The following tables allow you to customize the options on your Comfort-Set thermostat. Begin by pressing simultaneously the two buttons in step 1.
User Menu 1F92 Step 1
1F931F95 1
Press Button(s) TIME and TIME
FWD BACK
2
2
TIME
FWD
3
3
TIME
FWD
4
4
TIME
FWD
5
5
TIME
FWD
6
6
TIME
FWD
7
7
TIME
FWD
N/A
8
TIME
FWD
N/A
9
TIME
FWD
N/A
10
TIME
FWD
N/A
11
TIME
FWD
8
12
PROGRAM
Displayed (Factory Default)
Press
or
to select:
COMMENTS
0°F (room temperature)
5 LO to 5 HI
Adjusts temperature display higher or lower.
EMR (ON)
OFF or ON L
Selects EMR option ON or OFF or L ON.
°(F)
°C
SET FAN (0)
0 - 6 HRS
BEEP (ON)
OFF
Turns keypad beeper ON or OFF.
HEAT FAST (OFF)
ON
OFF delays starting second stage for economy. ON starts second stage earlier with user intervention.
COOL FAST (OFF)
ON
OFF delays starting second stage for economy. ON starts second stage earlier with user intervention.
TEMP OUT (OFF)
ON
FONE (Icon) (OFF)
ON
Enables outdoor temperature sensor. Requires optional remote sensor connected to terminal OT and remote thermistor probe. Also displays outdoor temperature if active. Telephone RUN program feature. Requires optional X10 system.
COMP RUN TIME (00)
(Compressor run time in hours)
Shows accumulated time compressor has run. To reset to 00, press and .
AUX RUN TIME (00)
(AUXILIARY run time in hours)
Shows accumulated time AUXILIARY has run. To reset to 00, press and .
Adjusts temperature display to °F or °C. Set Fan (one shot) option. Set the duration of a temporary fan option.
Returns to normal operation.
RUN
Keypad LockoutMenu Menu(access (accessfrom fromUser UserMenu) Menu above) Keypad Lockout
TECHNICAL HELP
1F92 Step
1F931F95
Press Button(s)
Displayed (Factory Default)
TIME FWD and TIME BACK (hold for two seconds)
PART LOCK (OFF)
ON
Partial Keypad lockout OFF or ON.
LOCK (OFF)
ON
Total Keypad lockout OFF or ON.
1
1
2
2
TIME
3
3
PROGRAM
166
FWD
Press
or
to select:
COMMENTS
Returns to normal operation.
RUN
www.white-rodgers.com
Ref Page
90 SERIES
CONFIGURATION
1F92-371/1F93-380/1F94-371/1F95-371/1F95-377
NOTE:
Step Step Step Step Press Button(s) N/A N/A
1
2
1
N/A
2
TIME FWD (Heat Pump ONLY)
3
2
1
3
TIME
FWD
4
3
2
4
TIME
FWD
5
4
3
5
TIME
FWD
6
5
N/A
6
TIME FWD (Heat Pump ONLY)
7
6
4
7
TIME
FWD
8
7
5
8
TIME
FWD
9
8
6
9
TIME
FWD
10
9
N/A
10
TIME FWD (Heat Pump ONLY)
11
10
7
11
TIME
FWD
12
11
8
12
TIME
FWD
13
12
9
13
TIME
FWD
N/A
13
10
14
TIME
FWD
N/A
14
11
15
TIME
FWD
N/A
15
12
16
TIME
FWD
N/A
16
13
17
TIME
FWD
14
at the same time
INSTALLER MENU
For Step #1 press SET TIME and SET DAY (hold for approx. 3 seconds)
1
and TIME
Displayed (Factory Default)
Press
or
to select:
COMMENTS Selects type of system. Selecting HEAT PUMP makes additional menu items for heat pump system available.
MLTI STG HP for 1F92
HEAT PUMP MS for 1F92
HEAT PUMP (1)
2 or 3
Selects: 1. one compressor on Y1. 2. two compressors on Y1, Y2. 3. one compressor on W1.
ELECT HEAT FAN (ON)
OFF
Fan cycles with call for heat if ON. Fan always cycles with pump stages.
SET CYCLE HEAT (5 for multi-stage 13 for heat pump)
Selects time delay for fan ON. Applies only to compressor stages for heat pump or COOL.
HEAT FAN DELAY OFF (00)
0 to 127 seconds
Selects time delay for HEAT fan OFF only when ELECT HEAT FAN (Step 3) is ON.
PUMP (ON)
OFF
Fossil Fuel Kit Alternative option. Turns compressor OFF if Auxiliary is ON for longer than one minute. (Heat Pump 1 & 2)
COMP LOCK (OFF)
ON
Selects compressor short-cycle protection enabled or OFF.*
ECON (OFF)
ON
Economizer option. Long Y1 cycles for cooling with outdoor air
HEAT-OFF-COOL-AUTO or HEAT-EMER-OFF-COOLAUTO (for heat pumps)
HEAT-OFF-COOL or HEAT-EMER-OFF-COOL (for heat pumps)
Selects time delay for COOL fan OFF.
REM SEN A (OFF)
ON
Allows selection of HEAT and COOL or HEAT, COOL and AUTO with SYSTEM button. (EMER appears in sequence after HEAT if HEAT PUMP is selected.) Selects Remote Sensor A (connected to SA) if ON.
REM SEN b (OFF)
ON
Selects Remote Sensor B (connected to SB) if ON.
REM SEN C (OFF)
ON
Selects Remote Sensor C (connected to SC) if ON.
STAT SEN L (ON)
OFF
When OFF, disables local sensor if a remote sensor is enabled.
TECHNICAL HELP
1F93-380 1F95-377
1F95-371
1F94-371
1F92-371
You must be in the User Configuration Menu to enter the Installer Menu. Press TIME and then proceed to the table below.
Returns to normal operation
PROGRAM RUN
* NOTE: COMP LOCK OFF permanently defeats compressor lockout. You must turn this selection ON if you do not have a system that already provides compressor short-cycle protection. Please see “Lockout Bypass Option” to temporarily override compressor lockout.