2010 catalog inside.indd - Anixter

Report 1 Downloads 198 Views
Basic & Metered

Basic & Metered

Monitored

Basic & Metered

Basic PDUs are available in a wide range of power capacities and configurations; however, they all serve the same function of distributing power from a single input to multiple receptacles. Reliable power distribution is a key cornerstone to every mission critical data center.

Switched

The Geist PM series meters can be configured as a Power Meter or Current Meter. The Power Meter provides a scrolling display of four critical power measurements which include Power Factor, Amps, Volts and Watts. The Current Meter version provides an accurate True RMS reading of the current draw.

Satellite

SPECIFICATION:

Power Factor – The ratio of Real Power to Apparent Power. Apparent Power is the calculation of Volts RMS* and Amps RMS*.

Watts – Displays power in Watts RMS*. Value is integration of instantaneous volts and current, referred to as Real Power.

Amps – Displays Current Draw in Amps RMS*

Volts – Displays Voltage RMS*

Resources

Educational

Brackets

Accessories

Software

Environmental

+/- 2% Accuracy with Full Scale 50/60Hz sine wave input

* RMS - Acronym for Root Mean Squared

4

www.geistmfg.com

Basic & Metered

Basic & Metered Basic & Metered Monitored

As IT equipment continues to draw increasing amounts of power, the need to meter current consumption at the rack is paramount. Metered PDUs contain a local meter to provide essential real-time information crucial for rack load capacity and balancing. This data is critical to insure breakers are not tripped by exceeding maximum current capacity. Additional information including voltage, wattage and power factor provide a more comprehensive power overview ideal for preventative maintenance and rack diagnostics.

Switched

The Geist CM-3 series scrolling 3 Phase Current Meter provides True RMS current readings for 3 Phase PDU’s. The CM-3 meter scrolls through each phase reading, eliminating the need for separate meters on each phase. Load balancing your 3 Phase installation has never been easier. SPECIFICATION:

Satellite

+/- 3.5% Accuracy with Full Scale 50/60Hz sine wave input

Environmental Software Accessories Brackets

Amps – Displays current draw in Amps RMS*

Circuit 1 – Represents Phase X

Educational Resources

Circuit 2 – Represents Phase Y

Circuit 3 – Represents Phase Z

* RMS - Acronym for Root Mean Squared

800-432-3219

5

Basic & Metered

Switched Satellite Environmental

-10 BRF

060

0 4

15

15

VOLTS

120

120

120

120

6

8

6

6

5-15R / 6

5-15R / 8

5-15R / 6

5-15R / 6

6

8

6

6

2.5

3.2

N/A

N/A

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

10’ POWER CORD

1

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

NO

YES

FLUSH MOUNTING

YES

OPT

YES

OPT

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

DIMENSIONS D

3.75

4.5

3.75

4.5

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Educational

60-1 3

15

RECEPTACLE CENTER TO CENTER SPACING (INCHES)

No Breaker and No Switch available on the following:

Resources

BR060-10 = JRN062-101D15ST5

6

BR0

2

15

RECEPTACLES PER BREAKER

Software

-10

1

AMPS

RECEPTACLE TYPE / QTY

Accessories

080

LINE DRAWING

TOTAL RECEPTACLE QTY

Brackets

BRX

• UL® & c-UL® Listed 60950

BRT

060

-10

Monitored

Basic & Metered

1.4kW 15 Amp, 120 Volt

www.geistmfg.com

1

2

3

4

Basic & Metered

15 Amp, 120 Volt, 1.4kW

0

20-1 BR1

0-10

-10

C10

BRF

100 BRF

BRC 100

0

00-1 BR1

3

4

5

15

15

15

15

VOLTS

120

120

120

120

120

TOTAL RECEPTACLE QTY

10

10

10

10

12

5-15R / 10

5-15R / 10

5-15R / 10

5-15R / 10

5-15R / 12

10

10

10

10

12

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

RECEPTACLES PER BREAKER

15 / 1

15 / 1

15 / 1

15 / 1

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

YES *

NO

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

OPT *

NO

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

N/A

10’ POWER CORD

1

1

1

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

OPT

YES

NO

FLUSH MOUNTING

YES

OPT

YES

OPT

YES

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

17

DIMENSIONS D

3.75

4.5

4.5

4.5

3.75

4

Brackets

1

5-15P

3

Accessories

1

STRAIGHT-BLADE PLUG

2

Software

15 / 1

ON-OFF SWITCH

1

Environmental

2

15

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

-10

Basic & Metered

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

5

Educational

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

No Breaker and No Switch available on the following: BR100-10 = JRN102-101D15ST5 BRC100-10 = JRCN102-101D15ST5 BR120-10 = JRN122-101D15ST5

800-432-3219

7

Basic & Metered

Switched Satellite

-10 SPF

064

0 15

VOLTS

120

120

120

120

6

8

6

6

5-15R / 6

5-15R / 8

5-15R / 6

5-15R / 6

6

8

6

6

2.5

3.2

N/A

N/A

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

10’ POWER CORD

1

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

NO

YES

FLUSH MOUNTING

YES

OPT

YES

OPT

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

DIMENSIONS D

3.75

4.5

3.75

4.5

No Switch Option: Insert N before first number in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Resources

Educational

64-1

4

15

MODIFY TO MEET YOUR NEEDS

8

SP0 3

15

RECEPTACLE CENTER TO CENTER SPACING (INCHES)

Environmental

084 2

15

RECEPTACLES PER BREAKER

Software

SPX

1

AMPS

RECEPTACLE TYPE / QTY

Accessories

064

LINE DRAWING

TOTAL RECEPTACLE QTY

Brackets

SPT

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules

-10

-10

Monitored

Basic & Metered

1.4kW 15 Amp, 120 Volt, Surge Suppressed

www.geistmfg.com

1

2

3

4

Basic & Metered

15 Amp, 120 Volt, Surge Suppressed, 1.4kW

24-1

0

4-10

SP1

-10

C10

SPF

104 SPF

SPC 104

0

04-1 SP1

2

3

4

5

15

15

15

15

15

VOLTS

120

120

120

120

120

TOTAL RECEPTACLE QTY

10

10

10

10

12

5-15R / 10

5-15R / 10

5-15R / 10

5-15R / 10

5-15R / 12

10

10

10

10

12

RECEPTACLES PER BREAKER

YES

YES

YES

YES

15 / 1

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

YES *

NO

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

OPT *

NO

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

N/A

10’ POWER CORD

1

1

1

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

OPT

YES

NO

FLUSH MOUNTING

YES

OPT

YES

OPT

YES

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

17

DIMENSIONS D

3.75

4.5

4.5

4.5

3.75

4

Brackets

1

5-15P

Accessories

1

STRAIGHT-BLADE PLUG

3 Software

YES

BREAKER AMPERAGE / QTY

2

Environmental

THERMAL CIRCUIT BREAKER

1

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

-10

Basic & Metered

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

5

Educational

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

800-432-3219

9

Basic & Metered

Satellite Environmental

15

NSV

BC2

0-10 B20

00- 1

1S1

0 1S

5

5 C14

NSV

0-10

0-10

1S1

1S1

5

5 1S1 K08

NSV

L08 NSV 1

2

3

4

5

6

15

15

15

15

15

VOLTS

120

120

120

120

120

120

8

8

10

14

20

20

5-15R / 8

5-15R / 8

5-15R / 10

5-15R / 14

5-15R / 20

5-15R / 20

8

8

10

14

20

20

1.25

2

2.95

2.95

2.8

2.8

INLINE

INLINE

INLINE

INLINE

INLINE

INLINE

RECEPTACLE CENTER TO CENTER SPACING (INCHES) RECEPTACLE ORIENTATION

Software

aew

15

RECEPTACLE TYPE / QTY

Accessories

aew

AMPS

RECEPTACLES PER BREAKER

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 1

15 / 1

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

NO

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

NO

NO

NO

OPT *

MONITORING

N/A

N/A

N/A

N/A

N/A

AGGREGATE

10’ POWER CORD

Brackets

aew

LINE DRAWING

TOTAL RECEPTACLE QTY

Educational

0-10

0 1S

0--1

Monitored Switched

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

aew

NSV

aew

15

aew

NSV A10

Basic & Metered

1.4kW 15 Amp, 120 Volt

1

1

1

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

OPT

HORIZONTAL/PANEL MOUNTING BRACKETS

YES

NO

NO

NO

NO

NO

1 BOTTOM & 1 TOP MOUNTING CLIP

YES

YES

YES

YES

NO

NO

1 BOTTOM & 2 TOP MOUNTING CLIPS

NO

NO

NO

NO

YES

YES

DIMENSIONS L (INCHES)

17

24

38.5

47.5

66.25

66.25

DIMENSIONS W

1.61

1.61

1.61

1.61

1.61

1.61

DIMENSIONS D

1.61

1.61

1.61

1.61

1.61

1.61

Resources

MODIFY TO MEET YOUR NEEDS Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before first number in part number

Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

10

www.geistmfg.com

1

2

3

4

5

6

Basic & Metered

5 ST 5IG 1S1

5 ST 5

2-10 N20 MJB

N20 MJB

MJC

N12

2-10

2-10

1S1

1S1

5 ST 5 1S1 2-10 N12 MJC

2

3

4

15

15

15

15

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

12

12

20

20

5-15R / 12

5-15R / 12

5-15R / 20

5-15R / 20

3.5

3.5

3

3

RECEPTACLES CENTER TO CENTER SPACING (INCHES)

INLINE

INLINE

NO

YES

NO

YES

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

1

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

MOUNTING BRACKETS

YES

YES

YES

YES

DIMENSIONS L (INCHES)

47.5

47.5

66.25

66.25

DIMENSIONS W

1.25

1.25

1.25

1.25

DIMENSIONS D

1.1

1.1

1.1

1.1

10’ POWER CORD

4

Accessories

INLINE

3

Software

INLINE

2

Environmental

RECEPTACLE ORIENTATION ISOLATED GROUND 3’ EXTERNAL GROUNDING WIRE

1

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

• UL® & c-UL® Listed 60950

Basic & Metered

5 ST 5IG

15 Amp, 120 Volt, 1.4kW

MODIFY TO MEET YOUR NEEDS

Brackets

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated Cord Length (Feet) 02-15 (Plug Attached) Plug Type: ST= Straight-Blade / TL= Twist-Lock

Educational Resources

800-432-3219

11

Basic & Metered

Switched Satellite Environmental Software Accessories

00- 1 3

15

15

VOLTS

120

120

120

6

10

10

5-15R / 6

5-15R / 10

5-15R / 10

6

10

10

1.75

N/A

N/A

THERMAL CIRCUIT BREAKER

YES

YES

YES

BREAKER AMPERAGE / QTY

RECEPTACLE CENTER TO CENTER SPACING (INCHES)

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

MONITORING

N/A

N/A

AGGREGATE

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

YES

YES

10’ POWER CORD

Brackets

VRT AC1

2

15

RECEPTACLES PER BREAKER

DIMENSIONS L (INCHES)

17

38.5

38.5

DIMENSIONS W

1.72

1.85

1.85

DIMENSIONS D

1.61

1.3

1.3

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Resources

0-10

1

AMPS

RECEPTACLE TYPE / QTY

Twist-Lock Plug Option: Add TL to end of part number

12

VRT A10

LINE DRAWING

TOTAL RECEPTACLE QTY

Educational

VRT

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

L06

0-10

Monitored

0

Basic & Metered

1.4kW 15 Amp, 120 Volt

www.geistmfg.com

1

2

3

Basic & Metered

15 Amp, 120 Volt, 1.4kW Basic & Metered

BC2 VRT

VRT

B20

0-10

00- 1

0

40- 1 CC1 VRT

0-10 C14 VRT

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

2

3

4

15

15

15

15

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

14

14

20

20

5-15R / 14

5-15R / 14

5-15R / 20

5-15R / 20

14

14

20

20

RECEPTACLES PER BREAKER

YES

YES

YES

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT*

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

10’ POWER CORD

1

1

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

DIMENSIONS L (INCHES)

