ɀ Copper-free aluminum – natural ɀ Stainless steel – natural ɀ Sheet steel – electrogalvanized with chromate finish ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate

ɀ Mechanical interlock mechanism for dead front construction ɀ Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection ɀ A spring door receptacle, located at bottom of 30, 60 and 100 ampere units and at front of 200 ampere units, is mechanically interlocked with the circuit breaker operating mechanism for maximum safety ɀ Plug and receptacle contacts cannot be made or broken under load. The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the ‘‘ON’’ position ɀ Quick installation and leveling is provided by the three-point mounting arrangement which has one keyhole slot at top and two open slots at bottom ɀ Bodies have four taper-tapped conduit hubs with integral bushings. Two are located at top and two directly below. Sizes are as shown in the listings.

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA/EFC 3,7CD,9FG,12 Explosionproof

EPC Circuit Breakers and Enclosures with Interlocked Arktite® Receptacles

Features:

TCP: 15001

Electrical Rating Ranges: ɀ Receptacle ratings: 30, 60, 100 and 200 amperes ɀ Circuit breakers: 100 and 225 ampere frame sizes

30, 60 and 100-ampere size EPC

Certifications and Compliances: ɀ NEC: Class I, Division 1 and 2, Groups C,D Class II, Division 1 and 2, Groups F,G Class III ɀ NEMA: 3,7CD,9FG,12 ɀ ANSI/UL Standard: 1010 ɀ CEC: Class I, Division 1 and 2, Groups C,D Class II, Division 1 and 2, Group G Class III Encl., 3,4

200-ampere size EPC

Options:

Grounding: ɀ EPC interlocked receptacles and matching plugs are provided with an extra grounding pole for attaching a grounding wire. In addition, direct connection is provided between plug and receptacle and the grounding pole. If a separate grounding wire is not installed in the enclosure, grounding is accomplished through the conduit system.

Standard Materials: ɀ Bodies, covers and receptacle housings – copper-free aluminum ɀ Operating handles – copper-free aluminum ɀ Operating shafts – stainless steel ɀ Interior parts – sheet steel ɀ Insulation (receptacles and plugs) – fiberglass-reinforced polyester ɀ Pressure contacts – brass ɀ Crimp/solder contacts – leaded red brass

The following special options are available by adding suffix to Cat. No. Suffix to be Added to Encl. Cat. #

Description

Special polarity – used where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available on 30, 60 and 100 ampere units as follows: ɀ Receptacle interior rotated 221⁄2 degrees clockwise when viewed from face of receptacle and plug changed to match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4 Side bosses drilled and tapped same size as standard hubs, 30, 60 and 100 ampere units only. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S366 Back boss drilled and tapped same size as standard hubs, 30, 60 and 100 ampere units only. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S367 Breather and drain (Class I, Class II). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S198V Breather and drain (Class I only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S454V CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts ɍɍ Pressure connectors are standard. Crimp/solder type terminators are optionally available for 2, 3 and 4-pole 30 ampere, 3 and 4-pole 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APJ3365-T (Plug)

1056

STIBOINFO((CRH:66008com:4P:1056)) CH0 4 P - 1 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1057-1 Name: 4P-1057

100: DATE: JAN 19 2006

Time: 6:11:32 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA/EFC 3,7CD,9FG,12 Explosionproof

EPC Circuit Breakers and Enclosures with Interlocked Arktite® Receptacles

csm no.: 100

4P

Interchangeability of Plugs with Other Hazardous and Non-Hazardous Location Receptacles: ɀ Plugs listed for use with 30, 60 and 100 ampere EPC assemblies are standard Arktite APJ/NPJ plugs. Other standard APJ and CPH plugs of the same rating, style and number of poles may be used with EPC receptacles, as well as with DR receptacles listed in Section 2P and DBR, EBBR and EPCB receptacles listed elsewhere in this section.

ɀ As a result, portable equipment suitable for the location and equipped with the proper plug can be used with AR/NR series receptacles for non-hazardous locations: EBBR, EPC and EPCB receptacles for Class I hazardous locations; DR and DBR receptacles for Class II hazardous locations.

CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts.

100 Ampere Frame Size Thermal-Magnetic Circuit Breaker with Non-Interchangeable Thermal Trip and Non-Adjustable Magnetic Trip Circuit Breaker

Enclosure Section 6C

Receptacle with Spring Door Housing Rating

Hub Size

Table

30 amp. 2-wire, 3-pole, Style 2 30 amp. 3-wire, 4-pole, Style 2

2-pole, 480VAC‡ 600VAC or 250VDC 3-pole, 480VAC‡ 600VAC or 250VDC

60 amp. 2-wire, 3-pole, Style 2

2-pole, 480VAC‡ 600VAC or 250VDC

60 amp. 3-wire, 4-pole, Style 2

3-pole, 480VAC‡ 600VAC or 250VDC

100 amp. 2-wire, 3-pole, Style 2 100 amp. 3-wire, 4-pole, Style 2

2-pole, 480VAC‡ 600VAC or 250VDC 3-pole, 480VAC‡ 600VAC or 250VDC

8

11⁄4

8

11⁄4 11⁄4

8 2 11⁄4 8 2

8

2

8

2

Ckt. Bkr. Amps 20 30 40* 50* 20 30 40* 50* 50 60 70* 90* 100* 50 60 70* 90* 100* 60 70 90 100 60 70 90 100

Without Circuit Breaker Cat. #

EPC43032

EPC43042 EPC46032 EPC66032 EPC46042 EPC66042

EPC61032

EPC61042

With Circuit Breaker Cutler-Hammer ‘‘EHD’’ Cat. #

General Electric ‘‘TED’’ Cat. #

EPC43032-WT20-2 EPC43032-WT30-2 EPC43032-WT40-2 EPC43032-WT50-2 EPC43042-WT20-3 EPC43042-WT30-3 EPC43042-WT40-3 EPC43042-WT50-3 EPC46032-WT50-2 EPC66032-WT60-2 EPC66032-WT70-2 EPC66032-WT90-2 EPC66032-WT100-2 EPC46042-WT50-3 EPC66042-WT60-3 EPC66042-WT70-3 EPC66042-WT90-3 EPC66042-WT100-3 EPC61032-WT60-2 EPC61032-WT70-2 EPC61032-WT90-2 EPC61032-WT100-2 EPC61042-WT60-3 EPC61042-WT70-3 EPC61042-WT90-3 EPC61042-WT100-3

EPC43032-TT20-2 EPC43032-TT30-2 EPC43032-TT40-2 EPC43032-TT50-2 EPC43042-TT20-3 EPC43042-TT30-3 EPC43042-TT40-3 EPC43042-TT50-3 EPC46032-TT50-2 EPC66032-TT60-2 EPC66032-TT70-2 EPC66032-TT90-2 EPC66032-TT100-2 EPC46042-TT50-3 EPC66042-TT60-3 EPC66042-TT70-3 EPC66042-TT90-3 EPC66042-TT100-3 EPC61032-TT60-2 EPC61032-TT70-2 EPC61032-TT90-2 EPC61032-TT100-2 EPC61042-TT60-3 EPC61042-TT70-3 EPC61042-TT90-3 EPC61042-TT100-3

225 Ampere Frame Size Circuit Breaker with Interchangeable Thermal Magnetic Trip† Circuit Breaker

Enclosure

Receptacle with Spring Door Housing Rating 200 amp. 3-wire, 4-pole, Style 2

3-pole, 600VAC or 250VDC

Section 6C Table

11

Hub Size

List 12W or 12T

3 3

Ckt. Bkr. Amps 125 150 175 200 225*

With Circuit Breaker Without Circuit Breaker Cat. # EPC604-2042 EPC605-2042

Cutler-Hammer ‘‘KB’’ Cat. #

General Electric ‘‘TFK’’ Cat. #

EPC604-2042-WT125-3 EPC604-2042-WT150-3 EPC604-2042-WT175-3 EPC604-2042-WT200-3 EPC604-2042-WT225-3

EPC605-2042-TT125-3 EPC605-2042-TT150-3 EPC605-2042-TT175-3 EPC605-2042-TT200-3 EPC605-2042-TT225-3

* Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only, as higher trip rating may not protect wiring. † 200 ampere units are suitable for Class I, Group D (NEMA 7D). ‡ Enclosures with 600 volt circuit breakers from U.S.A. are available. Information on request. CSA Certified units are supplied with 600VAC FDB frame circuit breakers.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1057)) CH0 4 P - 1 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1057

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1058-1 Name: 4P-1058

DATE: JAN 19 2006

Time: 6:11:32 PM Operator: RB

APJ/NPJɍɍ and DP Arktite® Plugs with Cable Grip and Neoprene Bushing

4P

APJ Plug

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups C,D Dust-Ignitionproof Cl. II, Div. 1 and 2, Groups F,G Raintight Cl. III Wet Locations NEMA/EFC 3,7CD,9FG,12 Explosionproof

NPJ Plug

DP Plug

APJ/NPJ and DP Arktite Plugs 600VAC/250VDC with Cable Grip and Neoprene Bushing – Style 2 Amps 30

60

100 200

Cable O.D. Range 0.60 to 1.20 0.55 to 0.70 0.70 to 0.85 0.75 to 1.45 0.75 to 1.07 1.07 to 1.35 1.00 to 1.70 0.93 to 1.21 1.21 to 1.50 1.875 to 2.50

2-wire, 3-pole Cat. # APJ3385 NPJ3383 NPJ3384 APJ6385 NPJ6384 NPJ6385 APJ10387 NPJ10386 NPJ10387

3-wire, 4-pole Cat. # APJ3485 NPJ3483 NPJ3484 APJ6485 NPJ6484 NPJ6485 APJ10487 NPJ10486 NPJ10487 DP20468

ɍɍ Pressure connectors are supplied as standard. To

specify crimp/solder type terminations add the suffix ‘‘T’’ to the catalog number. For example: APJ3385-T (Plug).

Solder Only .56 Wire Well

DP Wire Size Building Extra Flex #1 – 4/0 #1 – 3/0

Dimensions

APJ Recept. 30 Amp. 60 Amp. 60 Amp. 100 Amp. 200 Amp.

Breaker 20-50 Amp. 50 Amp. 70-100 Amp. 70-100 Amp. 125-225 Amp.

a 24 241⁄2 241⁄2 251⁄4 36

NPJ b 105⁄8 105⁄8 1213⁄16 1213⁄16 18

c 143⁄8 143⁄8 143⁄8 143⁄8 27

d 93⁄8 93⁄8 93⁄8 93⁄8

e 711⁄16 711⁄16 711⁄16 711⁄16 131⁄2

f 113⁄4 113⁄4 113⁄4 113⁄4

g 49⁄16 51⁄16 51⁄16 513⁄16

h 413⁄16 513⁄16 513⁄16 65⁄8

hh 7 613⁄16 613⁄16 73⁄4

Dim. ‘‘h’’ and ‘‘hh’’ are exposed portion of plug when engaged with receptacle.

1058

STIBOINFO((CRH:66008com:4P:1058)) CH0 4 P - 1 8

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

j 203⁄4 203⁄4 203⁄4 203⁄4 341⁄4

k 73⁄8 73⁄8 91⁄4 91⁄4

l 21⁄16 21⁄16 25⁄8 25⁄8

m

51⁄2

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1059-1 Name: 4P-1059

100: DATE: JAN 19 2006

Time: 6:11:34 PM Operator: RB

Cl. I, Div. 1 and 2, Groups B,C,D Cl. II, Div. 1 and 2, Groups F,G Cl. III NEMA/EFC 3,7BCD,9FG,12 Explosionproof

EPCB Circuit Breakers and Enclosures with Interlocked Arktite® Receptacles APJ/NPJ Arktite Plugsɍɍ Application: ɀ The EPCB interlock receptacle is designed for use as a service outlet for portable equipment. The circuit breaker provides overcurrent and short circuit protection ɀ It has a mechanical interlock mechanism for dead front construction and no load make or break feature ɀ It is designed for use in damp, wet and corrosive locations, indoors or outdoor, in areas which are hazardous due to flammable vapors, gases or combustible dust. For example; refineries, chemical plants, and other processing and handling facilities of a hazardous nature

Features: ɀ Spring door receptacle located at the bottom is mechanically interlocked with the circuit breaker operating mechanism for maximum safety. Plug and receptacle contacts cannot be made or broken under load. The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the ‘‘ON’’ position ɀ Quick installation and leveling is provided by the three-point mounting arrangement having one keyhole slot at top and two open slots at bottom ɀ Bodies have four 11⁄4⍯ taper tapped conduit hubs with integral bushings. Two are located at top and two directly below ɀ When installing, seals suitable for Class I, Group B hazardous areas must be located within 11⁄2⍯ of each conduit opening

Grounding: ɀ EPCB interlocked receptacles and matching plugs are provided with an extra grounding pole for attaching a grounding wire. In addition, direct connection is provided between plug and receptacle and the grounding pole. If a separate grounding wire is not installed in the enclosure, grounding is accomplished through the conduit system

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Dust-Ignitionproof Raintight Wet Locations

csm no.: 100

4P

Interchangeability of Plugs with Other Hazardous and Non-Hazardous Location Receptacles: ɀ Plugs listed for use with EPCB assemblies are standard Arktite APJ/NPJ plugs. Other standard APJ and CPH plugs of the same rating, style and number of poles may be used with EPCB receptacles as well as DR receptacles listed in Section 2P and DBR and EPC receptacles listed elsewhere in this section ɀ As a result, portable equipment suitable for the location and equipped with the proper plug can be used with AR/NR series receptacles for non-hazardous locations; EBBR, EPC and EPCB receptacles for Class I hazardous locations; DR and DBR receptacles for Class II hazardous locations

Standard Materials: ɀ Bodies, covers and receptacle housings – copper-free aluminum ɀ Operating handles – copper-free aluminum ɀ Operating shafts – stainless steel ɀ Interior parts – sheet steel ɀ Insulation – fiberglass-reinforced polyester ɀ Pressure contacts – brass ɀ Crimp/solder contacts – leaded red brass

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Stainless steel – natural ɀ Sheet steel – zinc electroplate with chromate finish ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate

Electrical Rating Ranges: ɀ Receptacle ratings: 30, 60 and 100 amperes ɀ Circuit breakers: 100 ampere frame size

Certifications and Compliances: ɀ NEC: Class I, Division 1 and 2, Groups B,C,D Class II; Division 1 and 2, Groups F,G Class III ɀ NEMA: 3,7BCD,9FG,12 ɀ ANSI/UL Standard: 1010 ɀ CEC: Class I, Division 1 and 2, Groups B,C,D Class II, Division 1 and 2, Group G Class III ɀ Encl.: 3,4

Options: The following special options are available by adding suffix to Cat. No.: Suffix to be Added to Encl. Cat. #

Description Special polarity. For use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available as follows: Receptacle interior rotated 221⁄2 degrees to right (viewed from face) and plug changed to match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . S4 Side bosses drilled and tapped same size as standard hubs . . . . . . . . . . . . . . . . . . . . . . . . . . S366 Back boss drilled and tapped same size as standard hubs . . . . . . . . . . . . . . . . . . . . . . . . . . . . S367

ɍɍ Pressure connectors are supplied as standard.

To specify crimp/solder type terminations add the suffix ‘‘T’’ to the catalog number. For example: APJ3365-T (Plug)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1059)) CH0 4 P - 1 9

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1059

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1060-1 Name: 4P-1060

DATE: JAN 19 2006

Time: 6:11:34 PM Operator: RB

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 and 2, Groups B,C,D Cl. II, Div. 1 and 2, Groups F,G Cl. III NEMA/EFC 3,7BCD,9FG,12 Explosionproof

EPCB Circuit Breakers and Enclosures with Interlocked Arktite® Receptacles

4P

COLOR: CMYK

APJ/NPJ Arktite Plugsɍɍ

Dust-Ignitionproof Raintight Wet Locations

100 Ampere Frame Size Thermal-Magnetic Circuit Breaker with Non-Interchangeable Thermal Trip and Non-Adjustable Magnetic Trip Circuit Breaker Receptacle with Spring Door Housing 30 amp. 2-wire, 3-pole, Style 2 30 amp. 3-wire, 4-pole, Style 2 60 amp. 2-wire, 3-pole, Style 2

Rating 2-pole, 600VAC or 250VDC 3-pole, 600VAC or 250VDC 2-pole, 600VAC or 250VDC

60 amp. 3-wire, 4-pole, Style 2

3-pole, 600VAC or 250VDC

100 amp. 2-wire, 3-pole, Style 2 100 amp. 3-wire, 4-pole, Style 2

2-pole, 600VAC or 250VDC 3-pole, 600VAC or 250VDC

Enclosure with Circuit Breaker Ckt. Hub Bkr. Size Amps Cutler-Hammer 20 EPCB43632-WT20HFD-2 30 EPCB43632-WT30HFD-2 40* EPCB43632-WT40HFD-2 11⁄4 50* EPCB43632-WT50HFD-2 20 EPCB43642-WT20HFD-3 30 EPCB43642-WT30HFD3 11⁄4 40* EPCB43642-WT40HFD-3 50* EPCB43642-WT50HFD-3 50 EPCB46632-WT50HFD-2 60* EPCB46632-WT60HFD-2 70* EPCB46632-WT70HFD-2 11⁄4 90* EPCB46632-WT90HFD-2 100* EPCB46632-WT100HFD-2 50 EPCB46642-WT50HFD-3 60* EPCB46642-WT60HFD-3 70* EPCB46642-WT70HFD-3 11⁄4 90* EPCB46642-WT90HFD-3 100* EPCB46642-WT100HFD-3 70 EPCB41632-WT70HFD-2 90 EPCB41632-WT90HFD-2 11⁄4 100 EPCB41632-WT100HFD-2

11⁄4

70† 90† 100†

General Electric EPCB43632-TT20TED-2 EPCB43632-TT30TED-2 EPCB43632-TT40TED-2 EPCB43632-TT50TED-2 EPCB43642-TT20TED-3 EPCB43642-TT30TED-3 EPCB43642-TT40TED-3 EPCB43642-TT50TED-3 EPCB46632-TT50TED-2 EPCB46632-TT60TED-2 EPCB46632-TT70TED-2 EPCB46632-TT90TED-2 EPCB46632-TT100TED-2 EPCB46642-TT50TED-3 EPCB46642-TT60TED-3 EPCB46642-TT70TED-3 EPCB46642-TT90TED-3 EPCB46642-TT100TED-3 EPCB41632-TT70TED-2 EPCB41632-TT90TED-2 EPCB41632-TT100TED-2

EPCB41642-WT70HFD-3 EPCB41642-WT90HFD-3 EPCB41642-WT100HFD-3

600VAC/250VDC with Cable Grip and Neoprene Bushing – Style 2 NPJ Plug Amps 30

60

100

Receptacle 30 Amp. 60 Amp. 100 Amp. Receptacle 30 Amp. 60 Amp. 100 Amp.

