5500 SERIES/HIGH VOLTAGE REED RELAYS

Report 1 Downloads 186 Views
5500 SERIES/HIGH VOLTAGE REED RELAYS 5500 Series High Voltage Reed Relays The 5500 Series High Voltage Reed Relays are ideally suited to the needs of Instrumentation, Industrial Process Controls and General Purpose requirements. The specification tables allow you to select the appropriate relay for your particular application. Applications include medical and hipot test instruments, and cable test equipment. If your requirements differ, please consult your local representative or Coto’s Factory. 5500 Series Features u High Dielectric Strength - 10,000 Volts isolation across contacts u High Contact Rating - 200 Watts u Hermetically sealed Tungsten contacts for long life u Magnetic Shield standard u Custom lead terminations and packages available u RoHS compliant

DIMENSIONS in Inches (Millimeters)

2.800 (71.12)

.710 (18.03) .750 (19.05)

.065 (1.65)

.700 (17.78) 1.000 (25.4)

.200 (5.08) .200 (5.08)

.700 (17.78)

.355 (9.02)

.033 DIA. (0.84) 1

2

3

4

Bottom View

Ordering Information Part Number Model Number 5501 5502 5503 5504

24 | page

tel: (401) 943.2686

|

XXXX-XX-1 Coil Voltage 05=5 volts 12=12 volts 24=24 volts

fax: (401) 942.0920

MODEL NUMBER Parameters

5501 Test Conditions

Units

55022

1 Form A

1 Form B

High Voltage Isolation

High Voltage Isolation

VDC

5

5503

55042

1 Form A

1 Form B

Load Switching Load Switching

COIL SPECS. Nom. Coil Voltage Max. Coil Voltage

12

24

5

12

24

5

12

24

5

12

24 30

VDC

6.5

15

30

6.5

15

30

6.5

15

30

6.5

15

+/- 10%, 25° C

Ω

40

175 575

40

175 575

40

175 575

40

175 575

Operate Voltage

Must Operate by

VDC - Max.

3.75 9.0 18.0 3.75 9.0 18.0 3.75 9.0 18.0 3.75 9.0 18.0

Release Voltage

Must Release by

VDC - Min.

0.5

Coil Resistance

1.0

2.0

0.5

1.0

2.0

0.5

1.0

2.0

0.5

1.0

CONTACT RATINGS Switching Voltage

Max DC/Peak AC Resist.

Volts

7500

7500

3500

3500

Switching Current

Max DC/Peak AC Resist.

Amps

3.0

3.0

3.0

3.0

Carry Current

Max DC/Peak AC Resist.

Amps

5.0

5.0

5.0

5.0

Max DC/Peak AC Resist.

Watts

50

50

200

200

Signal Level 1.0V, 10mA

x 10 Ops.

100

100

100

100

50mV, 10mA

Ω

0.080

0.080

0.200

0.200

Between all Isolated Pins at 100V, 25°C, 40% RH

Ω

1010

1010

1010

1010

pF

1.5

1.5

1.5

1.5

Contact Rating Life Expectancy-Typical

1

Static Contact Resistance (max. init.)

6

RELAY SPECIFICATIONS Insulation Resistance (minimum) Capacitance - Typical Across Open Contacts Dielectric Strength (minimum)

Between Contacts Contacts to Coil

VDC/peak AC VDC/peak AC

10,000 10,000

10,000 10,000

7,500 10,000

7,500 10,000

Operate Time including bounce

At Nominal Coil Voltage, 30 Hz Square Wave

msec.

3.0

3.0

3.0

3.0

msec.

3.0

3.0

3.0

3.0

Release Time - Typical

Top View: Grid = .1”x.1” (2.54mm x 2.54mm) 4

1

4

1 +

2

3

5501, 5503

2

3

5502, 5504

Notes: 1 2

Consult factory for life expectancy at other switching loads. This relay contains a bias magnet. Correct coil polarity must be observed.Models 5502 and 5504 susceptible to magnetic interaction due to bias internal magnet.

Environmental Ratings:

Storage Temp: -35°C to +100°C; Operating Temp: -20°C to +85°C; Solder Temp: 270°C max; 10 sec. max All electrical parameters measured at 25°C unless otherwise specified. Vibration: 20 G’s to 2000 Hz; Shock: 50 G’s

For most recent data visit www.cotorelay.com

COTO TECHNOLOGY, INC.

page | 25

2.0