101XBRM Series Instructions - Edwards Signaling

Report 6 Downloads 67 Views
7 3/4” (197 mm) 3 lbs (1.4 kg)

11 3/8” (289 mm) 4 lbs (1.8 kg)

15” (381 mm) 5 lbs (2.3 kg)

18 5/8” (473 mm) 6 lbs (2.7 kg)

22 1/4” (565 mm) 7 lbs (3.2 kg)

Figure 1. Dimensions

Description

PLC Compatibility

Edwards AdaptaLight Series 101XBRM Stackable Beacon is a unique signaling appliance which can contain up to five modules, stacked onto a single AdaptaLight Base Unit (as illustrated above). The 101XBRM series can be combined or stacked with any of the models shown in Table 2 only if modules have same input voltage. The 101XBRM LED Series is supplied in steady-on mode but offers a field-selectable 65 fpm flash mode. Up to five modules can be used in any position in the AdaptaLight Stackable Beacon. The AdaptaLight base unit (101BS) contains a mini pulsating horn rated 85 dB at 10 feet (3.05 m). This horn can operate as a sixth independent signal or with any one of the stacked modules shown in Table 2. The base unit has a screw-type terminal strip for positive hard wiring. Each module in the stack is electrically interconnected through solid copper busses and mating contacts to withstand vibration. Each is positively connected to the one below it by a solid throughbolt for mechanical integrity.

The electrical input load requirements for PLC compatible signaling devices are listed in Table 1. Signaling devices may be directly connected to output cards that meet these input load requirements. Unit is PLC compatible only when in steady mode.

Installation WARNING To prevent electrical shock, do not connect power until instructed to do so. This equipment must be installed by a qualified electrician in accordance with the latest edition of the National Electrical Code and applicable local codes. 1. Mount the base vertically either facing up or down using one of the following procedures (Figures 2 and 3).

AdaptaLight is UL and cUL listed for direct surface or pipe mounting in non-hazardous dust and outdoor applications. The AdaptaLight may be mounted vertically with lenses facing up or with lenses facing down (on ceiling). The AdaptaLight is not suitable for outdoor installations when mounted with the lenses facing down. The AdaptaLight must never be mounted horizontally. Assemble and install in accordance with these instructions.

NOTE: For indoor applications, the base may be direct surface mounted, mounted on a 4" (102 mm) octagon box, or mounted on 1/2" NPT conduit. For outdoor (weatherproof) applications, the base must be conduit mounted vertically facing up.

The AdaptaLight modules have double fresnel polycarbonate lenses available in a variety of colors, each providing a 360° non-shadowed light pattern.

NOTE: A permanently affixed gasket is supplied on the base. Use care when handling the base unit to prevent tearing of the gasket.

a. Loosen the screw in the clamp ring, remove ring and set aside.

Mechanical Specifications Outdoor Locations Temperature Ratings............ -31F to +150F (-35C to +66C) http://www.edwardssignaling.com Phone: (800) 336-4206 Fax: (800) 454-2363

P/N 3101631 ISSUE 3 © 2010

Table 1. PLC Compatibility Cat. No.

Operating voltage*

101BS-G1 24V DC 101BS-N5 120V AC 101XBRM( )24D 24V DC 101XBRM( )120A 120V AC *All AC volts at 50/60 Hz

Maximum off state leakage current (mA)

Continuous on current (mA)

Surge (inrush/duration)

1.2 25 5 5

20 50 215 108

2/1 A/millisecond 2/1 A/millisecond 34.5/52 A/microsecond 37.5/164 A/microsecond

b. Direct Surface Mounting (indoor installation only)



Continue adding modules in this manner as required.



Remove the two knockouts from the bottom of the base.





Fasten the base to the surface using suitable hardware (not supplied).

Place the cap supplied with the base unit onto the top module ensuring the gasket is in place. Secure with an o-ring and 3/8" (9.5 mm) cap screw (supplied).

c. 4" (102 mm) Octagon Box Mounting (indoor installation only)

Remove the two knockouts from the bottom of the base. Fasten the base to the octagon box (not supplied) by installing the screws (supplied with the box) through the knockout holes in the base.

d. Conduit Mounting (indoor or outdoor installation)

Install a 1/2" NPT conduit (not supplied). Align the conduit entrance hole on the base with the conduit and rotate base until base is tightly secured.

2. Route incoming field wiring into the base through the conduit entrance hole.

Up to five 101XBRM LED modules or any other modules shown in Table 2 can be used in any position in the stack. The terminal block labels, 1 through 5, correspond to the stacked modules with 1 being the bottom module on the stack.



Connect field wiring to the terminal block as shown in Figure 4.



Ground the AC AdaptaLights to the grounding screw (Figure 3) in accordance with applicable codes. Place the connected wires inside of the base.

4. Turn on power and verify that module(s) and horn are operating properly.

Maintenance/Flash Pattern Change Refer to "Specifications" for replacement parts.

WARNING To prevent electrical shock, disconnect all power before starting work on unit. 1. Remove the 3/8" (9.5 mm) cap screw, o-ring and cap from top of unit. 2. Remove the #8-32 x 3/8" (9.5 mm) plastic panhead screw from the side of the module lens. 3. Loosen the slotted panhead through-bolt (on top module). Do not remove the through-bolt from the module; turn the bolt approximately 30 turns. 4. Carefully remove the module and gasket. 5. Continue to disassemble until the internal dipswitch on the top circuit is reached or the component to be replaced is located. To change the flash pattern, set the dipswitch as illustrated in Figure 6. To replace the pulsating horn, follow instructions shown below. 6. Replace mini pulsating horn.

