Inductive sensor
NBB15-30GM50-E2-M-150MM-3DT04 Dimensions
50 47 A BN (+)
M30 x 1.5
LED
B BU (–)
5
36
X (see note)
C BK
Model Number NBB15-30GM50-E2-M-150MM-3DT04 Mobile Equipment Series
Technical Data
Features • • •
15 mm flush Increased operating distance Extended temperature range 40 ... +85 °C 3-pin Deutsch connector (DT04) 100 V/m radiated field immunity
• •
Connection BN
L+
BK BU
L-
Wire colors A B C
BN BU BK
General specifications Switching element function Rated operating distance sn Installation Output polarity Assured operating distance sa Reduction factor rAl Reduction factor rCu Reduction factor r304 Nominal ratings Operating voltage UB Switching frequency f Hysteresis H Reverse polarity protection Short-circuit protection Voltage drop Ud Operating current IL Off-state current Ir No-load supply current I0 Indication of the switching state Functional safety related parameters MTTFd Mission Time (TM) Diagnostic Coverage (DC) Ambient conditions Ambient temperature Mechanical specifications Connection type Core cross-section Housing material Sensing face Protection degree Note Compliance with standards and directives Standard conformity Standards
PNP NO 15 mm flush DC 0 ... 12.15 mm 0.45 0.4 0.7 5 ... 60 V 0 ... 200 Hz typ. 5 % yes yes ≤ 2.5 V 0 ... 200 mA 0 ... 0.5 mA typ. 0.1 µA at 25 °C ≤ 10 mA LED : yellow output 1260 a 20 a 0% -40 ... 85 °C (-40 ... 185 °F) Cable connector Deutsch DT04 , 3-pin with PUR cable 150 mm 0.75 mm2 brass, nickel-plated PBT IP68 / IP69K X = 150 mm
EN 60947-5-2:2007 IEC 60947-5-2:2007
UL approval e1 Type approval
cULus Listed, General Purpose 2006/28/EG
Release date: 2012-11-15 11:58 Date of issue: 2012-11-15
912896_eng.xml
Approvals and certificates
Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com
[email protected] Germany: +49 621 776-4411
[email protected] Copyright Pepperl+Fuchs Singapore: +65 6779 9091
[email protected] 1
Inductive sensor
NBB15-30GM50-E2-M-150MM-3DT04
Installation hint Emitted interference and interference immunity in accordance with motor vehicle directive 2006/28/EG (e1 Type approval) Interference immunity in accordance with DIN ISO 11452-2: 100 V/m Frequency band 20 MHz up to 2 GHz
Mains-borne interference in accordance with ISO 7637-2: Pulse 1 2a 2b 3 a 3b 4 5 Severity level III III III III III III IV Failure criterion C A C A A A C CD: 8 kV / AD: 15 kV IV IV 30 V/m (80...2500 MHz) IV 2 kV III 10 V (0.01...80 MHz) III Class A
Release date: 2012-11-15 11:58
Date of issue: 2012-11-15 912896_eng.xml
EN 61000-4-2: Severity level EN 61000-4-3: Severity level EN 61000-4-4: Severity level EN 61000-4-6: Severity level EN 55011:
2
Subject to modifications without notice Pepperl+Fuchs Group USA: +1 330 486 0001 www.pepperl-fuchs.com
[email protected] Germany: +49 621 776-4411
[email protected] Copyright Pepperl+Fuchs Singapore: +65 6779 9091
[email protected]