90 SERIES

TYPICAL WIRING

1F90-371/1F96-344/1F97-371/1F97-391 TYPICAL WIRING DIAGRAMS JUMPER WIRE

JUMPER WIRE 6

MV

B

Y

O

G

NOTE

W

Fan Relay

RED jumper wire (provided with thermostat) must be connected between thermostat's RH and RC terminals for proper thermostat operation with this system.

RC

RH

Heating System

THERMOSTAT

6

MV

SYSTEM

B

Y

O

G

B

24 VAC

G

Cooling System

Fan Relay

W

RC

RH

JUMPER WIRE 6

THERMOSTAT

MV

SYSTEM

Y

G

Cooling System

B

Y

O

JUMPER WIRE

G

W

RC

THERMOSTAT

RH

SYSTEM

Changeover Compressor Fan Relay* Contactor Relay

Hot

Hot

* Changeover relay is energized when the system switch is in the COOL position

120 VAC

W

RC

JUMPER WIRE 6

RH

B

Y

G

W

Cooling System

Fan Relay

Heating System

O

NOTE

SYSTEM

24 VAC

RED jumper wire (provided with thermostat) must be connected between thermostat's RH and RC terminals for proper thermostat operation with this system.

120 VAC Neutral

HEATING TRANSFORMER

Fan Relay

MV

RC

RH

Hot 24 VAC

TRANSFORMER

6

MV

B

Y

O

G

W

RC

RH

THERMOSTAT SYSTEM

COOLING TRANSFORMER

Figure 3. Typical wiring diagram for heat/cool, 5-wire, two-transformer systems

Millivolt System

NOTE Thermostat must have batteries installed.

1 Y

G

W

HM2

RC

120 VAC Neutral

120 VAC Neutral

6

SYSTEM

Figure 8. Typical wiring diagram for heat/cool, 4-wire, single transformer systems

Hot 24 VAC

HM1

THERMOSTAT

THERMOSTAT Hot

Heating System

120 VAC

Neutral TRANSFORMER

Figure 7. Typical wiring diagram for heat pump with cool active reversing valve

Figure 2. Typical wiring diagram for cool only, 3-wire, single transformer systems

O

120 VAC

Neutral TRANSFORMER

Figure 6. Typical wiring diagram for heat pump with heat active reversing valve

TRANSFORMER

B

Hot

* Changeover relay is energized when the system switch is in the HEAT position

120 VAC

Neutral

MV

SYSTEM

24 VAC

24 VAC

6

THERMOSTAT

RH

24 VAC

Neutral

Y

O

RC

Hot

Figure 1. Typical wiring diagram for heat only, 3-wire, single transformer systems MV

W

Changeover Compressor Fan Relay* Contactor Relay

TRANSFORMER

6

JUMPER WIRE

RH

Figure 9. Typical wiring diagram millivolt systems

HM

HM1 W RH RC G

Y

HM2 6

TECHNICAL HELP

HUMIDIFIER

NOTE: Two terminal choices (HM1 or HM2) are provided for humidifier control. When the humidity setting is higher than the room humidity: HM1 turns off the humidifier when the call for heat ends. HM2 powers the humidifier an additional 30 seconds after the call for heat ends to provide slightly more humidity output. Most installers will use HM1 unless they feel more humidity is desirable. 6

HM1

Y

G

W

HM2

➊ From humidity system Figure 4. Typical wiring diagram for 24V humidifier system

6

MV

6 Zone Valve 1

4 5

Y

G

W

RC

RH

2

NOTE Thermostat must have batteries installed.

THERMOSTAT SYSTEM

Hot 120 VAC Neutral TRANSFORMER

Figure 10. Typical wiring diagram heat only, 3-wire zone valve systems 1 RC

RH

HM

HM1 W RH RC G

Y

HM2 6

➊ From humidity system

Figure 5. Typical wiring diagram for 120V humidifier system 156

O

24 VAC

Relay 90-290Q or equivalent

HUMIDIFIER

B