5L FVN Series Fluorescent Luminaires

Report 5 Downloads 80 Views
1106-1107.qxp

12/16/2013

5L

6:55 PM

Page 1106

CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, Group IIC CI. II, Div. 1, Groups F, G CI. III & Simultaneous Presence

FVN Series Fluorescent Luminaires

Wet Locations NEMA 3, 3R

Applications: FVN Luminaires are ideal for use: • In areas made hazardous by the abnormal conditions resulting in the presence of flammable vapors or gases and combustible dusts as defined by the National Electrical Code® • Where broken lamps would damage machinery or processes, or harm people working in the area • In areas where stringent sanitation requirements exist

Features: • One-piece seamless sheet steel housing with welded end caps keeps dirt, dust and moisture away from ballast and lamps; easy to clean • A silicone rubber gasket provides a dust-tight seal between the lens/frame assembly and housing • Lens/frame assembly is hinged and wireway cover is held by safety chain for ease of lamp replacement and maintenance • Polyester powder coat finish provides high reflectance and corrosion resistance for long life and dependable service • Two 1/ 2" NPT pendant hubs and two 1/2" NPT thru-feed end hubs are standard • Electronic ballast is standard on 32 and 54 watt luminaires (/UNV only) FVN Fluorescent Luminaires with T5 HO lamps offer: • High lumen output per watt – provides energy savings versus other higher wattage fluorescent luminaires with similar lumen output • Longer lamp life and good lumen maintenance – reduced maintenance and lamp replacement costs

• • • • • • •

Luminaire housing – 20-gauge seamless sheet steel Lens/frame assembly – stainless steel Glass – 3/ 16" tempered Suspension flanges – seamless sheet steel Gaskets – silicone Lampholders – white thermoset plastic Clamps – stainless steel

Standard Finishes: • Reflector housings – corrosion-resistant white polyester powder coat • Lens/frame – natural

Dimensions In Inches: 40”

Certifications and Compliances:

5L

Standard Materials:

8 1/2”

• NEC and CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, Group IIC Class II, Division 1, Groups F, G Class III Simultaneous Presence (Cl. I and Cl. II) • UL Standards: 844 Hazardous (Classified) Areas 1598 Luminaires • CSA Standards: C22.2 No. 137

53 1/4”

7 1/4”

5 3/4”

15”

Ordering Information (Lamps not supplied): Lamp Watts

Line Voltage/Hertz

Lamp Type

32 32 40 40 40 60 60 60 60

120–277/50–60 347 / 60 120 / 50–60 277 / 60 347 / 60 120 / 60 277 / 60 347 / 60 220 / 50

T8 T8 T12 T12 T12 T12HO T12HO T12HO T12HO

Hub Size

2-Lamp Cat. #

3-Lamp Cat. #

/2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2 1 /2

FVN4232TG/UNV FVN4232TG/347 FVN4240TG/120 FVN4240TG/277 FVN4240TG/347 FVN4260TG/120 FVN4260TG/277 FVN4260TG/347 FVN4260TG/200 50

FVN4332TG/UNV FVN4332TG/347 FVN4340TG/120 FVN4340TG/277 FVN4340TG/347 — — — —

FVN4254TG/UNV FVN4254TG/347

— —

1

NPT NPT NPT NPT NPT NPT NPT NPT NPT

FVN Fluorescent Luminaires with T5 HO Lamps (Lamps not supplied) 1 54 120–277/50–60 T5HO /2 NPT 1 54 347 / 60 T5HO /2 NPT

1106

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1106-1107.qxp

12/16/2013

6:55 PM

Page 1107

FVN Series Fluorescent Luminaires

CI. I, Div. 2, Groups A, B, C, D CI. I, Zone 2, Group IIC CI. II, Div. 1, Groups F, G CI. III & Simultaneous Presence

5L

Wet Locations NEMA 3, 3R

Options: The following special options are available from the factory by adding suffix to luminaire Cat. No.: Description • Low temperature electromagnetic ballast, 40W rated 0°F (-18°C), 60W rated -20°F (-29°C)............................................................. • 45° angle brackets (field installed)........................................................................................................................................................ • Adjustable angle brackets (field installed)............................................................................................................................................ • Angle bars for chain suspension (field installed).................................................................................................................................. • Individually fused ballast (internal)........................................................................................................................................................ • Emergency lighting battery unit (Class I, Division 2 only). Also available for use with T5 lamps. Supplied with charging indicator light and instructions for use with a remote push-to-test station........................................................................................................

Suffix BY AG KH CX FB S799*

*If push-to-test operator installed in the luminaire is required, consult factory.

