ADD #01 ADDENDUM 1

Report 1 Downloads 188 Views
ADD #01

ADDENDUM 1 DATE:

3/28/17

TO:

All Bidders

PROJECT:

Arcadia Elementary Cooler/Freezer Remodel Granite School District 3461 West 4850 South Taylorsville, UT

ARCHITECT:

ARCHITECT’S PROJECT NO.:

116027

LOGAN 595 S. Riverwoods Parkway Suite 270 Logan, Utah 84321 T 435-753-2850 F 435-753-2851 SALT LAKE CITY 350 West 800 North Suite 121 Salt Lake City, Utah 84103 T 385-242-7348

Cartwright Architects & Engineers

This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents and previous Addenda as noted below. Acknowledge receipt of this Addendum in the space provided in the Bid Form. Failure to acknowledge receipt of this Addendum may be cause for the bid to be disqualified. This Addendum consists of 02 pages and all attachments noted herein.

MODIFICATIONS TO PREVIOUS ADDENDA: 1. NA MODIFICATIONS TO THE PROJECT MANUAL: Note: Changes to the Project Manual are indicated as follows: Deletions are indicated by strikethrough. Additions are indicated by bold italic type. 1. Changes to Bidding Requirements: a. NA 2. Changes to Conditions of the Contract: a. NA 3. Changes to Specifications: a. NA MODIFICATIONS TO THE DRAWINGS: 1. Sheet A101 a. Modified keynote 26AD b. Added keynotes 02HA and 02JA c. Added roll-up door at tray collection opening. d. Added existing mechanical ductwork. Form Version: 9/16

Printed: 28 March 2017 4:07:27 PM

ADDENDUM

Page 1 of 2

ADDENDUM NO. 01 (continued) PROJECT:

Arcadia Elementary Freezer Cooler Addition

ARCHITECT’S PROJECT NO.: 116027

COMMENTS FROM PRE-BID MEETING: Contractor is to bid the project demolition with the understanding that no hazardous materials exist on site. Granite School District will verify material safety prior to construction. Any hazardous materials found by Granite School District will be mitigated by Granite School District. Contractor will not have hazardous material mitigation scope. During site-walk, it was determined that the exhaust fan can be relocated without modification to the existing building framing and structure.

CARTWRIGHT ARCHITECTS & ENGINEERS

Justin M. Campbell

BY: Signature

Name (print)

ATTACHMENTS: A101: Cooler Addition DISTRIBUTION: X

Owner

X

All Bidders

Others:

END OF ADDENDUM NO. 01

Form Version: 9/16

Printed: 28 March 2017 4:07:27 PM

ADDENDUM

Page 2 of 2

3

4

5 SHEET NOTES

1

A. B.

05EB

02JA

02HA C. D. 1

E.

26AB

F.

26AA

G.

09AA EXISTING TILE CMU WALL

H. I.

AIR SPACE PER PLAN DIMENSIONS OR AS REQUIRED TO CLEAR EXISTING OBSTRUCTIONS

26AD

26AC

REFLECTED CEILING PLAN

D2 SCALE:

02BA

02BB 02BE 02CA

02CB

02DA 02DB

02DC

02EA 02FA

1 1/2" MIN.

02FB

MULTI-PURPOSE 28

02AB 02FC

1 1/2" MIN.

EXISTING CONCRETE FLOOR SLAB

02AB

1/4" = 1'-0"

COOLER/ FREEZER WALL PANEL

C

# 02AA

02GA

4" CONCRETE SUB-FLOOR WITH # 3 REBAR @ 16 O.C. BOTH WAYS WITH 1 1/2 CONCRETE COVERAGE

02HA

02FD

1

2x8 PRESSURE TREATED WOOD THERMAL BREAK

4" RIGID SUBGRADE INSULATION

EXISTING SUBGRADE

02AA

KITCHEN 58

02AB

02GA

02DC

02GB 02HA

VAPOR BARRIER

02BA

4" GRAVEL BASE

02CA 02AA

02CB

02BE

02JA 03AA 03AB

COMPACTED SUBGRADE

THERMAL BREAK DETAIL AT WALL B1 SCALE: 3" = 1'-0"