47.5

47.5

66.25

66.25

DIMENSIONS W

1.85

1.85

1.85

1.85

DIMENSIONS D

1.3

1.3

1.3

1.3

Brackets

1

5-15P

4

Accessories

1

STRAIGHT-BLADE PLUG

3

Software

YES

BREAKER AMPERAGE / QTY

2

Environmental

THERMAL CIRCUIT BREAKER

1

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

0

aew

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number

Educational

Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Resources

800-432-3219

13

Basic & Metered

Satellite Environmental

15

BC2 VSS

VSS

B20

4-10

04- 1

1S1

0 1S

5

5 1S1

VSS

C14

4-10 A10

VSS

4-10

1S1

5 1S1 K08

4-10

0 1S

4--1 L08 1

2

3

4

5

6

15

15

15

15

15

VOLTS

120

120

120

120

120

120

8

8

10

14

20

20

5-15R / 8

5-15R / 8

5-15R / 10

5-15R / 14

5-15R / 20

5-15R / 20

8

8

10

14

20

20

1.25

2

2.95

2.95

2.8

2.8

INLINE

INLINE

INLINE

INLINE

INLINE

INLINE

RECEPTACLE CENTER TO CENTER SPACING (INCHES) RECEPTACLE ORIENTATION

Software

aew

15

RECEPTACLES PER BREAKER

Accessories

aew

AMPS

RECEPTACLE TYPE / QTY

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 1

15 / 1

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

NO

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

NO

NO

NO

OPT *

MONITORING

N/A

N/A

N/A

N/A

N/A

AGGREGATE

10’ POWER CORD

Brackets

aew

LINE DRAWING

TOTAL RECEPTACLE QTY

1

1

1

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

OPT

HORIZONTAL/PANEL MOUNTING BRACKETS

YES

NO

NO

NO

NO

NO

1 BOTTOM & 1 TOP MOUNTING CLIP

YES

YES

YES

YES

NO

NO

1 BOTTOM & 2 TOP MOUNTING CLIPS

NO

NO

NO

NO

YES

YES

DIMENSIONS L (INCHES)

Educational

VSS

Monitored Switched

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

aew 5

aew

15

aew

VSS

Basic & Metered

1.4kW 15 Amp, 120 Volt, Surge Suppressed

17

24

38.5

47.5

66.25

66.25

DIMENSIONS W

1.61

1.61

1.61

1.61

1.61

1.61

DIMENSIONS D

1.61

1.61

1.61

1.61

1.61

1.61

Resources

MODIFY TO MEET YOUR NEEDS Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before first number in part number

Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

14

www.geistmfg.com

1

2

3

4

5

6

Basic & Metered

15 Amp, 120 Volt, Surge Suppressed 1.4kW

04- 1 AC1 SVR

4-10 A10 SVR

4-10 L06 SVR

3

15

15

VOLTS

120

120

120

6

10

10

5-15R / 6

5-15R / 10

5-15R / 10

6

10

10

1.75

N/A

N/A

THERMAL CIRCUIT BREAKER

YES

YES

YES

BREAKER AMPERAGE / QTY

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER RECEPTACLES CENTER TO CENTER SPACING (INCHES)

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

MONITORING

N/A

N/A

AGGREGATE

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

YES

YES

10’ POWER CORD

DIMENSIONS L (INCHES)

17

38.5

38.5

DIMENSIONS W

1.72

1.85

1.85

DIMENSIONS D

1.61

1.3

1.3

Brackets

15 / 1

YES

3

Accessories

15 / 1

YES

2

Software

15 / 1

ON-OFF SWITCH

1

Environmental

2

15

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

0

Basic & Metered

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

Educational

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number

Resources

Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

800-432-3219

15

Basic & Metered

Basic & Metered

1.4kW 15 Amp, 120 Volt, Surge Suppressed

Satellite

Switched Environmental Software Accessories

0

04- 1 BC2 SVR

4-10 B20 SVR

2

3

4

15

15

15

15

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

14

14

20

20

5-15R / 14

5-15R / 14

5-15R / 20

5-15R / 20

14

14

20

20

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 1

15 / 1

15 / 1

15 / 1

ON-OFF SWITCH

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES*

NO

YES*

CURRENT MONITORING - LOCAL AMPS

NO

OPT*

NO

OPT*

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

1

1

1

1

STRAIGHT-BLADE PLUG

5-15P

5-15P

5-15P

5-15P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

DIMENSIONS L (INCHES)

47.5

47.5

66.25

66.25

DIMENSIONS W

1.85

1.85

1.85

1.85

DIMENSIONS D

1.3

1.3

1.3

1.3

10’ POWER CORD

Brackets

44- 1

1

AMPS

RECEPTACLES PER BREAKER

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number

Educational

CC1

LINE DRAWING

RECEPTACLE TYPE / QTY

Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

16

SVR

4-10 C14 SVR

Monitored

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

0

aew

www.geistmfg.com

1

2

3

4

Basic & Metered

20 Amp, 120 Volt, 1.9kW

-102 BRF

060

0 23

60-1 BR0

2

20

20

VOLTS

120

120

6

6

5-15R / 6

5-15R / 6

6

6

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

YES

YES

ON-OFF SWITCH 10’ POWER CORD

1

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKET

NO

YES

FLUSH MOUNTING

YES

OPT

DIMENSIONS H (INCHES)

1.72

17

17

DIMENSIONS D

3.75

4.5

Accessories

1.72

DIMENSIONS W

Software

1

STRAIGHT-BLADE PLUG

2

Environmental

THERMAL CIRCUIT BREAKER

1

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

3

Basic & Metered

• UL® & c-UL® Listed 60950

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number

Brackets

Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Educational

No Breaker and No Switch available on the following: BR060-1023 = JRN062-102D20ST5

Resources

800-432-3219

17

Basic & Metered

Satellite

Switched Environmental Software

026

20-1 BR1

0-10

C10

BRF 4

5

20

20

20

VOLTS

120

120

120

120

120

TOTAL RECEPTACLE QTY

10

10

10

10

12

5-20R / 10

5-20R / 10

5-20R / 10

5-20R / 10

5-20R / 12

10

10

10

10

12

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES*

YES*

NO

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT*

OPT*

NO

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

N/A

1

1

1

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

OPT

YES

NO

FLUSH MOUNTING

YES

OPT

YES

OPT

YES

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

17

DIMENSIONS D

3.75

4.5

4.5

4.5

3.75

MODIFY TO MEET YOUR NEEDS

Educational

5

3

20

No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Resources

BRC 100

100 BRF 2

20

10’ POWER CORD

No Breaker and No Switch available on the following: BR100-1025 = JRN102-102D20ST5 BRC100-1025 = JRCN102-102D20ST5 BR120-1026 = JRN122-102D20ST5

18

-102

5

-102

025

1

AMPS

RECEPTACLES PER BREAKER

Accessories

00-1

LINE DRAWING

RECEPTACLE TYPE / QTY

Brackets

BR1

Monitored

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

25

Basic & Metered

1.9kW 20 Amp, 120 Volt

www.geistmfg.com

1

2

3

4

5

Basic & Metered

20 Amp, 120 Volt, 1.9kW (x2)

QUANTITY OF INPUTS

3

5 5

2

2

2

2

20 x 2

20 x 2

20 x 2

20 x 2

20 x 2

VOLTS

120 x 2

120 x 2

120 x 2

120 x 2

120 x 2

20

20

5-20R / 20

5-20R / 20

5-20R / 20

RECEPTACLES PER INPUT

6

10

10

10

10

RECEPTACLES PER BREAKER

6

N/A

N/A

10

10

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

NO

NO

NO

YES

YES

THERMAL CIRCUIT BREAKER

YES

NO

NO

NO

NO

SINGLE

N/A

N/A

SINGLE

SINGLE

20 / 2

N/A

N/A

20 / 2

20 / 2

ON-OFF SWITCH

NO

NO

NO

BREAKER

BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES x 2 *

NO

YES x 2 *

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

NO

OPT*

MONITORING

N/A

N/A

CIRCUIT

N/A

CIRCUIT

BREAKER POLE CONFIGURATION BREAKER AMPERAGE / QTY

10’ POWER CORD

2

2

2

2

(2) 5-20P

(2) 5-20P

(2) 5-20P

(2) 5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

YES

NO

NO

NO

NO

2U RECESSED MOUNTING BRACKETS

NO

YES

YES

YES

YES

DIMENSIONS H (INCHES)

1.72

3.39

3.39

3.39

3.39

DIMENSIONS W

17

17

17

17

17

DIMENSIONS D

4.5

6

6

6

6

3

4

Brackets

2 (2) 5-20P

STRAIGHT-BLADE PLUG

2

Accessories

20

5-20R / 20

Software

20

5-20R / 12

Environmental

12

RECEPTACLE TYPE / QTY

1

Satellite

2

AMPS

TOTAL RECEPTACLE QTY

2D2 0DS T

C20

0-10

5

4

2JR

2JR

200

-102

D20 D ST

02D 20D ST

02-1

CN2

2D2 0DS T

2JR

2-10

N20

20-1 JRN 1

2JR 2

Switched

1

Monitored

LINE DRAWING

02D 20D ST

5

5

5

Basic & Metered

• UL® & c-UL® Listed 60950 • Multi-input units contain color-coded receptacle configurations and/or labeling for easy identification and load balancing * Detailed meter specs available on pages 4 & 5.

5

Educational Resources

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

800-432-3219

19

Basic & Metered

Switched Satellite Environmental Software Accessories Brackets

62-1

1

2

AMPS

20

20

VOLTS

120

120

6

6

RECEPTACLE TYPE / QTY

L5-20R / 6

L5-20R / 6

RECEPTACLES PER INPUT

6

6

RECEPTACLES PER BREAKER

N/A

N/A

CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

MONITORING

N/A

AGGREGATE

10’ POWER CORD

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

2U RECESSED MOUNTING BRACKETS

YES

YES

DIMENSIONS H (INCHES)

3.39

3.39

DIMENSIONS W

17

17

DIMENSIONS D

6

6

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Educational

CN0

LINE DRAWING

TOTAL RECEPTACLE QTY

Resources

Twist-Lock Plug Option: Add TL to end of part number

20

2JR

2JR

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

N06

2-10

Monitored

2L2 0ST 5

02L 20S T

5

Basic & Metered

1.9kW 20 Amp, 120 Volt

www.geistmfg.com

1

2

Basic & Metered

20 Amp, 120 Volt, Surge Suppressed, 1.9kW

-102 SPF

064

023

64-1 SP0 1

2

AMPS

20

20

VOLTS

120

120 6

5-20R / 6

5-20R / 6

RECEPTACLES PER BREAKER

6

YES

YES

BREAKER AMPERAGE / QTY

YES

10’ POWER CORD

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

FLUSH MOUNTING

YES

OPT

DIMENSIONS H (INCHES)

1.72

1.72

DIMENSIONS W

17

17

DIMENSIONS D

3.75

4.5

Accessories

20 / 1

YES

Software

20 / 1

ON-OFF SWITCH

2 Environmental

6

THERMAL CIRCUIT BREAKER

1

Satellite

RECEPTACLE TYPE / QTY

6

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

3

Basic & Metered

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules

MODIFY TO MEET YOUR NEEDS

Brackets

No Switch Option: Insert N before first number in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Educational Resources

800-432-3219

21

Basic & Metered

Satellite

Switched Environmental Software Accessories

SP1

24-1

026

25

SPF

C10

4-10

5

-102

2

3

4

5

20

20

20

20

VOLTS

120

120

120

120

120

TOTAL RECEPTACLE QTY

10

10

10

10

12

5-20R / 10

5-20R / 10

5-20R / 10

5-20R / 10

5-20R / 12

10

10

10

10

12

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

YES *

NO

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

OPT *

NO

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

N/A

1

2

3

10’ POWER CORD

1

1

1

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

YES

OPT

YES

NO

FLUSH MOUNTING

YES

OPT

YES

OPT

YES

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

17

DIMENSIONS D

3.75

4.5

4.5

4.5

3.75

MODIFY TO MEET YOUR NEEDS

Educational

SPC 104

1 20

RECEPTACLES PER BREAKER

No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

22

-102

5

SP1

LINE DRAWING AMPS

RECEPTACLE TYPE / QTY

Brackets

104

04-1

025

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

SPF

Monitored

Basic & Metered

1.9kW 20 Amp, 120 Volt, Surge Suppressed

www.geistmfg.com

4

5

Basic & Metered

20 Amp, 120 Volt, 1.9kW

20

NSV

BC2

00- 1

2S2

NSV

B20

0-10

0-10 C14

NSV

0 2S

0

0 2S2

0 2S2 0-10

NSV A10

NSV

K08

0-10

2S2 0-10 L08 NSV

2

3

4

5

6

20

20

20

20

20

20

VOLTS

120

120

120

120

120

120

8

8

10

14

20

20

5-20R / 8

5-20R / 8

5-20R / 10

5-20R / 14

5-20R / 20

5-20R / 20

8

8

10

14

20

20

1.25

2

2.95

2.95

2.8

2.8

INLINE

INLINE

INLINE

INLINE

INLINE

INLINE

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER

RECEPTACLE ORIENTATION

YES

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

20 / 1

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

NO

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

NO

NO

NO

OPT *

MONITORING

N/A

N/A

N/A

N/A

N/A

AGGREGATE

1

1

1

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

OPT

HORIZONTAL/PANEL MOUNTING BRACKETS

YES

NO

NO

NO

NO

NO

ONE BOTTOM & ONE TOP MOUNTING CLIP

YES

YES

YES

YES

NO

NO

ONE BOTTOM & TWO TOP MOUNTING CLIPS

NO

NO

NO

NO

YES

YES

DIMENSIONS L (INCHES)

