DO NOT SCALE THIS DRAWING
1
2g
4
3f
7803
05 SERIES - DEMOLITION / ENABLING WORKS 10 SERIES - SITE PLAN 15 SERIES - ENGINEERING WORKS 30 SERIES - ELEVATIONS 35 SERIES - SECTIONS 40 SERIES - ROOF LAYOUT & STRUCTURE 45 SERIES - INTERMEDIATE FLOOR JOIST LAYOUT 55 SERIES - FLAT LAYOUTS 60 SERIES - KITCHENS 65 SERIES - BATHROOM, EN-SUITE & WC 70 SERIES - SERVICES 75 SERIES - DETAILS 80 SERIES - WINDOWS 85 SERIES - SALES & LEGAL PLANS PEGRAM 1008 DRAWINGS - STRUCTURAL ENGINEER'S
6311
DASHED LINES DENOTE DOOR OPENING TO BE FORMED WHEN SITE WELFARE HAVE VACATED. REFER TO WH124/10/05.01 FOR SETTING OUT.
EXISTING DOUBLE DOORS DOOR TO BE USED UNTIL SITE WELFARE HAVE VACATED & TO BE REPLACED WITH NEW ALUMINIUM DOUBLE DOORS AS SHOWN ON WH124/10/80.01.
EXISTING SVP REPLACED WITH 150mm DIA SVP CW17
CW19
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL RELEVANT DRAWINGS:-
KEY PLAN (NTS)
RWP
NEW 300mm O/A CAVITY WALL CONSTRUCTION, 2 LEAFS 100mm 3.5N/mm² BLOCK (1950kg/m3 DENSITY) WITH 100mm CAVITY AND BLOWN INSULATION WITH 20mm ACRYLIC RENDER FINISH - COLOUR: WHITE
4146
*
NEW CAVITY WALL CONSTRUCTION TO MATCH AND LINE THROUGH WITH EXISTING
SERVICE RISER
EXISTING EXTERNAL WALL TO BE RETAINED
215
NEW R.C. COLUMN / WALLS- REFER TO PEGRAM 1008/A1 FOR DETAILS - COLUMNS TO SHOP FRONTAGE TO BE FINISHED EXTERNALLY WITH 20mm ACRYLIC RENDER - COLOUR: WHITE
215
M6
REFER TO 80.01 FOR NEW GLAZING DETAILS
W3
DASHED LINES DENOTE 215mm BLOCK WALL TO BE CONSTRUCTED WHEN SITE WELFARE HAVE VACATED. REFER TO PHASE 2 CONDOC FOR DETAILS.
RWP 60
60
W2
* *
REFER TO 80.01 FOR NEW GLAZING DETAILS
5110
SAP
W1
CW2
W1
RESIDENTIAL BIN STORE
CEILING 3115mm A.F.F.L
52.360 F.F.L.
M3 SAP
890
SAP
60
W2
M3
ALL DASHED PIPEWORK TO BE RUN UNDER 1ST FLOOR SLAB AND ABOVE PROPOSED CEILING LINE IN KITCHEN .
1398
60
REFER TO 80.01 FOR NEW GLAZING DETAILS
LEVEL DOOR THRESHOLD
M3
SVP/SAP RWP
RWP LOCATION CORE DRILL REQUIRED THROUGH EXISTING CONCRETE SLAB. NOTE: FLOOR THICKNESS VARIES. DRAINAGE OFFSET FROM ABOVE SVP TERMINATING WITH AIR ADMITTANCE VALVE ABOVE CEILING LEVEL
AAV
*
ANCON SPB FRAME CRAMPS (OR SIMILAR)
M1
303mm TOTAL CAVITY WALL THICKNESS 102.5 / 100 / 100 ( BRICK / CAVITY / BLOCK ) FACING BRICK FINISH
M2
300mm TOTAL CAVITY WALL THICKNESS 100 / 100 / 100 ( BLOCK / CAVITY / BLOCK ) RENDERED FINISH WITH 'M1' BELOW GLAZING LINE.