STIBOINFO((CRH:66008com:4P:1060)) CH0 4 P - 2 0

† For detailed information on circuit breaker selection see Section 6C. ɍɍ Pressure connectors are supplied as standard. To specify crimp/solder type terminators add the suffix ‘‘T’’ to the catalog number. For example: APJ3385-T (Plug)

APJ/NPJ Arktite Plugs

Dimensions

1060

receptacle rating for welding equipment applications only, as higher trip rating may not protect wiring.

EPCB41642-TT70TED-3 EPCB41642-TT90TED-3 EPCB41642-TT100TED-3

APJ Plug

APJ

* Circuit breaker trip rating may exceed

NPJ

US: 1-866-764-5454

a 261⁄4 263⁄4 271⁄2 g 139⁄16 139⁄16 139⁄16

b 115⁄16 115⁄16 115⁄16 h 415⁄16 57⁄16 63⁄16

Cable O.D. Range 0.60 to 1.20 0.55 to 0.70 0.70 to 0.85 0.75 to 1.45 0.75 to 1.07 1.07 to 1.35 1.00 to 1.70 0.93 to 1.21 1.21 to 1.50 c 113⁄4 113⁄4 113⁄4 j 413⁄16 513⁄16 65⁄8

2-wire, 3-pole Cat. # APJ3385 NPJ3383 NPJ3384 APJ6385 NPJ6384 NPJ6385 APJ10387 NPJ10386 NPJ10387

d 85⁄8 85⁄8 85⁄8 jj 7 613⁄16 73⁄4

Dim ‘‘j’’ and ‘‘jj’’ are exposed portion of plug when engaged with receptacle.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

e 5 5 5 k 243⁄4 243⁄4 243⁄4

3-wire, 4-pole Cat. # APJ3485 NPJ3483 NPJ3484 APJ6485 NPJ6484 NPJ6485 APJ10487 NPJ10486 NPJ10487 f 73⁄4 73⁄4 73⁄4 l 83⁄16 83⁄16 83⁄16

m 15⁄8 15⁄8 15⁄8

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1061-2 Name: 4P-1061

100: DATE: JAN 19 2006

Time: 6:11:35 PM Operator: RB

DBR Interlocked Arktite® Receptacles With Enclosed Circuit Breakers

COLOR: CMYK

Application:

Standard Materials:

DBR interlocked Arktite receptacles with enclosed circuit breakers and APJ/NPJ Arktite plugs are used: ɀ to supply power to portable electrical equipment such as motor-generator sets, compressors, heating and cooling units, conveyors, and similar equipment ɀ in locations where hazardous dusts are present, as in grain processing and handling plants, chemical plants and certain food processing industries ɀ indoors or outdoors in damp, wet or corrosive locations

ɀ Bodies, covers and operating handles – copper-free aluminum ɀ Operating shafts – stainless steel ɀ Receptacle housings and plug exteriors – copper-free aluminum ɀ Insulation: plugs and receptacles – fiberglass-reinforced polyester ɀ Pressure contacts – brass ɀ Crimp/solder contacts – leaded red brass

ɀ Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection. ɀ Enclosures are compact and rectangular in shape permitting close spacing. ɀ For maximum safety, the spring door receptacle at the bottom is mechanically interlocked with the circuit breaker operating mechanism. The circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open. ɀ Operating handles can be padlocked in either ‘‘ON’’ or ‘‘OFF’’ positions. Breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the ‘‘ON’’ position. ɀ Enclosure is provided with a drilled and tapped conduit opening at top center, equipped with a threaded-in bushing. The size furnished is 11⁄2⍯, and removing the bushing permits the use of a 2⍯ conduit.

Interchangeability of Plugs with Other Hazardous and Non-Hazardous Location Receptacles: ɀ Plugs listed for use with DBR assemblies are standard Arktite APJ/NPJ plugs. Other standard APJ/NPJ and CPH plugs of the same rating, style and number of poles may be used with DBR receptacles, as well as with DR receptacles listed in Section 2P and with EBBR, EPC and EPCB receptacles listed in Section 4P. ɀ As a result, portable equipment suitable for the locations and equipped with the proper plug can be used with AR receptacles for non-hazardous locations, with EBBR, EPC and EPCB receptacles for Class I hazardous locations, and with DR and DBR interlocked receptacles for Class II hazardous locations.

Standard Finishes: ɀ Copper-free aluminum – plug exterior, enclosure and receptacle housing – natural ɀ Stainless steel – natural ɀ Brass – natural ɀ Fiberglass-reinforced polyester – natural (red) ɀ Leaded red brass – electro-tin-plate

Options: The following special options are available by adding suffix to Cat. No. Suffix to be Added to Description Cat. # Special polarity – for use where two or more receptacles of the same ampere rating, style and number of poles are to be installed in the same area for use on different voltages. Available as follows: ɀ Receptacle interior rotated 221⁄2 degrees clockwise when viewed from receptacle face and plug changed to match . . . . . . . . . . . . . . . . . . . . . S4 Breather (drain furnished as standard) . . . . . . . . . . . . . . . . . . . . . . . . . . . S219 Conduit arrangements other than standard can be supplied . Details on request

CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F locations that contain electrically conductive dusts. ɍɍ Pressure connectors are standard. Crimp/solder type terminators are optionally available for 3 and 4-pole, 30, 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: AP3375-T (Plug)

Dimensions:

Certifications and Compliances: ɀ NEC: Class II, Division 1 and 2, Groups F,G Class III ɀ NEMA/EEMAC: 3, 9FG, 12 ɀ UL Standard: 698, 1010 ɀ CEC: Class II, Division 1 and 2, Group G Class III ɀ Encl.: 3,5

Electrical Rating Ranges: ɀ Receptacle ratings: 30, 60 and 100 amperes ɀ Circuit breakers – 100 ampere frame size Amps a b bb 61⁄2 7 30 213⁄4 81⁄2 613⁄16 60 223⁄4 100 231⁄2 101⁄8 73⁄4 Dim. ‘‘b’’ and ‘‘bb’’ are exposed portion of plug when engaged with receptacle.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:4P:1061))

csm no.: 100

4P

APJ

CH0 4 P - 2 1

Typedriver Name: TS name

Cl. II, Div. 1 and 2, Groups F,G Cl. III NEMA/EEMAC 3,9FG,12 Dust-Ignitionproof Raintight

APJ/NPJ Arktite Plugs ɍ ɍ

Features:

TCP: 15001

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

NPJ

1061

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1062-2 Name: 4P-1062

4P

DATE: JAN 19 2006

Time: 6:11:36 PM Operator: RB

DBR Interlocked Arktite® Receptacles With Enclosed Circuit Breakers

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. II, Div. 1 and 2, Groups F,G Cl. III NEMA/EEMAC 3,9FG,12 Dust-Ignitionproof Raintight

100 Ampere Frame Size with Non-Interchangeable Thermal Trip and Non-Adjustable Magnetic Trip Enclosure Ckt. Hub Bkr. Size Amps

Receptacle With Spring Door Housing†

Circuit Breaker Rating

30 amp., 3-wire, 3-pole, Style 1 30 amp., 2-wire, 3-pole, Style 2 30 amp., 3-wire, 4-pole, Style 2 60 amp., 3-wire, 3-pole, Style 1

3-pole 600VAC

11⁄2

2-pole 600VAC or 250VDC 3-pole 600VAC

11⁄2

3-pole 600VAC

11⁄2

60 amp., 2-wire, 3-pole, Style 2

2-pole 600VAC or 250VDC

11⁄2

60 amp., 3-wire, 4-pole, Style 2

3-pole 600VAC

11⁄2

100 amp., 3-wire, 3-pole, Style 1 100 amp., 2-wire, 3-pole, Style 2 100 amp., 3-wire, 4-pole, Style 2

3-pole 600VAC

11⁄2

2-pole 600VAC or 250VDC 3-pole 600VAC

11⁄2

11⁄2

11⁄2

20 30 40 50 20 30 40 50 20 30 40 50 50 60 70 90 100 50 60 70 90 100 50 60 70 90 100 60 70 90 100 60 70 90 100 60 70 90 100

Without Circuit Breaker Cat. # DBR53731

DBR53732

DBR53742

DBR56731

DBR56732

DBR56742

DBR51731

DBR51732

DBR51742

With Circuit Breaker Cat. # Cutler-Hammer ‘‘FDB’’ DBR53731-WT20-3 DBR53731-WT30-3 DBR53731-WT40-3* DBR53731-WT50-3* DBR53732-WT20-2 DBR53732-WT30-2 DBR53732-WT40-2* DBR53732-WT50-2* DBR53742-WT20-3 DBR53742-WT30-3 DBR53742-WT40-3* DBR53742-WT50-3* DBR56731-WT50-3 DBR56731-WT60-3 DBR56731-WT70-3* DBR56731-WT90-3* DBR56731-WT100-3* DBR56732-WT50-2 DBR56732-WT60-2 DBR56732-WT70-2* DBR56732-WT90-2* DBR56732-WT100-2* DBR56742-WT50-3 DBR56742-WT60-3 DBR56742-WT70-3* DBR56742-WT90-3* DBR56742-WT100-3* DBR51731-WT60-3 DBR51731-WT70-3 DBR51731-WT90-3 DBR51731-WT100-3 DBR51732-WT60-2 DBR51732-WT70-2 DBR51732-WT90-2 DBR51732-WT100-2 DBR51742-WT60-3 DBR51742-WT70-3 DBR51742-WT90-3 DBR51742-WT100-3

* Circuit breaker trip rating may exceed receptacled rating for welding equipment applications only, as higher trip rating may not protect wiring. ɍɍ Pressure connectors are standard. Crimp/solder type terminators are optionally available for 3 and 4-pole 30, 60 and 100 ampere. For details, see table on page 969. To specify, add the suffix ‘‘T’’ to the catalog number. For example: APJ3375-T (Plug) † Style 1 – Grounded through shell. Style 2 – Grounded through extra pole and shell. For a detailed description of these grounding methods, see page 967. ‡ For circuit breaker Cat. No. refer to Section 6C, Table 9, List FDB. For detailed information on circuit breaker selection, see Section 6C.

APJ/NPJ Arktite Plugs 600VAC/250VDC with Cable Grip and Neoprene Bushing Amps 30

60

APJ Plug

1062

STIBOINFO((CRH:66008com:4P:1062)) CH0 4 P - 2 2

100

NPJ Plug

US: 1-866-764-5454

CAN: 1-800-265-0502

Cable O.D. Range 0.60 to 1.20 0.55 to 0.70 0.70 to 0.85 0.75 to 1.45 0.75 to 1.07 1.07 to 1.35 1.00 to 1.70 0.93 to 1.21 1.21 to 1.50

Style 1†

Style 2†

3-wire, 3-pole Cat. # APJ3375

2-wire, 3-pole Cat. # APJ3385 NPJ3383 NPJ3384 APJ6385 NPJ6384 NPJ6385 APJ10387 NPJ10386 NPJ10387

APJ6375

APJ10377

Copyright© 2006 Cooper Crouse-Hinds

3-wire, 4-pole Cat. # APJ3485 NPJ3483 NPJ3484 APJ6485 NPJ6484 NPJ6485 APJ10487 NPJ10486 NPJ10487

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1063-2 Name: 5P-1063

100: DATE: JAN 19 2006

Time: 6:11:37 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

IEC 309 Plugs, Receptacles, Interlocks Non-Hazardous & Hazardous

csm no.: 100

5P

Description

Page No.

Non-Hazardous Plugs, Receptacles, Interlocks Applications, Technical Data Ordering Information

1064-1067 1068, 1069

Hazardous Plugs, Interlocks Applications, Technical Data Ordering Information

Back Boxes, Accessories, Tech Data Angled Back Box Adapters Adapter Plates

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1063)) CH0 0 0 0 5 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1070, 1071 1072, 1073 1074, 1075 1076 1077

1063

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1064-2 Name: 5P-1064

DATE: JAN 19 2006

Time: 6:12:41 PM Operator: JB COLOR: CMYK

IEC 309 Pin & Sleeve Plugs & Receptacles 20, 30, 60 & 100A - Series 2 16, 32, 63 & 125A - Series 1

5P

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4X IP 66 Watertight

Applications

Standard Materials

ɀ wet location & hosedown areas ɀ damp or corrosice locations ɀ food processing, wastewater, shipyard, marina, restaurant, construction site, HVAC and convention centers

ɀ receptacle housing: RIP, nylon, VX ɀ contact carrier: fiber–reinforced thermoplastic, VX ɀ pins & sleeves: brass ɀ multi–lam bands: copper beryllium ɀ assembly screws: stainless steel ɀ plug: type 6⁄6 nylon, VX ɀ receptacle hinge pin: stainless steel ɀ gaskets: silicon

Features ɀ voltage configured, color coded ɀ watertight ɀ impact and corrosion resistant ɀ receptacles mount to Cooper Crouse-Hinds back boxes ɀ innovative finger lock keeps cord grip secured ɀ positive grommet seal system at cord entry ɀ funneled wire pockets ɀ lockout/tagout ɀ high grade brass contacts ɀ VX insulating material ɀ multi-lam sleeve bands

Certifications & Compliances ɀ listed UL 498, 1682 & 1686 ɀ CSA C22.2 no. 182.1 ɀ IEC 309-1 & 309-2 ɀ NEMA 4X ɀ IEC IP66

Making a connection is easy A clock face is used to represent the grounding contact position for all female connectors and receptacles. With the keyway at the bottom, the female grounding contact will appear to one of the twelve hour positions. To identify the system voltage, identify the housing color and hour location of the connector or receptacle grounding contact.

Ordering is easy

We’ve made our catalog number ordering system as easy to use as our products! Simply follow the six-part ⍯code⍯:

CH Prefix CH = Cooper CrouseHinds

1064

STIBOINFO((CRH:66008com:5P:1064))

4

20

1st digit

2nd-4th digit

3 = 3 pole 4 = 4 pole 5 = 5 pole

16 = 16 Amp 20 = 20 Amp 30 = 30 Amp 32 = 32 Amp 60 = 60 Amp 63 = 63 Amp 100 = 100 Amp 125 = 125 Amp

US: 1-866-764-5454

R

1st letter P= C= R= B= MI =

CAN: 1-800-265-0502

Plug Connector Receptacle Inlet Mechanical Interlock

7

Last digit Clock position of female grounding contact

Copyright© 2006 Cooper Crouse-Hinds

W

Last letter W = Watertight

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1065-2 Name: 5P-1065

100: DATE: JAN 19 2006

Time: 6:12:42 PM Operator: JB COLOR: CMYK

IEC 309 Pin & Sleeve Plugs & Receptacles 20, 30, 60 & 100A - Series 2 16, 32, 63 & 125A - Series 1

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4X IP 66 Watertight

5P

Plug

Locking finger seats into web pockets when cord grip is tightened down, securing back cap in place even under heavy usage and vibration.

Receptacle Color–coded cap accurately identifies mating plug of correct voltage.

Nickle–plated brass contacts offer long–life corrosion protection. Compression lugs provide reliable mechanical wire termination.

Funneled wiring pockets for ease of inserting stranded wire. Deep pocket marked X, Y, Z and Keep bare conductors safely confined and isolated from adjacent wires.

Cooper Crouse-Hinds standard mounting footprint fits all existing Cooper Crouse-Hinds back boxes.

Impact–resistant thermoplastic contact carrier provides superior electrical insulation and V flammability rating.

