Simplified method of calculating the BOOST current : -
Battery capacity (Ah) Mean consumption factor = 1.2 Actual charge duration = 10 h
Charger size = Ah*1.2 / 10
M 1206-xx-xxxx
Battery Voltage 12V
BOOST current 06A
Dimensions (mm.) 150*110*55
850
Battery capacity 40 to 80 Ah
M 1210-xx-xxxx
12V
10A
150*110*55
850
80 to 120 Ah
M 2405-xx-xxxx
24V
05A
150*110*55
850
35 to 75 Ah
Model
Weight ( g. )
SWITCH MODE BATTERY CHARGER
80W - 120W / 12V - 24V
FACTORY VOLTAGE SETTINGS: 12 V MODEL
Switch position
Battery type
B
classic lead acid classic lead acid seal lead acid / GEL
1 CURVE
2 CURVES A
24 V
U boost
U float
U boost
U float
14,2V
13,3V
28,4V
26,6V
14,2V
13,3V
28,4V
26,6V
14,4V
13,8V
28,8V
27,6V
INSTALLATION GUIDE Note Technique 1104N137
FOR THE 2 CURVES MODEL, THE DEFAULT SETTING - IS CURVE B
A fuse is provided to protect the unit in case of reverse polarity connection. Replace only with one that carries the same rating. WARNING ! During the BOOST phase the charger may become very hot. DO NOT TOUCH THE CHARGER ENCLOSURE 2 YEAR WARRANTY. The battery charger is warranted for a period of 2 years, including parts and labour, unless it has been incorrectly installed.
Page 4
REFERENCE
POWER (W)
U I (A) (V)
CONNECTIONS
OUTPUT(S)
CHARGING CURVES
BATTERIES TECHNOLOGY
M 1206 1L2 11 100
80
12
06
input wire/output wire
1
2
sealed and unsealed
M 1210 1L2 11 000
120
12
10
input wire/output wire
1
2
sealed and unsealed
M 1210 1L2 21 000
120
12
10
input IEC/output wire
1
2
sealed and unsealed
M 1210 2L2 11 000
120
12
10
input wire/output wire
2
2
sealed and unsealed
M 1210 2L2 21 000
120
12
10
input IEC/output wire
2
2
sealed and unsealed
M 2405 1L2 11 000
120
24
05
input wire/output wire
1
2
sealed and unsealed
M 2405 1L2 21 000
120
24
05
input IEC/output wire
1
2
sealed and unsealed
TOP UP Y WITH ENERG
ENERGY CONVERSION
32 route des Moulins - BP 116 74 410 Saint-Jorioz Tel. : + 33 (0) 4 50 68 96 22 Fax : + 33 (0) 4 50 68 96 34
FRANCE web : www.tecsup.fr E-mail : info @tecsup.fr
IDEAL FOR HARSH ENVIRONMENTS : - Watertight aluminium case - Wall mounted or flat sealed from harsh and corrosive environments greatly extending charger longevity
SPECIFICATIONS : - 1 or 2 output(s) patterns - No fan = no noise 3 states IUU type
- Protection index PI 54 - Input voltage : 230V
MICRO-TEC 80W-120W SWITCH MODE ELECTRONIC BATTERY CHARGERS
12 V / 06 A, 12 V / 10 A 24 V / 05 A Specifically designed to match the demanding requierements of high performance batteries used for on-board applications : yachts, special vehicles camping cars, ...
BENEFITS OF SWITCH MODE TECHNOLOGY : - Small, lightweight chargers, - consistent charge quality, regardless of any disturbances in the power input ( generator or mains ).
- Management and control by microprocessor
- Frequency : 50 / 60 Hz - Working temperature : -10°C to +45°C - Storage temperature : -20°C to +70°C - Charging curve selection by external SWITCH for 2 different battery types : ( classical lead open and sealed lead / gel ) - CE conformity / in compliance with european requirements user safety NF EN 60335-1 and EN 60335- 2-29 Electromagnetic compatibiliy ( E.M.C. ) : EN 50081-1, EN 50082-1, EN 55022 class A
SAFETY : - Electronic protection against output short-circuits against battery polarity inversion
FRONTAL DISPLAY / CONNECTIONS :
MICRO-TEC FEATURES : - To prolong the life of your batteries and conserve their initial capacity, the charger is programmed with 4 three-state charging patterns : > BOOST/Fast charge : restore maximum battery capacity in a short space of time. > ABSORPTION/Balanced charge : complements charge at maximum, gradually reducing the charging power. > FLOATING/Top-up charge : compensates for constant battery drain, while keeping the battery fully charged. - The MICRO-TEC allows the battery to be connected and used constantly, while still offering a real BOOST ( high voltage ) charge over short period. The charger switches back to top-up mode automatically.