M3
328mm TOTAL CAVITY WALL THICKNESS 102.5 / 75 / 150 ( BRICK / CAVITY / BLOCK ) TO MATCH EXISTING FACING BRICK FINISH
M4
250mm TOTAL CAVITY WALL THICKNESS 102.5 / 47.5 / 100 ( BRICK / CAVITY / BLOCK ) FACING BRICK FINISH
M5
102.5 FACING BRICK PLINTH AROUND COLUMNS UPTO GLAZING LINE. REFER TO 35.02 DETAIL A FOR DETAILS. ACRYLIC RENDER APPLIED TO EXTERNAL FACE OF R.C. COLUMN ABOVE GLAZING LINE.
30 MIN. FIRE RATED PARTITION SEE 75-17 FOR DETAILS. 50mm GYPROC THERMALINE SUPER ON 10mm DABS - 60mm O/A DOT & DAB 'DRY-LINER BASIC' SYSTEM - GENERALLY TO ALL EXTERNAL MASONRY WALLS AND CONC. COLUMNS UNLESS NOTED OTHERWISE ON DRAWING
MJ
MOVEMENT JOINT
NEW RWP
G
NEW 65mm SQUARE PVCu RAIN WATER DOWN PIPE
M6
PARTY WALL - 215mm THICK BLOCK WALL ( BLOCKS LAID FLAT)
M7
AS M2 BUT NOT RENDERED AS INTERNAL WALL.
D
DRAINAGE AMENDED AS ADDENDUM No. 14384
C
SHOP FRONT & RESIDENTIAL DOOR OPENINGS AMENDED AS ADDENDUM No. 14381
B
CONTRACT DOCUMENT ISSUE
A
PRELIMINARY DOCUMENT ISSUE
GULLY LOCATION WINDOW / DOOR REFERENCES. REFER TO 80 SERIES FOR DETAILS.
Checked Prelim Issue
W1 60
SAP
Checked Condoc Issue
Author
Manager
Author
Manager
BS
JTG
MN
JTG
Date
Date
Date
Date
15/05/10
15/05/10
15/06/10
15/06/10
328
SAP
CW3
2314
DRAINAGE LOCATION 200mm Ø CORE DRILL REQUIRED THROUGH EXISTING CONCRETE SLAB - SVP = SOIL VENT PIPE, SAP = STUB STACK AT HIGHEST LEVEL. NOTE:- FLOOR THICKNESS VARIES SETTING OUT TAKEN FROM STRUCTURE.
*
W1 328
LINTEL ON PADSTONE OVER (REFER TO 05 SERIES DRG' s FOR SIZE AND SPECIFICATION.)
1) REFER TO 05 SERIES AND M. PEGRAM DRAWINGS FOR FOUNDATION DETAILS. 2) ALL WALLS BELOW GLAZING TO BE EXPOSED BRICK U.N.O. WITH PLINTHS WHERE SHOWN. 3) ALL NEW CAVITY WALLS TO RECEIVE FULL BLOWN GLASS FIBRE INSULATION.
* 60
*
15mm GYPROC WALLBOARD TEN DOT & DAB 'DRY-LINER BASIC' SYSTEM (OVERALL 25mm)
NOTE:SINGLE/ DOUBLE BLOCK LEAF WINDOW/ DOOR OPENING INFILL
DOOR LOCATIONS. REFER TO 55 SERIES FOR DOOR REFERENCES & 75.19 FOR DOOR JAMB DETAILS & 80 SERIES FOR DOOR DETAILS.
890
*
GYPROC THERMALINE SUPER 50 on 70 'C' STUDS AT 300 CENTRES. (OVERALL 120mm THICK)
MASONRY WALL CONSTRUCTION
CW1
60
W6
6mm PARGE COAT, 15mm GYPROC WALL BOARD TEN APPLIED VIA GYPLINER SYSTEM (OVERALL 30mm)
MN
328
(NOTE:- TO BE CONSTRUCTED IN PHASE 2)
W5
GYPROC HARDWALL PLASTER (13mm)
BS
5110
COMMERCIAL UNIT 1 (SITE WELFARE DURING CONSTRUCTION)
328
W4
GYPROC THERMALINE SUPER 50 APPLIED VIA GYPLINER SYSTEM TO ENCASE COLUMNS AND MASONRY REVEALS (OVERALL 60mm)
Checked By
890
890
W1
SAP
HATCH DENOTES PHASE 2 WORKS
2230
2230
CW1
*
NEW WINDOW / DOOR OPENING IN EXISTING STRUCTURE FOR DIMENSION REFER TO 05, 30 & 80 SERIES DRAWINGS.
