82a-240 series - Torrco

Report 2 Downloads 103 Views
82-200/82A-240 series Bronze 3-Piece Full Port Ball Valve Solder End, 82-200 & 82-240: 600 CWP (psig), 150 SWP (psig). 82A-240: 400 CWP (psig), 150 SWP (psig). Vacuum Service to 29 inches Hg. MSS SP-110 compliant. CRN: OC10908.5C

FEATURES

• • • • •

OPTIONS AVAILABLE: (More information in Section J)

Adjustable packing gland Blow-out-proof stem design Reinforced seats Inline repairable Full port ball configuration

(SUFFIX) -01 -02 -04 -05 -07 -08 -10 -11 -14 -15 -16 -18 -19 -20 -21 -23 -24 -27 -30 -32 -35 -39 -40 -45 -46 -47 -48 -49 -50 -56 -57 -58 -59 -60 -92-

VARIATIONS AVAILABLE:

82-200 Series 82-240 Series 82A-240 Series

Standard 316 SS Ball & Stem 3” & 4” Only (No Options Available)

STANDARD MATERIAL LIST 1 2 3

Part Lever and grip Stem packing Stem bearing

4

Ball

5

Seat (2)

6

End cap (2)

7

Gland nut

8

Stem

9 10 11 12

Lever nut Body bolt Hex nut Body

product NUMBER 82-202-01 82-203-01 82-204-01 82-205-01 82-206-01 82-207-01 82-208-01 82-209-01 82A-240-01 82A-24A-01

SIZE 3/8" 1/2" 3/4" 1" 1.25” 1.5” 2" 2.5” 3” 4”

MATERIAL Steel, zinc plated w/vinyl MPTFE (Chevron style PTFE 82A 3”&4”) RPTFE ASTM B16 (Brass),chrome plated (1/4”-2.5”) ASTM 276-316 SS (3”-4”) RPTFE B16 (1/4” to 3/8”), B584-C84400 (1/2”-4”) B16 (Brass) ASTM B16 (Brass), ASTM 276-316 SS (3”-4”) Steel, zinc plated Steel, zinc plated Steel, zinc plated ASTM B584-C84400 (Bronze) A

B

0.44 0.56 0.83 1.00 1.25 1.50 2.00 2.50 3.00 4.00

1.28 1.40 1.71 1.93 2.37 2.62 3.01 3.62 4.18 5.43

C 2.56 2.81 3.43 3.87 4.75 5.25 6.03 7.25 8.37 10.86

D 1.81 1.93 2.18 2.62 2.87 3.37 3.68 5.14 8.10 8.88

E 3.87 4.87 4.87 5.50 5.50 8.00 8.00 9.75 19.13 19.13

OPTION Standard Configuration Static Grounded 2.25” Stem Extension Plain Ball Tee Handle 90º Reversed Stem SS Lever & Nut Therma-Seal™ Insulating Tee Handle Vented Ball Round Handle Vertical Chain Lever Plain Yellow Grip Lock plate Slot Vented Ball UHMWPE Seats Tank Flange Graphite Stem Packing Latch Lock Lever CamLock Handle SS Tee Handle & Nut PTFE Trim SS Hi-Rise Locking Wheel Handle, SS Nut Cyl-Loc & Grounded Less Lever & Nut Latch-Lock Lever - Lock in Closed Position Only SS Oval Latch-Lock Handle & Nut SS Oval Handle (No Latch) & Nut Assembled Dry 2.25” CS Locking Stem Extension Multifill Seats Oxygen Cleaned Chain Lever - Horizontal SS External Trim - 3-pc. Valves Grounded Ball & Stem Balancing Stop

SIZES All 3/8” to 4” 3/8” to 2” 3/8” to 4” 3/8” to 2” 3/8” to 4” 3/8” to 4” 1/4” to 2” 3/8” to 4” 3/8” to 2” 1/2” to 2” 3/8” to 2” 3/8” to 2” 3/8” to 4” 3/8” to 4” 2” ONLY 3/8” to 4” 1/2” to 2” 3/8” to 1.25” 3/8” to 2” 3/8” to 4” 3/8” to 1.25” 3/8” to 1/2” 3/8” to 4” 1/2” to 2” 3/8” to 3/4” 3/8” to 2” 3/8” to 4” 3/8” to 2” 3/8” - 4” 3/8” to 4” 3/8” to 2” 3/8” to 4” 3/8” to 4” 3/8” to 2”

For Pressure/Temperature Ratings, Refer to Page m-10, Graph No. 4

F

G

H

0.50 0.63 0.88 1.13 1.38 1.63 2.13 2.63 3.13 4.13

0.38 0.50 0.75 0.90 0.97 1.09 1.34 1.47 1.66 2.16

1.60 1.78 1.98 2.22 2.70 3.03 3.87 5.05 5.82 7.77

Wt. 1.04 1.55 2.27 3.28 5.62 8.07 14.42 26.61 43.00 106.00

Copyright ©2013 Apollo Valves, Manufactured by Conbraco Industries - Printed in the USA

B-5

flow data For Apollo® Ball Valves The listed Cv “factors” are derived from actual flow testing, in the Apollo® Ball Valve Division, Conbraco Industries, Inc., Pageland, South Carolina. These tests were completed using standard “off the shelf” valves with no special preparation and utilizing standard schedule 40 pipe. It should be understood that these factors are for the valve only and also include the connection configuration. The flow testing is done utilizing water as a fluid media and is a direct statement of the gallons of water flowed per minute with a 1 psig pressure differential across the valve/ connection unit. Line pressure is not a factor. Because the Cv is a factor, the formula can be used to estimate flow of most media for valve sizing.

