Flush piping system prior and after installation of fitting thoroughly ( considering EN 806) Refer to the dimensional drawing on fold-outⅠ Refer to the installation step guide fig. [1-4] The cold water supply must be connected on the right and the hot water supply on the left. Open cold and hot water supplies and check connections for leak tightness. Please check the installation for ensuring correct function.
Maintenance
39.5mm 1 9/16"
Dear customer, We want to ensure that you get long-lasting satisfaction and pleasure from your fitting.Therefore, please read the following care instructions because damage to the surface and underlying material resulting from improper treatment is not covered by warranty. Do not use any abrasive sponges or scouring agents for cleaning. We also advise you not to use cleaning agents containing solvent or acid, limescale removers, household vinegar and cleaning agents with acetic acid in them. They are aggressive to the surface and will leave your fitting dull and scratched. As the formutations of commercially available cleaning agents frequently charge, we cannot guarantee they will provide the gentle care our fitting deserves. Clean the fitting with a little soap and a moist cloth only, then simply rinse off and wipe dry. You can avoid lime spots by drying the fitting each time it is used.
69mm 2 11/16"
132mm 5 3/16"
53mm 2 1/16"
G1/2
150mm±25mm 5 7/8"±1"
ⅠShut off cold and hot water supply!
72mm 2 13/16"
Installation
Product Care
G1/2B
60 ℃ T ≤ 25℃ cold-right hot-left
Ⅲ Replace or clean the quarter turn cartridge, see fig. [7] Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver and take out washer(C); Take out handle set (D) and volume ring (E); Screw off quarter turn cartridge (F) anti-clockwise with monkey wrench; Replace cartridge (F).
∅6mm ∅ 1/4"
--Recommended (energy saving) --Cold water inlet temperature Water connection
119mm 4 11/16"
560mm 22 1/16" ∅64.5mm ∅ 2 9/16"
Temperature ---Hot water inlet (maximum) 90℃ Correct operation suggestion: --Hot water inlet temperature 55℃ ≤ T ≤ 65℃
70mm 2 3/4"
175mm 6 7/8"
1bar 5bar 16bar
78mm 3 1/16"
24.8mm 1"
1500mm 59 1/16"
Minimum flow pressure Maximum operating pressure Air leakage pressure
Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver and take out washer(C); Take out handle set (D), temperature ring (E) and fixation base (F); Screw off thermostatic cartridge (G) anti-clockwise using a pin spanner; Replace cartridge (G).
725mm 28 9/16"
Specifications
ⅡReplace or clean the thermostatic cartridge, see fig. [6]
∅ ∅
Can be used in conjunction with: Pressurised storage heaters, thermally and hydraulically controlled instantaneous heaters. Operation with low-pressure displacement water heaters is not possible.
∅ ∅
149mm 5 7/8"
Replace or clean the inlet accessories, see fig. [5]
287mm 11 5/16"
Remove nut (A) anti-clockwise with monkey wrench, and take out the washer (B); If replace connector (C) only, please just screw off nut (A) anti-clockwise with monkey wrench; After taking out washer (B), clean filter in the nut (A).
Thermostatic Bar Mixer with Sliding Set & Transparent Soap Dish RAVANA SHOWER Ⅴ
Ⅰ
1
ES108
Connect the S-shaped connectors to pipe work.
6
Replace the thermostatic car tridge
B
7
Replace quar ter turn car tridge
A
sealing tape C E
2
Install the thermostatic bar valve onto the inlet connectors.
5
Replace or clean the inlet accessories
C
RP551216
H 30
RP037083
E
B
Tighten thermostatic car tridge clockwise using monkey wrench. It shall be 38C when black marking in the car tridge grooves are in line with each other.