Signature

Report 10 Downloads 1629 Views

and Reverse Shoulder Systems. Product ... Data on file at Biomet. Bench testing is ... The Signature™ Glenoid system is a patient-specific surgical positioning ...

Multiple Targets. Same Results. Signature™ Personalized Patient Care for Comprehensive Total and Reverse Shoulder Systems

Product Brochure

Anatomic Trajectory Reverse Trajectory

Patient-matched bone model

SPECIFICALLY CREATED FOR YOUR PATIENTS With each patient-specific Signature™ guide, the surgeon will receive a bone model created from each patients’ unique anatomy. The bone model allows for preoperative surgeon evaluation and intraoperative verification.

THE SIGNATURE™ GLENOID SYSTEM

Thumb Pressure Point for guide registration

Multiple Targets. Same Results.

SURGEON DESIGNED. PATIENT MATCHED. The Signature™ Glenoid system is a patient-specific surgical positioning guide which offers a unique and tailored approach to shoulder arthroplasty. Using three dimensional CT imaging technology, these guides are created and based upon each patients’ unique anatomy, offering personalized patient care and pin-point accuracy for both anatomic and reverse shoulder arthroplasty.

DEMONSTRATED RESULTS1

-1.6 degrees

0.9 degrees

1.4

Average Version

Average Inclination

Average Insertion Point

milimeters

*negative reflects retroversion, positive reflects superior tilt ** Data on file at Biomet. Bench testing is not necessarily indicative of clinical performance.

Multiple Targets. Same Results.

INTERACTIVE PREOPERATIVE PLANNING • Patient-specific images are featured for both anatomic and reverse procedures. • The planning suite details the suggested position, orientation and size of each implant. • Preoperative changes can be made by the surgeon and updated by the Biomet Signature™ team to create a customized plan for every patient.

the indicated trajectory. Please review the trajectories and indicate any changes before approving and submitting to Biomet. Based on the CT scan provided, the below data and implant sizes were determined:

Anatomic Shoulder Arthroplasty The glenoid guide will be used to place the Steinmann pin for Anatomical Shoulder Arthroplasty. WARNING: Implant size overhangs glenoid fossa and perforates the glenoid vault

Glenoid Fossa View

Coronal View LG

Implant Size: Planned

Adjustment

A/P Shift (mm):

0

0

I/S Shift (mm):

0

0

Version Adj (°):

0

0

Inclination Adj (°):

0

0

Transverse View

Anatomic Plan Reverse Shoulder Arthroplasty The glenoid guide will be used to place the Steinmann pin for Reverse Shoulder Arthroplasty. Patient ID: LWNielso-0730LSA-JWS

Glenoid Fossa View

Coronal View 25mm

Baseplate Size:

20mm

Central Screw Size: Planned

Adjustment

A/P Shift (mm):

0

0

I/S Shift (mm):

0

0

Version Adj (°):

0

0

Inclination Adj (°):

0

0

Transverse View

Reverse Plan

Signature Personalized Patient Care Approval Summary

LWNielso-0730LSA-JWS

Patient ID:

Surgery Date:

2013-Dec-27

Reverse LG

Implant Size:

Left

Operative Side:

Anatomic

25mm

Baseplate Size:

20mm

Central Screw Size: Planned

Adjustment

Approved

A/P Shift (mm):

0

0

0

I/S Shift (mm):

0

0

Version (°):

0

Inclination (°):

0

Planned

Adjustment

Approved

A/P Shift (mm):

0

0

0

0

I/S Shift (mm):

0

0

0

0

0

Version (°):

0

0

0

0

0

Inclination (°):

0

0

0

All trademarks herein are the property of Biomet, Inc. or its subsidiaries unless otherwise indicated. •

This material is intended for the Biomet Sales force and physicians only and is NOT intended for patient distribution. It is not to be redistributed, duplicated or disclosed without the expressed written consent of Biomet.



For product information, including indications, contraindications, warnings, precautions and potential adverse effects, see the package insert and Biometʼs website.