Brass contacts with self cleaning, feild–proven multi– lam pressure bands for smooth pin insertion, low heat rise and quality electrical performance. Lockout/tagout hole for OFF position. Watertight cap meets NEMA 4X, IP66 hosedown standards. Funneled wire termination pockets have all screw heads on same side for easy conductor insertion and quick wiring.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1065))

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1065

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1066-2 Name: 5P-1066

5P

100: DATE: JAN 19 2006

Time: 6:12:44 PM Operator: JB COLOR: CMYK

IEC 309 Pin & Sleeve Mechanical Interlocks Nonhazardous

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4X IP 66 Watertight

20 & 30A - North American Ratings Series 2 16 & 32A - International Ratings Series 1 Applications

Standard Materials

ɀ to supply power to portable or fixed electrical equipment such as welders, motor-generator sets, compressors, conveyors, portable tools, lighting systems and similar equipment ɀ in damp or corrosive locations ɀ in wet locations ɀ in hosedown areas ɀ for short-circuit protection when ordered with optional fusing

ɀ enclosure: fiber-reinforced polyester ɀ external hardware: stainless steel ɀ contacts: brass ɀ contact carrier: fiber-reinforced thermoplastic

Horsepower ratings

Features

Amps 20A

ɀ Mechanically interlocked, dead-front receptacle – plug cannot be engaged or disengaged under load ɀ Enclosure has continuous form-in-place gasket ɀ meets OSHA’s lockout/tagout requirements – can be padlocked in ‘‘OFF’’ position ɀ industrial switch is horsepower-rated for motor load applications ɀ available with optional fusing for short-circuit protection

30A 60A 100A *

Description Unfused Unfused Fused* Unfused Fused* Unfused

See bulletin #4671

Certifications & Compliances ɀ UL Standards 508, 1682 ɀ CSA Standard C22.2 Nos. 14, 182.1 ɀ Enclosure type: 3, 4X, 12 ɀ IP66

1066

STIBOINFO((CRH:66008com:5P:1066))

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Three Phase 250VAC 480VAC 600VAC 7.5 15 20 10 20 25 10 20 25 20 40 40 20 40 50 25 50 40

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1067-1 Name: 5P-1067

100: DATE: JAN 19 2006

Time: 6:12:45 PM Operator: RB

COLOR: CMYK

IEC 309 Pin & Sleeve Mechanical Interlocks Nonhazardous

TCP: 15001

Typedriver Name: TS name

NEMA 4X IP 66 Watertight

csm no.: 100

5P

20 & 30A - North America Ratings Series 2 16 & 32A - International Ratings Series 1 OSHA lockout/tagout handle

Fiber–reinforced polyester housing provides superior corrosion and impact resistance. Compact design fits in the web of an I–beam – smallest in the industry.

Tongue and groove IP66 watertight sealing system. Continuous raised rib around perimeter of base seats in channel in cover. Channel has a seamless, one–piece gasket that stays in place when cover is removed.

Color–coded receptacle cover with lockout/tagout hole for off position.

Molded in place mounting feet Myers® NPT or metric threaded whubs for IEC connectors.

Easy to wire. Cover removes along an innovative break line that permits full access to internal switch terminations.

Thick, sturdy walls won′t warp from hot and cold water washdown. Maintains gasket seal between cover and box.

Raised mounting pads allow firm mounting to uneven surfaces. Provides water channel between wall and enclosure.

Options ɀ Auxiliary contacts for PLC or pilot light applications–add suffix [S483]

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1067))

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1067

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1068-2 Name: 5P-1068

100: DATE: JAN 19 2006

Time: 6:12:46 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

NEMA 4X IP 66 Watertight

IEC 309 Pin & Sleeve Mechanical Interlocks Nonhazardous

5P

20 & 30A - North America Ratings Series 2 16 & 32A - International Ratings Series 1 Ordering Information: Watertight Devices

Amps 16A

20A

30A

32A

Wires CONFIFURATION and Poles Recept./Conn. Plug/Inlet

Voltage

RECEPTACLE

PLUG

CONNECTOR

INLET

INTERLOCK UNFUSED

2W3P

110-120

CH316R4W

CH316P4W

CH316C4W

CH316B4W

CH316MI4W*

2W3P

220-240

CH316R6W

CH316P6W

CH316C6W

CH316B6W

CH316MI6W*

3W4P

380-415

CH416R6W

CH416P6W

CH416C6W

CH416B6W

CH416MI6W

4W5P

220\380 240\415

CH516R6W

CH516P6W

CH516C6W

N/A

CH516MI6W*

2W3P

125

CH320R4W

CH320P4W

CH320C4W

CH320B4W

CH320MI4W*

2W3P

250

CH320R6W

CH320P6W

CH320C6W

CH320B6W

CH320MI6W*

2W3P

480

CH320R7W

CH320P7W

CH320C7W

CH320B7W

CH320MI7W*

3W4P

125\250

CH420R12W

CH420P12W

CH420C12W

CH420B12W

CH420MI12W

3W4P

3X250

CH420R9W

CH420P9W

CH420C9W

CH420B9W

CH420MI9W

3W4P

3X480

CH420R7W

CH420P7W

CH420C7W

CH420B7W

CH420MI7W

3W4P

3X600

CH420R5W

CH420P5W

CH420C5W

CH420B5W

CH420MI5W

4W5P

3XY120\208

CH520R9W

CH520P9W

CH520C9W

N/A

CH520MI9W*

4W5P

3XY277\480

CH520R7W

CH520P7W

CH520C7W

N/A

CH520MI7W*

4W5P

3XY347\600

CH520R5W

CH520P5W

CH520C5W

N/A

CH520MI5W*

2W3P

125

CH330R4W

CH330P4W

CH330C4W

CH330B4W

CH330MI4W

2W3P

250

CH330R6W

CH330P6W

CH330C6W

CH330B6W

CH330MI6W

2W3P

480

CH330R7W

CH330P7W

CH330C7W

CH330B7W

CH330MI7W

3W4P

3X250

CH430R9W

CH430P9W

CH430C9W

CH430B9W

CH430MI9W

3W4P

3X480

CH430R7W

CH430P7W

CH430C7W

CH430B7W

CH430MI7W

3W4P

3X600

CH430R5W

CH430P5W

CH430C5W

CH430B5W

CH430MI5W

4W5P

3XY120\208

CH530R9W

CH530P9W

CH530C9W

N/A

CH530MI9W

4W5P

3XY277\480

CH530R7W

CH530P7W

CH530C7W

N/A

CH530MI7W

4W5P

3XY347\600

CH530R5W

CH530P5W

CH530C5W

N/A

CH530MI6W

2W3P

110-120

CH332R4W

CH332P4W

CH332C4W

CH332B4W

CH332MI4W

2W3P

220-240

CH332R6W

CH332P6W

CH332C6W

CH332B6W

CH332MI6W

3W4P

380-415

CH432R6W

CH432P6W

CH432C6W

CH432B6W

CH432MI6W

4W5P

220\380

CH532R6W

CH532P6W

CH532C6W

CH532MI6W

* Alternate Switch Design. Does not have a switch handle. Switch is activated by inserting plug: rotating plug to turn switch ‘ON’.

1068

STIBOINFO((CRH:66008com:5P:1068))

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1069-1 Name: 5P-1069

100: DATE: JAN 19 2006

Time: 6:12:52 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

NEMA 4X IP 66 Watertight

IEC 309 Pin & Sleeve Mechanical Interlocks Nonhazardous

csm no.: 100

5P

20 & 30A - North America Ratings Series 2 16 & 32A - International Ratings Series 1 Ordering Information: Watertight Devices

Amps 60A

63A

100A

125A

Wires CONFIGURATION and Poles Recept./Conn. Plug/Inlet

Voltage

RECEPTACLE

PLUG

CONNECTOR

INLET

INTERLOCK UNFUSED

2W3P

125

CH360R4W

CH360P4W

CH360C4W

CH360B4W

CH360MI4W

2W3P

250

CH360R6W

CH360P6W

CH360C6W

CH360B6W

CH360MI6W

2W3P

480

CH360R7W

CH360P7W

CH360C7W

CH360B7W

CH360MI7W

3W4P

125\250

CH460R12W

CH460P12W

CH460C12W

CH460B12W

CH460MI12W

3W4P

3X250

CH460R9W

CH460P9W

CH460C9W

CH460B9W

CH460MI9W

3W4P

3X480

CH460R7W

CH460P7W

CH460C7W

CH460B7W

CH460MI7W

3W4P

3X600

CH460R5W

CH460P5W

CH460C5W

CH460B5W

CH460MI5W

4W5P

3XY120\208

CH560R9W

CH560P9W

CH560C9W

CH560B9W

CH560MI9W

4W5P

3XY277\480

CH560R7W

CH560P7W

CH560C7W

CH560B7W

CH560MI7W

4W5P

3XY347\600

CH560R5W

CH560P5W

CH560C5W

CH560B5W

CH560MI5W

2W3P

220-240

CH363R6W

CH363P6W

CH363C6W

CH363B6W

CH363MI6W

3W4P

380-415

CH463R6W

CH463P6W

CH463C6W

CH463B6W

CH463MI6W

4W5P

220\380 240\415

CH563R6W

CH563P6W

CH563C6W

CH563B6W

CH563MI6W

2W3P

125

CH3100R4W

CH3100P4W

CH3100C4W

CH3100B4W

CH3100MI4W

2W3P

250

CH3100R6W

CH3100P6W

CH3100C6W

CH3100B6W

CH3100MI6W

2W3P

480

CH3100R7W

CH3100P7W

CH3100C7W

CH3100B7W

CH3100MI7W

3W4P

125\250

CH4100R12W

CH4100P12W CH4100C12W CH4100B12W CH4100MI12W

3W4P

3X250

CH4100R9W

CH4100P9W

CH4100C9W

CH4100B9W

CH4100MI9W

3W4P

3X480

CH4100R7W

CH4100P7W

CH4100C7W

CH4100B7W

CH4100MI7W

3W4P

3X600

CH4100R5W

CH4100P5W

CH4100C5W

CH4100B5W

CH4100MI5W

4W5P

3XY120\208

CH5100R9W

CH5100P9W

CH5100C9W

CH5100B9W

CH5100MI9W

4W5P

3XY277\480

CH5100R7W

CH5100P7W

CH5100C7W

CH5100B7W

CH5100MI7W

4W5P

3XY347\600

CH5100R5W

CH5100P5W

CH5100C5W

CH5100B5W

CH5100MI5W

2W3P

220-240

CH3125R6W

CH3125P6W

CH3125C6W

CH3125B6W

CH3125MI6W

3W4P

380-415

CH4125R6W

CH4125P6W

CH4125C6W

CH4125B6W

CH4125MI6W

4W5P

220\380 240\415

CH5125R6W

CH5125P6W

CH5125C6W

CH5125B6W

CH5125MI6W

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1069))

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1069

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1070-1 Name: 5P-1070

100: DATE: JAN 19 2006

Time: 6:12:56 PM Operator: RB

Hazardous Area Interlocks & Plugs ‘‘GHG’’ Series

5P

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Class I, Zone 1 & 2, Div. 2, NEMA 4X, IP66

Color–coded receptacle cover and plug.

Rainshedding watertight profile.

Molded in place mounting feet.

Dual bottom entries in NPT or metric thread for cable or conduit. Fiber–reinforced nylon type 12 impact – and corrosion–resistant enclosure and plug.

Locking finger seats into web pockets securing back cap in place even under heavy usage and vibration.

HEAVY DUTY STRAIN RELIEF Offering superior pullout protection and significantly reducing the occurrance of seal failure, our external stain relief system absorbs all tensile and torsional forces. In addition, an extremely long and dependable inside seal provides added protection.

1070

STIBOINFO((CRH:66008com:5P:1070))

Nickel–plated brass contacts offer long life–corrosion protection. Compression lugs provide reliable mechanical wire termination.

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1071-1 Name: 5P-1071

100: DATE: JAN 19 2006

Time: 6:12:57 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Class I, Zone 1 & 2, Div. 2, NEMA 4X, IP66

IEC 309 Hazardous Area Plugs & Interlocks

csm no.: 100

5P

Easy to wire. Cover removes along an innovative break line that permits full access to internal switch terminations.

Brass contacts with field-proven, self-cleaning multi-lam pressure bands for smooth plug insertion, low heat rise and uniform electrical contact. Factory sealed switch provides Zone 1 & 2, Div. 2 explosion protection. Receptacle is dead– front until plug is fully engaged and rotated to activate switch. Plug cannot be removed under load. Switch is horsepower, and AIC–rated.

Applications IEC 309 explosion protected devices are used: ɀ to supply power to portable or fixed electrical equipment ɀ where hazardous gases may be present ɀ in damp or wet locations ɀ where impact and corrosion resistance are required ɀ where compact equipment is required in tight spaces

Standard Materials

Features

Certifications

ɀ mechanicaly interlocked plug and receptacle– plug cannot be engaged or disengaged under load ɀ simple ‘‘insert plug and twist’’ design to activate internal switch ɀ self cleaning multi–lam contacts provide reliable power connection ɀ compact size, easy to handle and install ɀ OSHA lockout/tagout ɀ dual bottom entry zone 1 Myers® hubs ɀ full wiring access, saves time and money ɀ VØ rated materials

ɀ AEx de IIc T6 ɀ Class I, Zone I, Div. 2, Groups A, B, C & D ɀ EEx ed IIc T6 ɀ (EX LOGO) II 2G/D ɀ UL, cUL* ɀ PTB 99 ATEX 1039 ɀ IP66, NEMA 4X ɀ CE ɀ VDE

ɀ enclosure: type 12 nylon ɀ plug body: fiber–reinforced nylon ɀ hardware: stainless steel ɀ contacts: brass

* 20A, 30A, 60A, 100A Pin Configuration to IEC 309-1/2 Series 2 - U.L. Listed 16A, 32A, 63A, 125A Pin Configuration to IEC 309-1/2 Series 1 - Not U.L. Listed

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1071))

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1071

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1072-2 Name: 5P-1072

DATE: JAN 19 2006

Time: 6:12:59 PM Operator: JB COLOR: CMYK

IEC 309 Hazardous Area Plugs & Interlocks

5P

TCP: 15001

Typedriver Name: TS name csm no.: 100

Class I, Zone 1 & 2, Div. 2, NEMA 4X, IP66

Ordering Information:

Amps 16A

Cable Myers Gland Hub

CONFIFURATION Recept./Conn.

Plug/Inlet

Voltage

INTERLOCK RECEPTACLE

PLUG

M20

2W3P

110-120

GHG 511 4304 R3001

GHG 511 7304 R0001

M20

2W3P

220-240

GHG 511 4306 R3001

GHG511 7306 R0001

M25

3W4P

220-240

GHG 511 4409 R3001

GHG 511 7409 R0001

M25

3W4P

380.415

GHG 511 4406 R3001

GHG 511 7406 R0001

M25

3W4P

500

GHG 511 4407 R3001

GHG 511 7407 R0001

M25

3W4P

690

GHG 511 4405 R3001

GHG 511 7405 R0001

W25

4W5P

380-415

GHG 511 4506 R3001

GHG 511 7506 R0001

1⁄2

2W3P

125

GHG 511 4304 L3001

GHG 511 7304 L0001

1⁄2

2W3P

250

GHG 511 4306 L3001

GHG 511 7306 L0001

3⁄4

3W4P

3X250

GHG 511 4409 L3001

GHG 511 7409 L0001

3⁄4

3W4P

3X480

GHG 511 4407 L3001

GHG 511 7407 L0001

3⁄4

3W4P

3X600

GHG 511 4405 L3001

GHG 511 7405 L0001

1

3W4P

3X250

GHG 512 4409 L3001

GHG 512 7409 L0001

1

3W4P

3X480

GHG 512 4407 L3001

GHG 512 7407 L0001

1

3W4P

3X600

GHG 512 4405 L3001

GHG 512 7405 L0001

M32

3W4P

220-240

GHG 512 4409 R3001

GHG 512 7409 R0001

M32

3W4P

380-415

GHG 512 4406 R3001

GHG 512 7406 R0001

M32

3W4P

500

GHG 512 4407 R3001

GHG 512 7407 R0001

M32

3W4P

690

GHG 512 4405 R3001

GHG 512 7405 R0001

20A

30A

32A

Wires and Poles

M32 60A

1072

STIBOINFO((CRH:66008com:5P:1072))

4W5P

380-415

GHG 512 4506 R3001

GHG 512 7506 R0001

1

1⁄4

3W4P

3X250

GHG 514 4409 L3001

GHG 514 7409 L0001

1

1⁄4

3W4P

3X480

GHG 514 4407 L3001

GHG 514 7407 L0001

1

1⁄4

3W4P

3X600

GHG 514 4405 L3001

GHG 514 7405 L0001

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1073-1 Name: 5P-1073

DATE: JAN 19 2006

Time: 6:13:02 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Class I, Zone 1 & 2, Div. 2, NEMA 4X, IP66

IEC 309 Hazardous Area Plugs & Interlocks

csm no.: 100

5P

Ordering Information:

Amps 63A

Cable Myers Gland Hub

CONFIFURATION Recept./Conn.

