890 cy

Report 1 Downloads 106 Views
OLFLEX® FD 890/ 890 CY Super Flexible Heavy Duty Continuous Flex Cable UL Type MTW Approved Cable OLFLEX® FD 890 is a super flexible, heavy duty, multi-conductor cable designed for continuous flex applications. Superior stranding, specially formulated PVC insulation and jacket compounds optimize flex life and provide excellent resistance to mineral oils, synthetic oils and water based coolants. OLFLEX® FD 890 is rated 600V, 90oC with UL Type MTW conforming to NFPA 79 2007 standards for machine wiring and is also UL and CSA AWM approval. Recommended Applications: Gantry robots, Cable tracks, Pick and place units, Conveyor systems, Machine tools and Other continuous flexing applications.

Application Advantage: • Over 15 years of time tested performance to the most rigorous of industrial plant continuous flex applications • Meets UL Oil Res I/II for long service life, resistant to harsh environments • Pressure extruded jacket for precision connectorization • Conforms to latest approvals of North American Machine Tool compliance requirements

OLFLEX® FD 890 Construction: Finely stranded bare copper conductors; specially blended PVC insulation; dry lubricant; conductors cabled with non-wicking textile wrap over outer layer; specially formulated UV and oil resistant PVC jacket.

OLFLEX® FD 890 CY Construction: Finely stranded bare copper conductors; specially blended PVC insulation; dry lubricant; conductors cabled with non-wicking textile wrap; black inner PVC jacket; tinned copper braid (85% coverage); specially formulated UV and oil resistant PVC jacket.

Cable Attributes Oil Resistance: OR-04

Flame Resistance: FR-02

Motion Type: CF-02

Mechanical Properties: MP-02

Also available with blue and black conductors; minimum order required.

Technical Data: Minimum Bending Radius 7.5 x cable diameter - for continuous flexing: 10 x cable diameter - with shield:

Color Code: Red with numbered cores, plus green/yellow ground Optional: Other color codes available upon request

Temperature Range: - for flexible use: - for stationary use:

Approvals: -5oC to +90oC -40oC to +90oC

Nominal Voltage:

UL/CSA: 600V CE: 300/500V

Test Voltage:

3000V

Conductor Stranding:

Super Fine Wire, better than VDE 0295, Class 6

UL:

- Type MTW, Oil Res I & II - UL- AWM 2587 + 21098 - Passes Oil Res + UL 758 80oC test - CSA-AWM I/II A/B FT 1 CSA: - Passes CSA C22.2 210.2 - Sec. 7.6.12.1, 8.8.8- Oil Resistance Tests Additional: - Conforms to NFPA 79 2007 - Based on VDE Specifications - NOM SCFI-1994

* Passes Impact and Crush tests to UL 1277 Same requirement for Exposed Run

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com © 2008 Lapp Group

OLFLEX® FD 890/ 890 CY Super Flexible Heavy Duty Continuous Flex Cable UL Type MTW Approved Cable OLFLEX FD® 890: Super Flexible Heavy Duty Continuous Flex Control Cable Part Number

Number of Conductors includes ground

20 AWG (74/38) 0.50 mm2 892003 3 892004 4 892005 5 892007 7 892012 12 892018 18 892025 25 892034* 34 18 AWG (114/38) 1.00 mm2 891803 3 891804 4 891805 5 891807 7 891812 12 891815 15 891818 18 891825 25 891834* 34 16 AWG (182/38) 1.50 mm2 891603 3 891604 4 891605 5

Nominal Outer Diameter inches mm

Copper Weight lbs/mft

Approx. Weight lbs/mft kg/km

.290 .316 .341 .394 .450 .526 .670 .756

7.4 8.0 8.7 10.0 11.4 13.4 17.0 19.2

10 13 17 23 40 60 83 113

47 53 69 78 122 179 262 339

.315 .344 .372 .432 .497 .588 .617 .742 .826

8.0 8.7 9.5 11.0 12.6 14.9 15.7 18.8 20.4

19 25 31 44 75 94 113 156 213

50 63 78 103 157 212 235 327 434

.353 .387 .421

9.0 9.8 10.7

27 36 45

86 107 133

Part Number

Number of Conductors includes ground

891607 7 891612 70 12 891618 79 18 891625 102 25 891634* 116 34 891650* 182 50 891660* 266 60 391 14 AWG (320/38) 2.50 mm2 891404 504 4 891407 7 75 12 AWG (511/38) 4 mm2 891204 94 4 891207 116 7 153 10 AWG (343/34) 6 mm2 891004 234 4 317 8 AWG (301/32)10 mm2 890804 350 4 487 6 AWG (483/32) 16 mm2 890604 646 4 4 AWG (768/32) 25 mm2 890404* 129 4 159 2 AWG (1026/32) 35 mm2 890204* 198 4

