Minimum flow pressure 0.2bar Maximum operating pressure 5bar Air leakage pressure 16bar Temperature ---Hot water inlet (maximum): 90℃ Correct operation suggestion: --Hot water inlet temperature 55 ℃≤T≤65℃ --Recommended (energy saving) 60℃ --Cold water inlet temperature T≤25℃ Water connection cold-right Hot-left

mm " 62 /16 ∅ 27 ∅

m 0m " 19 1/ 2 ∅ 7 ∅

∅203 ∅8"

G1/2B

114mm 4 1/2"

Pressure range

400mm 15 3/4"

16 5/8"

Can be used in conjunction with: Pressurized storage heaters, thermally &hydraulically controlled instantaneous heaters and low-pressure displacement water heaters.

ES106

105mm 4 1/8"

Application

Product Care Dear Customer, We want to ensure that you get long-lasting satisfaction and pleasure from your fitting. Therefore, please read the following care instructions because damage to the surface and underlying material resulting from improper treatment is not covered by warranty. Do not use any abrasive sponges or scouring agents for cleaning. We also advise you not to use cleaning agents containing solvent or acid, limescale removers, household vinegar and cleaning agents with acetic acid in them. They are aggressive to the surface and will leave your fitting dull and scratched. As the formutations of commercially available cleaning agents frequently charge, we cannot guarantee they will provide the gentle care our fitting deserves. Clean the fitting with a little soap and a moist cloth only, then simply rinse off and wipe dry. You can avoid lime spots by drying the fitting each time it is used.

G1/2B

GB

Installation Flush piping system prior and after installation of fitting thoroughly (considering EN 806). Refer to the dimensional drawing on fold-out I. Refer to the installation step guide fig. [1-6] The cold water supply must be connected on the right and the hot water supply on the left. Open cold and hot water supplies and check connections for leak tightness.

147mm 5 13/16"

55-65mm 2 3/16"-2 9/16"

150-155mm 5 7/8"-6 1/8"

Maintenance Shut off cold and hot water supply!

8mm 3/8"

Replace thermostatic cartridge, see fig. [6] Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver. Take out handle set (C). Remove screw (D) using a 2.5 mm Allen key, and remove fixation base (E), washer (F), handle (G) and ring (H). Use a 48mm wrench to unscrew nut (Ⅰ) anti-clockwise. Replace cartridge (J). Reassemble in reverse order.

∅72mm 2 13/16"

Thermostatic Built-In Concentric Mixer GLYMUR SHOWER Ⅴ





1

ES106

2

Dismantle the mixer par ts shown.

4

Remove the fixation base.

5 Install the escutcheon plate, handle par ts and overhead shower.

2

m .5

Operate the product for a couple of minutes, varying both temperature and volume to determine correct operation.

Flow Restrictor

m

Installation position for flow restrictor. R P063154

The flow restrictor is only needed when water pressure is above 5bar or where the hot water heater cannot keep up with the flow rate.

R P122023

2.

5m

m

R P551073

R P027386 R P381048

R P426004 R P045042

2.5mm

R P9703078

R P027080

3 R P075016 R P055013

R P034094 R P024201 R P020103

R P027090

R P530076

R P024287

R P024276 R P026000

R P027128 R P043030 R P129000 R P058458

R P040000

R P058433

R P044539 R P518000

R P027002

R P027381

5 5 mm 150-1 6 1/8" 5 7/8"

R P038331- 91 R P034091

The distance should be decided based on the user's height and convenience. Suggested height is 1.1 m. (43 5/16'')

Connect the mixer's water inlets to pipes in wall. Use a spanner to tighten nuts to 35Nm (minimum).

R P044935- 90

Adjust handle to correct position when temperature is at 38℃. The cartridge is at 38℃ when the dot and groove/line are aligned.

R P024159 R P020041

Replace the thermostatic car tridge.

Min 1180m m Min 46 7/16''

Body

7

J I H

G

1.1 m 43 5/16''

R P025042 R P036120

R P020239 R P071058

Draw lines for Step 3 in accordance with the hole positions on the fixation base. Drill holes onto installation wall and fix the base. Suggested distance is 900mm. (35 7/16'')

R P078003 R P020001 R P032221 R P9703079

6

F

E C B A D 2.5mm

55-65mm (2 3/16"-2 9/16") Installation position





2.5mm