17

24

38.5

47.5

66.25

66.25

DIMENSIONS W

1.61

1.61

1.61

1.61

1.61

1.61

DIMENSIONS D

1.61

1.61

1.61

1.61

1.61

1.61

6

Educational

1

5-20P

5

Brackets

1

5-20P

4

Accessories

1

STRAIGHT-BLADE PLUG

3

Software

THERMAL CIRCUIT BREAKER

10’ POWER CORD

2

Environmental

RECEPTACLE CENTER TO CENTER SPACING (INCHES)

1

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

2S2

0

0

Basic & Metered

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before first number in part number

Twist-Lock Plug Option: Add TL to end of part number

Resources

Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Current Monitoring Option: Replace C with A in part number

800-432-3219

23

Basic & Metered

Satellite

Switched Environmental

0 ST 5IG 2S2

2S2 MJB

N20

2-10

2-10 N20 3

4

20

20

20

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

12

12

20

20

5-20R / 12

5-20R / 12

5-20R / 20

5-20R / 20

3.5

3.5

3

3

INLINE

INLINE

INLINE

INLINE

ISOLATED GROUND 3’ EXTERNAL GROUNDING WIRE

NO

YES

NO

YES

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

1

1

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

MOUNTING BRACKETS

YES

YES

YES

YES

DIMENSIONS L (INCHES)

47.5

47.5

66.25

66.25

DIMENSIONS W

1.25

1.25

1.25

1.25

DIMENSIONS D

1.1

1.1

1.1

1.1

10’ POWER CORD

Software

0 ST 5

0 ST 5IG 2S2

2

20

RECEPTACLE ORIENTATION

Accessories

2-10

1

AMPS

RECEPTACLES CENTER TO CENTER SPACING (INCHES)

MODIFY TO MEET YOUR NEEDS Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Brackets

N12

LINE DRAWING

RECEPTACLE TYPE / QTY

Cord Length (Feet) 02-15 (Plug Attached)

Resources

Educational

Plug Type: ST= Straight-Blade / TL= Twist-Lock

24

MJB

• UL® & c-UL® Listed 60950

MJC

MJC

N12

2-10

Monitored

2S2

0 ST 5

Basic & Metered

1.9kW 20 Amp, 120 Volt

www.geistmfg.com

1

2

3

4

Basic & Metered

20 Amp, 120 Volt, 1.9kW

VRT AC1

00- 1

25 VRT A10

0-10

23 0-10 L06 VRT

2

3

20

20

20

VOLTS

120

120

120

6

10

10

5-20R / 6

5-20R / 10

5-20R / 10

6

10

10

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER

YES

YES

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

MONITORING

N/A

N/A

AGGREGATE

10’ POWER CORD

1

1

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

YES

YES

DIMENSIONS L (INCHES)

38.5

38.5

1.72

1.85

1.85

DIMENSIONS D

1.61

1.3

1.3

Brackets

17

DIMENSIONS W

Accessories

1

STRAIGHT-BLADE PLUG

3

Software

YES

BREAKER AMPERAGE / QTY

2

Environmental

THERMAL CIRCUIT BREAKER

1

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

0 25

Basic & Metered

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Educational

No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Resources

800-432-3219

25

Basic & Metered

Basic & Metered

1.9kW 20 Amp, 120 Volt

Environmental Software Accessories

0 21

00- 1 BC2 VRT

0-10 B20 VRT

2

3

4

20

20

20

20

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

14

14

20

20

5-20R / 14

5-20R / 14

5-20R / 20

5-20R / 20

14

14

20

20

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

10’ POWER CORD

Brackets

CC1

1

AMPS

RECEPTACLES PER BREAKER

1

1

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

DIMENSIONS L (INCHES)

47.5

47.5

66.25

66.25

DIMENSIONS W

1.85

1.85

1.85

1.85

DIMENSIONS D

1.3

1.3

1.3

1.3

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number

Educational

VRT

C14 VRT

LINE DRAWING

RECEPTACLE TYPE / QTY

Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

26

210

0 27

40- 1

27 0-10

Monitored Satellite

Switched

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

0

aew

www.geistmfg.com

1

2

3

4

Basic & Metered

0IN6 ST5

T5

JBN 3

-102 082 JLC N

02-1

I44S

4 ST 5

02I4

82- 1 JLN 0

200 JBC N

JBN 2

00-1

0 2D

-102

20D

D20

ST5

T5 20S

0 2D

42-1 1

2

3

4

5

6

1

2

2

1

1

1

20

20 x 2

20 x 2

20

20

20

VOLTS

120

120 x 2

120 x 2

120

120

120

20

20

8

8

30

5-20R / 24

5-20R / 20

5-20R / 20

C-13 / 4

C-13 / 4

C-13 / 24

RECEPTACLES PER INPUT

N/A

10

10

N/A

N/A

N/A

RECEPTACLES PER BREAKER

N/A

10

10

N/A

N/A

N/A

RECEPTACLE TYPE / QTY

N/A

N/A

N/A

C-19 / 4

C-19 / 4

C-19 / 6

NO

NO

NO

20 / 2

N/A

N/A

N/A

ON-OFF SWITCH

NO

NO

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES x 2 *

NO

YES *

NO

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

NO

OPT *

NO

MONITORING

N/A

N/A

CIRCUIT

N/A

AGGREGATE

N/A

1

2

2

1

1

1

STRAIGHT-BLADE PLUG

5-20P

(2) 5-20P

(2) 5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

NO

NO

NO

YES

YES

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

NO

NO

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

N/A

N/A

61.25 & 64.75

10’ POWER CORD

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

66.25

66.25

17

17

66.25

2

1.85

1.85

1.72

1.72

2

DIMENSIONS D

2

1.3

1.3

1.85

1.85

2

Resources

66.25

DIMENSIONS W

Educational

YES

20 / 2

6

Brackets

YES

N/A

5

Accessories

NO

BREAKER AMPERAGE / QTY

4

Software

THERMAL CIRCUIT BREAKER

3

Environmental

24

RECEPTACLE TYPE / QTY

2

Satellite

AMPS

1

Switched

LINE DRAWING QUANTITY OF INPUTS

TOTAL RECEPTACLE QTY

Monitored

JBN 2

Basic & Metered

• UL® & c-UL® Listed 60950 • Multi-input units contain color-coded receptacle configurations and/or labeling for easy identification and load balancing * Detailed meter specs available on pages 4 & 5.

DST 5

20 Amp, 120 Volt, 1.9kW (x2)

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

800-432-3219

27

Basic & Metered

Switched Satellite Environmental

20

04- 1 BC2 VSS

VSS

VSS

B20

C14

4-10

4-10

2S2

0 2S

0

0 2S2

0 2S2

VSS

A10

4-10

2S2 4-10 K08 3

4

5

6

20

20

20

20

20

VOLTS

120

120

120

120

120

120

8

8

10

14

20

20

5-20R / 8

5-20R / 8

5-20R / 10

5-20R / 14

5-20R / 20

5-20R / 20

8

8

10

14

20

20

1.25

2

2.95

2.95

2.8

2.8

INLINE

INLINE

INLINE

INLINE

INLINE

INLINE

RECEPTACLE CENTER TO CENTER SPACING (INCHES) RECEPTACLE ORIENTATION

Software

VSS 2

20

RECEPTACLES PER BREAKER

Accessories

2S2 1

AMPS

RECEPTACLE TYPE / QTY

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

20 / 1

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

NO

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

NO

NO

NO

OPT *

MONITORING

N/A

N/A

N/A

N/A

N/A

AGGREGATE

10’ POWER CORD

Brackets

4-10

LINE DRAWING

TOTAL RECEPTACLE QTY

1

1

1

1

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

NO

NO

NO

NO

NO

ONE BOTTOM & ONE TOP MOUNTING CLIPS

YES

YES

YES

YES

NO

NO

ONE BOTTOM & TWO TOP MOUNTING CLIPS

NO

NO

NO

NO

YES

YES

DIMENSIONS L (INCHES)

Educational

L08

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

VSS

Monitored

0

0

Basic & Metered

1.9kW 20 Amp, 120 Volt, Surge Suppressed

17

24

38.5

47.5

66.25

66.25

DIMENSIONS W

1.61

1.61

1.61

1.61

1.61

1.61

DIMENSIONS D

1.61

1.61

1.61

1.61

1.61

1.61

Resources

MODIFY TO MEET YOUR NEEDS Rotate Receptacle Orientation 90º: S= Inline / R= Rotated

Cord Length (Feet) 02-15 (Plug Attached)

No Switch Option: Insert N before first number in part number

Twist-Lock Plug Option: Add TL to end of part number

Current Monitoring Option: Replace C with A in part number

28

www.geistmfg.com

1

2

3

4

5

6

Basic & Metered

20 Amp, 120 Volt, Surge Suppressed, 1.9kW

SVR

AC1

04- 1

25 SVR

A10

4-10

23 4-10 L06 SVR

2

3

20

20

20

VOLTS

120

120

120

6

10

10

5-20R / 6

5-20R / 10

5-20R / 10

6

10

10

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER

YES

YES

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

MONITORING

N/A

N/A

AGGREGATE

10’ POWER CORD

1

1

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

YES

YES

DIMENSIONS L (INCHES)

38.5

38.5

1.72

1.85

1.85

DIMENSIONS D

1.61

1.3

1.3

Brackets

17

DIMENSIONS W

Accessories

1

STRAIGHT-BLADE PLUG

3

Software

YES

BREAKER AMPERAGE / QTY

2

Environmental

THERMAL CIRCUIT BREAKER

1

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

0 25

Basic & Metered

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Educational

No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Resources

800-432-3219

29

Basic & Metered

Basic & Metered

1.9kW 20 Amp, 120 Volt, Surge Suppressed

Satellite

Switched Environmental Software Accessories

0

0 21

04- 1 BC2 SVR

SVR

B20

4-10

210

0 27

2

3

4

20

20

20

20

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

14

14

20

20

5-20R / 14

5-20R / 14

5-20R / 20

5-20R / 20

14

14

20

20

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 1

20 / 1

20 / 1

20 / 1

ON-OFF SWITCH

YES

YES

YES

YES

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

10’ POWER CORD

Brackets

44- 1

1

AMPS

RECEPTACLES PER BREAKER

1

1

1

1

STRAIGHT-BLADE PLUG

5-20P

5-20P

5-20P

5-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

DIMENSIONS L (INCHES)

47.5

47.5

66.25

66.25

DIMENSIONS W

1.85

1.85

1.85

1.85

DIMENSIONS D

1.3

1.3

1.3

1.3

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number

Educational

CC1

LINE DRAWING

RECEPTACLE TYPE / QTY

Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

30

SVR

27 4-10 C14

• UL® & c-UL® Listed 60950 • Surge Suppression: 330V, 720 Joules * Detailed meter specs available on pages 4 & 5.

SVR

Monitored

aew

www.geistmfg.com

1

2

3

4

Basic & Metered

0/16 LCN

BRE

02-0 LN1 BRE

102

020

-002

/16

6 20/1

C16

-002 160 BRE

0-00

0/16

020 62-0

CN1

BRE

BRE

6 20/1 2-00 N16

BRE

3

4

5

6

20

20

20

20

20

VOLTS

120 or 208

120 or 208

120 or 208

120 or 208

120 or 208

120 or 208

16

16

16

16

10

10

C-13 / 16

C-13 / 16

C-13 / 16

C-13 / 16

C-13 / 10

C-13 / 10

N/A

N/A

16

16

N/A

N/A

NO

NO

YES

YES

NO

NO

BREAKER AMPERAGE / QTY

N/A

N/A

20 / 1

20 / 1

N/A

N/A

BREAKER POLE CONFIGURATION

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

DOUBLE

N/A

N/A

BREAKER

BREAKER

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

N/A

AGGREGATE

IEC POWER INLET (WITH CORD RETAINING CLAMP)

C-20

C-20

C-20

C-20

C-20

C-20

10’ POWER CORD

NO

NO

NO

NO

NO

NO

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

YES

YES

YES

YES

NO

NO

HORIZONTAL & VERTICAL MOUNTING BRACKETS

NO

NO

NO

NO

YES

YES

DIMENSIONS L/H (INCHES)

1.72

1.72

1.72

1.72

17

17

17

17

17

17

1.72

1.72

DIMENSIONS D

4.5

4.5

4.5

4.5

1.61

1.61

4

5

6

Educational

DIMENSIONS W

3

Brackets

DOUBLE

NO

Accessories

N/A

NO

2

Software

N/A

ON-OFF SWITCH

1

Environmental

2

20

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

IEC inlet units allow the PDU to supply 120V, 208V or 230V. The voltage distributed is determined by the voltage input. (For a complete offering of IEC Cord Sets see page 169)