Nominal Outer Diameter inches mm

Copper Weight lbs/mft

Approx. Weight lbs/mft kg/km

.492 .603 .705 .899 .925 1.094 1.190

12.5 15.3 17.9 22.8 23.5 27.8 30.2

64 109 163 227 309 454 544

141 247 332 504 623 880 1076

211 367 495 751 927 1309 1602

.449 .611

11.4 15.5

60 105

146 226

217 337

.510 .695

12.9 17.7

60 105

200 315

298 469

.631

16.0

147

277

413

.794

20.2

245

513

765

.924

23.5

589

721

1074

1.059

26.9

541

1005

1496

1.252

31.8

691

1240

1846

* AWM Only- Part Numbers: 892034, 891834, 891634, 891650, 891660, 890404, 890204 are AWM only and do not comply with NFPA 79 2007.

OLFLEX FD® 890 CY: Shielded Super Flexible Heavy Duty Continuous Flex Control Cable Part Number

Number of Conductors includes ground

20 AWG (74/38) 0.50 mm2 892003CY 3 892004CY 4 892005CY 5 892007CY 7 892012CY 12 892018CY 18 892025CY 25 892034CY* 34 18 AWG (114/38) 1.00 mm2 891803CY 3 891804CY 4 891805CY 5 891807CY 7 891812CY 12 891818CY 18 891825CY 25 891834CY* 34 16 AWG (182/38) 1.50 mm2 891603CY 3 891604CY 4 891605CY 5

Nominal Outer Diameter inches mm

Copper Weight lbs/mft

Approx. Weight lbs/mft kg/km

.368 .394 .419 .472 .583 .659 .778 .874

9.4 10.0 10.6 12.0 14.8 16.7 19.8 22.2

10 13 17 23 40 60 83 113

88 103 111 138 226 294 408 495

131 154 165 206 337 438 608 737

.393 .422 .450 .565 .630 .716 .912 .986

10.0 10.7 11.4 14.4 16.0 18.2 23.2 25.0

19 25 31 44 75 113 156 213

95 113 132 198 268 356 538 660

142 168 197 295 400 530 801 984

.431 .465 .499

10.9 11.8 12.7

27 36 45

121 154 169

181 229 252

Part Number

Number of Conductors includes ground

891607CY 7 891612CY 12 891618CY 18 891625CY 25 891634CY* 34 891650CY* 50 14 AWG (320/38) 2.50 mm2 891404CY 4 891407CY 7 12 AWG (511/38) 4 mm2 891204CY 4 891207CY 7 10 AWG (343/34) 6 mm2 891004CY 4 8 AWG (301/32) 10 mm2 890804CY 4 6 AWG (483/32) 16 mm2 890604CY 4 4 AWG (768/32) 25 mm2 890404CY* 4 2 AWG (1026/32) 35 mm2 890204CY* 4

Nominal Outer Diameter inches mm

Copper Weight lbs/mft

Approx. Weight lbs/mft kg/km

.625 .702 .829 1.023 1.067 1.260

15.9 17.8 21.1 26.0 27.1 32.0

64 109 163 227 309 454

258 366 495 706 769 1265

385 546 737 1051 1145 1883

.582 .710

14.8 18.0

60 105

191 347

285 518

.643 .819

16.3 20.8

60 105

242 494

361 735

.739

18.8

147

333

496

.964

24.5

245

766

1142

1.048

26.6

589

969

1444

1.227

31.2

541

541

2065

1.430

36.3

691

691

2510

* AWM Only- Part Numbers: 892034CY, 891834CY, 891634CY, 891650CY, 890404CY, 890204CY are AWM only and do not comply with NFPA 79 2007.

800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com The products and specifications set forth in this brochure are subject to change without notice and Lapp Group disclaims any and all liability for such variations. Lapp Group further disclaims any and all liability for typographical, printing, or production errors or changes affecting the products and/or the specifications. © 2008 Lapp Group