REFER TO WH124/10/55.02 FOR FIT OUT OF SITE WELFARE OFFICES
5110
328
M3
60
6000
NEW 215mm WIDE 7N/mm² (1950kg/m3 DENSITY) BLOCK WALL WITH HEAD RESTRAINT BY ANCON (OR SIMILAR)
(NOTE:- TO BE CONSTRUCTED IN PHASE 2)
EXISTING STRUCTURE TO REMAIN - THICKNESS VARIES
60
NEW RWP
6000
W3
W1
*
F
3.5N/mm² BLOCKWORK (1950kg/m3 DENSITY)
COMMERCIAL BIN STORE
60
327
M3
W2
3316
M3
G
FACING BRICKS MATCHING EXISTING.
*
14.07.10
2939
*
14.07.10
163
*
15.06.10
60
SVP
GYPROC THERMALINE SUPER 50 APPLIED VIA GYPLINER SYSTEM TO MASONRY WALLS (OVERALL 60mm THICK)
15.05.10
S/S
THIS WALL THICKNESS TO MATCH EXISTING.
13
6000
60
SVP
W1
Date
13
MN
1148
60
NOTE:1) FIREFIGHTING STAIRCASES AND OUTSIDE OF LIFT SHAFTS TO BE FINISHED WITH 13mm HARDWALL PLASTER UNLESS SHOWN OTHERWISE. 2) ALL LINING THICKNESS ARE APPROXIMATE. DRY LINER TO ASSESS ON SITE TO ACHIEVE FLUSH FINISH WITH ADJOINING LININGS WHERE POSSIBLE. 4) DIMENSIONS TO BE READ IN CONJUNCTION WITH 55 SERIES DRAWINGS AND M.PEGRAM 1008 DRAWINGS, REFER TO 55 SERIES FOR PLOT AREAS. 5) ALL SERVICE PENETRATIONS THROUGH PARTY WALLS / FLOORS TO BE FIRE STOPPED PROVIDING MINIMUM 90 MINUTES FIRE PROTECTION WITH ROCKWOOL FIREPRO (OR SIMILAR)
MN
215
Description
1078
75
W3
1810
INTERNAL WALL LININGS
Revision
52
W1
3770
3770
NEW 300MM O/A CAVITY WALL CONSTRUCTION WITH FULL BLOWN INSULATION AND BRICK TO MATCH EXISTING
1252
DASHED LINES DENOTE 215mm BLOCK WALL TO BE CONSTRUCTED WHEN SITE WELFARE HAVE VACATED. REFER TO PHASE 2 CONDOC FOR DETAILS.
W2
*
SVP
100
60
H
60
LEGEND
SVP
W1
W4
Title
FORM DOOR OPENING 2100mm HIGH x 1033mm WIDE.
NOTE:- TEMPORARY
M1
*
Site
*
GROUND FLOOR PHASE 1 GENERAL ARRANGEMENT SHEET 1 of 3 Canon House, Wallington
Drg.
CW17
303
350
WH124/10/25-00 1033
W4
30
30 204 215
M6
1007
215 30
890
W4
60
215mm WIDE PARTY WALL LINED FLUSH WITH COLUMN
60
S/K-90 (1350)
W2
S/S
30
SVP
60
W1 M3
W2 RWP
M6 1398
W4
60
* 327
W4 30
327
* 890
E
NEW RWP
RODING EYE REFER TO DRAWING 15.01
30 215 30
1398
M3
CONTRACT DOCUMENT ISSUE
FORM DOUBLE DOOR OPENING 2100mm HIGH x 1810mm WIDE. 1810
Date
Drawn 150
Rev
May2010 BS
Scale
D
1:50@A1
FOR CONTINUATION REFER TO 25.01 The Weston Group Business Centre, Parsonage Road, Takeley, Essex. CM22 6PU. Tel: 01279 873333 Fax: 01279 873378
[email protected]