/16

20 Amp, 120 or 208 Volt, 1.9kW/3.3kW

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number

Resources

800-432-3219

31

Basic & Metered

Satellite Environmental Software Accessories

20 13C

0/16

02C 42-0 BN2 VRZ

3

4

5

1

1

1

3

VRT

VRT

EN2

ECN

200

00-0

020

-002

/16

0/16 202 2

1

AMPS

20

20

20

20

20 x 3

VOLTS

120 or 208

120 or 208

120 or 208

120 or 208

(120 or 208) x 3

20

20

20

20

24

RECEPTACLE TYPE / QTY

C-13 / 20

C-13 / 20

C-13 / 20

C-13 / 20

C-13 / 24

RECEPTACLES PER INPUT

N/A

N/A

N/A

N/A

8

RECEPTACLES PER BREAKER PAIR

N/A

N/A

20

20

N/A

THERMAL CIRCUIT BREAKER

NO

NO

YES

YES

NO

BREAKER AMPERAGE / QTY

N/A

N/A

20 / 2

20 / 2

N/A

ON-OFF SWITCH

NO

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

NO

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

NO

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

N/A

IEC POWER INLET (WITH CORD RETAINING CLAMP)

C-20

C-20

C-20

C-20

C-20 x 3

10’ POWER CORD

NO

NO

NO

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

YES

ONE BOTTOM & TWO TOP MOUNTING CLIPS

OPT

OPT

OPT

OPT

NO

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

66.25

DIMENSIONS W

1.61

1.61

1.61

1.61

2

DIMENSIONS D

1.61

1.61

1.61

1.61

1.61

MODIFY TO MEET YOUR NEEDS

Resources

Current Monitoring Option: Replace C with A in part number

32

-002

/16 1

QUANTITY OF INPUTS

TOTAL RECEPTACLE QTY

Brackets

020

LINE DRAWING

VRT

VRT

Switched

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Educational

02-0 EN2

Monitored

IEC inlet units allow the PDU to supply 120V, 208V or 230V. The voltage distributed is determined by the voltage input. (For a complete offering of IEC Cord Sets see page 169)

ECN

Basic & Metered

1.9kW/3.3kW 20 Amp, 120 or 208 Volt

www.geistmfg.com

1

2

3

4

5

Basic & Metered

T6 0 2D

20- 1 RC1

R12 VHV

VHV

0-10

2D2

-102 122 RCN

VHV

20 S

0ST 6

D20

T6 20S

0 2D

22-1 RN1 VHV

3

4

20

20

20

VOLTS

208

208

208

208

TOTAL RECEPTACLE QTY

12

12

12

12

6-20R / 12

6-20R / 12

6-20R / 12

6-20R / 12

N/A

N/A

12

12

NO

NO

YES

YES

BREAKER AMPERAGE / QTY

N/A

N/A

20 / 1

20 / 1

BREAKER POLE CONFIGURATION

RECEPTACLES PER BREAKER MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

DOUBLE

BREAKER

BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

1

1

1

1

STRAIGHT-BLADE PLUG

6-20P

6-20P

6-20P

6-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

YES

YES

YES

YES

DIMENSIONS H (INCHES)

1.72

10’ POWER CORD

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6.5

6.5

6.5

6.5

3

4

Brackets

DOUBLE

NO

Accessories

N/A

NO

2

Software

N/A

ON-OFF SWITCH

1

Environmental

2

20

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

ST6

20 Amp, 208 Volt, 3.3kW

Educational

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Resources

800-432-3219

33

Basic & Metered

Satellite Environmental Software Accessories

-102

20D

VRC 200

0 2D

00-1

D20

ST6

DST 6

T6 0DS 3

4

2

2

2

AMPS

20 x 2

20 x 2

20 x 2

20 x 2

VOLTS

208 x 2

208 x 2

208 x 2

208 x 2

20

20

20

20

6-20R / 20

6-20R / 20

6-20R / 20

6-20R / 20

RECEPTACLES PER INPUT

10

10

10

10

RECEPTACLES PER BREAKER

N/A

N/A

10

10

NO

NO

YES

YES

BREAKER AMPERAGE / QTY

N/A

N/A

20 / 2

20 / 2

BREAKER POLE CONFIGURATION

N/A

N/A

DOUBLE

DOUBLE

ON-OFF SWITCH

NO

NO

BREAKER

BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES x 2 *

NO

YES x 2 *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

MONITORING

N/A

CIRCUIT

N/A

CIRCUIT

2

2

2

2

10’ POWER CORD STRAIGHT-BLADE PLUG

Brackets

VR2

2

2

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Educational

2D2

1

QUANTITY OF INPUTS

RECEPTACLE TYPE / QTY

(2) 6-20P

(2) 6-20P

(2) 6-20P

(2) 6-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

2U RECESSED MOUNTING BRACKETS

YES

YES

YES

YES

DIMENSIONS H (INCHES)

3.39

3.39

3.39

3.39

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6

6

6

6

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number

Resources

2-10

LINE DRAWING

TOTAL RECEPTACLE QTY

Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

34

VRC N20

2VH

2VH

2VH

Switched

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

2VH

VRN

202

Monitored

-102

D20

DST 6

Basic & Metered

3.3kW (x2) 20 Amp, 208 Volt

www.geistmfg.com

1

2

3

4

Basic & Metered

3 ST 6 2-10

VLC N16

3

4

20

20

VOLTS

208

208

208

208

6

6

16

16

RECEPTACLE TYPE / QTY

2C1

ST6 2VH

VLN 2VH

2VH

162

VRC N06

-102

2-10

C13

2L2

ST6 L20 -102 062 VRN 2VH

2 20

C-13 / 16

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

1

1

1

1

STRAIGHT-BLADE PLUG

6-20P

6-20P

6-20P

6-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

2U RECESSED MOUNTING BRACKETS

YES

YES

NO

NO

FLUSH OR PANEL MOUNTING

NO

NO

YES

YES

DIMENSIONS H (INCHES)

10’ POWER CORD

3.39

3.39

3.45

3.45

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6

6

1.61

1.61

2

3

Accessories

C-13 / 16

NO

Software

L6-20R / 6

NO

Environmental

L6-20R / 6

CIRCUIT BREAKER / ON-OFF SWITCH

1

Satellite

1 20

Switched

LINE DRAWING AMPS

TOTAL RECEPTACLE QTY

Monitored

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

0 ST 6

20 Amp, 208 Volt, 3.3kW

4

Brackets

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached) Twist-Lock Plug Option: Add TL to end of part number

Educational Resources

800-432-3219

35

Basic & Metered

Satellite

Switched Environmental Software Accessories

DST 6 202

BCN VHV

VHV

BN2

02-1

0 2D

-102

20D

20 S

0 2D

42-1 BN2

D20

ST6

T6

ST6

2

3

4

5

1

1

1

2

2

AMPS

20

20

20

20 x 2

20 x 2

VOLTS

208

208

208

208 x 2

208 x 2

20

20

24

20

20

RECEPTACLE TYPE / QTY

6-20R / 20

6-20R / 20

6-20R / 24

6-20R / 20

6-20R / 20

RECEPTACLES PER INPUT

N/A

N/A

N/A

10

10

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

NO

YES x 2 *

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

NO

OPT *

MONITORING

N/A

AGGREGATE

N/A

N/A

CIRCUIT

1

1

1

1

1

STRAIGHT-BLADE PLUG

6-20P

6-20P

6-20P

(2) 6-20P

(2) 6-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

66.25

DIMENSIONS W

1.85

1.85

2

1.85

1.85

DIMENSIONS D

1.3

1.3

2

1.3

1.3

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

Brackets

VHV

1

QUANTITY OF INPUTS

10’ POWER CORD

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number

Educational

202

LINE DRAWING

TOTAL RECEPTACLE QTY

Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

36

BCN

VHV

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

VHV

BN2

02-1

Monitored

0 2D

-102

20 S

D20

T6

Basic & Metered

3.3kW (x2) 20 Amp, 208 Volt

www.geistmfg.com

1

2

3

4

5

Basic & Metered

I44S -102

VHV

LCN

082

-102 082 LCN VHV

82-1 LN0 VHV

T6

ST6

C13

4 ST 6

02I4

13 S

0 2C

82-1 LN0 VHV

3

4

20

20

20

VOLTS

208

208

208

208

8

8

8

8

RECEPTACLE TYPE / QTY

C-13 / 8

C-13 / 4

C-13 / 8

C-13 / 4

RECEPTACLE TYPE / QTY

N/A

C-19 / 4

N/A

C-19 / 4

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

YES *

CURRENT MONITORING - LOCAL AMPS

NO

NO

OPT *

OPT *

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

1

1

1

6-20P

6-20P

6-20P

6-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

YES

YES

YES

17

17

17

17

DIMENSIONS W

DIMENSIONS L (INCHES)

1.72

1.72

1.72

1.72

DIMENSIONS D

1.61

1.85

1.61

1.85

3

4

Accessories

1

STRAIGHT-BLADE PLUG

2

Software

10’ POWER CORD

1

Environmental

2

20

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

T6

20 Amp, 208 Volt, 3.3kW

Brackets

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Educational

Twist-Lock Plug Option: Add TL to end of part number

Resources

800-432-3219

37

Basic & Metered

Environmental

Satellite

Switched Software Accessories Brackets

6ST 6

ST6

02IN

02-1 BN3 VHV

BCN VHV

BN2 VHV

242

42-1

0 2C

-102

13 S

C13

T6

ST6

102

1

2

3

4

5

AMPS

20

20

20

20

20

VOLTS

208

208

208

208

208

TOTAL RECEPTACLE QTY

10

10

24

24

30

RECEPTACLE TYPE / QTY

C-13 / 10

C-13 / 10

C-13 / 24

C-13 / 24

C-13 / 24

RECEPTACLE TYPE / QTY

N/A

N/A

N/A

N/A

C-19 / 6

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

NO

CURRENT MONITORING - LOCAL AMPS

NO

OPT *

NO

OPT *

NO

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

N/A

1

1

1

1

1

STRAIGHT-BLADE PLUG

6-20P

6-20P

6-20P

6-20P

6-20P

TWIST-LOCK PLUG

OPT

OPT

OPT

OPT

OPT

HORIZONTAL / PANEL MOUNTING BRACKETS

YES

YES

N/A

N/A

N/A

FULL-LENGTH VERTICAL MOUNTING BRACKET

N/A

N/A

YES

YES

YES

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

N/A

N/A

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES)

17

17

66.25

66.25

66.25

DIMENSIONS W

1.72

1.72

1.72

1.72

2

DIMENSIONS D

1.61

1.61

1.61

1.61

2

MODIFY TO MEET YOUR NEEDS

Educational

LCN

LINE DRAWING

10’ POWER CORD

Current Monitoring Option: Replace C with A in part number Cord Length (Feet) 02-15 (Plug Attached)

Resources

Twist-Lock Plug Option: Add TL to end of part number

38

VHV

VHV

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

LN1

02-1

Monitored

0 2C

-102

13S

C13

T6

Basic & Metered

3.3kW 20 Amp, 208 Volt

www.geistmfg.com

1

2

3

4

5

Basic & Metered

1 T L2 L20 -102 JBA N

123

0 2L

23-1 JBN 1

-102 243 JBA N

20T

D20

L21

T L2

L21 20T

0 2D

43-1 JBN 2

3

4

20 x 3~

20 x 3~

20 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

120

120

120

120

TOTAL RECEPTACLE QTY

24

24

12

12

5-20R / 24

5-20R / 24

L5-20R / 12

L5-20R / 12

RECEPTACLES PER PHASE

4

NO

NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

PHASE (X,Y,Z)

N/A

PHASE (X,Y,Z)

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L21-20P

L21-20P

L21-20P

L21-20P

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

66.25

66.25

66.25

66.25

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

2

2

2

2

2

2

2

2

Brackets

DIMENSIONS W DIMENSIONS D

4

Accessories

4

NO

3

Software

8

NO

2

Environmental

8

CIRCUIT BREAKER / ON-OFF SWITCH

1

Satellite

2

20 x 3~

Switched

1

AMPS

RECEPTACLE TYPE / QTY

Monitored

LINE DRAWING

Basic & Metered

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

1

20 Amp, 3 Phase, 5.8kW

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

Educational Resources

800-432-3219

39

Basic & Metered

Switched Satellite

LINE DRAWING

Environmental

IN6T

21

-102 303

120 / 208 WYE

120 / 208 WYE

120

120

RECEPTACLE TYPE / QTY RECEPTACLES PER PHASE

Software

JBA N

VOLTS

RECEPTACLES PER PHASE

Accessories

6T L 20 x 3~

RECEPTACLE TYPE / QTY

30

30

C-13 / 24

C-13 / 24

8

8

C-19 / 6

C-19 / 6

2

2

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

MONITORING

N/A

PHASE (X,Y,Z)