Temperature Performance Data: (Based on 40°C ambient) Cl. I, Div. 2 & Zone 2 Lamp 32W 40W 54W 60W

2-Lamp T5 T5 T3C T4

Class II

3-Lamp T5 T5 — —

2-Lamp T6 T6 T6 T6

Simultaneous Presence 3-Lamp

T6 T6 — —

2-Lamp T4 T4 T3C/T6 T4

3-Lamp T4 T4 — —

Supply Wire 60°C 60°C 75°C 90°C

Photometric Data: Luminaire with two 54W High Output T5 Linear Fluorescent Lamps FVN4254

5L

FVN .ies photometric files for use with our Luxicon® Lighting Layout Software are available from our website.

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

Copyright© 2013 Eaton’s Crouse-Hinds Business

1107

1108-1109.qxp

12/16/2013

5L

6:55 PM

Page 1108

Photometric Data

FVN Series Fluorescent Luminaires

Luminaire: FVN with 2-40W lamps (tempered lens) Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens:

2–40/T-12 0–30 1182 6300

Luminaire: FVN with 3–40W lamps (tempered lens)

0–40 0–60 0–90 1971 3555 4284

Lamp: Zonal Degrees: Zonal Lumens: Total Bare Lamp Lumens:

0–40 0–60 0–90 2834 5099 6079

All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass.

All data provided is for 2-lamp 40W RS cool white luminaires with tempered glass. Use 1.37 multiplier for 2-lamp 60W luminaires with tempered glass. Use .92 multiplier for 2-lamp 32W luminaires with tempered glass.

Coefficient of Utilization

Coefficient of Utilization

Effective Floor Cavity Reflectance 20%

Effective Floor Cavity Reflectance 20% Room Cavity Ratio 1 2 3

4

5

80

50 30 10

.682 .658 .637

.610 .572 .540

.546 .501 .466

.488 .438 .399

.439 .385 .346

.452 .399 .359

70

50 30 10

.668 .646 .625

.599 .563 .535

.538 .495 .462

.480 .433 .396

.430 .381 .343

.488 .444 .410

.439 .392 .357

50

50 30 10

.640 .622 .606

.576 .547 .521

.520 .454 .433

.464 .423 .391

.418 .374 .341

.528 .496 .468

.473 .435 .405

.426 .384 .353

30

50 30 10

.615 .601 .587

.556 .532 .511

.502 .472 .446

.450 .415 .386

.406 .367 .337

.568 .544 .526

.512 .484 .460

.459 .426 .399

.414 .378 .349

10

50 30 10

.594 .581 .570

.537 .517 .499

.487 .461 .439

.437 .406 .381

.394 .361 .333

.512

.447

.385

.336

0

0

.557

.487

.426

.368

.321

Room Cavity Ratio 6 7 8

9

10

% Reflectance Eff. Ceil. Wall

Room Cavity Ratio 6 7 8

9

10

80

50 30 10

.416 .359 .319

.375 .319 .281

.338 .283 .244

.309 .254 .217

.269 .215 .180

80

50 30 10

.396 .343 .305

.357 .304 .268

.322 .270 .234

.294 .242 .207

.256 .205 .172

70

50 30 10

.409 .356 .316

.370 .315 .278

.333 .281 .244

.305 .252 .217

.265 .215 .180

70

50 30 10

.390 .340 .302

.352 .301 .266

.317 .268 .233

.290 .240 .207

.252 .205 .172

50

50 30 10

.397 .350 .314

.359 .309 .276

.324 .277 .242

.297 .249 .215

.259 .211 .179

50

50 30 10

.378 .334 .300

.342 .295 .264

.309 .264 .231

.282 .237 .206

.247 .201 .171

30

50 30 10

.386 .344 .311

.348 .306 .273

.316 .272 .240

.289 .244 .214

.253 .208 .177

30

50 30 10

.368 .328 .298

.332 .292 .261

.301 .259 .230

.276 .233 .204

.241 .199 .169

10

50 30 10

.376 .338 .308

.341 .301 .271

.308 .268 .239

.282 .242 .212

.247 .205 .175

10

50 30 10

.358 .322 .294

.325 .288 .259

.294 .256 .228

.269 .231 .202

.235 .196 .168

0

0

.295

.258

.226

.200

.164

0

0

.283

.247

.217

.192

.157

% Reflectance Eff. Ceil. Wall

5L

3–40/T-12 0–30 1695 9450

Room Cavity Ratio 1 2 3

4

5

80

50 30 10

.721 .695 .673

.643 .603 .569

.575 .527 .489

.513 .459 .418

.461 .404 .362

70

50 30 10

.706 .683 .661

.631 .594 .564

.566 .520 .485

.505 .455 .415

50

50 30 10

.677 .657 .641

.607 .577 .549

.547 .508 .476

30

50 30 10

.650 .636 .621

.586 .561 .538

10

50 30 10

.627 .614 .602

0

0

.589

% Reflectance Eff. Ceil. Wall

1108

www.crouse-hinds.com

US: 1-866-764-5454

CAN: 1-800-265-0502

% Reflectance Eff. Ceil. Wall

Copyright© 2013 Eaton’s Crouse-Hinds Business