Plug/Inlet

Voltage

M40

3W4P

220-240

GHG 514 4409 R3001

GHG 514 7409 R0001

M40

3W4P

380-415

GHG 514 4506 R3001

GHG 514 7406 R0001

M40

3W4P

500

GHG 514 4407 R3001

GHG 514 7407 R0001

M40

3W4P

690

GHG 514 4405 R3001

GHG 514 7405 R0001

M40

4W5P

380-415

GHG 514 4506 R3001

GHG 514 7506 R0001

1

1⁄2

3W4P

125\250

GHG 515 4412 L3001

GHG 515 7412 L0001

1

1⁄2

3W4P

3X250

GHG 515 4409 L3001

GHG 515 7409 L0001

1

1⁄2

3W4P

3X480

GHG 515 4407 L3001

GHG 515 7407 L0001

1

1⁄2

3W4P

3X600

GHG 515 4405 L3001

GHG 515 7405 L0001

1

1⁄2

4W5P

690

GHG 515 4506 L3001

GHG 515 7506 L0001

M63

3W4P

220-240

GHG 515 4409 R3001

GHG 515 7409 R0001

M63

3W4P

380-415

GHG 515 4406 R3001

GHG 515 7406 R0001

M63

3W4P

500

GHG 515 4407 R3001

GHG 515 7407 R0001

M63

3W4P

690

GHG 515 4405 R3001

GHG 515 7405 R0001

M63

4W5P

380-415

GHG 515 4506 R3001

GHG 515 7506 R0001

100A

125A

Wires and Poles

Dimensional Data (inches) B

20\16A 3P 4\5P 3.5 4.3

X T Y L H

3.15 4.8 4.53 6.1 8.8

A B CORD DIA. RANGE (in.)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1073))

CAN: 1-800-265-0502

3.94 5.8 5.31 6.9 9.3

20\16A 3P 4P 5P 6.7 7.4 7.4 2.8 3.0 3.3

30\32A 4\5P 4.7 4.33 6.6 6.70 8.1 11.5

30\32A 4\5P 9.8 3.9

60\63A 100\125A 4\5P 7.9 8.9 7.09 8.9 10.87 14.6 18.7

8.10 10.0 11.90 13.3 21.1

60\63A 100\125A 4\5P 10.7 12.32 4.3 5.16

.515-.827 .515-1.102 .630-1.378 .827-2.28

Copyright© 2006 Cooper Crouse-Hinds

1073

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1074-1 Name: 5P-1074

5P

DATE: JAN 19 2006

Time: 6:13:05 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

IEC 309 Pin & Sleeve Devices Dimensional Data (inches)

Plug Dimensions

Amps

A

20\16A 30\32a 60\63a 100\125A

7.37 7.37 10.71 12.32

B

3 Pole

CORD RANGE 4 Pole 5 Pole

3.00 .315-.748 .315-748 .472-827 3.00 .314-.748 .315-.748 .472-.827 4.33 .630-1.378 .630-1.378 .827-1.378 5.16 .827-1.89 .827-2.28 1.22-2.28

Receptacle Dimensions

Connector Dimensions

Amps

A

B

C

D

E

20\16A 30\32A 60\63A 100\125A

2.95 3.35 4.57 4.81

4.37 4.92 6.18 6.56

3.31 3.74 4.61 4.80

3.38 3.38 4.13 5.12

3.38 3.38 4.13 5.32

Amps

A

20\16A 30\32A 60\63A 100\125A

8.58 10.40 12.52 13.40

Amps

A

B

3 Pole

F

MTC. DIMS.

DIA.

X

Y

.236 .236 .236 .250

2.74 2.74 3.50 4.09

2.74 2.74 3.50 4.09

CORD RANGE 4 Pole 5 Pole

3.38 .315-.748 .315-827 .472-827 3.82 .315-.748 .315-.827 .472-.827 4.61 .630-1.378 .630-1.378 .827-1.378 5.32 .827-1.89 .827-2.28 1.22-.2.28

Interlock Dimensions

B

*20\16A 8.8 6.7 20\16A 9.3 6.9 30\32A 11.2 8.07 60\63A 18.7 12.3 100\125A 21.1 13.3 *3 Pole Only

20, 30 60, 100A

C

X

Y

3.5 4.3 4.7 7.9 8,9

3.7 3.9 4.3 7.1 8,1

4.5 5.3 6.7 10.9 11.9

HUB

1\2 3\4 1 11\4 11\2

16, 32, 63, 125A CABLE GLAND

M20 M25 M32 M40 M63

Inlet Dimensions

1074

STIBOINFO((CRH:66008com:5P:1074))

US: 1-866-764-5454

CAN: 1-800-265-0502

Amps

A

B

C

D

20\16A 30\32A 60$63A 100\125A

3.27 4.26 5.44 5.48

3.02 3.75 4.34 5.20

3.38 3.38 4.13 5.12

3.38 3.38 4.13 5.32

Copyright© 2006 Cooper Crouse-Hinds

F

MTC. DIMS.

DIA.

X

Y

.236 .236 .236 0.25

2.74 2.74 3.50 4.09

2.74 2.74 3.50 4.09

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1075-1 Name: 5P-1075

DATE: JAN 19 2006

Time: 6:13:06 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

IEC 309 Pin & Sleeve Devices Accessories

5P

Back Box Dimensions

16, 20, 30, & 32A Cast ALUMINUM

Cat. No.

HUB

A

B

Cat. No.

HUB

HUB CONFIG.

G

ARE13 ARE23 ARE33

1⁄2

1.84 1.84 1.97

.69 .81 .94

ARRH13 ARRH23 ARRH33 ARRC13 ARRC23 ARRD33

1⁄2

Dead End Dead End Dead End Feed Thru Feed Thru Feed Thru

.69 .81 .94 .69 .81 .94

*

3⁄4

1

Footprint: 2.74 x 2.74

60A & 63A Cast Aluminum

*

3⁄4

1 1⁄2 3⁄4

1

Cat. No.

HUB

A

B

ARE36 ARE46 ARE56

1 1 1⁄4 1 1⁄2

2.56 2.62 2.69

.69 1.19 1.31

Footprint: 5.4 x 2.74

20/16A

30/32A

60/63A

100/125A

3 pole 4 pole 5 pole 3 pole 4 pole 5 pole 3 pole 4 pole 5 pole 3 pole 4 pole 5 pole

Cat. No. CHBB1 ‡

*

Footprint: 2.74 x 2.74 (Not U.L. Listed)

Aluminum Fits ARRH and ARRC 30A Angle Adaptor Cast

Cat. No.

A

B

AR30

3.38

4.12

Footprint: 4.09 x 4.09

Plug Closure Cap

Enclosure Myers Hub

Enclosure Cable Gland

Enclosure Closure Plug

CHCC320 CHCC420 CHCC520

STM1 STM2

CHCG20 CHCG25

CHCP20 CHCP25

STM3

CHCG40

CHCG40

CHCC60

STM4

CHCG50

CHCP50

CHCC100

STM5

CHCG63

CHCP63

CHCC3430 CHCC530

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1075))

Cat. No. CHBB2

Footprint: 2.74 x 2.74

100A & 125A Cast Aluminum



csm no.: 100

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1075

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1076-6 Name: 5P-1076

5P

DATE: JAN 19 2006

Time: 6:13:08 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Angled Back Box Adapters For 20, 30, 60 & 100 Amp IEC 309 Receptacles and Inlets

Cooper Crouse-Hinds Angled Back Box Adapters install IEC 309 receptacles or inlets to existing back boxes at a 15° angle, eliminating plug cord stress and maximizing wiring capacity. Designed with a square footprint, the angled back box adapter allows the conduit openings to be positioned vertically or horizontally.

New Angled Adapters install directly onto existing Cooper Crouse-Hinds Back Boxes!

FEATURES:

ɀ Square footprint on adapter allows back box conduit openings to be positioned vertically or horizontally. ɀ 15° angle eliminates cord stress on attached plug. ɀ Heavy-duty cast aluminum back boxes are ideal for abusive environments. ɀ Epoxy powder coat finish available for additional corrosion resistance. ɀ Stainless steel hardware. ɀ Quick and easy to install. ɀ Neoprene gasket provided between adapter and back box for additional weather resistance

20/30 Amp

60 Amp

ORDERING INFORMATION: Rating of Receptacle or Inlet

Angled Adapter Catalog Number

Mating Square Back Box Catalog Numbers

20A 30A

AR30 AR30

ARRH/ARRC 13, 23, 33 ARRH/ARRC 13, 23, 33

60A

AR601

ARRH/ARRC 36, 46, 56

100A

AR100

AJ/AJC 46, 56

DIMENSIONS (INCHES):

Catalog Number AR30 AR601 AR100

1076

STIBOINFO((CRH:66008com:5P:1076)) CH0 0 4 F - 5

A 3.4 4.3 5.9

B 3.9 4.9 6.2

Receptacle/Inlet Footprint 2.74 x 2.74 3.03 x 3.34 4.09 x 4.09

US: 1-866-764-5454

CAN: 1-800-265-0502

100 Amp

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1077-5 Name: 5P-1077

DATE: JAN 19 2006

Time: 6:13:10 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Adapters Plates

csm no.: 100

5P

For 20, 30, 60 & 100 Amp IEC 309 Receptacles and Inlets

Cooper Crouse-Hinds H-Series Adapter Plates permit a Cooper Crouse-Hinds IEC 309 receptacle or inlet to be mounted to a Hubbell® back box.

FEATURES:

ɀ Heavy-duty aluminum plate fits directly to the Hubbell footprint. ɀ Adapter plate is engineered to be used with the gasket that is provided with the Cooper Crouse-Hinds receptacle or inlet. ɀ Provided gasket maintains watertight integrity between adapter plate and Hubbell box. ɀ Stainless steel hardware provided for attaching adapter plate to back box and receptacle or inlet to adapter plate. ɀ Corrosion resistant ɀ Quick and easy to install

ORDERING INFORMATION: Rating of Cooper Crouse-Hinds Receptacle or Inlet

Catalog Number of Hubbell Back Box

Adapter Plate Catalog Number

20A/30A

BB201W/BB301W

CHAP30H

60A 100A

BB601W/BB602W BB1001W/BB1002W

CHAP60H CHAP100H

DIMENSIONS (INCHES):

Overall Size

CHAP30H CHAP60H CHAP100H

A 4.03 4.53 5.53

B 3.78 4.53 5.53

Hubbell Footprint C 3.13 3.88 4.88

D 3.13 3.88 4.88

US: 1-866-764-5454

STIBOINFO((CRH:66008com:5P:1077)) CH0 0 4 F - 5

Cooper Crouse-Hinds Footprint E 2.74 3.03 4.09

F 2.74 3.35 4.09

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1077

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1078-2 Name: Note Page-1078

DATE: JAN 19 2006

Time: 6:13:11 PM Operator: JB

COLOR: CMYK

Notes Page

1078

STIBOINFO((CRH:66008com::1078)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1079-1 Name: 6P-1079

100: DATE: JAN 19 2006

Time: 6:13:12 PM Operator: RB

COLOR: CMYK

TCP: 15001

Wiring Devices With Covers Non-Hazardous

Typedriver Name: TS name

csm no.: 100

6P

Description

Page No.

Wet Location Covers Applications/Features Ordering Information

US: 1-866-764-5454

STIBOINFO((CRH:66008com:6P:1079)) CH0 0 0 0 6 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1080 1081

1079

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1080-1 Name: 6P-1080

6P

100: DATE: JAN 19 2006

Time: 6:13:13 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

WLRS, WLRD and WLGF Wet Location Covers For NEMA Configuration Receptacle Interiors For FS and FD Cast Device Boxes Flush Device Boxes

Application:

Standard Finishes:

WLRS, WLRD and WLGF series covers are suitable for use in wet and damp locations. WLGF is suitable for damp and wet locations only when cover is closed. WLRS and WLRD series wiring device covers are designed to meet the total NECode requirements for wet locations – Article 410-57: ‘‘A receptacle installed outdoors where exposed to weather or in other wet locations shall be in a weatherproof enclosure, the integrity of which is not affected when the receptacle is in use (attachment plug cap inserted).‘‘ Use WLRS, WLRD and WLGF: ɀ wherever portable equipment is required ɀ as general purpose utility receptacle covers ɀ for industrial, commercial or residential use ɀ in areas where electrical requirements do not exceed medium duty ratings ɀ to mount FS and FD single-gang or multigang boxes having individual cover openings (see Sect. 3F for listings) ɀ to mount on most flush device boxes (see Accessories)

ɀ Copper-free aluminum

Electrical Rating Ranges: ɀ 15 amperes; 125, 250, or 277 volts ɀ 20 and 30 amperes; 125, 250, 277, 480, 600, 125/250, 208/120, 480/277 or 600/347 volts

Accessories: Flush mounting adapter – WLRA-1 required for mounting on device boxes (not required with WLGF)

Certifications and Compliances: ɀ ANSI/UL Standard 514A ɀ NECode 410-57 ɀ NEMA Standards WD-1, 1983 (Straight Blade) and WD-5, 1982 (Locking Type)

Typical installation

Spring Door Covers – with Gasket*

Features: WLRS, WLRD and WLGF covers: ɀ self closing spring door assures protection of wiring device at all times, in wet and damp locations ɀ one piece EPDM gasket provides environmental protection of wiring device at all times ɀ Specially formulated elastomeric gasketing material offers excellent resistance to ozone, weather and temperature extremes of –50°F to 260°F ɀ die cast, copper-free aluminum construction with aluminum lacquer finish provides maximum corrosion resistance ɀ positive ground path ensured for all exposed metal parts NEMA configuration receptacle interiors: ɀ comply with NEMA Standards WD-1 and WD-5 ɀ grounded through an extra contact in all types except 3-phase applications; self grounded in duplex variety ɀ back and side wired ɀ offered in single and duplex configurations for use with standard plugs ɀ specification grade

Description Cat. #

Single cover WLRS-1 and WLRS-2

Duplex cover WLRD-1 * Patent Number 4,058,358

Dimensions

Standard Materials: ɀ WLRS, WLRD and WLGF face plate and cover – die cast copper-free aluminum ɀ Cover hinge spring – stainless steel ɀ Cover screws – corrosion resistant metal ɀ Gasket – WLRS and WLRD – ethylene propylene rubber (EPDM) ɀ Gasket – WLGF – neoprene

1080

STIBOINFO((CRH:66008com:6P:1080)) CH0 0 5 P - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1081-1 Name: 6P-1081

DATE: JAN 19 2006

Time: 6:14:08 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

WLRS, WLRD and WLGF Wet Location Covers

csm no.: 100

6P

Covers with and without NEMA Configuration Receptacles

Type

Volts

NEMA Configuration

Complete Cover with Receptacle Assy. Cat. #

Spring Door Cover & Gasket Only Cat. #‡

Single Device

Type

Volts

NEMA Configuration

Complete Cover with Receptacle Assy. Cat. #

Spring Door Cover & Gasket Only Cat. #‡

Duplex Device For Non-Locking Blade Plugs

2-Pole 3-Wire Grounding 15 Amp

125V

5-15R

WLRS-5-15

WLRS-1

250V

6-15R

WLRS-6-15

WLRS-1

2-Pole 3-Wire Grounding 20 Amp

125V

5-20R

WLRS-5-20

WLRS-1

250V

6-20R

WLRS-6-20

WLRS-1

2-Pole 3-Wire Grounding 15 Amp

125V

5-15R

WLRD-5-15

WLRD-1

250V

6-15R

WLRD-6-15

WLRD-1

2-Pole 3-Wire Grounding 20 Amp

125V

5-20R

WLRD-5-20

WLRD-1

250V

6-20R

WLRD-6-20

WLRD-1

L5-15R

WLRD-L5-15 WLRD-1

For Locking Blade Plugs 2-Pole 3-Wire Grounding 15 Amp

125V

L5-15R

WLRS-L5-15 WLRS-1

250V

L6-15R

WLRS-L6-15 WLRS-1

2-Pole 3-Wire Grounding 20 Amp

125V

L5-20R

WLRS-L5-20 WLRS-2

250V

L6-20R

WLRS-L6-20 WLRS-2

2-Pole 3-Wire Grounding 15 Amp

125V

Wet Location Covers for GFCI Duplex Receptacles

WLGF – For Flush Device Boxes

WLGF-FS – For FS and FD Cast Device Boxes

‡ Must be used with a wet locations rated wiring device. US: 1-866-764-5454

STIBOINFO((CRH:66008com:6P:1081)) CH0 0 5 P - 1

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1081

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1082-2 Name: Note Page-1082

DATE: JAN 19 2006

Time: 6:14:10 PM Operator: JB

COLOR: CMYK

Notes Page

1082

STIBOINFO((CRH:66008com::1082)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1083-1 Name: 7P-1083

100: DATE: JAN 19 2006

Time: 6:14:10 PM Operator: RB

COLOR: CMYK

TCP: 15001

Cable-Gard TM Industrial Cable Management System Non-Hazardous

Typedriver Name: TS name

csm no.: 100

7P

Description

Page No.

Static Discharge Reels

1085

Cable Reels Application Technical Data Lifting/Stretching Reels Retrieve Reels

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7P:1083)) CH0 0 0 0 6 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1086 1087 1088 1089

1083

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1084-2 Name: Note Page-1084

DATE: JAN 19 2006

Time: 6:14:11 PM Operator: RB

COLOR: CMYK

Notes Page

1084

STIBOINFO((CRH:66008com::1084)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1085-1 Name: 7P-1085

100: DATE: JAN 19 2006

Time: 6:14:12 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cable-Gard TM Static Discharge Reels

csm no.: 100

7P

Application: Static discharge reels are used for grounding portable machines and equipment in hazardous areas, such as fuel-transfer trucks, grain elevators, dockside-loading facilities and barges. When properly clamped to ground the static discharge reel safely dissipates static electrical buildup and reduces the chance of sparking and the potential for explosion.

Features: ɀ Automatic rewinding ɀ Rugged steel construction ɀ Compact enclosed design ɀ Positive ratchet lock ɀ Lock on/lock off switch ɀ Steel cable installed ɀ 100 amp universal jaw-type grounding clamp ɀ Safety orange polyester baked-on finish SDR-50

Standard Materials: ɀ Housing – steel construction

Standard Finishes: ɀ Housing – Orange polyester; baked on finish

Ordering Information: Cable Length (Feet) 50 50 50

Description Single 7 x 30 steel* 35′ plus 2 x 15′ for Y (steel*) Nylon covered cable*

Weight Complete lbs. (Kg) 12 (5.4) 13 (5.9) 12 (5.4)

Catalog Number SDR-50 SDR-50Y SDR-50N

* Static discharge reels are supplied complete with 3⁄32⍯ steel aircraft cable. DC resistance is approximately one ohm per 50 ft. of steel cable.