10’ POWER CORD

1

1

TWIST-LOCK PLUG

L21-20P

L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

Brackets

02IN 2

20 x 3~

TOTAL RECEPTACLE QTY

YES

YES

61.25 & 64.75

61.25 & 64.75

66.25

66.25

DIMENSIONS W

2

2

DIMENSIONS D

2

2

MODIFY TO MEET YOUR NEEDS

Educational

03-1 1

AMPS

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

Resources

Cord Length (Feet) 02-15 (Plug Attached)

40

JBN 3

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

L21

Basic & Metered

5.8kW 20 Amp, 3 Phase

www.geistmfg.com

1

2

Basic & Metered

128 BAN VHV

VHV

BN1

28-1

0 2L

-102

20T

L20

L21

T L2

1

20T L21

02D

20T

VHV BAN 248 -1

0 2D

48-1 BN2 VHV

2

3

4

20 x 3~

20 x 3~

20 x 3~

20 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

208

208

208

208

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS TOTAL RECEPTACLE QTY RECEPTACLE TYPE / QTY

24

12

12

6-20R / 24

L6-20R / 12

L6-20R / 12 4

NO

NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

CIRCUIT (XY,YZ,ZX)

N/A

CIRCUIT (XY,YZ,ZX)

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L21-20P

L21-20P

L21-20P

L21-20P

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

2

2

DIMENSIONS D

2

2

2

2

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

Brackets

4

NO

4

Accessories

8

NO

3

Software

8

CIRCUIT BREAKER / ON-OFF SWITCH

2

Environmental

RECEPTACLES PER PHASE COMBINATION

24 6-20R / 24

1

Satellite

1

AMPS

Switched

LINE DRAWING

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

L21

20 Amp, 3 Phase, 5.8kW

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

Educational Resources

800-432-3219

41

Basic & Metered

Switched Satellite

LINE DRAWING

Environmental Software Accessories

L21 IN6T

21 6T L

-102 308 BAN

VHV

BN3 VHV

VHV

BAN

248

08-1

-102

02IN

13T

0 2C

3

4

20 x 3~

20 x 3~

20 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

208

208

208

208

TOTAL RECEPTACLE QTY

24

24

30

30

C-13 / 24

C-13 / 24

C-13 / 24

C-13 / 24

8

8

8

8

RECEPTACLE TYPE / QTY

N/A

N/A

C-19 / 6

C-19 / 6

RECEPTACLES PER PHASE COMBINATION

N/A

N/A

2

2

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

CIRCUIT (XY,YZ,ZX)

N/A

CIRCUIT (XY,YZ,ZX)

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L21-20P

L21-20P

L21-20P

L21-20P

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

DIMENSIONS W

1.72

1.72

2

2

DIMENSIONS D

1.61

1.61

2

2

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

Brackets

48-1

2

20 x 3~

RECEPTACLES PER PHASE COMBINATION

MODIFY TO MEET YOUR NEEDS

Educational

BN2 1

AMPS

RECEPTACLE TYPE / QTY

Resources

Cord Length (Feet) 02-15 (Plug Attached)

42

VHV

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

C13

L21

T L2

1

Basic & Metered

5.8kW 20 Amp, 3 Phase

www.geistmfg.com

1

2

3

4

Basic & Metered

21

1

2T L

T L2

2M1

M11

9-10

-102

WN 18 VHV

309 BAN VHV

VHV

BN3

N48 2VH

VBA

09-1

8-10

0 2M

2C1

11T L

21

3DT

21 DT L C13 -102 488 VBN 2VH

4

5

1

1

1

AMPS

(20 x 3~) x 2

(20 x 3~) x 2

20 x 3~

20 x 3~

20 x 3~

VOLTS

(120 / 208 WYE) x 2

(120 / 208 WYE) x 2

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

208

208

120 & 208

120 & 208

120 & 208

TOTAL RECEPTACLE QTY

48

48

30

30

18

RECEPTACLE TYPE / QTY

C-13 / 48

C-13 / 48

L6-20R / 6

L6-20R / 6

C-13 / 12

RECEPTACLES PER INPUT

24

24

N/A

N/A

N/A

RECEPTACLES PER PHASE COMBINATION PER INPUT

8

8

2

2

4

RECEPTACLE TYPE / QTY

N/A

N/A

5-20R / 24

5-20R / 24

5-20R / 6

RECEPTACLES PER PHASE

8

8

2

NO

NO

NO

NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES x 2 *

NO

YES *

NO

MONITORING

N/A

CIRCUIT (XY,YZ,ZX)

N/A

CIRCUIT (XY,YZ,ZX)

N/A

10’ POWER CORD

2

2

1

1

1

TWIST-LOCK PLUG

(2) L21-20P

(2) L21-20P

L21-20P

L21-20P

L21-20P

YES

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

66.25

66.25

66.25

70

3.5

3.5

2

2

2

DIMENSIONS D

2

2

2

2

2

4

5

Educational

66.25

DIMENSIONS W

3

Brackets

N/A

NO

2

Accessories

N/A

CIRCUIT BREAKER / ON-OFF SWITCH

1

Software

3

2

Environmental

2

2

Satellite

1

QUANTITY OF INPUTS

Switched

LINE DRAWING

FULL-LENGTH VERTICAL MOUNTING BRACKET

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

L21

20 Amp, 3 Phase, 5.8kW (x2)

MODIFY TO MEET YOUR NEEDS

Resources

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

43

Basic & Metered

11kW 20 Amp, 3 Phase

Satellite

Switched Environmental Software Accessories

6 PS5 3-10 YBA

YBN

303

N30

-102

3-10 N30

2IN6

IN6P

T L2 2IN6

L22 YBA

3

4

1

1

1

AMPS

20 x 3~

20 x 3~

20 x 3~

20 x 3~

VOLTS

230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

230

230

230

230

TOTAL RECEPTACLE QTY

30

30

30

30

C-13 / 24

C-13 / 24

C-13 / 24

C-13 / 24

8

8

8

8

C-19 / 6

C-19 / 6

C-19 / 6

C-19 / 6

2

2

2

2

CIRCUIT BREAKER / ON-OFF SWITCH

NO

NO

NO

NO

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

PHASE (X,Y,Z)

N/A

PHASE (X,Y,Z)

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L22-20P

L22-20P

N/A

N/A

N/A

N/A

20A, 230 / 400V, 4P / 5W

20A, 230 / 400V, 4P / 5W

RECEPTACLES PER PHASE

IEC 60309 PIN & SLEEVE CONNECTOR

Brackets

IN6T 2

1

RECEPTACLE TYPE / QTY

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

2

2

DIMENSIONS D

2

2

2

2

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

Educational

-102 1

QUANTITY OF INPUTS

RECEPTACLES PER PHASE

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

Resources

303

LINE DRAWING

RECEPTACLE TYPE / QTY

44

YBN

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

S56

2

Basic & Metered

aew 230/400V aew 230/400V aew 230/400V aew 230/400V

www.geistmfg.com

1

2

3

4

Basic & Metered

30 Amp, 120 Volt, 2.9kW

0-10

C12

XPR

-103 120 XPR

BRD

3D2

T L5 6T L 120

-103

80-1

CN0

BRD

D20

TL

0 34

L 34T 0-10 N08

3

4

5

30

30

30

30

VOLTS

120

120

120

120

120

UL® & c-UL® Listed 60950

NO

NO

NO

YES

YES

UL® & c-UL® Listed 1950

YES

YES

YES

NO

NO

TOTAL RECEPTACLE QTY

8

8

12

12

12

5-20R / 8

5-20R / 8

5-20R / 12

5-20R / 12

5-20R / 12

4

4

6

6

6

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

NO

NO

NO

YES

YES

THERMAL CIRCUIT BREAKER

YES

YES

YES

NO

NO

BREAKER AMPERAGE / QTY

15 / 2

15 / 2

15 / 2

20 / 2

20 / 2

RECEPTACLES PER BREAKER

2

3 Software

BREAKER POLE CONFIGURATION

1

Environmental

2

30

SINGLE

SINGLE

SINGLE

SINGLE

NO

NO

YES

BREAKER

BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

N/A

AGGREGATE

NO

OPT *

NO

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

NO

OPT *

1

1

1

1

1

TWIST-LOCK PLUG

L5-30P

L5-30P

L5-30P

L5-30P

L5-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

OPT

OPT

YES

YES

YES

FLUSH MOUNTING

YES

YES

NO

NO

NO

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

17

17

17

17

17

DIMENSIONS D

4.5

4.5

4.5

6.5

6.5

Resources

1.72

DIMENSIONS W

5

Educational

10’ POWER CORD

4

Brackets

A

Accessories

SINGLE

ON-OFF SWITCH

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

BRD

0T L

5

Basic & Metered

• UL® & c-UL® Listed (see chart for details) * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS No Switch Option: Insert N before first number in part number Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

45

Basic & Metered

Satellite

Switched Environmental

L5 60- 1 RC0

2XP

0-10

3L2

0 3L

0T L

20T

5

T L5 R06 2XP

2XP

RCN

62-1 RN0

062

0 3L

-103

30T

L30

L5

L5

2

3

4

5

6

30

30

30

30

30

VOLTS

120

120

120

120

120

120

TOTAL RECEPTACLE QTY

20

20

6

6

6

6

5-20R / 20

5-20R / 20

L5-30R / 6

L5-30R / 6

L5-20R / 6

L5-20R / 6

10

10

N/A

N/A

3

3

YES

YES

NO

NO

YES

YES

20 / 2

20 / 2

N/A

N/A

20 / 2

20 / 2

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY BREAKER POLE CONFIGURATION

Software

2XP

1 30

RECEPTACLES PER BREAKER

Accessories

00- 1

LINE DRAWING AMPS

RECEPTACLE TYPE / QTY

Brackets

RC2

2XP

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

2XP

R20

0-10

Monitored

3D2

0 3D

0T L

20T

5

Basic & Metered

2.9kW 30 Amp, 120 Volt

SINGLE

SINGLE

N/A

N/A

SINGLE

SINGLE

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

N/A

AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

OPT *

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

1

1

1

1

TWIST-LOCK PLUG

L5-30P

L5-30P

L5-30P

L5-30P

L5-30P

L5-30P

2U RECESSED MOUNTING BRACKETS

YES

YES

YES

YES

YES

YES

DIMENSIONS H (INCHES)

3.39

3.39

3.39

3.39

3.39

3.39

DIMENSIONS W

17

17

17

17

17

17

DIMENSIONS D

6

6

6

6

6

6

1

2

3

4

5

Educational

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

Resources

6

46

www.geistmfg.com

Basic & Metered

30 Amp, 120 Volt, 2.9kW 13T L5 2VR ELC N16 0-10 3C1 3TL 5

5

2VR ELN 160 -1

0-10

C12

XPR

03C

3T L 3C1

T L5 C13 -103 120 XPR

2

3

4

30

30

30

120

120

120

YES

YES

NO

NO

UL® & c-UL® Listed 1950

NO

NO

YES

YES

TOTAL RECEPTACLE QTY

12

12

16

16

C-13 / 12

C-13 / 12

C-13 / 16

C-13 / 16

6

6

8

8

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

YES

YES

NO

NO

THERMAL CIRCUIT BREAKER

NO

NO

YES

YES

BREAKER AMPERAGE / QTY

20 / 2

20 / 2

15 / 2

15 / 2

RECEPTACLES PER BREAKER

SINGLE

SINGLE

SINGLE

BREAKER

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

A

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L5-30P

L5-30P

L5-30P

L5-30P

YES

YES

NO

NO

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

NO

NO

YES

YES

DIMENSIONS H (INCHES)

1.72

1.72

3.45

3.45

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6.5

6.5

1.61

1.61

Educational

FLUSH OR PANEL MOUNTING

4

Brackets

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

Accessories

SINGLE BREAKER

3 Software

BREAKER POLE CONFIGURATION ON-OFF SWITCH

2

Environmental

120

UL® & c-UL® Listed 60950

1

Satellite

VOLTS

Switched

1 30

Monitored

LINE DRAWING AMPS

RECEPTACLE TYPE / QTY

Basic & Metered

• UL® & c-UL® Listed (see chart for details) * Detailed meter specs available on pages 4 & 5.

Resources

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

47

Basic & Metered

Satellite

Switched

VRT 1

2

AMPS

30

30

VOLTS

120

120

TOTAL RECEPTACLE QTY

20

20

5-20R / 20

5-20R / 20

RECEPTACLES PER BREAKER

Environmental

THERMAL CIRCUIT BREAKER BREAKER AMPERAGE / QTY

Software Accessories

10

10

YES

YES

15 / 2

15 / 2

SINGLE

SINGLE

ON-OFF SWITCH

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

MONITORING

N/A

AGGREGATE

BREAKER POLE CONFIGURATION

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

10’ POWER CORD

1

1

TWIST-LOCK PLUG

L5-30P

L5-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET

YES

YES

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES)

66.25

66.25

DIMENSIONS W

1.85

1.85

DIMENSIONS D

1.3

1.3

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

Brackets

200

LINE DRAWING

RECEPTACLE TYPE / QTY

Educational

DCN

• UL® & c-UL® Listed 1950 * Detailed meter specs available on pages 4 & 5.

