PHOTOCOPIED/SCANNED INFORMATION NB This drawing is based on photocopied / scanned information liable to distortion in scale.
4
AREA CALCULATIONS NB The areas shown are approximate only and have been measured off preliminary drawings as the likely areas at the current state of design using the stated option from the Code of Measuring Practice, 4th edition. RICS / ISVA. These may be affected by future design development and construction tolerances, or the result of surveys for existing buildings. Take account of these factors before planning any financial or property development purpose or strategy and seek confirmation of latest areas before decision making.
5
5
6
Cl. Store 3 2 m2 02.05
Breakout 3 21 m2 02.03
H
JK
7
DESIGN/SKETCH DESIGN Unless stated otherwise, the designs shown are subject to detailed site survey, investigations, and legal definition, the CDM Regulations, and the comments and / or approval of the various relevant Local Authority Officers, Statutory Undertakers, Fire Officers, Engineers and the like. They are copyright, project specific and confidential and no part is to be used or copied in any way without the express prior consent of HLM Architects.
3RD-PARTY INFORMATION NB This drawing includes information provided by independent surveyors and / or consultants, to whom all queries shall be made. HLM Architects can accept no liability for its content or accuracy.
6 Riser 4 m2 02.02
Lift 2 4 m2 00.11
7 8
Unit 2.01 83 m2 02.01
9 10 A
B
C
D
E
8 9
K
F
10
G
M
N
P
Q
R
S
M
N
P
Q
R
S
L
SECOND FLOOR PLAN
G A
B
C
D
E
F
J
1
L 1
3
DN
Stair 2 16 m2 00.16
Riser Shaft
5
Riser Shaft Circulation 8 24 m2 01.19
6
Riser Shaft
10 9 8 7 6 5 4 3 2 1
Riser Shaft
Riser 4 m2 01.15
Riser Shaft
Unit 1.05 89 m2 01.18
H
Breakout 2 85 m2 01.13
JK
7
11
Riser Shaft
Riser Shaft Circulation 7 24 m2 01.27
12 13 14 15 16 17 18 19 20 21 22
Unit 1.11 90 m2 01.25
Unit 1.10 44 m2 01.24
Unit 1.09 45 m2 01.24
Lift 2 4 m2 00.11
Unit 1.02 106 m2 01.06
Male WC 2 Female WC 2 10 m2 9 m2 01.08 01.09
Server Room 15 m2 01.16
Riser Shaft
10 9 8 7 6 5 4 3 2 1
Stair 1 16 m2 00.20
5
Circulation 5 33 m2 01.04
Reception Void 22 m2
Mezzanine 22 m2 01.03
6
Platform Lift 2 m2 00.07
Cl. Store 2 3 m2 Circulation01.11 5 4 m2 00.10
7
Unit 1.04 93 m2 01.17
Riser Shaft
Acc. WC 2 4 m2 Riser 01.07 5 m2 01.12
Riser Shaft
Circulation 6 24 m2 01.26
4 22 x 164 = 3600
12 13 14 15 16 17 18 19 20 21 22
Unit 1.07 84 m2 01.22
3600
Unit 1.06 156 m2 01.20
UP 22 x 164 =
12 13 14 15 16 17 18 19 20 21 22
4
Unit 1.08 105 m2 01.23
UP
11
3
11 DN
UP
22 x 164 = 3600
10 9 8 7 6 5 4 3 2 1
2
H
DN
2
Meeting SS1.1 26 m2 01.01
Meeting SS1.2 47 m2 01.02
Unit 1.01 102 m2 01.05
8
8
Unit 1.03 79 m2 01.14
9 10 A
B
C
D
E
9
K
F
M
10
G
N
P
Q
R
S
P5 DRYLINING TO BRACING AMENDED + SECOND FLOOR LAYOUT AMENDED
29/02/16 RN BC
P4 STAIR 2 UPDATED IN LINE WITH SUBCONTRACTOR + CROSS BRACING ADDED
17/02/16 RN BC
P3 GIFA AMMENDED
27/01/16 RN BC
P2 M + E + BUILDING CONTROL INPUT
27/10/15 RN BC
P1 PRELIMINARY ISSUE FOR COMMENT
08/10/15 RN BC
Rev Description
Date
Drn Chk
Revisions Project
L
BOOLE TECHNOLOGY CENTRE
FIRST FLOOR PLAN Client
University of Lincoln. Lincoln Science + Innovation Park G A