Sy s S2 tem 00 p Se ro M rie s
14
S200 480Y/277 VAC Supplemental protectors
K
UL 1077 CSA C22.2 - NO. 235 VDE 0641 IEC-898 Cable & equipment protection
Rated current
Catalog number
List price
S201-K0.5 S201-K1 S201-K1.6 S201-K2 S201-K3 S201-K4 S201-K5 S201-K6 S201-K8 S201-K10 S201-K13 S201-K15 S201-K16 S201-K20 S201-K25 S201-K30 S201-K32 S201-K40 S201-K50 S201-K60 S201-K63
$ 42 42 42 42 42 42 42 42 42 42 42 42 42 42 46 48 48 52 60 68 68
Delivery class
Sugg. order qty
Wgt. oz. (1 pc.)
S201-K, 1 pole
S202-K, 2 pole S201-KNA, 1P+N
A
10
4.5
S203-K, 3 pole
S201-K0.5NA S201-K1NA S201-K1.6NA S201-K2NA S201-K3NA S201-K4NA S201-K6NA S201-K8NA S201-K10NA S201-K13NA S201-K16NA S201-K20NA S201-K25NA S201-K32NA S201-K40NA S201-K50NA S201-K63NA
84 84 84 84 84 84 84 84 84 84 84 84 88 90 96 112 130
S202-K0.5 S202-K1 S202-K1.6 S202-K2 S202-K3 S202-K4 S202-K5 S202-K6 S202-K8 S202-K10 S202-K13 S202-K15 S202-K16 S202-K20 S202-K25 S202-K30 S202-K32 S202-K40 S202-K50 S202-K60 S202-K63
96 96 96 96 96 96 96 96 96 96 96 96 96 96 106 106 106 116 136 152 152
B
5
9.0
S204-K, 4 pole S203-KNA, 3P+N
K 10,000 5000 1000 500 100 50
seconds
10 5 1 0.5
Delivery class
Sugg. order qty
Wgt. oz. (1 pc.)
0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 60 63
S203-K0.5 S203-K1 S203-K1.6 S203-K2 S203-K3 S203-K4 S203-K5 S203-K6 S203-K8 S203-K10 S203-K13 S203-K15 S203-K16 S203-K20 S203-K25 S203-K30 S203-K32 S203-K40 S203-K50 S203-K60 S203-K63
$ 138 138 138 138 138 138 138 138 138 138 138 138 138 138 156 158 158 174 200 228 228
A
1
13.5
0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63
S203-K0.5NA S203-K1NA S203-K1.6NA S203-K2NA S203-K3NA S203-K4NA S203-K6NA S203-K8NA S203-K10NA S203-K13NA S203-K16NA S203-K20NA S203-K25NA S203-K32NA S203-K40NA S203-K50NA S203-K63NA
200 200 200 200 200 200 200 200 200 200 200 200 206 212 224 264 304
B
1
18.0
S204-K0.5 S204-K1 S204-K1.6 S204-K2 S204-K3 S204-K4 S204-K6 S204-K8 S204-K10 S204-K13 S204-K16 S204-K20 S204-K25 S204-K32 S204-K40 S204-K50 S204-K63
218 218 218 218 218 218 218 218 218 218 218 218 234 238 260 300 338
14
4 pole
2 pole 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 60 63
List price
3 pole + neutral
1 pole + neutral 0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63
Catalog number
3 pole
1 pole 0.5 1 1.6 2 3 4 5 6 8 10 13 15 16 20 25 30 32 40 50 60 63
Rated current
A
5
9.0
AC 0.1
0.5 1 1.6 2 3 4 6 8 10 13 16 20 25 32 40 50 63
B
1
18.0
Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time
0.05 DC 0.01 1
2
3
5
8 10 12
20 30
multiple of rated current
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule CB5
14.9 1SXU 000 023 C0201
S
System pro M compact S ystem 2 Miniature circuit breakers 00 Se pro M S200, S200P, S200U, S200UP ries
14
Description
Features
The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are current limiting, DIN rail mounted and can offer a good equivalent to fused systems. The S2 is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to B, C, D, K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications.