VRT

DN2

00-1

Monitored

0 31

-103

0T L

10T

L

Basic & Metered

2.9kW 30 Amp, 120 Volt

1

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Resources

Cord Length (Feet) 02-15 (Plug Attached)

48

www.geistmfg.com

A T

2

Basic & Metered

L5 3D2

XPB

XPB

240

C24

0-10

D20 -103

0-10

C24

XPB

0DT

5 DT L

0T L 3D2

T L5 D20 -103 240 XPB 1

2

3

4

1

1

2

2

30

30

30 x 2

30 x 2

VOLTS

120

120

120 x 2

120 x 2

24

24

24

5-20R / 24

5-20R / 24

5-20R / 24

5-20R / 24

RECEPTACLES PER INPUT

N/A

N/A

12

12

RECEPTACLES PER BREAKER

12

12

6 PER POLE

6 PER POLE

YES

YES

YES

YES

20 / 2

20 / 2

20 / 2

20 / 2

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY

SINGLE

SINGLE

DOUBLE

DOUBLE

NO

YES *

NO

YES x 2 *

MONITORING

N/A

AGGREGATE

N/A

CIRCUIT

A

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

1

1

2

2

TWIST-LOCK PLUG

L5-30P

L5-30P

(2) L5-30P

(2) L5-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

YES

YES

YES

YES

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

2

2

DIMENSIONS D

2

2

2

2

Educational

BREAKER DOGHOUSE - 1.44” DEPTH

Brackets

10’ POWER CORD

Accessories

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

4

Software

BREAKER POLE CONFIGURATION POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

3

Environmental

24

RECEPTACLE TYPE / QTY

2

Satellite

AMPS

1

Switched

LINE DRAWING QUANTITY OF INPUTS

TOTAL RECEPTACLE QTY

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

5

30 Amp, 120 Volt, 2.9kW (x2)

Resources

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

49

Basic & Metered

Satellite Environmental

I44T -103

VRE

LCN

080

-103 080 LCN VRE

4

30

30

VOLTS

120

120

120

120

8

8

8

8

C-13 / 8

C-13 / 4

C-13 / 8

C-13 / 4

4

2

4

2

RECEPTACLE TYPE / QTY

N/A

C-19 / 4

N/A

C-19 / 4

RECEPTACLES PER BREAKER

N/A

2

N/A

2

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 2

15 / 2

15 / 2

15 / 2

SINGLE

SINGLE

SINGLE

SINGLE

ON-OFF SWITCH

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

YES *

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

BREAKER POLE CONFIGURATION

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

NO

OPT *

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

NO

OPT *

OPT *

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L5-30P

L5-30P

L5-30P

L5-30P

YES

YES

YES

YES

17

17

17

17

1.72

1.72

1.72

1.72

HORIZONTAL & VERTICAL MOUNTING BRACKETS DIMENSIONS L (INCHES) DIMENSIONS W

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Resources

Cord Length (Feet) 02-15 (Plug Attached)

50

L5

T L5

4T L 3

30

THERMAL CIRCUIT BREAKER

Software

80-1 2

30

RECEPTACLES PER BREAKER

Accessories

LN0

1

AMPS

RECEPTACLE TYPE / QTY

Brackets

03I4

13T

0 3C

VRE

LINE DRAWING

TOTAL RECEPTACLE QTY

Educational

VRE

LN0

80-1

Monitored Switched

• UL® & c-UL® Listed 1950 * Detailed meter specs available on pages 4 & 5.

C13

5

L5

Basic & Metered

2.9kW 30 Amp, 120 Volt

www.geistmfg.com

A T

1

2

3

4

Basic & Metered

T L5 -103

0 3C

BCN VRE

BN2 VRE

240

40-1

-103 100 LCN

VRE

C13

L5 13T

C13

L5 13T

0 3C

00-1 LN1 VRE

2

3

4

30

30

30

30

VOLTS

120

120

120

120

TOTAL RECEPTACLE QTY

10

10

24

24

C-13 / 10

C-13 / 10

C-13 / 24

C-13 / 24

5

5

12

12

RECEPTACLES PER BREAKER

1

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 2

15 / 2

15 / 2

15 / 2

SINGLE

SINGLE

SINGLE

SINGLE

ON-OFF SWITCH

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

1

1

1

L5-30P

L5-30P

L5-30P

L5-30P

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

YES

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

NO

YES

YES

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

N/A

N/A

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES)

17

17

66.25

66.25

DIMENSIONS W

1.72

1.72

1.72

1.72

DIMENSIONS D

1.61

1.61

1.72

1.72

Educational

1

TWIST-LOCK PLUG

Brackets

10’ POWER CORD

Accessories

A

4

Software

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

3

Environmental

THERMAL CIRCUIT BREAKER

BREAKER POLE CONFIGURATION

2

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

• UL® & c-UL® Listed 1950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

T L5

30 Amp, 120 Volt, 2.9kW

MODIFY TO MEET YOUR NEEDS A T

Resources

Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

51

Basic & Metered

Satellite

Switched Environmental

T L5

0 3C

80- 1 BC4 2XP 4

2

2

AMPS

30

30

30 x 2

30 x 2

VOLTS

120

120

120 x 2

120 x 2

30

30

48

48

RECEPTACLE TYPE / QTY

C-13 / 24

C-13 / 24

C-13 / 48

C-13 / 48

RECEPTACLES PER INPUT

N/A

N/A

24

24

RECEPTACLES PER BREAKER

12

12

12

12

C-19 / 6

C-19 / 6

N/A

N/A

3

3

N/A

N/A

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

20 / 2

20 / 2

20 / 4

20 / 4

SINGLE

SINGLE

SINGLE

SINGLE

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES x 2 *

MONITORING

N/A

AGGREGATE

N/A

CIRCUIT

BREAKER POLE CONFIGURATION

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

2

2

TWIST-LOCK PLUG

L5-30P

L5-30P

(2) L5-30P

(2) L5-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

YES

YES

YES

YES

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

3.5

3.5

DIMENSIONS D

2

2

2

2

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number Cord Length (Feet) 02-15 (Plug Attached)

52

13D

L5 3DT 3C1 0-10 B48

2XP 3

RECEPTACLES PER BREAKER

Software

0-10 2 1

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Accessories

C30

1 1

RECEPTACLE TYPE / QTY

Brackets

XPB

LINE DRAWING QUANTITY OF INPUTS

TOTAL RECEPTACLE QTY

Educational

3IN6

L5 IN6T -103 300 XPB

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Resources

T L5

Basic & Metered

2.9kW (x2) 30 Amp, 120 Volt

www.geistmfg.com

A T

1

2

3

4

Basic & Metered

L6 20T

6

00- 1 RC2 2XP

2XP

XPR

R20

C12

0-10

0-10

3D2

0 3D

0T L

0T L 3D2

T L6 D20 -103 120 XPR

3

4

30

30

30

VOLTS

208

208

208

208

TOTAL RECEPTACLE QTY

12

12

20

20

6-20R / 12

6-20R / 12

6-20R / 20

6-20R / 20

6

6

10

10

YES

YES

YES

YES

20 / 2

20 / 2

20 / 2

20 / 2

RECEPTACLES PER BREAKER MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY BREAKER POLE CONFIGURATION

DOUBLE

DOUBLE

DOUBLE

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L6-30P

L6-30P

L6-30P

L6-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

YES

YES

NO

NO

2U RECESSED MOUNTING BRACKETS

NO

NO

YES

YES

DIMENSIONS H (INCHES)

1.72

1.72

3.39

3.39

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6.5

6.5

6

6

4

Brackets

A

3

Accessories

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

2

Software

DOUBLE

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

1

Environmental

2

30

Satellite

1

AMPS

Switched

LINE DRAWING

RECEPTACLE TYPE / QTY

Monitored

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

6

30 Amp, 208 Volt, 5kW

Educational

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

Resources

800-432-3219

53

Basic & Metered

Switched Satellite Educational

L6 20T 60- 1 RC0

2XP 4

30

30

VOLTS

208

208

208

208

6

6

6

6

L6-30R / 6

L6-30R / 6

L6-20R / 6

L6-20R / 6

N/A

N/A

3

3

NO

NO

YES

YES

BREAKER AMPERAGE / QTY

N/A

N/A

20 / 2

20 / 2

BREAKER POLE CONFIGURATION

N/A

N/A

DOUBLE

DOUBLE

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L6-30P

L6-30P

L6-30P

L6-30P

2U RECESSED MOUNTING BRACKETS

YES

YES

YES

YES

DIMENSIONS H (INCHES)

3.39

3.39

3.39

3.39

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6

6

6

6

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Resources

Cord Length (Feet) 02-15 (Plug Attached)

54

0 3L

0T L 3L2 0-10 R06 3

30

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Environmental

6

T L6 2

30

RECEPTACLES PER BREAKER

Software

2XP

1

AMPS

RECEPTACLE TYPE / QTY

Accessories

062

LINE DRAWING

TOTAL RECEPTACLE QTY

Brackets

RCN

2XP

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

2XP

RN0

62-1

Monitored

0 3L

-103

30T

L30

L6

Basic & Metered

5kW 30 Amp, 208 Volt

www.geistmfg.com

A T

1

2

3

4

Basic & Metered

30 Amp, 208 Volt, 5kW

ELC N16 2VR

ELN 2VR

0-10

C13 -103 160

0-10

C12

XPR

3

4

30

30

30

208

208

208

208

UL® & c-UL® Listed 60950

YES

YES

NO

NO

UL® & c-UL® Listed 1950

NO

NO

YES

YES

TOTAL RECEPTACLE QTY

12

12

16

16

C-13 / 12

C-13 / 12

C-13 / 16

C-13 / 16

6

N/A

N/A

N/A

8

8

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

YES

YES

NO

NO

THERMAL CIRCUIT BREAKER

NO

NO

YES

YES

BREAKER POLE CONFIGURATION ON-OFF SWITCH

20 / 2

20 / 2

15 / 4

15 / 4

DOUBLE

DOUBLE

SINGLE

SINGLE

BREAKER

NO

NO

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

Accessories

BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

3 Software

BREAKER AMPERAGE / QTY

2

Environmental

6 N/A

1

Satellite

VOLTS

RECEPTACLES PER BREAKER PAIR

3C1

T L6

6 3T L 3C1

T L6 C13 -103 120 XPR

2

30

Switched

1

AMPS

RECEPTACLES PER BREAKER

Monitored

LINE DRAWING

RECEPTACLE TYPE / QTY

3T L

6

Basic & Metered

• UL® & c-UL® Listed (see chart for details) * Detailed meter specs available on pages 4 & 5.

4 A

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

1

1

1

1

TWIST-LOCK PLUG

L6-30P

L6-30P

L6-30P

L6-30P

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

YES

YES

NO

NO

FLUSH OR PANEL MOUNTING

NO

NO

YES

YES

DIMENSIONS H (INCHES)

3.45

1.72

3.45

17

17

17

17

DIMENSIONS D

6.5

6.5

1.61

1.61

Resources

1.72

DIMENSIONS W

Educational

10’ POWER CORD

Brackets

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

55

Basic & Metered

Satellite

Switched Environmental Software Accessories

0T L

XPB

C12

0-10

L20 XPB

120

-103

0-10

C24

XPB

3L2

T L6

0T L 3D2

T L6 D20 -103

3

4

5

6

30

30

30

30

30

VOLTS

208

208

208

208

208

208

UL® & c-UL® Listed 60950

NO

NO

YES

YES

YES

YES

UL® & c-UL® Listed 1950

YES

YES

NO

NO

NO

NO

TOTAL RECEPTACLE QTY

20

20

24

24

12

12 L6-20R / 12

6-20R / 20

6-20R / 20

6-20R / 24

6-20R / 24

L6-20R / 12

RECEPTACLES PER BREAKER

N/A

N/A

12

12

6

6

RECEPTACLES PER BREAKER PAIR

10

10

N/A

N/A

N/A

N/A

NO

NO

YES

YES

YES

YES

THERMAL CIRCUIT BREAKER

YES

YES

NO

NO

NO

NO

BREAKER AMPERAGE / QTY

15 / 4

15 / 4

20 / 2

20 / 2

20 / 2

20 / 2

SINGLE

SINGLE

DOUBLE

DOUBLE

DOUBLE

DOUBLE

ON-OFF SWITCH

NO

NO

BREAKER

BREAKER

BREAKER

BREAKER

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

N/A

AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

OPT *

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

1

1

1

1

TWIST-LOCK PLUG

L6-30P

L6-30P

L6-30P

L6-30P

L6-30P

L6-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) BREAKER DOGHOUSE - 1.44” DEPTH DIMENSIONS L (INCHES)

YES

YES

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

NO

NO

YES

YES

YES

YES

66.25

66.25

66.25

66.25

66.25

66.25

DIMENSIONS W

1.85

1.85

2

2

2

2

DIMENSIONS D

1.61

1.61

2

2

2

2

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number Cord Length (Feet) 02-15 (Plug Attached)

56

6

6

T L6 240 XPB

BCN 2

30

BREAKER POLE CONFIGURATION

Brackets

VRE

1

AMPS

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Educational

BN2

LINE DRAWING

RECEPTACLE TYPE / QTY

Resources

VRE

• UL® & c-UL® Listed (see chart for details) * Detailed meter specs available on pages 4 & 5.