Dimensions

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7P:1085)) CH0 0 6 P - 0

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1085

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1086-2 Name: 7P-1086

7P

DATE: JAN 19 2006

Time: 6:14:13 PM Operator: RB

COLOR: CMYK

Application:

Options:

Cable-Gard cable reels are designed for the constant, predictable pull of a machine and are designed for reliable operation in many applications. Typical uses include travelling cars, mobile hoists and various objects being lifted under power such as lifting magnets on cranes.

ɀ Ball stop – keeps cable from rewinding out of reach in hand-pull applications. Cable Range Suffix to be O.D. Min./Max. added to Cat. No. .38 – .50 – C1 .50 – .75 – C2 .75 – 1.00 – C3

Features:

Ball stop may be ordered separately; use suffix number as catalog number.

Standard Materials:

Typedriver Name: TS name

NEMA 3,3R Raintight

Cable-Gard TM Cable Reels

ɀ Unitized slip ring assembly transfers current from stationary to rotary. Brushes are an integral part of the slip ring assembly. ɀ Safe to change spring motor that is sized per application, clock type spring with window shade type action. Sealed in disposable housing, spring is never exposed to unravel and possibly harm. ɀ Watertight cable entrance terminates cord to reel spool with positive grip, watertight seal. ɀ Large junction box with 3⁄4⍯ NPT conduit entrance may be positioned in choice of four directions. ɀ Multi-position roller guide is adjustable to 4 different positions. Allows easy adaptation of reel to positioning requirements of the application and controlled uniform retraction of cable onto spool. Roller guides are optional; consult factory. ɀ Baked-on powder epoxy finish provides tightly bonded, homogenous shield to abrasion and corrosion. ɀ Ratchet lock is provided for window shade type action. May be easily disengaged in field for constant tension applications.

TCP: 15001

ɀ Pivot base – Pivot base allows 340° rotation of reel. Required for applications demanding reel self-alignment to direction of the cable run. Suffix to be added to Cat. No. –S To order separately: Pivot Base Cat. No. PB14 PB16 PB19

Series W14 W16 W19

Certifications and Compliances: ɀ ANSI/UL 355 ɀ CSA C22.2 ɀ NEMA 3, 3R

ɀ Reel supplied less cable Suffix to be added to Cat. No. – NC

Electrical Ranges: ɀ 600 VAC (cable reel) ɀ Cord: #16 - #10, Type ‘‘SO’’, #8, Type ‘‘W’’, or Type ‘‘G’’ (see listings).

Dimensional Data:

ɀ Frame, spool – steel

Standard Finishes: ɀ Baked on powder epoxy – orange

Dimensions in inches Frame Size C W14 W16 W19

3.75 5.50 5.75

D 2.75 2.75 2.75

E F G 13.75 8.25 7.00 15.75 9.31 7.00 19.00 10.00 10.50

H 9.25 9.25 9.25

J 6.12 7.94 7.00

K 16.25 18.25 20.50

L M N 15.00 8.12 8.00 17.00 9.12 8.50 20.25 10.75 11.00

P 14.25 16.25 18.50

Q 2.50 3.00 3.50

R 1.25 1.25 1.25

Slip Ring Housing Dimensions: W14

1086

STIBOINFO((CRH:66008com:7P:1086)) CH0 0 6 P - 1

W16

W19

Poles/Amps

A

B

Poles/Amps

A

B

Poles/Amps

A

B

1–4; 30 Amps 5–8; 30 Amps 9–12; 30 Amps 1–4; 55 Amps

4.50 6.00 7.50 6.00

5.69 7.19 8.69 7.19

1–4; 30 Amps 5–8; 30 Amps 9–12; 30 Amps 1–4; 54 Amps

4.50 6.00 7.50 6.00

5.94 7.44 8.94 7.44

1–4; 30 Amps 5–8; 30 Amps 9–12; 30 Amps 1–4; 55 Amps

3.25 4.50 6.00 4.50

5.44 6.69 8.19 6.69

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1087-2 Name: 7P-1087

DATE: JAN 19 2006

Time: 6:14:14 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Raintight NEMA 3,3R

Cable-Gard TM Cable Reels

csm no.: 100

7P

Catalog Numbering System W

16

L



A

03

REEL SERIES

045 CABLE LENGTH (ft) NO. CONDUCTORS

SPOOL O.D. (approx. in.)

AWG APPLICATION L = Lift R = Retrieve

OPTIONAL ITEMS ORDERED AS SUFFIX REEL ORDERED WITHOUT CABLE ADD ‘‘–NC’’

A = #16 B = #14 C = #12 D = #10 E = #8 F = #8 Type ‘‘G’’†

W = Weathertight

† Type ‘‘G’’ cable is supplied with a ground conductor.

Reel Selection Process Determine: 1. CABLE SIZE AND NO. OF CONDUCTORS Be sure to choose cable that will adequately handle the current load (include ground when stating number of conductors). If the desired cable is not listed, consult factory. 2. CABLE LENGTH Reels in this brochure will handle up to 150 feet of cable. Decide how far your equipment will travel from the reel and choose the appropriate column. The amount of cable needed to install the cable on the reel has been included. However, you must add: 1) the amount of cable needed for HOOK-UP to your equipment, and 2) Cable SAG ALLOWANCE if ‘‘STRETCH’’ applications (see footnote *). Round up to the nearest footage on the selection chart. CABLE LENGTH NEEDED = EQUIPMENT TRAVEL DISTANCE PLUS HOOK-UP PLUS SAG ALLOWANCE. (Sag allowance needed for ‘‘stretch’’ applications only.) 3. TYPE OF CABLE This is important as stranding and construction vary. Cable-Gard reels are provided with cable as listed in the electrical ranges listing on page 1086. 4. APPLICATION

* Sag allowance must be considered when figuring cable length for STRETCH applications. Add 1 ft. of cable for each 50 ft. of working cable calculated for your application. (Working cable excludes hook-up length.)

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7P:1087)) CH0 0 6 P - 2

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1087

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1088-1 Name: 7P-1088

DATE: JAN 19 2006

Time: 6:14:19 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Lifting/Stretching Reels

7P

Reels for Lifting/Stretching EXAMPLE: A hoist is to travel 52 feet along an I-beam – this is a STRETCH application. Required cable is 4 Conductor/No. 14. Hook-up is 2 feet. The following EXAMPLES appear in bold type in the selection charts. 1. If the reel must be END MOUNTED, the required cable length would be 52 feet, plus 2 feet for the hook-up plus 2 feet for sag consideration*. Round up to 60 feet per the available footage in the chart below. The correct model to choose would be W16L-B04060.

2. If the reel may be CENTER MOUNTED, only half as much cable is required – it will be used in both directions. Half of the required length would be 26 feet, plus 2 feet for the hook-up plus 1 foot for sag consideration for a total of 29 feet. Round up to 30 feet and choose model W14L-B04030. A savings will be realized because less cable was used and, thus, a smaller reel was required.

Selection Chart Wire Size

No. of Cond. 3 4 6 8 10 12

20 Feet W14L-A03020 W14L-A04020 W14L-A06020 W16L-A08020 W16L-A10020 W16L-A12020

30 Feet W14L-A03030 W14L-A04030 W14L-A06030 W16L-A08030 W16L-A10030 W16L-A12030

40 Feet W14L-A03040 W14L-A04040 W14L-A06040 W16L-A08040 W16L-A10040 W16L-A12040

50 Feet W16L-A03050 W16L-A04050 W14L-A06050 W16L-A08050 W16L-A10050 W16L-A12050

60 Feet W16L-A03060 W16L-A04060 W16L-A06060 W16L-A08060 W19L-A10060 W19L-A12060

70 Feet W19L-A03070 W19L-A04070 W19L-A06070 W19L-A08070 W19L-A10070 W19L-A12070

3 4 6 8 10 12

W14L-B03020 W14L-B04020 W14L-B06020 W14L-B08020 W14L-B10020 W16L-B12020

W14L-B03030 W14L-B04030 W14L-B06030 W16L-B08030 W16L-B10030 W16L-B12030

W14L-B03040 W14L-B04040 W16L-B06040 W16L-B08040 W19L-B10040 W19L-B12040

W14L-B03050 W14L-B04050 W16L-B06050 W16L-B08050

W16L-B03060 W16L-B04060 W16L-B06060 W19L-B08060

W16L-B03070 W16L-B04070 W19L-B06070 W19L-B08070

3 4 6 8

W14L-C03020 W14L-C04020 W14L-C06020 W14L-C08020

W14L-C03030 W14L-C04030 W16L-C06030 W16L-C08030

W14L-C03040 W14L-C04040 W16L-C06040 W19L-C08040

W14L-C03050 W16L-C04050 W19L-C06050

W16L-C03060 W16L-C04060 W19L-C06060

W19L-C03070 W19L-C04070

10

3 4 6

W14L-D03020 W14L-D04020 W16L-D06020

W14L-D03030 W14L-D04030

W14L-D03040 W16L-D04040

W16L-D03050 W16L-D04050

W16L-D03060 W19L-D04060

W19L-D03070 W19L-D04070

2 3 3† 4

W14L-E02020 W16L-E03020 W14L-F03020 W16L-E04020

W16L-E02030 W16L-E03030 W16L-F03030 W16L-E04030

W16L-E02040 W19L-E03040 W19L-F03040 W19L-E04040

W19L-E02050

8

16

14

12

* Sag allowance must be considered when figuring cable length for STRETCH applications. Add 1 foot of cable for each 50 feet of working cable calculated for your application. (Working cable excludes hook-up length.) † Type ‘‘G’’ cable.

1088

STIBOINFO((CRH:66008com:7P:1088)) CH0 0 6 P - 3

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1089-1 Name: 7P-1089

DATE: JAN 19 2006

Time: 6:14:19 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Retrieve Reels

csm no.: 100

7P

Reels for Retrieving EXAMPLE: A moving car is to travel 55 feet. Required cable is 4 Conductor/No. 10. Extra cables needed to hook up to the car is 2 feet. The following EXAMPLES appear in bold type in the selection charts. 1. If the reel must be END MOUNTED, the required cable length would be 55 feet, plus 2 feet for the hook-up. Round up to 60 feet per the available footage in the chart below. The correct model to choose would be W19R-D04060.

2. If the reel may be CENTER MOUNTED, only half as much cable is required – it will be used in both directions. Half of the required length would be 27.5 feet, plus 2 feet for the hook-up for a total of 29.5 feet. Round up to 30 feet and choose model W14R-D04030. A savings will be realized because less cable was used and, thus, a smaller reel was required.

Selection Chart Wire Size

16

14

12

10

8

No. of Cond. 3 4 6 8 10 12 3 4 6 8 10 12 3 4 6 8 10 12 3 4 6 8 2 3 3† 4

20 Feet

30 Feet

40 Feet

W14R-A03020 W14R-A04020 W14R-A06020 W14R-A08020 W14R-A10020 W14R-A12020 W14R-B03020 W14R-B04020 W14R-B06020 W14R-B08020 W14R-B10020 W16R-B12020 W14R-C03020 W14R-C04020 W14R-C06020 W14R-C08020

W14R-A03030 W14R-A04030 W14R-A06030 W14R-A08030 W14R-A10030 W14R-A12030 W14R-B03030 W14R-B04030 W14R-B06030 W16R-B08030 W16R-B10030 W16R-B12030 W14R-C03030 W14R-C04030 W16R-C06030 W16R-C08030

W14R-A03040 W14R-A04040 W14R-A06040 W16R-A08040 W16R-A10040 W16R-A12040 W14R-B03040 W14R-B04040 W16R-B06040 W16R-B08040 W19R-B10040 W19R-B12040 W14R-C03040 W14R-C04040 W16R-C06040 W19R-C08040

W14R-D03020 W14R-D04020 W14R-D06020 W19R-D08020 W14R-E02020 W14R-E03020 W14R-F03020 W16R-E04020

W14R-D03030 W14R-D04030 W19R-D06030 W19R-D08030 W16R-E02030 W16R-E03030 W16R-F03030 W16R-E04030

50 Feet

60 Feet

70 Feet

W16R-A03050 W16R-A04050 W14R-A06050 W16R-A08050 W16R-A10050 W16R-A12050 W14R-B03050 W14R-B04050 W16R-B06050 W19R-B08050

W16R-A03060 W16R-A04060 W16R-A06060 W16R-A08060 W19R-A10060 W19R-A12060 W16R-B03060 W16R-B04060 W16R-B06060 W19R-B08060

W19R-A03070 W19R-A04070 W19R-A06070 W19R-A08070 W19R-A10070 W19R-A12070 W19R-B03070 W19R-B04070 W19R-B06070 W19R-B08070

W14R-C03050 W16R-C04050 W19R-C06050

W16R-C03060 W16R-C04060 W19R-C06060

W16R-C03070 W19R-C04070 W19R-06070

W14R-D03040 W16R-D04040 W19R-D06040

W16R-D03050 W16R-D04050

W16R-D03060 W19R-D04060

W16R-D03070 W19R-D04070

W16R-E02040 W19R-E03040 W19R-F03040 W19R-E04040

W19R-E02050

W20AR-E02060

† Type ‘‘G’’ cable.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:7P:1089)) CH0 0 6 P - 4

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1089

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1090-2 Name: Note Page-1090

DATE: JAN 19 2006

Time: 6:14:20 PM Operator: JB

COLOR: CMYK

Notes Page

1090

STIBOINFO((CRH:66008com::1090)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1091-1 Name: 8P-1091

100: DATE: JAN 19 2006

Time: 6:14:21 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Special Purpose Plugs and Receptacles Non-Hazardous

csm no.: 100

8P

Description

Page No.

Application/Selection

1092

Circuit Breaking Power Connectors – Arktrol® RPC Series Accessories Adapters and Back Boxes Dimensions General Information Listings

1106 1107 1108, 1109 1093-1094 1096-1103

Control Circuit and Power Connectors – Arktrol® RPE Series Accessories Adapters and Back Boxes Dimensions General Information Listings

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1091)) CH0 0 0 0 7 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1106 1107 1108, 1109 1093-1095 1104, 1105

1091

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1092-1 Name: 8P-1092

8P

DATE: JAN 19 2006

Time: 6:14:21 PM Operator: RB

COLOR: CMYK

TCP: 15001

Special Purpose Plugs and Receptacles Application

Application: Special purpose plugs and receptacles listed in this section are for use in non-hazardous areas, where environmental or application considerations require non-standard plugs and receptacles. Included in this section are ARK-trol® plugs and receptacles (RPC and RPE).

ARK-trol Plugs and Receptacles (RPC and RPE) ɀ Are used with a wide range of equipment requiring a variety of contact configurations under conditions of hard usage and exposure to rigorous environments. ɀ Two basic types: RPC – circuit breaking power connectors; RPE – control circuit, power and welding connectors. RPC – A variety of configurations (with a maximum of five-poles) are available for one and three-phase circuits. Electrical range is 30, 60, 100, 200 amperes at a maximum of 600 vac. RPE – A wider range of configurations are available. Range of amperages available up to 500 amperes at a maximum of 600 vac. Both types are available (either as standard or as option) with solder well terminals for high reliability, or crimp or pressure terminals for ease of installation. Listings on pages 1096 to 1105, show complete assemblies with mating plugs and components. For information on features, options, components and complete assemblies, see pages 1093 to 1095.

1092

STIBOINFO((CRH:66008com:8P:1092)) CH0 0 7 P - 0

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

Typedriver Name: TS name

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1093-1 Name: 8P-1093

100: DATE: JAN 19 2006

Time: 6:14:22 PM Operator: RB

COLOR: CMYK

TCP: 15001

ARK-trol® Electrical Connectors

Typedriver Name: TS name

csm no.: 100

8P

RPC Circuit Breaking Power Connectors RPE Control Circuit and Power Connectors

Application: ARK-trol RPC circuit breaking power connectors and RPE control circuit power connectors are used: ɀ with a wide variety of portable electrical equipment ɀ for connection of devices ranging from simple lighting units, power tools, and similar portables requiring only a power supply circuit, to sophisticated control and instrumentation assemblies requiring disconnect ɀ under conditions of hard usage and where exposed to dust, dirt, water, corrosion and chemical attack, providing high reliability and trouble-free service ɀ indoors or outdoors in non-hazardous areas of petroleum refineries, chemical and petrochemical plants, manufacturing plants, military installations and similar locations ɀ on machine tools and similar equipment

Features: ɀ All ARK-trol connectors have the same properties, characteristics and environmental capabilities outlined under ‘‘Compliances.’’

Construction: ɀ All ARK-trol plug, receptacle and cord connector shell parts are of high-strength impact extruded aluminum, hard coated with a high density anodize finish. The resultant assemblies are light weight, extremely strong, free from surface defects and flaws, and with superior resistance to abrasion, corrosion and chemical attack. ɀ ‘‘Tri-Disc’’ insert assemblies consist of two rigid insulators with a silicone rubber wafer between to provide a cushioning action against mechanical damage and to effect a positive seal against penetration by water, moisture, dust, gas and other undesirable matter. Assembly of the inserts compresses the silicone wafer to seal against the inner wall of the plug or receptacle shell, and around each individual contact. ɀ ARK-trol insulating material is of high dielectric and mechanical strength with low moisture absorption and excellent resistance to arc tracking. Socket contacts are each enclosed in a separate chamber in the silo insulator. Arcs formed while making or breaking a circuit are quickly snuffed out in the chambers. ɀ Contacts are removable and, for ease of installation, are snapped into the insert assemblies after wire termination. Termination methods employed are solder, crimp and pressure. Solder well contacts are standard and are furnished unless otherwise specified. Crimp contacts are available in all sizes and configurations. Pressure contacts, due to increased terminal area, are available only in certain assemblies as shown in the listings.

