UNPACK THE FOLDED PLAY-PEN WITHOUT PRESSING ANY BUTTON.
POSITION AND ADJUST THE SECTIONS TO A HEXAGON. NOTE: THE DELUXE SUPERYARD SHOULD BE PLACED ON A FLAT SURFACE.
2
FIGURE 2
FIGURE 3 TO CONNECT END SECTION, ALIGN END SECTION WITH BOTH TOP AND BOTTOM HINGES CONNECTED IN POSITION.
TURN SECTIONS TO ALIGN HEXAGONAL MARK WITH ARROW ON OPPOSITE HINGE.
FIGURE 4A
FIGURE 4B INSERT THE BAR INTO GROOVE OF LOWER HINGE.
2
PRESS “A” DOWN AND SLIDE IT INTO UPPER HINGE.
A
1
FIGURE 4C
FIGURE 5
TURN EACH TOP HINGE TO MAKE BAR LOCK IN PLACE.
FINISH ASSEMBLY.
3
Operation TO OPEN
圍欄開門方法
6. Procedure to open gate: A. Press the release button.
B. Lift the gate panel upward. 6B
FIGURE 6A
C. Swing gate open. 6C
TO CLOSE 7.To close the door gate, release it and it will close automatically. Try this action several times and make sure: FIGURE 7A
7B
7C
upper lock rod upper locking housing
lock holder
OK lock holder
lower lock rod
A.The upper lock rod is completely latched within the lock holder at upper locking housing.
B.The lower lock rod of the gate panel fits securely into the lock holder of gate frame.
C.The mark on the left upper corner should be aligned with the mark on the upper locking housing.
NOTE: Always check to make sure the gate is securely lock after closing. 8. If the mark of left upper corner do not align with the mark of upper locking housing, please do the adjustments below to make certain that the door panel can be auto closed. If the upper locking housing moves toward the left, please release the screw on upper locking housing then press the door panel and upper locking housing to right and left sides until the two marks are aligned. Make sure the screw is retightened. FIGURE 8A left up corner
8B upper locking housing
door panel
8C NOTE: Please use two screwdrivers when tightening or untightening the screws.
4
If the upper locking housing moves toward the left, please release the screw on upper locking housing then press on the door panel and the upper locking housing until the two marks are aligned. Make sure the screw is retightened. 8D
left up corner
8E upper locking housing
door panel
If the upper locking housing moves upward, please release the screw on door lower hinge then press the door panel and the lower door hinge inwards until the two marks on the left corner are aligned. Make sure the screw is retightened. 8F
upper locking housing
8G
8H door lower hinge
If the upper locking housing moves downward, please release the screw on door lower hinge then press the door panel and door lower hinge to right and left sides until the two marks on the left corner are aligned. Make sure the screw is retightened. 8I
upper locking housing
8K
8J door lower hinge
HOLD-GATE-OPEN SYSTEM The hold-gate-open system is for adult use only. Once the gate is held open, the automatic closing feature of the gate will not work anymore, so your child could move back and forth without restriction. Swing the gate to the open positions to hold the gate open for easy access. FIGURE 9A Gate in closed position
9B
Swing to the open positions
9C
5
Assembly[configuregate] WALL MOUNTING Wall fittings - A side
Wall fittings - B side
Wall fittngs - A side
Wall fittngs - B side
NE
T LI
Wall fittings A
Wall fittings B
CU
Socket Cap-E
BOTTOM HINGE
BOTTOM HINGE
Lower hinge housing
Lower hinge holder
Floor Spacer-D INE TL
CU
OR
R
FLO
O FLO
10B
FIGURE 10A
10C
10D
10E
Locate the template vertical to the floor and mark the screw holes. Mount the wall fittings A, B, C onto the wall with screws included.
10F
Fix floor spacer-D to lower hinge housing. Fix socket cap-E to lower hinge holder.
NOTE: Please leave at least 0.4” from wall-fittings to the wall[11A]. Do not assemble the wall-fittings as [11B]
Wall
Wall
at least 0.4”
FIGURE 11A Wall fittngs - A side
Wall fittings-C
Wall fittngs - B side
11B Wall fittngs - A side
Wall fittings-C
Wall fittings-C
FIGURE 12A
Wall fittngs - B side
12B
Place panels on the mounted wall fittings.
12C
Wall fittings-C
12D
Insert removable vertical bars through wall fittings-C on the both sides of playpen, place the bars in lower hinge housings. 6