flow of liquid

Q = CV



flow of gas

∆P SpGr

Q = 1360 CV

2 or ∆P = (Q) (SpGr) (Cv)2 Where: Q = ΔP = SpGr = Cv =



(∆P) (P2) (SpGr) (T)

-7 (T) (Q)2 or ∆P = 5.4 x 10 (SpGr) (Cv)2 (P2) Where: Q = ΔP = SpGr = P2 = T = Cv =

flow in US gpm pressure drop (psig) specific gravity at flowing temperature valve constant

flow in SCFH pressure drop (psig) specific gravity (based on air = 1.0) outlet pressure–psia (psig + 14.7) (temp. °F + 460) valve constant

Cv FACTORS FOR APOLLO VALVES size (in.) Valve 32-100/200 Series 64-100/200 Series 64W Series 70B-140 Series 70-100/200 Series 70-300/400 Series 70-600 Series 70-800 Series 71AR Series 71-100/200 Series 72-100/900 Series 73A-100 Series 73-300/400 Series 74-100 Series 75-100 Series 76AR Series 76F-100 Series 76-100 Series 76-300/400 Series 76-600 Series 7K-100 Series 77AR Series 77C-100/200 Series 77D-140 Series 77D-640 Series 77G-UL Series 77W Series 77X Series 77-100/200 Series 79 Series

1/4 5.1 6 -8.4 8.4 -2.3 8.4 ---8.4 -8.4 8.4 8.4 8.1 8.4 -2.3 -8.1 4.5 4.5 -4.5 --8.1 8.5

3/8 6.6 7 -7.2 7.2 -4.5 7.2 ---7.2 -7.2 7.2 7.2 15 7.2 -4.5 -15 7.2 7.2 -7.2 --15 8.5

1/2 8 19 -15 15 15 5.4 15 --26 15 26 15 15 15 15 15 26 5.4 15 15 16 16 -16 16 16 15 9.8

3/4 24 34 -30 30 30 12 30 30 30 48 30 48 30 30 30 51 30 48 12 51 51 36 36 11 36 36 36 51 32

1 30 50 -43 43 43 14 43 43 43 65 43 65 43 43 43 68 43 65 14 68 68 68 68 24 68 68 68 68 44

1.25 45 104 -48 48 48 21 48 48 48 125 48 125 48 48 48 125 48 125 21 125 125 125 125 35 125 125 -125 66

1.5

2

2.5

55 268 -84 84 84 34 84 84 84 170 84 170 84 84 84 177 84 170 34 177 177 177 177 -177 177 -177 148

95 309 -108 108 108­ 47 -108 108 216 108 216 108 108 108 389 108 216 47 389 389 389 389 -389 389 -389 218

-629 629 190 190 ---190 190 ---190 190 190 -190 --503 -503 --503 --503 440

3

4

-1018 1018 370 370 ---370 370 ---370 370 370 -370 -----------390

-1622 1622 670 670 --------670 670 670 ---------------

6 -------------------------------

8

10

12

-------------------------------------------------------------------------------------------continued on next page

Copyright ©2013 Apollo Valves, Manufactured by Conbraco Industries - Printed in the USA

M-3

flow data For Apollo® Ball Valves Cv FACTORS FOR APOLLO VALVES (continued from page M-3) size (in.) Valve 80/81 Series 82-100/200 Series 83A/83B Series 83R-100/200 Series 86A/86B Series 86R-100/200 Series 87A-100 Series 87A-200 Series 87A-700 Series 87A-900 Series 87B-100 Series 88A-100 Series 88A-200 Series 88A-700 Series 88A-900 Series 88B-100 Series 89-100 Series 9A-100 Series 91-100 Series 92-100 Series 93-100 Series 94A-100/200 Series 95-100/200 Series 95A-300/400 Series 96-100 Series 399-100 Series 489-100 Series

M-4

1/4 8.4 8.1 8.1 -8.1 -----------8.4 8.3 8.3 8.3 8.3 6 --8.3 8.4 8.4

3/8 7.2 14 14 -14 -----------7.2 6.7 6.7 6.7 6.7 7 --6.7 7.2 7.2

1/2 15 26 26 -26 --15 -15 --15 -15 -15 5.7 5.7 5.7 5.7 19 15 19 5.7 15 15

3/4 30 51 51 -51 --19 -19 --19 -19 -30 10 10 10 10 34 51 34 10 30 30

1 43 68 68 -68 --75 -75 --75 -75 -43 16 16 16 16 50 68 50 16 43 43

1.25 48 120 120 -120 -----------48 25 25 25 25 104 --25 48 48

1.5

2

2.5

84 170 170 170 170 170 86 195 86 195 -86 195 86 195 -84 40 40 40 40 268 --40 84 84

108 376 376 376 376 376 104 410 104 410 -104 410 104 410 -108 62 62 62 62 309 --62 108 108

190 510 ----234 545 234 545 -234 545 234 545 -190 ----629 ---190 190

www.apollovalves.com

3

4

6

8

10

12

370 996 -996 -996 375 1021 375 1021 375 375 1021 375 1021 375 370 ----1018 ---370 370

-1893 -1893 -1893 673 2016 673 2016 673 673 2016 673 2016 673 -----1622 ------

------1099 4837 1099 4837 1099 1099 4837 1099 4837 1099 ------------

------1902 9250 1902 9250 1902 1902 9250 1902 9250 1902 ------------

------3890 15170 3890 15170 3890 3890 15170 3890 15170 3890 ------------

-------22390 -22390 --22390 -22390 -------------

Customer Service (704) 841-6000

pressure temperature ratings 400# Bronze (GRAPH 3)

600# Bronze (GRAPH 4)

M-10

www.apollovalves.com

Customer Service (704) 841-6000