ɀ For cable strain relief and watertight seal, plugs and cord connector recpetacles are provided with gland nut and tapered Neoprene bushing.

Positive Polarization: ɀ Polarization of ARK-trol connectors is such that plugs and receptacles cannot be mated incorrectly. ɀ Insert assemblies must be correctly aligned and will fit plug and receptacle shells in one position only, because of a raised key on the inner wall of the shells. ɀ Seven keys on the inner wall of the receptacle and seven mating keyways on the outer diameter of the plug shell are spaced so that the plug and receptacle can be mated in one position only. One key and one keyway are larger than the other six as a guide to rapid connection, easily performed under adverse field conditions – even in total darkness.

STIBOINFO((CRH:66008com:8P:1093))

ɀ Alternate polarities – ungrounded connectors. Standard polarity is position ‘‘N’’ shown below. Alternate positions ‘‘V’’, ‘‘W’’, ‘‘X’’ or ‘‘Y’’ can be furnished. To order, substitute for the letter ‘‘N’’ in the listed Cat. No., the letter for the desired polarization. Example: RPC217-127–SO1N-ARE23 with polarity ‘‘X’’ becomes RCP217-127–SO1X-ARE23.

Interchangeability: ɀ Shell components and insert assemblies in each diameter are interchangeable. Both male and female basic shells will accept either pin or socket inserts. This feature permits the use of both plug and receptacle in either an energized or de-energized condition.

Grounding: ɀ Grounded connectors have pin and socket contacts with integral grounding straps which press against the inner wall of plug, receptacle and cord connector shells, effectively bonding the shells to the grounding contacts. ɀ Grounding socket contacts are longer than current carrying contacts to make first and break last, assuring a positive ground before circuits are energized and after circuits are de-energized.

ɀ Alternate polarities – grounded connectors. Standard polarity is position ‘‘A’’ shown below. Alternate positions ‘‘B’’, ‘‘C’’, ‘‘D’’ or ‘‘E’’ can be furnished. To order, substitute for the letter ‘‘A’’ in the listed Cat. No., the letter for the desired polarization. Example: RPC217-127–SO2A-ARE23 with polarity ‘‘D’’ becomes RPC217-127–SO2D-ARE23.

Standard Materials: ɀ Back boxes and adapters – copper-free aluminum ɀ Plug, receptacle and cord connector shells – impact extruded aluminum ɀ Insulation – diallyl phthalate (DAP) ɀ Insulation – fiberglass-reinforced polyester material ɀ Sealing wafer – silicone rubber ɀ Contacts – hard drawn copper

Standard Finishes: ɀ Copper-free aluminum – natural ɀ Impact extruded aluminum – hard coat anodized ɀ Diallyl phthalate – natural (blue) ɀ Fiberglass-reinforced polyester material – natural (red) ɀ Silicone – natural (grey) ɀ Copper – silver plated

US: 1-866-764-5454

CH0 0 7 P - 1

Options:

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1093

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1094-2 Name: 8P-1094

8P

100: DATE: JAN 19 2006

Time: 6:14:23 PM Operator: RB

COLOR: CMYK

ARK-trol® Electrical Connectors

TCP: 15001

Typedriver Name: TS name

Raintight

RPC Circuit Breaking Power Connectors RPE Control Circuit and Power Connectors

RPC Circuit Breaking Connectors

Options

(continued): ɀ Crimp type contacts – available on all assemblies with solder well contacts. To order, add letter ‘‘T’’ to Cat. No., immediately following polarity letter. Examples: RPC217-127–S01N-ARE23 and RPC217-127–S02A-ARE23 except with crimp contacts would be ordered as RPC217-127–S01NT-ARE23 and RPC217-127–S02AT-ARE23 respectively. ɀ Alternate cable strain relief methods for plugs and connectors: Stainless steel wire mesh cord grip. To order, add letter ‘‘K’’ to first section of Cat. No. Example: RPC117-150–P01N with wire mesh grip would be ordered as RPCK117-150–P01N.

Adapter for use with liquid tight/rigid conduit. To order, add letters ‘‘LT’’ to first section of catalog number.

Contact Size AWG #16 #12 #10 #4 1/0 4/0

NEC Rating 20A 30A 60A 100A 200A

RPE Connectors Non-Interrupting Ampere Rating MS(AN) NEC 22 16 41 30 57 40 135 90 250 160 335 225

Certifications and Compliances: ɀ Properties

Characteristics

Industrial use

excludes dust, lint, fibers and flying, oil seepage and coolant seepage – meets J.I.C. Standard

Driptight

excludes falling moisture or dirt – materials unaffected by condensation

Weather resistant

performs normally in outdoor areas

(weatherproof) Watertight

excludes water by hose spray or stream

Dust tight

excludes dust, but performs normally if dust is accidentally enclosed during disconnect

Chemical resistance

high resistant to alkalis, strong caustics, acids, petroleum base and organic solvents

ɀ Voltage – 250, 480 and 600vac ɀ Frequency – 50** to 400 hertz ɀ See listings for specific ratings.

Pressure

300 psi external – 200 psi internal

Ampere Ratings:

Environment

Performance Data

ɀ Ratings given in the table at right are applicable to RPC circuit breaking power connectors and RPE control connectors, as indicated. ɀ RPC connectors are capable of making or breaking circuits at the full rated load indicated in the table on the listing pages. ɀ Contact assemblies of RPE connectors have the current carrying capabilities shown in the table, as defined by applicable military specifications (MS) and NEC requirements, for circuits not made or broken under load. It should be noted that these non-interrupting ampere ratings exceed the NEC rating of the corresponding wire size.

Corrosion resistance

salt spray 300 days. MIL-STD-810E

Temperature

–80°F to 275°F, meeting requirements of MIL-STD-810E

Air leakage

exceeds Class E specification MIL-STD-810E

Dust resistance

exceeds requirements of MIL-STD-810E

Shock resistance

50G exceeds MIL-STD-810E

Vibration

exceeds 20G, method II, MIL-STD-810E

Humidity & moisture

exceeds Class E specification MIL-STD-810E

ANSI/UL Standard

498

Example: RPC117-150–P01N with liquid tight/conduit adapter would be ordered as RPCLT117-150–P01N.

Electrical Rating Ranges:

ɀ Compliance with Military Specifications

** For use on system less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

1094

STIBOINFO((CRH:66008com:8P:1094)) CH0 0 7 P - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1095-2 Name: 8P-1095

100: DATE: JAN 19 2006

Time: 6:14:23 PM Operator: RB

COLOR: CMYK

TCP: 15001

ARK-trol® Electrical Connectors

Typedriver Name: TS name

csm no.: 100

8P

Catalog Numbering System

RPC

2

21–

014–

S

02

N

R

/

–ARE23 (Optional) Back Box

Connector Series

(Optional) If Plugged Contact Openings Are Required

(Optional) Additional Cable Strain Relief Shell Parts Designation Shell Size

Contact Termination

Component Accessories

Polarity Designation Contact Configuration Contact Type

CONNECTOR SERIES RPC – circuit breaking RPE – for disconnect use only RPX – hazardous (gasoline or equivalent hazards, see Section 9P) ADDITIONAL CABLE STRAIN RELIEF (Optional) K ⍧ Wire mesh cord grip LT ⍧ Liquidtight/conduit connection SHELL PARTS DESIGNATION 0 ⍧ No shell part required 1 ⍧ Plug shell 2 ⍧ Receptacle 3 ⍧ Cord connector 4 ⍧ Connector handle body only 5 ⍧ Plug shell (long) 6 ⍧ Receptacle (long) 7 ⍧ Cord connector (long)

COMPONENT ACCESSORIES This code indicates the combination of shell parts to fit your application; e.g., 014 ⍧ square flanged receptacle with insert retaining nut and dust cap; 150 ⍧ plug handle body, bushing, and clamping nut for cable with a diameter of .250 to .625. CONTACT TYPE P ⍧ Pin (male) S ⍧ Socket (female) CONTACT CONFIGURATION This assigned code indicates the actual configuration of the contacts (pin and socket) in the insert assembly for a particular shell size. This is based upon electrical ratings (amperage and voltage) and the number of contacts required. It does not indicate the number of contacts in the configuration.

SHELL SIZE Inside Diameter measured in X/16⍯ (017, 021, 033, 041, i.e., 017 shell size ⍧ 17⁄16⍯)

STIBOINFO((CRH:66008com:8P:1095))

PLUGGED CONTACT OPENINGS (Optional) This option allows greater flexibility, allowing for unique wiring requirements. The number following the slash indicates the total number of contacts that will be supplied (including ground contact, if applicable); all other openings in the insert assembly will be plugged. BACK BOXES (Optional) See page 1107 for back box information.

POLARITY DESIGNATION N ⍧ Standard position – ungrounded V, W, X or Y ⍧ Alternate positions – (ungrounded) A ⍧ Standard position – grounded B, C, D or E ⍧ Alternate positions – (grounded)

US: 1-866-764-5454

CH0 0 7 P - 3

CONTACT TERMINATION Blank ⍧ Solder well (standard unless noted) R ⍧ Pressure (See complete ordering information that follows for availability) T ⍧ Crimp (available in all configurations)

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1095

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1096-1 Name: 8P-1096

8P

100: DATE: JAN 19 2006

Time: 6:14:24 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Raintight

ARK-trol Electrical Connectors RPC Circuit Breaking Power Connectors With Solder Well Terminals 1

Circuit Description

Contact Size

Shell Size

20 AMPS Grounded

4w, 5p

480

#12

017

Ungrounded

5w, 5p

480

#12

017

30 AMPS Grounded

2w, 3p

480

#10

017

3w, 4p

480

#10

017

4w, 5p

480

#10

021

3w, 3p

480

#10

017

4w, 4p

480

#10

017

5w, 5p

480

#10

021

3w, 4p

600

#4

4w, 5p

480

4w, 4p

5w, 5p

Ungrounded

60 AMPS Grounded

Ungrounded

1096

STIBOINFO((CRH:66008com:8P:1096)) CH0 0 7 P - 4

Volts (VAC)

Hub Size

Square Flanged Receptacle, Dust Cap and Back Box Cat. # (For Surface Mounting) 2, 3

Motor Plug with Dust Cap Cat. #

3⁄4 1 3⁄4 1

RPC217-014-S09A-ARE23 RPC217-014-S09A-ARE33 RPC217-014-S08N-ARE23 RPC217-014-S08N-ARE33

RPC117-157-P09A

3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1 3⁄4 1

RPC217-014-S02A-ARE23 RPC217-014-S02A-ARE33 RPC217-014-S04A-ARE23 RPC217-014-S04A-ARE33 RPC221-014-S17A-ARE23 RPC221-014-S17A-ARE33 RPC217-014-S01N-ARE23 RPC217-014-S01N-ARE33 RPC217-014-S03N-ARE23 RPC217-014-S03N-ARE33 RPC221-014-S16N-ARE23 RPC221-014-S16N-ARE33

RPC117-157-P02A

033

11⁄4 11⁄2

RPC233-014-S08A-ARE46 RPC233-014-S08A-ARE56

RPC133-157-P08A

#4

033

11⁄4 11⁄2

RPC233-014-S09A-ARE46 RPC233-014-S09A-ARE56

RPC133-157-P09A

600

#4

033

11⁄4 11⁄2

RPC233-014-S05N-ARE46 RPC233-014-S05N-ARE56

RPC133-157-P05N

480

#4

033

11⁄4 11⁄2

RPC233-014-S06N-ARE46 RPC233-014-S06N-ARE56

RPC133-157-P06N

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

RPC117-157-P08N

RPC117-157-P04A RPC121-157-P17A RPC117-157-P01N RPC117-157-P03N RPC121-157-P16N

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1097-3 Name: 8P-1097

DATE: JAN 19 2006

Time: 6:14:25 PM Operator: JB COLOR: CMYK

TCP: 15001

Raintight

ARK-trol Electrical Connectors

Typedriver Name: TS name csm no.: 100

8P

RPC Circuit Breaking Power Connectors With Solder Well Terminals 1

Cord Connector Cat. #4

Plug Cat. #4

.625 .875 .625 .875

RPC317-160-S09A RPC317-161-S09A RPC317-160-S08N RPC317-161-S08N

RPC117-150-P09A RPC117-151-P09A RPC117-150-P08N RPC117-151-P08N

.250 to .625 .625 to .875

RPC317-160-S02A RPC317-161-S02A

RPC117-150-P02A RPC117-151-P02A

.250 to .625 .625 to .875 .625 to 1.000 1.000 to 1.187 .250 to .625 .625 to .875 .250 to .625 .625 to .875

RPC317-160-S04A RPC317-161-S04A RPC321-161-S17A RPC321-395-S17A RPC317-160-S01N RPC317-161-S01N RPC317-160-S03N RPC317-161-S03N

RPC117-150-P04A RPC117-151-P04A RPC121-151-P17A RPC121-387-P17A RPC117-150-P01N RPC117-151-P01N RPC117-150-P03N RPC117-151-P03N

.625 to 1.000 1.000 to 1.187

RPC321-161-S16N RPC321-395-S16N

RPC121-151-P16N RPC121-387-P16N

.875 to 1.375 1.375 to 1.625 1.625 to 1.875 .875 to 1.375 1.375 to 1.625 1.625 to 1.875 .875 to 1.375 1.375 to 1.625 1.625 to 1.875 .875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPC333-163-S08A RPC333-396-S08A RPC333-397-S08A RPC333-163-S09A RPC333-396-S09A RPC333-397-S09A RPC333-163-S05N RPC333-396-S05N RPC333-397-S05N RPC333-163-S06N RPC333-396-S06N RPC333-397-S06N

RPC133-153-P08A RPC133-388-P08A RPC133-389-P08A RPC133-153-P09A RPC133-388-P09A RPC133-389-P09A RPC133-153-P05N RPC133-388-P05N RPC133-389-P05N RPC133-153-P06N RPC133-388-P06N RPC133-389-P06N

Cable Diameter Range .250 to .625 to .250 to .625 to

FOOTNOTES: 1 Solder well terminals provided as standard. Crimp contacts are optionally available, add suffix T to catalog number. Example: RPC217-014-S09AT-ARE23. 2 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 014 to 127. Example: RPC217-127-S09A-ARE23. 3 For square flanged receptacle with dust cap for panel mounting, delete the last digits of the catalog number specifying the backbox. Example: RPC217-014-S09A. 4 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to first section of catalog number. Example: RPCLT317-160-S09A. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of catalog number. Example: RPCK317-160-S09A.

NOTE: RPC with pressure terminals are shown on pages 1100 through 1103.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1097)) CH0 0 7 P - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1097

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1098-1 Name: 8P-1098

8P

100: DATE: JAN 19 2006

Time: 6:14:26 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Raintight

ARK-trol Electrical Connectors RPC Circuit Breaking Power Connectors With Solder Well Terminals 1

Circuit Description

Contact Size

Shell Size

Hub Size

Motor Plug Cat. #

100 AMPS Grounded

4w, 5p

600

1⁄0

041

11⁄2 2

RPC641-014-S04A-AJ57 RPC641-014-S04A-AJ67

RPC541-157-P04A

Ungrounded

5w, 5p

600

1⁄0

041

11⁄2 2

RPC641-014-S02N-AJ57 RPC641-014-S02N-AJ67

RPC541-157-P02N

200 AMPS Grounded

3w, 4p

480

4⁄0

041

2 21⁄2

RPC641-014-S10A-AJ68 RPC641-014-S10A-AJ78

RPC541-157-P10A

1098

STIBOINFO((CRH:66008com:8P:1098)) CH0 0 7 P - 6

Volts (VAC)

Square Flanged Receptacle, Dust Cap and Back Box Cat. # (For Surface Mounting) 2, 3

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1099-3 Name: 8P-1099

DATE: JAN 19 2006

Time: 6:14:27 PM Operator: JB COLOR: CMYK

TCP: 15001

Raintight

ARK-trol Electrical Connectors

Typedriver Name: TS name csm no.: 100

8P

RPC Circuit Breaking Power Connectors With Solder Well Terminals 1

Cable Diameter Range

Cord Connector Cat. #4

Plug Cat. #4

1.375 to 1.875 1.875 to 2.062 2.062 to 2.250

RPC741-164-S04A RPC741-398-S04A RPC741-399-S04A

RPC541-154-P04A RPC541-390-P04A RPC541-391-P04A

1.375 to 1.875 1.875 to 2.062 2.062 to 2.250

RPC741-164-S02N RPC741-398-S02N RPC741-399-S02N

RPC541-154-P02N RPC541-390-P02N RPC541-391-P02N

1.375 to 1.875 1.875 to 2.062 2.062 to 2.250

RPC741-164-S10A RPC741-398-S10A RPC741-399-S10A

RPC541-154-P10A RPC541-390-P10A RPC541-391-P10A

FOOTNOTES: 1 Solder well terminals provided as standard. Crimp contacts are optionally available, add suffix T to catalog number. Example: RPC217-014-S09AT-ARE23. 2 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 014 to 127. Example: RPC217-127-S09A-ARE23. 3 For square flanged receptacle with dust cap for panel mounting, delete the last digits of the catalog number specifying the backbox. Example: RPC217-014-S09A. 4 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to first section of catalog number. Example: RPCLT317-160-S09A. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of catalog number. Example: RPCK317-160-S09A.