The Signature guide does not control ream depth. The TSA glenoid implant, reverse TSA baseplate, and central screw are shown at an estimated ream depth along the indicated trajectory. The final decision regarding ream depth must be made at the time of surgery.

LET SIGNATURE™ GUIDE YOU

Glenoid Sizer Low-profile design facilitates insertion into the joint, allowing for visualization and accurate placement

ACCESS GLENOID INSTRUMENTATION

Multiple Targets. Same Results. STREAMLINED 4-STEP APPROACH Cannulated, compact and low-profile, the Comprehensive Access glenoid instruments are designed to simplify glenoid preparation, while providing surgeons unmatched visibility to the joint.

Peripheral Peg Guide The hex-shaped quick connection provides multiple handle placement options

2-in-1 Regenerex Post Reamer Prepares the glenoid boss and post in one simple motion

Glenoid Reamer Reduced geometry reamer for improved visualization and easy entry into the joint

REDUCING COMPLEXITY WITH IMPROVED DESIGN Eliminate the need for anti-rotation pegs. The quick-connect drill bits attach magnetically, streamlining peripheral peg preparation.

All trademarks herein are the property of Biomet, Inc. or its subsidiaries unless otherwise indicated. This material is intended for the sole use and benefit of the Biomet sales force and physicians. It is not to be redistributed, duplicated or disclosed without the express written consent of Biomet. For full prescribing information, including indications, contraindications, warnings, precautions and potential adverse effects, see the package insert herein and Biomet’s website. 1. Pietrzak, William S., Ph.D. “Shoulder Alignment Obtained with the Signature™ Glenoid Guide System: A Cadaver Study.” (2013)

Responsible Manufacturer Biomet, Inc. P.O. Box 587 56 E. Bell Drive Warsaw, Indiana 46581-0587 USA ©2013 Biomet Orthopedics • Form No. BMET0851.0 • REV123013

www.biomet.com

Recommend Documents
Signature. Signature*. Print or Type Name. Print or Type ... Number / email address. Date. Date*. (Revised Aug. 2014). *Valid for one calendar year after signature*

May 14, 2015 - Encapsulation of CDN in PEGylated liposomes enhanced its ... Thank you for always expecting the best out of me, for teaching me little ...

May 17, 1991 - The cost accounting system at Boeing does not emphasize flow time, the time ..... the Boeing 767 final assembly process at Boeing's Everett, ...

Anatomic Plan. WARNING: Implant size overhangs glenoid fossa and perforates the glenoid vault. Glenoid Fossa View. Coronal View. Implant Size: LG. Planned.

Data on file at Biomet. Bench testing is not necessarily indicative of clinical performance. SURGEON DESIGNED. PATIENT MATCHED. The Signature™ Glenoid ...

... are registered trademarks of Société des Produits Nestlé S.A., Vevey, Switzerland. M&M's®/ ™ Brand Milk Chocolate trademarks ©Mars, Incorporated 2016.

MazdaMX-5 Miata. CAN NUMBERS TRULY CAPTURE. HOW RIGHT A CAR FEELS IN YOUR HANDS? • DRIVETRAIN TYPE: REAR-WHEEL DRIVE (RWD) ...

SIENNA. L VAN. TUNDRA SR. RAV4 LE. 2 0 1 6 T O Y O T A. COROLLA L. 2 0 1 6 T O Y O T A. VIEW INVENTORY. > VIEW INVENTORY. > VIEW INVENTORY.

steaknshakesignature.com 08/04/2015 Tempe - WEB. We've made our shakes the same way since 1934. They're hand-dipped into stainless steel containers, ...

Columbia Center. 701 5th Avenue. Seattle, WA 98104-7097. PON Number. THIS AGREEMENT, made and entered into this date by and between COLUMBIA CENTER PROPERY LLC whose address is: 200 STATE STREET, SUITE 4000. BOSTON, MA 02109-2628 hereinafter called t