200

00-1

Monitored

0 3D

-103

20T

D20

L6

Basic & Metered

5kW 30 Amp, 208 Volt

www.geistmfg.com

A T

1

2

3

4

5

6

Basic & Metered

I44T -103

VRE

LCN

080

-103 080 LCN VRE

80-1 LN0 VRE

L6

T L6 C13

6 4T L

03I4

13T

0 3C

80-1 LN0 VRE

3

4

30

30

30

VOLTS

208

208

208

208

8

8

8

8

C-13 / 8

C-13 / 4

C-13 / 8

C-13 / 4

4

2

4

2

RECEPTACLE TYPE / QTY

N/A

C-19 / 4

N/A

C-19 / 4

RECEPTACLES PER BREAKER PAIR

N/A

2

N/A

2

YES

YES

YES

YES

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER PAIR

THERMAL CIRCUIT BREAKER BREAKER AMPERAGE / QTY

15 / 4

15 /4

15 /4

SINGLE

SINGLE

SINGLE

ON-OFF SWITCH

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

NO

YES *

YES *

MONITORING

N/A

N/A

AGGREGATE

AGGREGATE

A

NO

NO

OPT *

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

NO

OPT *

OPT *

1

1

1

L6-30P

L6-30P

L6-30P

L6-30P

YES

YES

YES

YES

17

17

17

17

DIMENSIONS W

1.72

1.72

1.72

1.72

DIMENSIONS D

1.61

1.85

1.61

1.85

HORIZONTAL & VERTICAL MOUNTING BRACKETS DIMENSIONS L (INCHES)

Educational

1

TWIST-LOCK PLUG

4

Brackets

10’ POWER CORD

3

Accessories

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

2

Software

15 / 4 SINGLE

BREAKER POLE CONFIGURATION

1

Environmental

2

30

Satellite

1

AMPS

Switched

LINE DRAWING

TOTAL RECEPTACLE QTY

Monitored

• UL® & c-UL® Listed 1950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

L6

30 Amp, 208 Volt, 5kW

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Resources

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

57

Basic & Metered

Satellite

Switched Environmental Software

T L6 240

BCN VRE 4

30

30

VOLTS

208

208

208

208

TOTAL RECEPTACLE QTY

10

10

24

24

C-13 / 10

C-13 / 10

C-13 / 24

C-13 / 24

5

5

12

12

THERMAL CIRCUIT BREAKER

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

15 / 4

15 / 4

15 / 4

15 / 4

SINGLE

SINGLE

SINGLE

SINGLE

ON-OFF SWITCH

NO

NO

NO

NO

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

A

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L6-30P

L6-30P

L6-30P

L6-30P

HORIZONTAL & VERTICAL MOUNTING BRACKETS

YES

YES

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

NO

YES

YES

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

NO

NO

61.25 & 64.75

61.25 & 64.75

DIMENSIONS L (INCHES)

17

17

66.25

66.25

DIMENSIONS W

1.72

1.72

1.72

1.72

DIMENSIONS D

1.61

1.61

1.72

1.72

Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

Resources

-103

13T

0 3C

40-1 3

30

MODIFY TO MEET YOUR NEEDS

Cord Length (Feet) 02-15 (Plug Attached)

58

C13

L6

T L6 BN2

2

30

BREAKER POLE CONFIGURATION

Accessories

VRE

1

AMPS

RECEPTACLES PER BREAKER PAIR

Brackets

100

LINE DRAWING

RECEPTACLE TYPE / QTY

Educational

LCN

VRE

• UL® & c-UL® Listed 1950 * Detailed meter specs available on pages 4 & 5.

VRE

LN1

00-1

Monitored

0 3C

-103

13T

C13

L6

Basic & Metered

5kW 30 Amp, 208 Volt

www.geistmfg.com

A T

1

2

3

4

Basic & Metered

30 Amp, 208 Volt, 5kW (x2) T L6 13D

L6

80- 1

2XP

2XP

BC4

XPB

B48

C30

0-10

0-10

3C1

0 3C

3DT

T L6 3IN6

L6 IN6T -103 300 XPB

2

3

4

1

1

2

2

30

30

30 x 2

30 x 2

VOLTS

208

208

208 x 2

208 x 2

30

48

48

C-13 / 24

C-13 / 24

C-13 / 48

C-13 / 48

RECEPTACLES PER INPUT

N/A

N/A

24

24

RECEPTACLES PER BREAKER

12

12

12

12

C-19 / 6

C-19 / 6

N/A

N/A

RECEPTACLES PER BREAKER MAGNETIC CIRCUIT BREAKER / ON-OFF

3

N/A

N/A

YES

YES

YES

20 / 2

20 / 4

20 / 4

DOUBLE

DOUBLE

DOUBLE

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS

NO

YES *

NO

YES x 2 *

MONITORING

N/A

AGGREGATE

N/A

AGGREGATE

NO

OPT *

NO

OPT *

CURRENT MONITORING - LOCAL AMPS - CIRCUIT 1, CIRCUIT 2, TOTAL

T

NO

OPT *

NO

OPT *

10’ POWER CORD

1

1

2

2

TWIST-LOCK PLUG

L6-30P

L6-30P

(2) L6-30P

(2) L6-30P

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

YES

YES

YES

YES

DIMENSIONS L (INCHES)

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

66.25

66.25

66.25

2

2

3.5

3.5

DIMENSIONS D

2

2

2

2

Resources

66.25

DIMENSIONS W

Educational

A

Brackets

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

Accessories

20 / 2 DOUBLE

BREAKER POLE CONFIGURATION

4

Software

BREAKER AMPERAGE / QTY

3 YES

3

Environmental

30

RECEPTACLE TYPE / QTY

2

Satellite

AMPS

1

Switched

1

QUANTITY OF INPUTS

RECEPTACLE TYPE / QTY

Monitored

LINE DRAWING

TOTAL RECEPTACLE QTY

Basic & Metered

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS Current Monitoring Option: Replace C with A in part number Current Monitoring Circuit 1, Circuit 2, & Total Option: Replace C with T in part number

A T

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

59

Basic & Metered

Switched Satellite

LINE DRAWING

Environmental

21 A12

XPB

XPB

123

-103

3-10

L20

3L2

T L2

0T L

1

21 3D2 3-10 A24

XPB

30 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

120

120

120

120

TOTAL RECEPTACLE QTY

24

24

12

12

5-20R / 24

5-20R / 24

L5-20R / 12

L5-20R / 12

8

8

4

4

YES

YES

YES

YES

20 / 3

20 / 3

20 / 3

20 / 3

DOUBLE

DOUBLE

DOUBLE

DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

PHASE/ BREAKER (X,Y,Z)

N/A

PHASE/ BREAKER (X,Y,Z)

BREAKER POLE CONFIGURATION

Software

T L2

4

30 x 3~

BREAKER AMPERAGE / QTY

Accessories

D20

3

30 x 3~

RECEPTACLES PER BREAKER AND PHASE

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L21-30P

L21-30P

L21-30P

L21-30P

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

Brackets

-103

2

30 x 3~

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Educational

243 1

AMPS

RECEPTACLE TYPE / QTY

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

YES

YES

YES

YES

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

2

2

DIMENSIONS D

2

2

2

2

MODIFY TO MEET YOUR NEEDS

Resources

Cord Length (Feet) 02-15 (Plug Attached)

60

XPB

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

0T L

1

Basic & Metered

8.6kW 30 Amp, 3 Phase

www.geistmfg.com

1

2

3

4

Basic & Metered

30 Amp, 3 Phase, 8.6kW

3IN6

L21 XPB

A30

3-10

IN6T -103 303 XPB

30 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

120

120

TOTAL RECEPTACLE QTY

30

30

C-13 / 24

C-13 / 24

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER AND PHASE MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

8 C-19 / 6

2

2

YES

YES 20 / 3 DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

MONITORING

N/A

PHASE/ BREAKER (X,Y,Z)

10’ POWER CORD

1

1

TWIST-LOCK PLUG

L21-30P

L21-30P

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

YES

YES

61.25 & 64.75

61.25 & 64.75

YES

YES

DIMENSIONS L (INCHES)

66.25

66.25

DIMENSIONS W

2

2

DIMENSIONS D

2

2

Educational

BREAKER DOGHOUSE - 1.44” DEPTH

Brackets

FULL-LENGTH VERTICAL MOUNTING BRACKET

Accessories

20 / 3 DOUBLE

BREAKER POLE CONFIGURATION

Software

BREAKER AMPERAGE / QTY

8 C-19 / 6

2

Environmental

RECEPTACLES PER BREAKER AND PHASE

1

Satellite

2

30 x 3~

Switched

1

AMPS

RECEPTACLE TYPE / QTY

Monitored

LINE DRAWING

T L2

1

Basic & Metered

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS

Resources

Cord Length (Feet) 02-15 (Plug Attached)

800-432-3219

61

Basic & Metered

Switched Satellite

LINE DRAWING

Environmental

21 A12

XPB

XPB

128

-103

8-10

L20

3L2

TL 2

0T L

1

21 8-10 A24

XPB

30 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

208

208

208

208

TOTAL RECEPTACLE QTY

24

24

12

12

6-20R / 24

6-20R / 24

L6-20R / 12

L6-20R / 12

8

8

4

4

YES

YES

YES

YES

20 / 3

20 / 3

20 / 3

20 / 3

DOUBLE

DOUBLE

DOUBLE

DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

CIRCUIT/ BREAKER (XY,YZ,ZX)

N/A

CIRCUIT/ BREAKER (XY,YZ,ZX)

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L21-30P

L21-30P

L21-30P

L21-30P

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

YES

YES

YES

YES

DIMENSIONS L (INCHES)

BREAKER POLE CONFIGURATION

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

2

2

DIMENSIONS D

2

2

2

2

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

Resources

DELTA Unit Configuration Option: 21= WYE L21-30P Plug / 15= DELTA L15-30P Plug

62

3D2

TL 2

4

30 x 3~

BREAKER AMPERAGE / QTY

Software

D20

3

30 x 3~

RECEPTACLES PER BREAKER AND PHASE COMBINATION

Accessories

-103 2

30 x 3~

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Brackets

248 1

AMPS

RECEPTACLE TYPE / QTY

Educational

XPB

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

0T L

1

Basic & Metered

8.6kW 30 Amp, 3 Phase

www.geistmfg.com

1

2

3

4

Basic & Metered

1 M46

XPW 249

-103

M14 XPB

339

-103

8-10 A30 XPB

T L2

1 T L2

TL 2 3IN6

L21 IN6T -103 308 XPB

2

3

4

30 x 3~

30 x 3~

30 x 3~

30 x 3~

VOLTS

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

120 / 208 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

208

208

120 & 208

120 & 208

TOTAL RECEPTACLE QTY

30

30

33

24

C-13 / 24

C-13 / 24

C-13 / 24

C-13 / 12

RECEPTACLE TYPE / QTY

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER AND PHASE COMBINATION

8

8

8

4

C-19 / 6

C-19 / 6

C-19 / 3

C-19 / 6

2

1

2

N/A

N/A

5-20R / 6

5-20R / 6

RECEPTACLES PER BREAKER AND PHASE

N/A

N/A

2

2

YES

YES

YES

YES

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY

20 / 3 DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

NO

MONITORING

N/A

CIRCUIT/ BREAKER (XY,YZ,ZX)

N/A

N/A

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L21-30P

L21-30P

L21-30P

L21-30P

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

YES

YES

YES

YES

DIMENSIONS L (INCHES)

FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

66.25

66.25

70

2

2

2

2

DIMENSIONS D

2

2

2

2

Resources

66.25

DIMENSIONS W

Educational

20 / 3 DOUBLE

Brackets

20 / 3 DOUBLE

4

Accessories

20 / 3 DOUBLE

BREAKER POLE CONFIGURATION

3

Software

2

RECEPTACLE TYPE / QTY

2

Environmental

RECEPTACLES PER BREAKER AND PHASE COMBINATION

1

Satellite

1

AMPS

Switched

LINE DRAWING

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Basic & Metered

1

30 Amp, 3 Phase, 8.6kW

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached) DELTA Unit Configuration Option: 21= WYE L21-30P Plug / 15= DELTA L15-30P Plug