NOTE: RPC with pressure terminals are shown on pages 1100 through 1103.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1099)) CH0 0 7 P - 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1099

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1100-1 Name: 8P-1100

8P

100: DATE: JAN 19 2006

Time: 6:14:28 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Raintight

ARK-trol Electrical Connectors RPC Circuit Breaking Power Connectors With Pressure Terminals

Circuit Description

Volts (VAC)

Contact Size

Shell Size

Hub Size

Square Flanged Receptacle, Dust Cap and Back Box Cat. # (For Surface Mounting) 1, 2

30 AMPS Grounded

2w, 3p

600

#10

021

3⁄4 1

RPC221-014-S04AR-ARE23 RPC221-014-S04AR-ARE33

RPC121-157-P04AR

Ungrounded

3w, 3p

600

#10

021

3⁄4 1

RPC221-014-S02NR-ARE23 RPC221-014-S02NR-ARE33

RPC121-157-P02NR

60 AMPS Grounded

3w, 4p

600

#4

033

11⁄4 11⁄2

RPC233-014-S08AR-ARE46 RPC233-014-S08AR-ARE56

RPC133-157-P08AR

4w, 5p

480

#4

033

11⁄4 11⁄2

RPC233-014-S09AR-ARE46 RPC233-014-S09AR-ARE56

RPC133-157-P09AR

4w, 4p

600

#4

033

11⁄4 11⁄2

RPC233-014-S05NR-ARE46 RPC233-014-S05NR-ARE56

RPC133-157-P05NR

5w, 5p

480

#4

033

11⁄4 11⁄2

RPC233-014-S06NR-ARE46 RPC233-014-S06NR-ARE56

RPC133-157-P06NR

Ungrounded

† For alternate polarizations, see ‘‘Options’’ on page 1093.

1100

STIBOINFO((CRH:66008com:8P:1100)) CH0 0 7 P - 8

Motor Plug Cat. #

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1101-3 Name: 8P-1101

DATE: JAN 19 2006

Time: 6:14:29 PM Operator: JB COLOR: CMYK

TCP: 15001

Raintight

ARK-trol Electrical Connectors

Typedriver Name: TS name csm no.: 100

8P

RPC Circuit Breaking Power Connectors With Pressure Terminals

Cable Diameter Range

Cord Connector Cat. #3

.250 to .625 .625 to 1.000

RPC321-160-S04AR RPC321-161-S04AR

RPC121-150-P04AR RPC121-151-P04AR

.250 to .625 .625 to 1.000

RPC321-160-S02NR RPC321-161-S02NR

RPC121-150-P02NR RPC121-151-P02NR

.875 to 1.375 1.375 to 1.625 1.625 to 1.875 .875 to 1.375 1.375 to 1.625 1.625 to 1.875 .875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPC333-163-S08AR RPC333-396-S08AR RPC333-397-S08AR RPC333-163-S09AR RPC333-396-S09AR RPC333-397-S09AR RPC333-163-S05NR RPC333-396-S05NR RPC333-397-S05NR

RPC133-153-P08AR RPC133-388-P08AR RPC133-389-P08AR RPC133-153-P09AR RPC133-388-P09AR RPC133-389-P09AR RPC133-153-P05NR RPC133-388-P05NR RPC133-389-P05NR

.875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPC333-163-S06NR RPC333-396-S06NR RPC333-397-S06NR

RPC133-153-P06NR RPC133-388-P06NR RPC133-389-P06NR

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1101)) CH0 0 7 P - 9

Plug Cat. #3

CAN: 1-800-265-0502

FOOTNOTES: 1 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 014 to 127. Example: RPC221-127-S04AR-ARE23. 2 For square flanged receptacle with dust cap for panel mounting, delete the last digits of the catalog number specifying the backbox. Example: RPC221-014-S04AR. 3 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to first section of catalog number. Example: RPCLT321-160-S04AR. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of catalog number. Example: RPCK321-160-S04AR.

Copyright© 2006 Cooper Crouse-Hinds

1101

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1102-1 Name: 8P-1102

8P

100: DATE: JAN 19 2006

Time: 6:14:29 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Raintight

ARK-trol Electrical Connectors RPC Circuit Breaking Power Connectors With Pressure Terminals

Circuit Description

Volts (VAC)

Contact Size

Shell Size

Hub Size

Square Flanged Receptacle, Dust Cap and Back Box Cat. # (For Surface Mounting) 1, 2

100 AMPS Grounded

4w, 5p

600

1⁄0

041

11⁄2 2

RPC641-014-S04AR-AJ57 RPC641-014-S04AR-AJ67

RPC541-157-P04AR

Ungrounded

5w, 5p

600

1⁄0

041

11⁄2 2

RPC641-014-S02NR-AJ57 RPC641-014-S02NR-AJ67

RPC541-157-P02NR

† For alternate polarizations, see ‘‘Options’’ on page 1093.

1102

STIBOINFO((CRH:66008com:8P:1102)) CH0 7 P - 1 0

Motor Plug Cat. #

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1103-3 Name: 8P-1103

DATE: JAN 19 2006

Time: 6:15:35 PM Operator: JB COLOR: CMYK

TCP: 15001

Raintight

ARK-trol Electrical Connectors

Typedriver Name: TS name csm no.: 100

8P

RPC Circuit Breaking Power Connectors With Pressure Terminals

Cable Diameter Range

Cord Connector Cat. #3

1.375 to 1.875 1.875 to 2.062 2.062 to 2.250

RPC741-164-S04AR RPC741-398-S04AR RPC741-399-S04AR

RPC541-154-P04AR RPC541-390-P04AR RPC541-391-P04AR

1.375 to 1.875 1.875 to 2.062 2.062 to 2.250

RPC741-164-S02NR RPC741-398-S02NR RPC741-399-S02NR

RPC541-154-P02NR RPC541-390-P02NR RPC541-391-P02NR

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1103)) CH0 7 P - 1 1

Plug Cat. #3

CAN: 1-800-265-0502

FOOTNOTES: 1 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 014 to 127. Example: RPC221-127-S04AR-ARE23. 2 For square flanged receptacle with dust cap for panel mounting, delete the last digits of the catalog number specifying the backbox. Example: RPC221-014-S04AR. 3 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to first section of catalog number. Example: RPCLT321-160-S04AR. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of catalog number. Example: RPCK321-160-S04AR.

Copyright© 2006 Cooper Crouse-Hinds

1103

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1104-1 Name: 8P-1104

8P

100: DATE: JAN 19 2006

Time: 6:15:36 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Raintight

ARK-trol Electrical Connectors RPE Control Circuit and Power Connectors With Solder Well Terminals 1

Circuit Description POWER

CONTROL

1104

STIBOINFO((CRH:66008com:8P:1104)) CH0 7 P - 1 2

Contact Size Amps

Volts (VAC)

Shell Size

500 MCM

500

600

033

11⁄2 2

RPE633-014-S24N-AJ57 RPE633-014-S24N-AJ67

RPE533-157-P24N

6w, 7p

#12

20

480

017

3⁄4 1

RPE217-014-S06A-ARE23 RPE217-014-S06A-ARE33

RPE117-157-P06A

7w, 7p

#12

20

480

017

3⁄4 1

RPE217-014-S05N-ARE23 RPE217-014-S05N-ARE33

RPE117-157-P05N

12w, 12p

#16

16

250

017

3⁄4 1

RPE217-014-S07N-ARE23 RPE217-014-S07N-ARE33

RPE117-157-P07N

18w, 19p

#12

20

250

021

3⁄4 1

RPE221-014-S08A-ARE23 RPE221-014-S08A-ARE33

RPE121-157-P08A

19w, 19p

#12

20

250

021

3⁄4 1

RPE221-014-S09N-ARE23 RPE221-014-S09N-ARE33

RPE121-157-P09N

38w, 39p

#12

20

250

033

11⁄4 11⁄2

RPE233-014-S19A-ARE46 RPE233-014-S19A-ARE56

RPE133-157-P19A

39w, 39p

#12

20

250

033

11⁄4 11⁄2

RPE233-014-S17N-ARE46 RPE233-014-S17N-ARE56

RPE133-157-P17N

1w, 1p

US: 1-866-764-5454

CAN: 1-800-265-0502

Hub Size

Square Flanged Receptacle, Dust Cap and Back Box Cat. # (For Surface Mounting) 2, 3

Copyright© 2006 Cooper Crouse-Hinds

Motor Plug Cat. #

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1105-3 Name: 8P-1105

DATE: JAN 19 2006

Time: 6:15:37 PM Operator: JB COLOR: CMYK

TCP: 15001

Raintight

ARK-trol Electrical Connectors

Typedriver Name: TS name csm no.: 100

8P

RPE Control Circuit and Power Connectors With Solder Well Terminals

Cable Diameter Range

Cord Connector Cat. #4

1.375 to 1.625 1.625 to 1.875

RPE733-396-S24N RPE733-397-S24N

RPE533-388-P24N RPE533-389-P24N

.250 to .625 .625 to .875

RPE317-160-S06A RPE317-161-S06A

RPE117-150-P06A RPE117-151-P06A

.250 to .625 .625 to .875

RPE317-160-S05N RPE317-161-S05N

RPE117-150-P05N RPE117-151-P05N

.250 to .625 .625 to .875

RPE317-160-S07N RPE317-161-S07N

RPE117-150-P07N RPE117-151-P07N

.625 to 1.000 1.000 to 1.187

RPE321-161-S08A RPE321-395-S08A

RPE121-151-P08A RPE121-387-P08A

.625 to 1.000 1.000 to 1.187

RPE321-161-S09N RPE321-395-S09N

RPE121-151-P09N RPE121-387-P09N

.875 to 1.375 1.375 to 1.625

RPE333-163-S19A RPE333-396-S19A

RPE133-153-P19A RPE133-388-P19A

.875 to 1.375 1.375 to 1.625

RPE333-163-S17N RPE333-396-S17N

RPE133-153-P17N RPE133-388-P17N

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1105)) CH0 7 P - 1 3

Plug Cat. #4

CAN: 1-800-265-0502

FOOTNOTES: 1 Solder well terminals provided as standard. Crimp contacts are optionally available, add suffix T to catalog number. Example: RPE633-014-S24NT-AJ57. 2 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 014 to 127. Example: RPE633-127-S24N-AJ57. 3 For square flanged receptacle with dust cap for panel mounting, delete the last three digits of the catalog number specifying the backbox. Example: RPE633-014-S24N. 4 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to the first section of the catalog number. Example: RPELT733-396-S24N. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of the catalog number. Example: RPEK733-396-S24N.

Copyright© 2006 Cooper Crouse-Hinds

1105

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1106-1 Name: 8P-1106

8P

DATE: JAN 19 2006

Time: 6:15:44 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

RPC and RPE Connectors Accessories

DUST CAPS: For Receptacles

FOR #16 THROUGH #10 CONTACTS:

For RPC or RPE Series

The RPE017-440 crimping tool has been designed to crimp a wide range of solid and stranded type conductors. The crimping head is adjusted and sealed at the factory. The tool automatically crimps and gauges all size contacts without readjustment.

Dust Cap w/Eyelet for Receptacle Cat. # RPE017-009 RPE021-009 RPE033-009 RPE041-009

CONTACT REMOVAL TOOLS: The contact removal tool extracts the contact from the insert assembly without complete disassembly of the connector. RPE017-402T for use with #16 contacts. RPE017-403T for use with #12 contacts. RPE017-404T for use with #10 contacts.

1106

STIBOINFO((CRH:66008com:8P:1106)) CH0 7 P - 1 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1107-2 Name: 8P-1107

100: DATE: JAN 19 2006

Time: 6:15:45 PM Operator: JB COLOR: CMYK

TCP: 15001

Typedriver Name: TS name csm no.: 100

Back Boxes and Adapters

8P

For Mounting RPC and RPE Square Flanged Receptacles

45° Angle adapter

Back Boxes

Adapters

FS and FSC

FS Back box

ARE Back box

AJ Back box

Hub Size 1⁄2 3⁄4 1

FS† Cat. # FS1-SA FS2-SA FS3-SA

Flat adapter

Shell Sizes of Square Flanged Receptacles FSC† Cat. # FSC1-SA FSC2-SA FSC3-SA

45° Angle

Flat

017 Cat. #

021 Cat. #

017 Cat. #

021 Cat. #

RPE017-156

RPE021-156

RPE017-141

RPE021-142

ARE‡

Shell Sizes of Square Flanged Receptacles

Hub Size 1⁄2 3⁄4 1

Flat Cat. # ARE13 ARE23 ARE33

1 11⁄4 11⁄2

ARE36 ARE46 ARE56

Rating

017 Cat. #

021 Cat. #

30A

RPE017-143

RPE021-144

60A

033 Cat. #

041 Cat. #

RPE033-145

RPE041-146

AJ‡

Shell Sizes of Square Flanged Receptacles

Hub Size 1 11⁄4 11⁄2 2

Flat

11⁄2 2 21⁄2

Cat. # AJ37 AJ47 AJ57 AJ67 AJ58 AJ68 AJ78

Rating 60A and 100A

200A

033 Cat. #

041 Cat. #

RPE033-145

RPE041-146

RPE041-147

† Any of the FS or FD single gang, two gang tandem or multiple gang boxes with individual cover openings may be used with these adapters. For listings, dimensions and other details refer to Section 3F. ‡ Other AR and AJ back boxes may be used with these adapters. For listings, dimensions and other details refer to Section 1P.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1107)) CH0 7 P - 1 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1107

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1108-1 Name: 8P-1108

8P

100: DATE: JAN 19 2006

Time: 6:15:47 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

ARK-trol® Electrical Connectors RPC Circuit Breaking Power Connectors RPE Control Circuit and Power Connectors Dimensions Square Flanged Receptacle Shell Type and Size 217 221 233 241 633 641 a .1875 .250 .375 .500

b c d 1.375 1.317 2.165 1.750 1.692 2.165 2.375 2.317 2.165 2.813 2.817 2.165 2.375 2.317 2.915 2.813 2.817 2.915 Contact for AWG Wire #16, #12, #10 #4 1⁄0 4⁄0

e 1.562 2.000 2.625 3.187 2.625 3.187

f .190 .190 .214 .250 .214 .250

g 1.750 2.250 2.875 3.438 2.875 3.438

Square Flanged Receptacle with Dust Cap Shell Type and Size 217 221 233 241 633 641

b 1.375 1.750 2.375 2.813 2.375 2.813

c 1.317 1.692 2.317 2.817 2.317 2.817

d 2.812 2.812 2.812 2.812 3.552 3.552

e 1.927 2.468 3.145 3.754 3.145 3.754

f .190 .190 .214 .250 .214 .250

g 1.750 2.250 2.875 3.438 2.875 3.438

NOTE: Dimension a – same as above

Plug Shell Type and Size 117 121 133 141 533 541

a† 5.033 5.090 6.093 6.653 6.843 7.403

b† 4.133 4.190 5.193 5.753 5.193 5.753

c 1.270 1.675 2.295 2.800 2.295 2.800

d 1.921 2.468 3.140 3.750 3.140 3.750

† These dimensions are approximate and vary with cable size.

1108

STIBOINFO((CRH:66008com:8P:1108)) CH0 7 P - 1 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1109-1 Name: 8P-1109

100: DATE: JAN 19 2006

Time: 6:15:48 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

ARK-trol® Electrical Connectors

csm no.: 100

8P

RPC Circuit Breaking Power Connectors RPE Control Circuit and Power Connectors Dimensions Cord Connector Receptacle Shell Type and Size 317 321 333 341 733 741

a† 5.033 5.090 6.093 6.653 6.843 7.403

b† 4.116 4.173 5.176 5.736 5.176 5.736

c 1.562 1.885 2.625 3.187 2.625 3.187

d 1.812 2.300 3.140 3.730 3.140 3.730

Panel Mounting Methods

Square flanged receptacle

Back Mounting a d e 3⁄16 13⁄8 119⁄32 3⁄16 21⁄32 13⁄4 7⁄32 221⁄32 23⁄8 1⁄4 37⁄32 213⁄16

Shell Size 017 021 033 041

Front Mounting b d 117⁄32 13⁄8 131⁄32 13⁄4 221⁄32 23⁄8 35⁄32 213⁄16

e 3⁄16 3⁄16 -7⁄32 1⁄4

AJ Back Boxes Form C&D C&D E

Size 1, 11⁄4, 11⁄2 2 11⁄2, 2, 21⁄2 3⁄4,

a 57⁄8 57⁄8 8

b 8 8 103⁄4

c 77⁄16 8 97⁄8

d 47⁄8 47⁄8 63⁄4

e 7 7 91⁄2

f 57⁄8 57⁄8 8

a 33⁄8 33⁄8 33⁄8 41⁄4 41⁄4 41⁄4

b 35⁄8 35⁄8 35⁄8 411⁄16 411⁄16 411⁄16

c 23⁄4 23⁄4 23⁄4 411⁄16 411⁄16 411⁄16

d 41⁄4 41⁄4 41⁄4 51⁄4 51⁄4 51⁄4

e 1 1 1 15⁄8 15⁄8 15⁄8

f

g 15° 15° 45°

ARE Back Boxes Form B B B C C C

Size 1⁄2 3⁄4 1 1 11⁄4 11⁄2

27⁄32 27⁄32 31⁄32 15⁄16 1 11⁄16

h dia. 11⁄32 11⁄32 11⁄32 3⁄8 3⁄8 3⁄8

FS/FSC Boxes Hub Series Size 1⁄2 3⁄4 FS 1

a 7⁄8 7⁄8 1

b 5⁄8 3⁄4 7⁄8

c 17⁄8 17⁄8 17⁄8

d 111⁄16 111⁄16 111⁄16

† These dimensions are approximate and vary with cable size.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:8P:1109)) CH0 7 P - 1 7

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1109

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1110-2 Name: Note Page-1110

DATE: JAN 19 2006

Time: 6:15:52 PM Operator: RB

COLOR: CMYK

Notes Page

1110

STIBOINFO((CRH:66008com::1110)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1111-1 Name: 9P-1111

100: DATE: JAN 19 2006

Time: 6:15:53 PM Operator: RB

COLOR: CMYK

TCP: 15001

Special Purpose Ark-trol® Plugs and Receptacles Hazardous

Typedriver Name: TS name

csm no.: 100

9P

Description

Page No.

