7-4 Air Conditioning Disconnects 7 - Main Electric Supply

Report 0 Downloads 132 Views
472_7.fm Page 4 Thursday, October 26, 2000 5:22 PM

Back To Welcome

7-4

Contents

Air Conditioning Disconnects January 2001 Vol. 1, Ref. No. [0224]

Technical Data and Specifications Table 7-1. Dimensions and Shipping Carton Information Description

Catalog Number

Height

Dimensions in Inches (mm) Width

Depth

Carton Quantity

Weight Lbs. (Kg)

DPF221R DPF222R DPU222R DPB222R

8.7 (220.89) 8.7 (220.89) 8.7 (220.89) 8.6 (218.35)

5.4 (137.16) 5.4 (137.16) 5.4 (137.16) 5.3 (134.62)

3.152 (80.03) 3.152 (80.03) 3.152 (80.03) 3.738 (94.95)

10 10 10 10

27 (12.26) 27 (12.26) 27 (12.26) 34 (15.44)

ACD221RNM ACD222RNM ACD222URNM B60NARNM

8.626 (218.99) 8.626 (218.99) 8.626 (218.99) 8.626 (218.99)

5 (126.95) 5 (126.95) 5 (126.95) 5 (126.95)

3.5 (88.86) 3.5 (88.86) 3.5 (88.86) 3.5 (88.86)

10 10 10 10

15 (6.81) 15 (6.81) 15 (6.81) 18 (8.18)

Metallic/Galvanized Steel Enclosure 30A Fused 60A Fused 60A Non-Fused 60A Molded Case Switch

Nonmetallic/Polycarbonate Enclosure

7

30A Fused 60A Fused 60A Non-Fused 60A Molded Case Switch

3.152 (80.1) 5.400 (137.2)

4.000 (101.6) 2.000 (50.8)

2.535 (64.4)

.250 (6.4)

1.110 (28.2)

1.465 (37.2)

5.140 (130.6) 8.794 (223.4)

8.700 (221)

5.260 (133.6)

.257 (6.5) Dia. 3 Holes Req'd. 1.650 (41.9)

1.130 (28.7) 2.394 (60.8)

5.254 (133.5)

1.090 (27.7) 1.000 (25.4)

1.550 (39.4)

1.550 (39.4) 5.100 (129.5)

2.965 (75.3) 7 Knockouts for 1/2 (12.7), 3/4 (19.1) or 1 (25.4) Conduit

.550 (14.0) 1.050 (26.7)

1.500 (38.1)

3.000 (76.2)

1.130 (28.7)

.281 (7.1) Diameter Knockout – 1 Req'd.

Figure 7-1. DPF221R, DPF222R and DPU222R Note: Refer to Page 7-6 for prices.

For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

CAT.200.01.T.E

472_7.fm Page 3 Thursday, October 26, 2000 5:22 PM

Back To Welcome

Contents

Air Conditioning Disconnects

7-3

January 2001 Vol. 1, Ref. No. [0223]

Features, Benefits and Functions ■ ■



■ ■ ■ ■



Standards and Certifications ■

Single-phase, 2-wire, 240V AC. NEMA 3R outdoor enclosures offered in metallic and nonmetallic versions. Easy-to-remove high strength protective shield for easier wiring and mounting. Easy-to-remove front-cover (no screws or fasteners to remove). 1-inch knockouts on the bottom, back and side of unit. Cu rated line and load lugs that are easily accessible. Ample wiring space for mounting with a stud gun (single keyhole, two or three-point mounting). Fused devices are service entrance rated.



UL Listed File No. E5239 Separate CSA Approved Unit

Contact us for details and part numbers for CSA Approved units.

Product Specifications Type 3R Rainproof Metallic Enclosure Provides Plenty of Knockout Sizes.

■ ■ ■ ■ ■ ■

Easily Accessible Neutral.

10,000 amperes rms symmetrical interrupting rating HP rated Fusible and non-fusible pullout and molded case switch designs. 30 and 60 amperes available in fusible 60 amperes available in non-fusible and molded case switch. Class H fuse clips provided on fusible pullout design.

Note: Fused nonmetallic units require the addition of GB4NM ground bar. ■ ■ ■ ■





Horsepower rated (10 hp maximum at 240V AC). Padlockable door provision for safety and reduction of tampering. Metallic enclosures are bottom entry and exit only. Nonmetallic enclosures have knockouts and a hub provision for top access. Nonmetallic enclosures have a single unit door and protective shield for installer convenience. Nonmetallic enclosures are durable and provide excellent resistance to climate changes.

Type 3 Rainproof Nonmetallic Enclosure Provides Durable Strength and Excellent Resistance to Climate Changes.

Pullout Handle Can be Stored in Enclosure in “Off” Position.

CAT.200.01.T.E

For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

7