800-432-3219

63

Basic & Metered

16.6kW 30 Amp, 3 Phase

Switched Satellite

LINE DRAWING

Environmental

S56

56

IN6P

6PS YBA

303

-103

03IN

VOLTS

230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

230 / 400 WYE

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

230

230

230

230

TOTAL RECEPTACLE QTY

30

30

30

30

C-13 / 24

C-13 / 24

C-13 / 24

C-13 / 24

8

8

8

8

C-19 / 6

C-19 / 6

C-19 / 6

C-19 / 6

2

2

2

2

YES

YES

YES

YES

BREAKER AMPERAGE / QTY

Software

03-1

30 x 3~

RECEPTACLES PER BREAKER AND PHASE

20 / 3

20 / 3

20 / 3

20 / 3

DOUBLE

DOUBLE

DOUBLE

DOUBLE

CURRENT MONITORING - LOCAL 3 PHASE SCROLLING

NO

YES *

NO

YES *

MONITORING

N/A

PHASE / BREAKER (X,Y,Z)

N/A

PHASE / BREAKER (X,Y,Z)

BREAKER POLE CONFIGURATION

Accessories

YB3

4

30 x 3~

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

Brackets

-103

3

30 x 3~

RECEPTACLE TYPE / QTY

10’ POWER CORD

1

1

1

1

TWIST-LOCK PLUG

L22-30P

L22-30P

N/A

N/A

N/A

N/A

30A, 230/400V 4P / 5W

30A, 230/400V 4P / 5W

IEC 60309 PIN & SLEEVE CONNECTOR FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

Educational

303 2

30 x 3~

RECEPTACLES PER BREAKER AND PHASE

Resources

YBA

1

AMPS

RECEPTACLE TYPE / QTY

YES

YES

YES

YES

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

YES

YES

YES

YES

DIMENSIONS L (INCHES)

66.25

66.25

66.25

66.25

DIMENSIONS W

2

2

2

2

DIMENSIONS D

2

2

2

2

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

64

L22

6T L

03IN

03-1 YB3

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

IN6T

22

Basic & Metered

aew 230/400V aew 230/400V aew 230/400V aew 230/400V

www.geistmfg.com

1

2

3

4

Basic & Metered

S15 IT6C -105 368 ZPB 1

AMPS

35 x 3~

VOLTS

208 DELTA

TOTAL RECEPTACLE QTY RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER AND PHASE COMBINATION

RECEPTACLES PER BREAKER AND PHASE COMBINATION MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY

10’ POWER CORD CALIFORNIA STYLE

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

10 C-19 / 6 2 YES 20 / 3 DOUBLE

1 50A, 250V 3P / 4W

Accessories

FULL-LENGTH VERTICAL MOUNTING BRACKET

36 C-13 / 30

Software

BREAKER POLE CONFIGURATION

208

Environmental

RECEPTACLE TYPE / QTY

1

Satellite

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

Switched

LINE DRAWING

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • Detailed wiring diagram available on page 181. • UL® & c-UL® Listed 60950

Basic & Metered

-35

35 Amp, 3 Phase, 10.1kW

YES 61.25 & 64.75 YES

DIMENSIONS L (INCHES)

66.25

DIMENSIONS W

2

DIMENSIONS D

2

Brackets

BREAKER DOGHOUSE - 1.44” DEPTH

Educational

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

Resources

800-432-3219

65

Basic & Metered

Switched

LINE DRAWING

Satellite Environmental

06C 19P S6

90- 1 ZP0

06C 19P S6

30- 1 ZP0

05C 19C S6

90- 1

50

50

60

60

208

208

208

RECEPTACLES PER BREAKER

BREAKER AMPERAGE / QTY

3

9

3

9

C-19 / 3

C-19 / 9

C-19 / 3

C-19 / 9

1

3

1

3

YES

YES

YES

YES

20 / 3

20 / 3

20 / 3

20 / 3

DOUBLE

DOUBLE

DOUBLE

DOUBLE

1

1

1

1

N/A

N/A

60A, 250V 2P / 3W

60A, 250V 2P / 3W

50A, 250V 2P / 3W

50A, 250V 2P / 3W

N/A

N/A

ADJUSTABLE HORIZONTAL MOUNTING BRACKETS

YES

YES

YES

YES

DIMENSIONS H (INCHES)

1.72

1.72

1.72

1.72

DIMENSIONS W

17

17

17

17

DIMENSIONS D

6.5

8.5

6.5

8.5

BREAKER POLE CONFIGURATION 10’ POWER CORD IEC 60309 PIN & SLEEVE CONNECTOR

Software

4

208

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

CALIFORNIA STYLE

Accessories

3

VOLTS

RECEPTACLE TYPE / QTY

MODIFY TO MEET YOUR NEEDS

Brackets

2

AMPS

TOTAL RECEPTACLE QTY

Resources

Educational

Cord Length (Feet) 02-15 (Plug Attached)

66

1

ZP0

• UL® & c-UL® Listed 60950

ZP0

30- 1

Monitored

05C 19C S6

Basic & Metered

8.3kW - 10kW 50 & 60 Amp, 208 Volt

www.geistmfg.com

1

2

3

4

Basic & Metered

60 Amp, 208 Volt, 10kW

PS6

S6

6IN6

IN6P

0-10 A30

-106

ZPB

300 ZPB 208

208

TOTAL RECEPTACLE QTY

30

30

C-13 / 24

C-13 / 24

8

8

C-19 / 6

C-19 / 6

2

2

YES

YES

20 / 3

20 / 3

RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER AND PHASE MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY BREAKER POLE CONFIGURATION

YES *

MONITORING

N/A

BREAKER

1

1

60A, 250V 2P / 3W

60A, 250V 2P / 3W

YES

YES

61.25 & 64.75

61.25 & 64.75

10’ POWER CORD IEC 60309 PIN & SLEEVE CONNECTOR FULL-LENGTH VERTICAL MOUNTING BRACKET TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

YES

YES

DIMENSIONS L (INCHES)

66.25

66.25

DIMENSIONS W

2

2

DIMENSIONS D

2

2

Educational

BREAKER DOGHOUSE - 1.44” DEPTH

Brackets

NO

Accessories

DOUBLE

Software

DOUBLE

CURRENT MONITORING - LOCAL SCROLLING

2

Environmental

VOLTS

1

Satellite

2 60

Switched

1 60

RECEPTACLES PER BREAKER AND PHASE

Monitored

LINE DRAWING AMPS

RECEPTACLE TYPE / QTY

Basic & Metered

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

MODIFY TO MEET YOUR NEEDS Cord Length (Feet) 02-15 (Plug Attached)

Resources

800-432-3219

67

Basic & Metered

Switched

LINE DRAWING

Satellite Environmental

5 PS1

5

C13

PS1

-106 ZPW 458

ZPB

248

-106

IBB

C19 -106 128 ZPB

60 X 3~

VOLTS

208 DELTA

208 DELTA

208 DELTA

208 DELTA

208

208

208

208

12

12

24

45

C-19 / 12

C-19 / 12

C-13 / 12

C-13 / 45

2

2

2

15

RECEPTACLE TYPE / QTY

N/A

N/A

C-19 / 12

N/A

RECEPTACLES PER BREAKER

N/A

N/A

2

N/A

YES

YES

YES

YES

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD BREAKER AMPERAGE / QTY

20 / 6

20 / 6

20 / 6

20 / 3

DOUBLE

DOUBLE

DOUBLE

TRIPLE

1

1

1

1

IEC 60309 PIN & SLEEVE CONNECTOR

60A, 250V 3P / 4W

60A, 250V 3P / 4W

60A, 250V 3P / 4W

60A, 250V 3P / 4W

2U RECESSED MOUNTING BRACKETS

YES

NO

NO

NO

FULL-LENGTH VERTICAL MOUNTING BRACKET

NO

YES

YES

YES

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES)

N/A

61.25 & 64.75

61.25 & 64.75

61.25 & 64.75

BREAKER DOGHOUSE - 1.44” DEPTH

N/A

NO

NO

YES

DIMENSIONS L/H (INCHES)

3.4

66.25

66.25

70

DIMENSIONS W

17

2.3

2.3

3

DIMENSIONS D

9

3.45

3.45

2

BREAKER POLE CONFIGURATION 10’ POWER CORD

MODIFY TO MEET YOUR NEEDS

Resources

Cord Length (Feet) 02-15 (Plug Attached)

68

PS1

9PS

4

60 X 3~

RECEPTACLES PER BREAKER

Software

6C1

3

60 X 3~

RECEPTACLE TYPE / QTY

Accessories

8-10 2

60 X 3~

TOTAL RECEPTACLE QTY

Brackets

R12 1

AMPS

OUTPUT VOLTAGE FOR 3 PHASE INPUT UNITS

Educational

2Z P

Monitored

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • Detailed wiring diagram available on page 181. • UL® & c-UL® Listed 60950

5

15

Basic & Metered

17.3kW 60 Amp, 3 Phase

www.geistmfg.com

1

2

3

4

Basic & Metered

80 & 120 Amp, 3 Phase, 23kW - 34.5kW E 0HW 15-B

E

XT3

9HW 15-B ZPB

048

-XX

8C1 -XX 128 ZPB

120 x 3~

VOLTS

208 DELTA

208 DELTA

208

208 DELTA

TOTAL RECEPTACLE QTY RECEPTACLE TYPE / QTY RECEPTACLES PER BREAKER

BREAKER AMPERAGE / QTY

4 L15-30R / 4

3

1

YES

YES

YES

YES

HARDWIRED CONNECTION OPENING

1.5” TRADE SIZE

1.5” TRADE SIZE

TERMINAL BLOCK ACCEPTS WIRE GAUGE

14 - 2/0

14 - 2/0

SUGGESTED BRANCH CIRCUIT BREAKER RATING

100A

150A

61.25 & 64.75

61.25 & 64.75

66.25

66.25

DIMENSIONS W

3.5

3.5

DIMENSIONS D

3.5

3.5

TOOLLESS MOUNTING HARDWARE CENTER TO CENTER SPACING (INCHES) DIMENSIONS L (INCHES)

Brackets

HARDWIRED - WIRING ACCESS PANEL - CONDUIT CONNECTION ACCESS

Accessories

30 / 4 TRIPLE

Software

20 / 4 TRIPLE

BREAKER POLE CONFIGURATION

2

Environmental

MAGNETIC CIRCUIT BREAKER / ON-OFF SWITCH WITH INTEGRAL GUARD

12 C-19 / 12

1

Satellite

2

80 x 3~

Switched

1

AMPS

OUTPUT VOLTAGE FOR 3 PHASE INPUT

Monitored

LINE DRAWING

Basic & Metered

• All 3 phase and multi-input units have color-coded receptacle configurations or labeling for easy identification and load balancing • Detailed wiring diagram for 80A unit available on page 181. • UL® & c-UL® Listed 60950

Educational Resources

800-432-3219

69

Inline Metered

Switched Satellite

20 -00C C19 2 20

VOLTS

120 or 208

120 or 208

1

1

C-13 / 1

C-19 / 1

NO

NO

YES *

YES *

AGGREGATE

AGGREGATE

CURRENT MONITORING - LOCAL AMPS - AGGREGATE

OPT *

OPT *

IEC POWER INLET

C-14

C-20 WITH CORD RETAINING CLAMP

PANEL MOUNTING INTEGRAL BRACKETS

YES

YES

RECEPTACLE TYPE / QTY

POWER MONITORING - LOCAL POWER FACTOR / AMPS / VOLTS / WATTS MONITORING

DIMENSIONS H (INCHES)

2.5

2.5

DIMENSIONS W

6.25

6.25

DIMENSIONS D

1.6

1.6

MODIFY TO MEET YOUR NEEDS

Resources

Educational

Brackets

Current Monitoring Option: Replace C with A in part number

70

-002

1 15

CIRCUIT BREAKER / ON-OFF SWITCH

Environmental

14

LINE DRAWING AMPS

TOTAL RECEPTACLE QTY

Software

-00C LCE

• UL® & c-UL® Listed 60950 * Detailed meter specs available on pages 4 & 5.

Accessories

C13 -001

Monitored

IEC inlet units allow the PDU to supply 120V, 208V or 230V. The voltage distributed is determined by the voltage input. (For a complete offering of IEC Cord Sets see page 169)

LCE

Basic & Metered

1.4kW - 3.3kW 15 & 20 Amp, 120 or 208 Volt

www.geistmfg.com

1

2

Notes

Notes

Basic & Metered Monitored

Switched

Satellite

Environmental

Software

Accessories

Brackets

Educational

Resources

71

800-432-3219