472-05.fm Page 5 Friday, October 27, 2000 8:19 AM
Back To Welcome
Contents
Group Metering & Meter Breakers Group Metering
January 2001
5-5
Vol. 1, Ref. No. [0137]
Group Metering — Meter Packs
Product Selection Meter Packs Table 5-2. Aluminum Bus Socket Ampere Rating
Number of Meter Sockets
Bus Ampacity
Main Tenant Breaker Type See Table 5-6
Catalog Number
Price U.S. $
Semi-flush Flange Kit Catalog Number
Price U.S. $
Ring Style Meter Socket Covers 1 125 4
26 3 4 56 66
200 400 400 600 600
Plug-on Type BR_ BRH_ BRHH_ —
1MP2122R 2 1MP3124R 1MP4124R 1MP5126R 1MP6126R
745.00 825.00 1,150.00 1,445.00 1,675.00
1MPSFK1 1MPSFK2 1MPSFK2 1MPSFK3 1MPSFK3
65.50 73.50 73.50 65.50 65.50
200 5
2 3 4 5 6
400 600 600 600 600
Bolt-on Type CC2_X CHH2_H2X CHH2_H4X CHH_X
1MP2204R 1MP3206R 1MP4206R 1MP5206R 1MP6206R
1,020.00 1,220.00 1,630.00 2,040.00 2,440.00
1MPSFK4 1MPSFK5 1MPSFK5 1MPSFK6 1MPSFK6
68.00 98.00 98.00 68.00 68.00
Ringless Style Meter Socket Covers 3 125
2 3 4 5 6
200 400 400 600 600
Plug-on Type BR_ BRH_ BRHH_ —
1MP2122RRL 2 1MP3124RRL 1MP4124RRL 1MP5126RRL 1MP6126RRL
745.00 825.00 1,150.00 1,445.00 1,675.00
1MPSFK1 1MPSFK2 1MPSFK2 1MPSFK3 1MPSFK3
65.50 73.50 73.50 65.50 65.50
200
2 3 4 5 6
400 600 600 600 600
Bolt-on Type CC2_X CHH2_H2X CHH2_H4X CHH_X
1MP2204RRL 1MP3206RRL 1MP4206RRL 1MP5206RRL 1MP6206RRL
1,020.00 1,220.00 1,630.00 2,040.00 2,440.00
1MPSFK4 1MPSFK5 1MPSFK5 1MPSFK6 1MPSFK6
68.00 98.00 98.00 68.00 68.00
Ringless Style Covers with Horn Bypass 3 125
2 3 4 5 6
200 400 400 600 600
Plug-on Type BR_ BRH_ BRHH_ —
1MP2122RRLB 2 1MP3124RRLB 1MP4124RRLB 1MP5126RRLB 1MP6126RRLB
900.00 1,055.00 1,455.00 1,815.00 2,125.00
1MPSFK1 1MPSFK2 1MPSFK2 1MPSFK3 1MPSFK3
65.50 73.50 73.50 65.50 65.50
200
2 3 4 5 6
400 600 600 600 600
Bolt-on Type CC2_X CHH2_H2X CHH2_H4X CHH_X
1MP2204RRLB 1MP3206RRLB 1MP4206RRLB 1MP5206RRLB 1MP6206RRLB
1,175.00 1,450.00 1,925.00 2,425.00 2,890.00
1MPSFK4 1MPSFK5 1MPSFK5 1MPSFK6 1MPSFK6
68.00 98.00 98.00 68.00 68.00
1 2 3 4 5 6
■ ■
Ring Style Meter Packs do not come with fifth jaw. Order 1MM5KJ if needed. Main lugs included. #6 – 300 kcmil. (Optional lugs are not available.) Fifth jaw factory installed at 9 o’clock position. To change in field from ring to ringless — order 1MMRC125. To change in field from ring to ringless — order 1MMRC200. To change from ring to ringless covers, the top socket only in 2, 5 and 6 socket designs — order 1MMRC125T. Top socket only — other sockets see
See Table 5-4 for Main Lug Kit Selection. See Table 5-5 for Wire Sizes.
Discount Symbol . . . . . . . . . . . . . . . . . . . . . . . 22-CD CAT.200.01.T.E
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
5
472-05.fm Page 4 Friday, October 27, 2000 8:19 AM
Back To Welcome
5-4
Contents
Group Metering & Meter Breakers Group Metering
January 2001 Vol. 1, Ref. No. [0136]
Group Metering — Meter Packs ■
■ ■
5 ■ ■ ■
■
Meter Pack
■
1MP units are self-contained (main terminal box included) for installations requiring up to six meter socket positions in a single enclosure. Units are not gangable with any other metering device. Approved by major power companies, UL listed, suitable as service equipment and meets the service and electrical requirements of EUSERC and CECHA. Series rating up to 100,000 AIC. All ringless cover devices include fifth jaw as standard. Ring type devices do not include fifth jaw as standard. Order 1MM5JK if needed. Bondable neutral. 120/240V AC, 1-phase 3-wire metering device.
■ ■ ■ ■
■ ■
Up to 600A maximum horizontal bus rating. Incoming lugs not included (phase A, phase B, and neutral). Indoor/outdoor construction. Provision for 2-pole breaker (plug-on type for 125A sockets and bolt-on type for 200A sockets) — circuit breakers not included. Underground incoming feed. For overhead feed, use Myers type hubs to ensure proper sealing.
Note: Cables must pass through meter socket bussing and then loop around to enter the line lugs.
1MP2122R, RRL and RRLB use DS Type hub. ■ Aluminum or copper bus. ❑
Product Selection Table 5-1. Meter Pack Catalog Numbering System
1 M P 4 12 4 R C 1-Phase
Bus Material
Type of Metering
Number of Meters
MP= Meter Pack
2, 3, 4, 5 or 6 Blank = Accessory
C = Copper Bus Blank = Aluminum Bus Security or Accessory Code R RRL RRLB LK SC
Ampere Rating 12 = 125 Amperes 20 = 200 Amperes Blank = Accessory
= = = = =
Ring Ringless Ringless with Horn Bypass Lug Kit (Accessory) Crimp Lug Landing Pad Kit (Accessory)
Bus Ampere Rating 2 4 6 Blank
= = = =
200 Amperes 400 Amperes 600 Amperes Accessory
When Ordering: 1. Determine catalog number of the basic device. 2. Include Lug Kit for incoming section. See Table 5-4. 3. Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page 5-7. 4. Select required accessories. See Pages 5-34 and 5-35.
For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog
CAT.200.01.T.E