2007 Master Catalog Full

Report 0 Downloads 238 Views
BURNDY®

Products

Grounding TYPE YGA HYLUG™ Grounding Irreversible Compression Terminals Irreversible compression HYLUG™ Ground terminal specifically designed for grounding applications. Each connector has an inspection probe hole to insure proper cable insertion. UL467 Listed. Acceptable for direct burial in earth or concrete. UL486A Listed. Prefilled with PENETROX™ compound and strip sealed.

D-17

Fig. 2

Fig. 1

Catalog Number

Installation Tools, Die Set Cat. No., and (number of crimps) Mechanical Hydraulic Y35/Y39/Y45/PAT750 ① Copper Y2MR MD7-34R OUR840 /Y46 ② /Y750 Fig. Conductor Die # (# of Die # (# of Die # (# of Die # (# of No. Size crimps) crimps) crimps) crimps)

YGA8C-TC10

2

8 sol./8 str.

Red (4)

YGA8C-TC14

2

8 sol./8 str.

Red (4)

YGA8C-TC516

2

8 sol./8 str.

Red (4)

YGA8C-2N

1

8 sol./8 str.

Red (4)

YGA6C-TC10

2

6 sol./6 str.

Blue (4)

YGA6C-TC14

2

6 sol./6 str.

Blue (4)

YGA6C-TC516

2

6 sol./6 str.

Blue (4)

YGA6C-2TC38E2G1

1

6 sol./6 str.

Blue (4)

YGA6C-2N

1

6 sol./6 str.

Blue (4)

YGA2C-2TC38

1

2 sol./2 str.

Brown (4)

YGA2C-2TC38E2G1

1

2 sol./2 str.

Brown (4)

YGA2C-2N

1

2 str.

Brown (4)

YGA25-2N

1

1/0 str.



YGA26-2N

1

2/0 str.



YGA28-2N

1

4/0 str.



YGA29-2N YGA34-2N

1 1

250 kcmil 500 kcmil

— —

① Where a “U” or “PU” die is recommended with the Y45 HYPRESS™, a PT6515 adapter must be used.

W8CVT (2) X8CRT (2) W8CVT (2) X8CRT (2) W8CVT (2) X8CRT (2) W8CVT (2) X8CRT (2) W5CVT (2) X5CRT (2) W5CVT (2) X5CRT (2) W5CVT (2) X5CRT (2) W5CVT (2) X5CRT (2) W5CVT (2) X5CRT (2) W2CVT (2) X2CRT (2) W2CVT (2) X2CRT (2) W2CVT (2) X2CRT (2) W25VT (4) X25RT (4) W26VT (4) X26RT (4) W28VT (4) X28RT (4) W29VT (4) W34VT (4)

Stud Size

B

C

L

T

E

U8CRT (2)

#10

.81

.41

1.57

.08



U8CRT (2)

1/4

.81

.44

1.69

.08



U8CRT (2)

5/16

.81

.51

1.75

.06



U8CRT (2)

1/2

.81

.71

4.09

.05



U5CRT (2)

#10

1.12

.42

1.89

.09



U5CRT (2)

1/4

1.12

.45

2.02

.08



U5CRT (2)

5/16

1.12

.51

2.08

.07



U5CRT (2)

3/8

1.12

.58

3.42

.06

.75

U5CRT (2)

1/2

1.12

.83

4.40

.12

1.75

U2CRT (2)

3/8

1.25

.60

3.48

.12

1.00

U2CRT (2)

3/8

1.25

.60

3.66

.12

.75

U2CRT (2)

1/2

1.22

.81

4.71

.12

1.75

U25RT (2)

1/2

1.35

.81

4.91

.12

1.75

U26RT (2)

1/2

1.45

.81

4.89

.12

1.75

U28RT (2)

1/2

1.57 1.00 5.06

.14

1.75

U29RT (2) U34RT (4)

1/2 1/2

1.57 1.09 5.16 2.20 1.52 5.94

.16 .23

1.75 1.75

➁ Where a “U” or “PU” die is recommended with the Y46 HYPRESS™, a PUADP-1 adapter must be used.