Application/Selection

1113

Delayed Action RPX ‘‘Time-Slot’’ Series

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9P:1111)) CH0 0 0 0 8 P

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1114-1118

1111

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1112-1 Name: Note Page-1112

DATE: JAN 19 2006

Time: 6:15:53 PM Operator: RB

COLOR: CMYK

Notes Page

1112

STIBOINFO((CRH:66008com::1112)) CH0 3 A - 1 1

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

TCP: 15001

Typedriver Name: TS name csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1113-3 Name: 9P-1113

100: DATE: JAN 19 2006

Time: 6:15:54 PM Operator: RB

Ark-trol® Electrical Connectors RPX ‘‘Time Slot’’ Delayed Action Connectors Hazardous Locations

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Group D* Explosionproof Raintight Dimensions Page 1118

csm no.: 100

9P

Application: RPX ‘‘Time-Slot’’ delayed action connectors are used: ɀ in areas which are hazardous due to the presence of gasoline or gases or vapors of equivalent hazard (comparable to NEC Class I, Group D), where construction and test procedures are required to meet applicable sections of MIL-STD-810E ɀ for connection of devices ranging from simple lighting units, power tools and similar portables requiring only a power circuit to sophisticated control and instrumentation assemblies requiring disconnect

C. Turn plug clamping nut an additional 45° counterclockwise to the release position, thereby effecting delayed action.

Features: The same basic features, described in detail in Section 8P for RPC and RPE connectors, apply to RPX connectors as well and include the following: ɀ High-strength impact extruded aluminum shell parts ɀ ‘‘Tri-Disc’’ insert assemblies ɀ Contacts snap in after termination ɀ Positive polarization ɀ Interchangeability of inserts in each shell size ɀ Grounding contacts, where used, make first and break last ɀ The RPX ‘‘Time-Slot’’ delayed action feature prevents complete withdrawal of the plug in one continuous movement, eliminating the possibility of a circuit-breaking arc occurring in a hazardous area. Details of operation are shown in the illustrations below.

D. Disengage plug and receptacle.

Standard Materials: ɀ Back boxes and adapters – Feraloy® iron alloy ɀ Plug, receptacle and cord connector shells – impact extruded aluminum ɀ Insulation – diallyl phthalate (DAP) ɀ Sealing wafer – silicone rubber ɀ Contacts – hard drawn copper

Standard Finishes: ɀ Feraloy – zinc electroplate and aluminum acrylic paint ɀ Impact extruded aluminum – hard coat anodized ɀ Diallylphthalate – natural (blue) ɀ Silicone rubber – natural (grey)

Options:

A. Turn plug clamping nut counterclockwise 45° to unlock plug.

The following options available for RPC and RPE connectors are also applicable to RPX connectors. For complete details see Section 8P pages 1093 to 1094. ɀ Alternate polarities – ungrounded and grounded connectors ɀ Crimp type contacts ɀ Wire mesh cord grip

Electrical Rating Ranges: ɀ 10, 20, 30 and 60 amperes ɀ 50** to 400 hertz ɀ 250, 480 and 600vac ɀ See listings for specific ratings

Certifications and Compliances: ɀ RPX delayed action connectors have the same physical properties, characteristics and environmental capabilities of RPC and RPE connectors listed in Section 8P. For detailed information on these properties, refer to page 1094 of Section 8P. ɀ In addition to these properties, the ‘‘TimeSlot’’ delayed action feature permits disconnect under full rated load with no possibility of an exposed arc, thus meeting the stringent requirements of Military Specifications MIL-STD-810E

B. Pull to disengage pin and socket contacts, breaking circuit while contacts are still inside the receptacle. Any resulting electrical arc is quenched within the receptacle sockets. * RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to N.E.C. Class I, Group D), where construction and test procedures are required to meet applicable sections of MIL-STD-810E.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9P:1113)) CH0 0 8 P - 1

** For use on systems less than 60 hertz the receptacles, plugs and connectors are for disconnect use only.

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1113

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1114-1 Name: 9P-1114

9P

DATE: JAN 19 2006

Time: 6:15:56 PM Operator: RB

COLOR: CMYK

RPX ‘‘Time-Slot’’ Delayed Action Connectors With Solder Well Terminals 1, Hazardous Areas*

Contact Size

Amps

Volts (VAC)

Shell Size

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Group D* Explosionproof Raintight Dimensions Page 1118

Special Purpose†; ARK-trol Electrical Connectors

Circuit Description

TCP: 15001

Hub Size

Square Flanged Receptacle, Dust Cap and Back Box Cat. No. (For Surface Mounting)2

POWER 20 AMPS Grounded

4w, 5p

#12

20

480

017

3⁄4 1

RPX217-914-S09A-EDSC271 RPX217-914-S09A-EDSC371

Ungrounded

5w, 5p

#12

20

480

017

3⁄4 1

RPX217-914-S08N-EDSC271 RPX217-914-S08N-EDSC371

30 AMPS Grounded

2w, 3p

#10

30

480

017

3⁄4 1

RPX217-914-S02A-EDSC271 RPX217-914-S02A-EDSC371

3w, 4p

#10

30

480

017

3⁄4 1

RPX217-914-S04A-EDSC271 RPX217-914-S04A-EDSC371

4w, 5p

#10

30

480

021

3⁄4 1

RPX221-914-S17A-EDSC271 RPX221-914-S17A-EDSC371

3w, 3p

#10

30

480

017

3⁄4 1

RPX217-914-S01N-EDSC271 RPX217-914-S01N-EDSC371

4w, 4p

#10

30

480

017

3⁄4 1

RPX217-914-S03N-EDSC271 RPX217-914-S03N-EDSC371

5w, 5p

#10

30

480

021

3⁄4 1

RPX221-914-S16N-EDSC271 RPX221-914-S16N-EDSC371

Ungrounded

† For alternate polarizations, see ‘‘Options’’ on page 1113.

* RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to N.E.C. Class I, Group D), where construction and test procedures are required to meet applicable sections of MIL-E-5272C and MIL-E-4970A.

1114

STIBOINFO((CRH:66008com:9P:1114)) CH0 0 8 P - 2

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1115-2 Name: 9P-1115

DATE: JAN 19 2006

Time: 6:15:57 PM Operator: RB

Special Purpose†; ARK-trol Electrical Connectors RPX ‘‘Time-Slot’’ Delayed Action Connectors With Solder Well Terminals Hazardous Areas*

Cable Diameter Range

Cord Connector Cat. No.3

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Group D* Explosionproof Raintight Dimensions Page 1118

csm no.: 100

9P

Plug Cat. No.3 FOOTNOTES:

.250 to .625 .625 to .875

RPX317-160-S09A RPX317-161-S09A

RPX117-150-P09A RPX117-151-P09A

.250 to .625 .625 to .875

RPX317-160-S08N RPX317-161-S08N

RPX117-150-P08N RPX117-151-P08N

.250 to .625 .625 to .875

RPX317-160-S02A RPX317-161-S02A

RPX117-150-P02A RPX117-151-P02A

.250 to .625 .625 to .875

RPX317-160-S04A RPX317-161-S04A

RPX117-150-P04A RPX117-151-P04A

.625 to 1.000 1.000 to 1.187

RPX321-161-S17A RPX321-395-S17A

RPX121-151-P17A RPX121-387-P17A

.250 to .625 .625 to .875

RPX317-160-S01N RPX317-161-S01N

RPX117-150-P01N RPX117-151-P01N

.250 to .625 .625 to .875

RPX317-160-S03N RPX317-161-S03N

RPX117-150-P03N RPX117-151-P03N

.625 to 1.000 1.000 to 1.187

RPX321-161-S16N RPX321-395-S16N

RPX121-151-P16N RPX121-387-P16N

1 Solder well terminals provided as standard. Crimp contacts are optionally available, add suffix T to catalog number. Example: RPX217-914-S09AT-EDSC271. 2 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 914 to 913. Example: RPX217-913-S09A-EDSC271. 3 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to first section of catalog number. Example: RPXLT317-160-S09A. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of catalog number. Example: RPXK317-160-S09A.

* RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to N.E.C. Class I, Group D), where construction and test procedures are required to meet applicable sections of MIL-E-5272C and MIL-E-4970A.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9P:1115)) CH0 0 8 P - 3

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1115

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

JOB: CRMAIN06-1116-1 Name: 9P-1116

9P

100: DATE: JAN 19 2006

Time: 6:15:57 PM Operator: RB

COLOR: CMYK

TCP: 15001

Special Purpose†; ARK-trol Electrical Connectors RPX ‘‘Time-Slot’’ Delayed Action Connectors With Solder Well Terminals 1 Hazardous Areas*

Circuit Description 60 AMPS Grounded

Ungrounded

CONTROL

Hub Size

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Group D* Explosionproof Raintight Dimensions Page 1118

Square Flanged Receptacle, Dust Cap and Back Box Cat. No. (For Surface Mounting) 2

Contact Size

Amps

Volts (VAC)

Shell Size

3w, 4p

#4

60

600

033

11⁄4

RPX233-914-S08A-CES42

4w, 5p

#4

60

480

033

11⁄4

RPX233-914-S09A-CES42

4w, 4p

#4

60

600

033

11⁄4

RPX233-914-S05N-CES42

5w, 5p

#4

60

480

033

11⁄4

RPX233-914-S06N-CES42

6w, 7p

#12

20

480

017

3⁄4 1

RPX217-914-S06A-EDSC271 RPX217-914-S06A-EDSC371

7w, 7p

#12

20

480

017

3⁄4 1

RPX217-914-S05N-EDSC271 RPX217-914-S05N-EDSC371

18w, 19p

#12

20

250

021

3⁄4 1

RPX221-914-S08A-EDSC271 RPX221-914-S08A-EDSC371

19w, 19p

#12

20

250

021

3⁄4 1

RPX221-914-S09N-EDSC271 RPX221-914-S09N-EDSC371

38w, 39p

#12

20

250

033

11⁄4

RPX233-914-S19A-CES42

39w, 39p

#12

20

250

033

11⁄4

RPX233-914-S17N-CES42

† For alternate polarizations, see ‘‘Options’’ on page 1113.

* RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to N.E.C. Class I, Group D), where construction and test procedures are required to meet applicable sections of MIL-E-5272C and MIL-E-4970A.

1116

STIBOINFO((CRH:66008com:9P:1116)) CH0 0 8 P - 4

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1117-2 Name: 9P-1117

DATE: JAN 19 2006

Time: 6:15:58 PM Operator: RB

Special Purpose†; ARK-trol Electrical Connectors RPX ‘‘Time-Slot’’ Delayed Action Connectors With Solder Well Terminals Hazardous Areas*

Cable Diameter Range

Cord Connector Cat. No.3

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

Cl. I, Div. 1 & 2, Group D* Explosionproof Raintight Dimensions page 1118

csm no.: 100

9P

Plug Cat. No.3 FOOTNOTES:

.875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPX333-163-S08A RPX333-396-S08A RPX333-397-S08A

RPX133-153-P08A RPX133-388-P08A RPX133-389-P08A

.875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPX333-163-S09A RPX333-396-S09A RPX333-397-S09A

RPX133-153-P09A RPX133-388-P09A RPX133-389-P09A

.875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPX333-163-S05N RPX333-396-S05N RPX333-397-S05N

RPX133-153-P05N RPX133-388-P05N RPX133-389-P05N

.875 to 1.375 1.375 to 1.625 1.625 to 1.875

RPX333-163-S06N RPX333-396-S06N RPX333-397-S06N

RPX133-153-P06N RPX133-388-P06N RPX133-389-P06N

.250 to .625 .625 to .875

RPX317-160-S06A RPX317-161-S06A

RPX117-150-P06A RPX117-151-P06A

.250 to .625 .625 to .875

RPX317-160-S05N RPX317-161-S05N

RPX117-150-P05N RPX117-151-P05N

.625 to 1.000 1.000 to 1.187

RPX321-161-S08A RPX321-395-S08A

RPX121-151-P08A RPX121-387-P08A

.625 to 1.000 1.000 to 1.187

RPX321-161-S09N RPX321-395-S09N

RPX121-151-P09N RPX121-387-P09N

.875 to 1.375 1.375 to 1.625

RPX333-163-S19A RPX333-396-S19A

RPX133-153-P19A RPX133-388-P19A

.875 to 1.375 1.375 to 1.625

RPX333-163-S17N RPX333-396-S17N

RPX133-153-P17N RPX133-388-P17N

1 Solder well terminals provided as standard. Crimp contacts are optionally available, add suffix T to catalog number. Example: RPX217-914-S09AT-EDSC271. 2 For square flanged receptacle without dust cap, change the middle three digits of the catalog number from 914 to 913. Example: RPX217-913-S09A-EDSC271. 3 For plugs and cord connectors: LIQUIDTIGHT/CONDUIT ADAPTER – To order with adapter, add letters ‘‘LT’’ to first section of catalog number. Example: RPXLT317-160-S09A. ADDITIONAL CABLE STRAIN RELIEF OPTIONS – ɀ Stainless steel wire mesh grip – To order, add letter ‘‘K’’ to first section of catalog number. Example: RPXK317-160-S09A.

* RPX series are suitable for hazardous areas due to the presence of gasoline or other gases or vapors of equivalent hazard (comparable to N.E.C. Class I, Group D), where construction and test procedures are required to meet applicable sections of MIL-E-5272C and MIL-E-4970A.

US: 1-866-764-5454

STIBOINFO((CRH:66008com:9P:1117)) CH0 0 8 P - 5

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

1117

Zoom: 100

2:

5:

SYS19: BASE2

PDFINFO

50:

95:

98:

100:

JOB: CRMAIN06-1118-1 Name: 9P-1118

DATE: JAN 19 2006

Time: 6:15:59 PM Operator: RB

COLOR: CMYK

TCP: 15001

Typedriver Name: TS name

ARK-trol® Electrical Connectors

9P

RPX ‘‘Time-Slot’’ Delayed Action Connectors

Dimensions RPX Cord Connector Receptacle

Cord Connector Receptacle Shell Type and Size 317 321 333

a‡ 5.033 5.090 6.093

b‡ 4.116 4.173 5.176

c 1.560 2.000 2.625

CES42ɍ

CES42ɍ d 1.812 2.300 3.140

RPX Plug

Size 11⁄4

a 51⁄4

b 51⁄4

c 311⁄16

d 43⁄8

e 7⁄16

RPX Connectors Square Flanged Receptacle with Dust Cap

f 51⁄4

h dia. 7⁄16

j 11⁄8

k 27⁄8

Back Boxes



RPX Plug

RPX Connectors Square Flanged Receptacle with Dust Cap

Shell Type and Size 117 121 133

Shell Type and Size 217 221 233

a‡ 5.033 5.090 6.093

b‡ 4.133 4.190 5.193

c 1.270 1.675 2.295

d 1.921 2.468 3.140

a .190 .190 .214

b 1.375 1.750 2.375

c 1.317 1.692 2.317

d 1.750 2.250 2.875

Back Boxes

Cat. No. EDSC271 EDSC371

h

l

7⁄8

13⁄16

1

15⁄16

† Dimension ‘‘f’’; 0.1875 for #16, #12 and #10 contacts 0.250 for #4 contacts

‡ These dimensions are approximate and vary with cable size. ɍ CES42 takes 60 ampere receptacle housings.

1118

STIBOINFO((CRH:66008com:9P:1118)) CH0 0 8 P - 6

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2006 Cooper Crouse-Hinds

csm no.: 100

Zoom: 100

Recommend Documents
Consult your local electrical codes before installation. ** Cooper Crouse-Hinds recommends circuit breaking use be limited to emergency conditions only and that a horsepower rated switch or Cooper Crouse-Hinds. Interlocked Receptacle be used for maki

complete technical information on the Cooper. Crouse-Hinds ... metal shelled units makes contact with detent springs of ..... conductors and external cable jacket.

it is possible to use the same standard plug with a number of ...... –80°F to 275°F, meeting requirements of MIL-STD-810E. Air leakage ...... see page 1553.

German-North American precision engineering and manufacturing ..... (NEMA 4). All aluminum Uni-Shell™ construction .... Leaded red brass – electro-tin-plate.

The Plugs and Receptacles Section of the. Cooper Crouse-Hinds Product Catalog contains complete technical information on the Cooper. Crouse-Hinds line of these products. In addition to product listings and features, the section contains information o

applications up to 20 amperes. This offering now includes the Ark•Gard Premier line of receptacles and connectors that are rated NEMA. 4 watertight while not in ...

German-North American precision engineering ..... (NEMA 4). 8 All aluminum Uni-Shell™ construction provides .... screw – brass; crimp/solder 20, 30, 60,.

Check National Electrical Code for proper wire size and application ..... Square D is a registered trademark of Schneider Electric. ..... APC Cable Connector.

German-North American precision engineering .... Plugs and Receptacles. Interlock Selection Guide. Cast. Aluminum. Painted. Sheet. Metal ..... Brass – natural.

UL04 – 5V Flame Rating. Standard Materials. • Enclosure: VALOX® * thermoplastic polyester with seamless ...... 2 Gang. EFD-2-NL. 3 Gang. EFD-3-NL. 4 Gang. EFD-4-NL. 5 Gang. EFD-5-NL. † For tandem bodies, eternal seals must be installed within