• Current limiting • Fast breaking time (2.5 – 3.5 msec) • Unique bus connection system • Wide range of accessories • Available with variable depth handle mechanism • Optional Z curve for SCR protection • CE certified and marked
14
• DIN rail or front panel mounting • Finger safe terminals • Multi-function terminals • Suitable for reverse feed • 480Y/277VAC and 500VDC versions • UL489 Listed - branch circuit protective device. UL file # E212323 • UL1077 Recognized - supplemental protective device. UL file # E76126
ed
old M re nd u t a nia ers rs i d M reak ecto e t rov uit B Pro p Ap Circ ntal L U se me Ca pple Su
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
14.1 1SXU 000 023 C0201
M o pr ies em Ser st Sy 200 S
Technical data
14
S200-B
S200-C, -D
S200-K
Approvals: UL CSA VDE IEC
Item
1077 C22.2 — No.235 0641, 0660 898, 947
1077 C22.2 — No. 235 0660 898, 947
1077 C22.2 — No. 235 0660 898, 947
1077 — 0660 898, 947
No. of poles:
1,2,3,4 1+N,3+N
1,2,3, 1+N,3+N
1,2,3,4, 1+N,3+N
1,2,3,4,1+N,3+N
Tripping characteristic: Rated currents: Minimum operating voltage:
120VAC
C,D
K
K
0.5 to 63A
0.5 to 63A
0.2 to 63A
12V
12V
12V
Single pole
Multi pole
Single pole
Multi pole
Single pole
Multi pole
Single pole
Multi pole
10kA
—
10kA
—
10kA
—
10kA
— 10kA
240VAC
6kA
10kA
6kA
10kA
6kA
10kA
10kA
277VAC
6kA
—
6kA
—
6kA
—
10kA
—
—
6kA
—
6kA
—
6kA
—
10kA
277/480 VAC 60VDC
10kA
10kA
10kA
10kA
10kA
10kA
—
—
125VDC
—
10kA
—
10kA
—
10kA
—
—
Frequency:
50/60Hz (See below)
50/60Hz (see below)
50/60Hz (see below)
50/60Hz (see below)
240/415VAC 60VDC 415VAC 110VDC
240/415VAC 60VDC 415VAC 110VDC
240/415VAC 60VDC 415VAC 110VDC
240/415VAC 60VDC 415VAC 110VDC
Rated voltage IEC single pole IEC multi-pole
Protection category:
IP20
IP20
IP20
IP20
Depth of unit per DIN 43880:
68mm
68mm
68mm
68mm
Mounting position:
optional
optional
optional
optional
Standard mounting:
35mm DIN rail
35mm DIN rail
35mm DIN rail
35mm DIN rail
18-4 AWG [top] 18-8 [bottom] 17.5 in-lbs. #2 Posidrive
18-4 AWG [top] 18-8 [bottom] 17.5 in-lbs. #2 Posidrive
18-4 AWG [top] 18-8 [bottom] 17.5 in-lbs. #2 Posidrive
18-4 AWG [top] 18-8 [bottom] 17.5 in-lbs. #2 Posidrive
18-16 AWG 4.5 in-lbs. #1 Posidrive
18-16 AWG 4.5 in-lbs. #1 Posidrive
18-16 AWG 4.5 in-lbs. #1 Posidrive
18-16 AWG 4.5 in-lbs. #1 Posidrive
In < 32 A, 20,000 operations In > 32 A, 10,000 operations
In < 32 A, 20,000 operations In > 32 A, 10,000 operations
In < 32 A, 20,000 operations In > 32 A, 10,000 operations
In < 32 A, 20,000 operations In > 32 A, 10,000 operations
-25°C to +70°C -40°C to + 70°C
-25°C to +70°C -40°C to + 70°C
-25°C to +70°C -40°C to + 70°C
-25°C to +70°C -40°C to + 70°C
Shock resistance:
30g minimum of 2 impacts, shock duration of 13ms
30g minimum of 2 impacts, shock duration of 13ms
30g minimum of 2 impacts, shock duration of 13ms
30g minimum of 2 impacts, shock duration of 13ms
Vibration resistance:
5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ In
5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ In
5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ In
5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ In
6kA switching
6kA switching
6kA switching
—
Main and shunt trip terminals: Wire size
14
B 6 to 63A 12V
UL/CSA rated voltage & interrupting capacity
S200P-K
Torque Tool Accessory terminals Wire size Torque Tool Service life at rated load:
Ambient temperatures: Storage temperatures
Disconnecting neutral rating:
Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz applications. For frequencies other than 50/60Hz, the magnetic (instantaneous) trip values are increased by the factor given below: 16 2/3 - 60Hz 100Hz Approx. factor
1
1.1
200Hz
400Hz
DC
1.2
1.5
1.5
Thermal tripping is independent of frequency.
14.26 1SXU 000 023 C0201
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com
M o pr ies em Ser st Sy 200 S
Approximate dimensions S200, S200P, S200U, S200UP
14
00.00
Inches
00.00
[Millimeters]
S200 & S200P
S200U
S200UP
14
S290 Accessories mount to right side of MCB only
1.77 45
1.97
1.03
50
26
1.06 27
2.13 54
0.69 17.5
0.35
0.35
9
9
-H
-S
Auxiliary switch
Bell alarm
3.19 81 -A1, -A2 Shunt trip
14.30 1SXU 000 023 C0201
Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com