2015 11 4 12 10 54 906

Report 0 Downloads 228 Views
ES103

Thermostatic Bar Mixer with Diverter VICTORIA SHOWER Ⅴ

148.5mm 5 7/8" 205mm 8 1/16"

Ø 60mm Ø 2 3/8"

Ø 31mm Ø 1 1/4"

1500mm 59 1/16"

Dear Customer, We want to ensure that you get long-lasting satisfaction and pleasure from your fitting. Installation Therefore, please read the following care Flush piping system prior and after instructions because damage to the surface installation of fitting thoroughly and underlying material resulting from improper (consider EN 806) treatment is not covered by warranty. Refer to the dimensional drawing on fold-out l Do not use any abrasive sponges or scouring Refer to the installation step guide fig. [1-5] agents for cleaning. We also advise you not to The cold water supply must be connected on use cleaning agents containing solvent or acid, the right and the hot water supply onthe left. limescale removers, household vinegar and Open cold and hot water supplies and check cleaning agents with acetic acid in them. They connections for leak tightness. are aggressive to the surface and will leave Please check the installation for ensuring your fitting dull and scratched. As the formutations correct function. of commercially available cleaning agents frequently charge, we cannot guarantee they will provide the gentle care our fitting deserves. Clean the fitting with a little soap and a moist Maintenance cloth only, then simply rinse off and wipe dry. Shut off cold and hot water supply! You can avoid lime spots by drying the fitting each time it is used. Ⅰ Replace or clean the inlet accessories, see fig. [6]

Remove nut (A) anti-clockwise with monkey wrench, and take out the filter (B) to clean or replace if necessary. Clean or replace fittings (C), please just anti-clockwise screw off nut (A) with monkey wrench. Screw out internal part (C1) and remove check valve (C2) for cleaning or replacement if necessary.

80-380mm 3 1/8"-14 15/16"

Product Care

Ø 203mm Ø 8"

814mm 32 1/16"

Temperature --Hot water inlet (maximum) 90 ℃ Correct operation suggestion: --Hot water inlet temperature 55℃ ≤ T ≤ 65℃ --Recommended (energy saving) 60 ℃ --Cold water inlet temperature T ≤ 25℃ Water connection Cold-Right Hot-Left

Ⅲ Replace or clean the quarter turn cartridge, see fig. [8] Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver; Take out handle set (C); Screw off quarter turn cartridge (D) anti-clockwise with a monkey wrench; Replace cartridge (D).

71.5-76.5mm 2 13/16"-3"

84mm 3 5/16"

1bar 5bar 16bar

G1/2 On Off

90

150±25mm 5 7/8"±1" 2-Ø60mm 2-Ø2 3/8" 2 - G1 / 2B Ø39mm Ø1 9/16"

Pressure range: Minimum flow pressure Maximum operating pressure Air leakage pressure

G1/2B

Pressure range

370mm 14 9/16"

71.5mm 2 13/16" 32.5mm 1 1/4"

Can be used in conjunction with: Pressurised storage heaters, thermally and hydraulically controlled instantaneous heaters. Operation with low-pressure displacement water heaters is not possible.

Ⅱ Replace or clean the thermostatic cartridge, see fig. [7] Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver; Take out handle set (C) and limit ring (D); Screw off nut (E) anti-clockwise using a pin spanner, and then remove screw (F) using a 2mm Allen key; Replace cartridge (G).

42mm 1 5/8"

GB Application

Ø9mm Ø3/8" 262mm 10 5/16"



1

ES103

5

2

Connect the S-shaped connectors to pipe work and screw the fixation seat in place.

Install the thermostatic bar valve onto the inlet connectors.

6

Install hand shower

Replace or clean the inlet accessories

Ø6m m Ø1/ 4 "

C1 C2

Sugges1.1m(43 5/ 16" )

814mm (32 1/16")

RP551073

C

The flow restrictor is only needed when water pressure is above 5bar or where the hot water heater cannot keep up with the flow rate.

m 25m 1 5 0± 8 " ± 1 " 5 7/

30m

m

B A

sealing tape

3

7

4

Connect the shower kit to thermostatic bar valve.

Operate the product for a couple of minutes, varying both temperature and volume to determine correct operation.

8

Replace the thermostatic car tridge

Replace quar ter turn car tridge

2. 5 mm

5 6 3 4 2 29mm

1

B A

35mm

D

The flow restrictor is only needed when water pressure is above 5bar or where the hot water heater cannot keep up with the flow rate.

G F H2mm

E

Che cartridge is at

15

38C when the dot and groove/line are aligned.

Align the screw hole with the recess position on the cartridge.

m

m D

A

B

C

7