- Information on the status of charge by LED : RED : BOOST / ABSORPTION GREEN : FLOATING - Connections : Input by wire length 1.5 m. and plug or IEC inlet ( check on picture ) Outputs by wires 2.5 mm² length 2 m.
OPTIONS : - On request : specific set up of current value I < I max
DIMENSIONS AND WEIGHT : SAFETY TIMEOUT CAPACITY Ah.
CURRENT VOLTAGE
BOOST
ABSORPTION
RED LED ON 0804DC112
FLOATING
GREEN LED ON
- Dimensions : 148 X 110 X 58 mm. - Poids : 850 gr.
INSTALLATION FITTING INSTALLATION The charger must be mounted vertically (to prevent water ingress, with the cables on the bottom ) or horizontally if in dry location. Maintain a free area of 15cm (6 ″) all around to allow air circulation for optimal cooling. Provide cool air input on the bottom and a hot air exhaust at the top. The charger will automatically regulate the output current to compensate for abnormal overheating. In case of critical overheating ( >60°C ), the charger will shut down. Disconnect the mains, wait approximately 10 minutes to allow the temperature to decrease, then reconnect the unit. CONNECTING THE BATTERIES: ( depend on the pattern – 1 or 2 outputs). Connect the red wire to the positive (+) post of the battery, and the black wire to the negative (-) post. Repeat the connection for battery n°2, in the case of a charger with 2 outputs. (The negative battery terminals must be connected together) Battery fuse : T e m p e re d g lass fuse
TECHNICAL SPECIFICATIONS Input voltage 230V ~ - 15% / + 10% Frequency 50/60Hz Output voltage U bat +/- 2% Output current I bat +/- 10% Natural cooling Protection index IP 54 Operating temperature -10/+45°C Storage temperature -20°C/+70°C User safety NF EN 60335-1 and EN 60335-2-29 Electromagnetic Compatibility (EMC) EN50081-1, EN50082-1, EN55022 class A.
WARNING : This is a class-A appliance. In a residential environment, this appliance can cause some radioelectrical perturbations. In this case it could be recommanded to the user to take some appropriated steps. General form of the charging curve Current Voltage Safety timeout ~12 hours
10A WARNING: Ensure that the battery connections to the charger are tight (loose wires can cause arcing and can cause a fire if not properly tightened). CONNECTING THE MAINS ( depend on the pattern ) The charger operates on mains 230Vac – 50Hz/60Hz.
DISPLAY Charge status of the charger is signalled with the following LED sequence: Red "Charge" Led : This led is lit as long as the battery is not fully charged Green "100%" Led :. This led is lit when the battery is fully charged
Absoption Boost RED Led ON
Floating GREEN Led ON
CHARGING CURRENT : The nominal current shown in the case of nominal voltage is the mean current supplied by the charger. It may be used continuously. SAFETY DEVICES ELECTRONIC PROTECTION against: - output short-circuits - battery discharge in the event of mains failure PROTECTION BY FUSE against: - mains input overload. - battery polarity inversion (exterior fuse) ANTI-CORROSION: casing in aluminium with anti-corrosion paint. ANTI-IMPACT : resistance to impacts in normal use.
CHARGING CURVE SELECTION
( OPTION ON A 12V/10A VERSION )
Remove the plastic round button to access the switches (refer to the curve selection tabulation) and using a sharp pen toggle the sliding switch (red) on the position you wish: A = Seal Lead Acid / Gel type battery UBoost = 14.4V (28.8V) / UFloat = 13.8V (27.6V) B = Classic Lead Acid UBoost = 14.2V (28.4V) / UFloat = 13.3V (26.6V) (For a 24V charger) PAGE 2
PAGE 3