Assemble the base unit and place the base gasket on top as shown in Figure 2.

a. Remove the screw in the clamp ring, remove ring and set aside.

3. To stack the modules, align the notch on the bottom of the first module with the notch on the base and press into position. Secure by tightening the slotted panhead through-bolt located on the top of the module.

b. Remove three phillips head screws from top of base skirt and the base/horn assembly from the top portion of the base (Figure 2).



NOTE: Never try to remove the through-bolt from the module.

Install the #8-32 x 3/8" (9.5 mm) plastic panhead screw in the side of the module lens (Figure 5).



Place gasket supplied with module onto the top of the module.

P/N 3101631 ISSUE 3

c. Remove the phillips head screw securing the horn to the mounting bracket (Figure 2). d. Disconnect wires by cutting off the wire crimp connectors. e. Secure the new horn on the mounting bracket with the screw removed in step 6.c. f. Connect wires using wire nuts (not supplied).

Gasket

Base Skirt

Base/horn assembly

NOTE: It is not necessary to disassemble this portion of the unit for installation.

Terminal Block Horn Top Portion

Base Unit

Bottom Portion

Clamp ring

#12 x 7/8” Phillips head screw

Figure 2. Catalog Series 101BS AdaptaLight Base Unit Assembly

Pipe Mounting

Direct Surface Mounting (with or without 4" octagonal back box) Grounding Screw

Grounding Screw

Conduit mount entrance hole 1/2” NPT Conduit (Not supplied)

(2) Knockouts for Direct Surface Mounting

Figure 3. Mounting the Catalog Series 101BS AdaptaLight Base Unit

P/N 3101631 ISSUE 3

Cleaning The AdaptaLight module lens surfaces should be periodically dusted and cleaned with a dry soft clean cloth to maintain optimum light visibility. If necessary, the outer lenses may be cleaned with water and a mild detergent on a well rung out soft clean cloth.

Steady-On Incandescent Light Unit* 120V AC

12V DC

24V DC

Lens Color

101SINHR-N5

101SINR-E1

101SINHR-G1

Red

101SINHA-N5

101SINA-E1

101SINHA-G1

Amber

101SINHB-N5

101SINB-E1

101SINHB-G1

Blue

101SINHG-N5

101SING-E1

101SINHG-G1

Green

101SINHM-N5

101SINM-E1

101SINHM-G1

Magenta

101SINHC-N5

101SINC-E1

101SINHC-G1

Clear

101XBRM LED Units 120V AC

12V DC

24V DC

Lens Color

101XBRMR120A

--

101XBRMR24D

Red

101XBRMA120A

--

101XBRMA24D

Amber

101XBRMB120A

--

101XBRMB24D

Blue

101XBRG120A

--

101XBRMG24D

Green

--

101XBRMW24D

White

101XBRMW120A

Flashing Incandescent Light Unit* 120V AC

12V DC

24V DC

Lens Color

101FINHR-N5

101FINR-E1

101FINHR-G1

Red

101FINHA-N5

101FINA-E1

101FINHA-G1

Amber

101FINHB-N5

101FINB-E1

101FINHB-G1

Blue

101FINHG-N5

101FING-E1

101FINHG-G1

Green

101FINHM-N5

101FINM-E1

101FINHM-G1

Magenta

101FINHC-N5

101FINC-E1

101FINHC-G1

Clear

Flashing Strobe Light Unit 120V AC

12V DC

24V DC

Lens Color

101STR-N5

101STR-E1

101STR-G1

Red

101STA-N5

101STA-E1

101STA-G1

Amber

101STB-N5

101STB-E1

101STB-G1

Blue

101STG-N5

101STG-E1

101STG-G1

Green

101STM-N5

101STM-E1

101STM-G1

Magenta

101STC-N5

101STC-E1

101STC-G1

Clear

*H in catalog number (e.g., 101SINHR-N5) signifies halogen module.

Table 2. Stackable Light Units Available

P/N 3101631 ISSUE 3

Factory installed copper conductors from terminals 1 thru 5 to contact points.

Factory installed horn wire leads.

#6 x 3/8” Cap screw Supplied with Base Unit

Gasket Cap

Cap screw or through-bolt entrance hole

Green insulated ground lead from 120V AC Adaptalight.

Align notches for assembly Gasket

Typical actuating contact (by others).

Contacts

(+) for DC, Hot (line) for AC

Slotted panhead through-bolt (Do not remove) #8-32 x 3/8” Plastic panhead screw

Connection to installation ground

(-) for DC, COM for AC

Module

Figure 4. Wiring to the Terminal Block Gasket

Base Unit

Figure 5. Stacking the Modules on AdaptaLight Base Unit

STEADY (FACTORY DEFAULT)

OFF

1

OFF

1

ON

OFF

2

ON STEADY

ON

OFF

1

OFF

2

ON ON 65 FPM

OFF

2

ON

Figure 6. Dipswitch Settings Table 3. Specifications Catalog Number Voltage Current Sound Output

Median LED Life (L70)

Light Output

101BS-N5 101BS-G1

120V 50/60 Hz 0.05A 85 dB at 10 ft. (3.05 m) -- __ 24V DC

101XBRM*120A 101XBRM*24D

120V 50/60 Hz 24V DC

0.108A 0.215A

-- --

Replacement Horn 123A-N5 need new number

148,000 hr.† 148,000 hr.†

*Letter in this position specifies lens and LED color: A - amber, B - blue, G - green, R - red or W - white (lens is clear with white LEDs). † Based on LED manufacturer's projections. Refer to http://www.philipslumileds.com/pdfs/WP15.pdf. P/N 3101631 ISSUE 3