FOR SUBLEASE “B” CLASS OFFICE SPACE
1177 WEST HASTINGS STREET SUITE 2288
VANCOUVER | BRITISH COLUMBIA
MOUNTAIN & WATER VIEW
PROPERTY SUMMARY 1177 West Hastings Street is a Class B Downtown office tower with excellent views of the Burrard Inlet and the North Shore. It has a bike room, showers, and available secure underground parking. The building is located a short distance from Waterfront and Burrard SkyTrain transit hubs, Convention Centre, hotels and the Financial Core. Many amenities are within a short walking distance including trendy restaurants, hotels, high-end retailers, banks, and much more. AVAILABLE AREA
Suite 2288 - 4,799 sq. ft.
SUBLEASE RATE
Contact Listing Agent for details
OP. COSTS & TAXES
$19.49 per sq. ft. (2017 estimate)
DATE AVAILABLE
May, 2017
PARKING
1 stall per 1,000 sq. ft. leased
SUBLEASE TERM
Until February, 2018
FURNITURE
Available
VIEWS
Unobstructed north-facing waterfront and mountain views, east-facing architectural views
FOR MORE INFORMATION CONTACT Perry Gorgounis +1 604 662 5133
[email protected] CBRE Limited | 1021 West Hastings Street #2500 | Vancouver, BC V6E 0C3 | www.cbre.ca
NORTH VIEW
EAST VIEW
++ PRIVATE WASHROOM ++ BEAUTIFUL RECEPTION ++ FURNITURE INCLUDED
FOR SUBLEASE “B” CLASS OFFICE SPACE
FOR MORE INFORMATION CONTACT
SUITE 2288
Perry Gorgounis
VANCOUVER | BRITISH COLUMBIA
+1 604 662 5133
[email protected] 1177 WEST HASTINGS STREET SUITE 2288 PHOTOS
FLOOR PLAN W CORDOVA STREET: Water & Mountain Views
ELECTRICAL SCHEDULE SYMBOL N
SC
DESCRIPTION NEW DUPLEX ELECTRICAL OUTLET TO BE MOUNTED @ 14" A.F.F. NEW DUPLEX ELECTRICAL OUTLET C/W SEPARATE CIRCUIT TO BE MOUNTED @ 14" A.F.F. E
NEW FOURPLEX OUTLET TO BE MOUNTED @ 14" A.F.F.
NEW BOARDROOM 30'10" X 15'4"
N
NEW TELEPHONE AND DATA TO BE CAT5E, OUTLET TO BE MOUNTED @ 14" A.F.F.
N EXISTING OFFICE 10' X 15'4"
T
EXISTING STAFF RM. 15'2" X 10'
EXISTING OFFICE 10'2" X 10'
Architectural Views
4.7 4.8 4.9 4.10
NEW OFFICE 15'2" X 10'
4.11 4.12 4.13 4.14 4.15
RECEPTION AREA 15'2" X 15'2" EXISTING OFFICE 10'2" X 15'2"
Electrical installation shall be in accordance with the current edition of C.E.C. and local code. Examine site and existing conditions prior to bidding. Ensure existing building panel's has sufficient room to accommodate new circuits. All power, telephone and data outlets to be ganged on one stud or horizontal bar when they are indicated in close proximity; use combination faceplates where possible. Provide as-built drawings upon completion. All redundant non-plenum rated cabling to be removed and terminated. Wall mounted outlets to be mounted vertically at 12" o.c. above slab unless otherwise noted on drawings. All power, data, and switches that are located in close proximity to be ganged together and multi-face plates used where possible. Do not mount wall outlets back to back; stagger to prevent sound transfer. All telephone amphenols to be concealed within junction box. Obtain final certificate of inspection and approval from electrical inspection department. Workmanship and materials to be guaranteed for one year from sub-completion for any mechanical defects. All data and communications conduits are to have mud ring and pull string. This drawing is to be read in conjunction with issued Consultant's drawings, if applicable. All new or existing penetrations through slabs and fire walls to be fire stopped with Code approved fire caulking. Provide manufacturers literature to Project Manager. All new and existing cover plates to be Decora White, unless otherwise noted. Outlet locations to be approved on site by Designer @ framing stage.
N
++Large executive office with water and mountain views
4.4 4.5 4.6
EXISTING OFFICE 15'2" X 10'
++3 core regular sized offices
EXISTING THERMOSTAT
++Glass door reception area with seating
4.0 4.1 4.2 4.3
EXISTING OFFICE 10'2" X 10'
EXISTING W/C 7'7" X 6'6"
E
E
++Private washroom
N
EXISTING SEVER RM. 10' X 11'
E
N
EXISTING OFFICE 10'2" X 15'2"
E
NEW DATA OUTLET TO BE CAT5E, TO BE MOUNTED @ 14" A.F.F. EXISTING THERMOSTATS TO BE REMOVED AND RELOCATED
T
CHAIRMAN'S OFFICE 22'4" X 10'
++8 perimeter regular sized offices with view
NEW ELECTRICAL OUTLET TO BE MOUNTED @ SPECIFIED HEIGHT (TO MATCH EXISTING OUTLETS IN EXISTING COPY RM.)
D
EXISTING OFFICE 10' X 15'4"
CHAIRMAN'S OFFICE 15'2" X 15'4"
N @ HT
++Kitchen/staff room
++Medium sized meeting room
++Large boardroom with water and mountain views ++Storage/server room
NEW MEETING RM. 15'2" X 10'
EXISTING OFFICE 10'2" X 15'2" EXISTING OFFICE 10' X 15'4"
EXISTING OFFICE 15'4" X 10'2"
Not to scale. 1
W HASTINGS STREET
FURNITURE PLAN 1/8" = 1'-0"
This disclaimer shall apply to CBRE Limited, Real Estate Brokerage, and to all other divisions of the Corporation; to include all employees and independent contractors (“CBRE”). The information set out herein, including, without limitation, any projections, images, opinions, assumptions and estimates obtained from third parties (the “Information”) has not been verified by CBRE, and CBRE does not represent, warrant or guarantee the accuracy, correctness and completeness of the Information. CBRE does not accept or assume any responsibility or liability, direct or consequential, for the Information or the recipient’s reliance upon the Information. The recipient of the Information should take such steps as the recipient may deem necessary to verify the Information prior to placing any reliance upon the Information. The Information may change and any property described in the Information may be withdrawn from the market at any time without notice or obligation to the recipient from CBRE. CBRE and the CBRE logo are the service marks of CBRE Limited and/or its affiliated or related companies in other countries. All other marks displayed on this document are the property of their respective owners. All Rights Reserved. Mapping Sources: Canadian Mapping Services
[email protected]; DMTI Spatial, Environics Analytics, Microsoft Bing, Google Earth.
CBRE Limited | 1021 West Hastings Street #2500 | Vancouver, BC V6E 0C3 | www.cbre.ca
1
ELECTRICAL P 1/8" = 1'-0"