Flush piping system prior and after installation of fitting thoroughly ( considering EN 806) Refer to the dimensional drawing on fold-outⅠ Refer to the installation step guide fig. [1-4] The cold water supply must be connected on the right and the hot water supply on the left. Open cold and hot water supplies and check connections for leak tightness. Please check the installation for ensuring correct function.

Maintenance

39.5mm 1 9/16"

Dear customer, We want to ensure that you get long-lasting satisfaction and pleasure from your fitting.Therefore, please read the following care instructions because damage to the surface and underlying material resulting from improper treatment is not covered by warranty. Do not use any abrasive sponges or scouring agents for cleaning. We also advise you not to use cleaning agents containing solvent or acid, limescale removers, household vinegar and cleaning agents with acetic acid in them. They are aggressive to the surface and will leave your fitting dull and scratched. As the formutations of commercially available cleaning agents frequently charge, we cannot guarantee they will provide the gentle care our fitting deserves. Clean the fitting with a little soap and a moist cloth only, then simply rinse off and wipe dry. You can avoid lime spots by drying the fitting each time it is used.

69mm 2 11/16"

132mm 5 3/16"

53mm 2 1/16"

G1/2

150mm±25mm 5 7/8"±1"

ⅠShut off cold and hot water supply!

72mm 2 13/16"

Installation

Product Care

G1/2B

60 ℃ T ≤ 25℃ cold-right hot-left

Ⅲ Replace or clean the quarter turn cartridge, see fig. [7] Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver and take out washer(C); Take out handle set (D) and volume ring (E); Screw off quarter turn cartridge (F) anti-clockwise with monkey wrench; Replace cartridge (F).

∅6mm ∅ 1/4"

--Recommended (energy saving) --Cold water inlet temperature Water connection

119mm 4 11/16"

560mm 22 1/16" ∅64.5mm ∅ 2 9/16"

Temperature ---Hot water inlet (maximum) 90℃ Correct operation suggestion: --Hot water inlet temperature 55℃ ≤ T ≤ 65℃

70mm 2 3/4"

175mm 6 7/8"

1bar 5bar 16bar

78mm 3 1/16"

24.8mm 1"

1500mm 59 1/16"

Minimum flow pressure Maximum operating pressure Air leakage pressure

Lever out handle cap (A); Remove screw (B) using a cross-head screwdriver and take out washer(C); Take out handle set (D), temperature ring (E) and fixation base (F); Screw off thermostatic cartridge (G) anti-clockwise using a pin spanner; Replace cartridge (G).

725mm 28 9/16"

Specifications

ⅡReplace or clean the thermostatic cartridge, see fig. [6]

∅ ∅

Can be used in conjunction with: Pressurised storage heaters, thermally and hydraulically controlled instantaneous heaters. Operation with low-pressure displacement water heaters is not possible.

∅ ∅

149mm 5 7/8"

Replace or clean the inlet accessories, see fig. [5]

287mm 11 5/16"

Remove nut (A) anti-clockwise with monkey wrench, and take out the washer (B); If replace connector (C) only, please just screw off nut (A) anti-clockwise with monkey wrench; After taking out washer (B), clean filter in the nut (A).

Thermostatic Bar Mixer with Sliding Set & Transparent Soap Dish RAVANA SHOWER Ⅴ



1

ES108

Connect the S-shaped connectors to pipe work.

6

Replace the thermostatic car tridge

B

7

Replace quar ter turn car tridge

A

sealing tape C E

2

Install the thermostatic bar valve onto the inlet connectors.

5

Replace or clean the inlet accessories

C

RP551216

H 30

RP037083

E

B

Tighten thermostatic car tridge clockwise using monkey wrench. It shall be 38C when black marking in the car tridge grooves are in line with each other.

38 C

RP045137 RP531066 RP081032

8

D

m

A

C

17m

Suggested distance is 1. 1m (43 5/ 16’’).

RP025104

RP037084 RP081033 RP033058 RP530086 RP027399

RP053027

m

RP202221

m

RP075018 RP055017

RP045135 RP031312 RP058485 Rp518004 Rp045136 RP027398

19

F

RP063378

D

m

30

C

m

m

m

B

Cold

RP020332 RP040062

Please make sure that black marking in the cartridge grooves are in line with each other.

RP301000

3

Install hand shower,flow restrictor

4

Connect shower hose to bar valve.

9

Install the mixer par ts shown.

Flow restrictor



Install position for flow restrictor

6 ( 1 /4 ")

560 mm 22 1 / 16"

RP426004

Hot

A

The flow restrictor is only needed when water pressure is above 5bar or where the hot water heater cannot keep up with the flow rate.

Please make sure the four marked parts in picture are in line with each other.