90 series configuration - SupplyHouse.com

Report 0 Downloads 76 Views
90 SERIES

CONFIGURATION

1F92-371/1F93-380/1F94-371/1F95-371/1F95-377

Customizing Your Comfort-Set Thermostat

The following tables allow you to customize the options on your Comfort-Set thermostat. Begin by pressing simultaneously the two buttons in step 1.

User Menu 1F92 Step 1

1F931F95 1

Press Button(s) TIME and TIME

FWD BACK

2

2

TIME

FWD

3

3

TIME

FWD

4

4

TIME

FWD

5

5

TIME

FWD

6

6

TIME

FWD

7

7

TIME

FWD

N/A

8

TIME

FWD

N/A

9

TIME

FWD

N/A

10

TIME

FWD

N/A

11

TIME

FWD

8

12

PROGRAM

Displayed (Factory Default)

Press

or

to select:

COMMENTS

0°F (room temperature)

5 LO to 5 HI

Adjusts temperature display higher or lower.

EMR (ON)

OFF or ON L

Selects EMR option ON or OFF or L ON.

°(F)

°C

SET FAN (0)

0 - 6 HRS

BEEP (ON)

OFF

Turns keypad beeper ON or OFF.

HEAT FAST (OFF)

ON

OFF delays starting second stage for economy. ON starts second stage earlier with user intervention.

COOL FAST (OFF)

ON

OFF delays starting second stage for economy. ON starts second stage earlier with user intervention.

TEMP OUT (OFF)

ON

FONE (Icon) (OFF)

ON

Enables outdoor temperature sensor. Requires optional remote sensor connected to terminal OT and remote thermistor probe. Also displays outdoor temperature if active. Telephone RUN program feature. Requires optional X10 system.

COMP RUN TIME (00)

(Compressor run time in hours)

Shows accumulated time compressor has run. To reset to 00, press and .

AUX RUN TIME (00)

(AUXILIARY run time in hours)

Shows accumulated time AUXILIARY has run. To reset to 00, press and .

Adjusts temperature display to °F or °C. Set Fan (one shot) option. Set the duration of a temporary fan option.

Returns to normal operation.

RUN

Keypad LockoutMenu Menu(access (accessfrom fromUser UserMenu) Menu above) Keypad Lockout

TECHNICAL HELP

1F92 Step

1F931F95

Press Button(s)

Displayed (Factory Default)

TIME FWD and TIME BACK (hold for two seconds)

PART LOCK (OFF)

ON

Partial Keypad lockout OFF or ON.

LOCK (OFF)

ON

Total Keypad lockout OFF or ON.

1

1

2

2

TIME

3

3

PROGRAM

166

FWD

Press

or

to select:

COMMENTS

Returns to normal operation.

RUN

www.white-rodgers.com

Ref Page

90 SERIES

CONFIGURATION

1F92-371/1F93-380/1F94-371/1F95-371/1F95-377

NOTE:

Step Step Step Step Press Button(s) N/A N/A

1

2

1

N/A

2

TIME FWD (Heat Pump ONLY)

3

2

1

3

TIME

FWD

4

3

2

4

TIME

FWD

5

4

3

5

TIME

FWD

6

5

N/A

6

TIME FWD (Heat Pump ONLY)

7

6

4

7

TIME

FWD

8

7

5

8

TIME

FWD

9

8

6

9

TIME

FWD

10

9

N/A

10

TIME FWD (Heat Pump ONLY)

11

10

7

11

TIME

FWD

12

11

8

12

TIME

FWD

13

12

9

13

TIME

FWD

N/A

13

10

14

TIME

FWD

N/A

14

11

15

TIME

FWD

N/A

15

12

16

TIME

FWD

N/A

16

13

17

TIME

FWD

14

at the same time

INSTALLER MENU

For Step #1 press SET TIME and SET DAY (hold for approx. 3 seconds)

1

and TIME

Displayed (Factory Default)

Press

or

to select:

COMMENTS Selects type of system. Selecting HEAT PUMP makes additional menu items for heat pump system available.

MLTI STG HP for 1F92

HEAT PUMP MS for 1F92

HEAT PUMP (1)

2 or 3

Selects: 1. one compressor on Y1. 2. two compressors on Y1, Y2. 3. one compressor on W1.

ELECT HEAT FAN (ON)

OFF

Fan cycles with call for heat if ON. Fan always cycles with pump stages.

SET CYCLE HEAT (5 for multi-stage 13 for heat pump)

1 to 40 for multi-stage 9 to 40 for heat pump

Selects HEAT anticipation adjustment.

SET CYCLE COOL (13)

9 to 40

Selects COOL anticipation adjustment.

SET CYCLE AUX (06)

1 to 40

Selects AUXILIARY stage anticipation adjustment. (Heat Pump ONLY)

COOL FAN DELAY OFF (00)

0 to 127 seconds

FAN DELAY ON (01)

1 to 30 seconds

Selects time delay for fan ON. Applies only to compressor stages for heat pump or COOL.

HEAT FAN DELAY OFF (00)

0 to 127 seconds

Selects time delay for HEAT fan OFF only when ELECT HEAT FAN (Step 3) is ON.

PUMP (ON)

OFF

Fossil Fuel Kit Alternative option. Turns compressor OFF if Auxiliary is ON for longer than one minute. (Heat Pump 1 & 2)

COMP LOCK (OFF)

ON

Selects compressor short-cycle protection enabled or OFF.*

ECON (OFF)

ON

Economizer option. Long Y1 cycles for cooling with outdoor air

HEAT-OFF-COOL-AUTO or HEAT-EMER-OFF-COOLAUTO (for heat pumps)

HEAT-OFF-COOL or HEAT-EMER-OFF-COOL (for heat pumps)

Selects time delay for COOL fan OFF.

REM SEN A (OFF)

ON

Allows selection of HEAT and COOL or HEAT, COOL and AUTO with SYSTEM button. (EMER appears in sequence after HEAT if HEAT PUMP is selected.) Selects Remote Sensor A (connected to SA) if ON.

REM SEN b (OFF)

ON

Selects Remote Sensor B (connected to SB) if ON.

REM SEN C (OFF)

ON

Selects Remote Sensor C (connected to SC) if ON.

STAT SEN L (ON)

OFF

When OFF, disables local sensor if a remote sensor is enabled.

TECHNICAL HELP

1F93-380 1F95-377

1F95-371

1F94-371

1F92-371

You must be in the User Configuration Menu to enter the Installer Menu. Press TIME and then proceed to the table below.

Returns to normal operation

PROGRAM RUN

* NOTE: COMP LOCK OFF permanently defeats compressor lockout. You must turn this selection ON if you do not have a system that already provides compressor short-cycle protection. Please see “Lockout Bypass Option” to temporarily override compressor lockout.

www.white-rodgers.com