05EA

02AB

02BB

02DA

02DB 05EB 09AA

DEMOLITION FLOOR PLAN

C2 SCALE:

B

1/4" = 1'-0"

11AA

DOOR

11AB 11AC

4" CONCRETE FLOOR

MULTI-PURPOSE 28

11AE

4" RIGID INSULATION

05EA

11AF

APPROX. 6' - 6"

11AC THRESHOLD

2" 02GB

B1

03AA

A101

02HA

KITCHEN 58

11AE 11AB

11AC

EXISTING CONCRETE

VAPOR BARRIER

3"

A1 A101

2' - 0"

4" GRAVEL BASE

A

2' - 0" 22AA

4' - 0"

B1

02FB

1

26AB 26AC

11AG 26AD

05EA 02EA

3

http://www.cartwright-aec.com

CARTWRIGHT PROJECT # DATE:

116027

MARCH 3RD, 2017

DRAWN BY:

JMC

CHECKED BY:

JMC

APPROVED BY:

JMC REVISIONS

# Date 1 3/28/17

Description ADDENDUM 1

11AF

02FD

02FB

02FC

03AB

11AC

02FA

COOLER ADDITION

FLOOR PLAN A4 SCALE: 1/4" = 1'-0"

2

595 S RIVERWOODS PARKWAY SUITE 270 LOGAN UTAH 84321 T435 753.2850 F435 753.2851 ©2017 CARTWRIGHT

11AC

4"

COMPACTED SUBGRADE

1

ARCHITECTS & ENGINEERS

A101

EXISTING SUBGRADE

THERMAL BREAK DETAIL AT FLOOR A1 SCALE: 3" = 1'-0"

APPROX. 16' - 4"

4" RIGID SUBGRADE INSULATION

26AA

A101

11AA 1 1/2" MIN.

4" CONCRETE SUB-FLOOR WITH # 3 REBAR @ 16 O.C. BOTH WAYS WITH 1 1/2" MIN. CONCRETE COVERAGE

22AA

B1 5' - 3"

1 1/2" MIN.

EXISTING QUARRY TILE FLOOR

11AG

11AC

DESCRIPTION REMOVE ALL FLOOR MATERIALS DOWN TO SUBGRADE. REMOVE ENTIRE SHADED AREA. REMOVE STAINLESS STEEL COUNTERS, SUPPORTS, STORAGE SHELVES AND BACKSPLASH. REINSTALL EQUIPMENT PER FLOOR PLAN. CUT AND WELD AT STRATEGIC AREAS AS NECESSARY TO REINSTALL AT NEW LOCATION. DEMOLISH EXISTING (2) SUPPLY LINES BACK TO THE FACE OF WALL. CAP EXISTING SUPPLY LINES AT WALL. EXISTING SUPPLY LINES WITHIN WALL APPROXIMATELY 4'-0" A.F.F. DEMOLISH EXISTING FLOOR SINK TO SANITARY SEWER LINE. DEMOLISH EXISTING DRAINAGE LINES CONNECTION TO SINK BACK TO THE FACE OF WALL. DEMOLISH EXISTING (3) THREE-COMPARTMENT SINK DRAINAGE LINES CONNECTING TO FLOOR SINK. REMOVE, SAFEGUARD AND PROTECT (2) EXISTING FIXTURES. REMOVE, SAFEGUARD AND PROTECT EXISTING THREE-COMPARTMENT SINK AND ASSOCIATED FIXTURES. REMOVE, SAFEGUARD AND PROTECT EXISTING SINK, GARBAGE DISPOSAL, SWITCHES AND ASSOCIATED FIXTURES. EXISTING FIRE EXTINGUISHER TO REMAIN. REINSTALL SAFEGUARDED 4'-0" SECTION OF COUNTER. REUSE EXISTING COUNTER LEGS, BACKSPLASH AND LOWER SHELF. WELD TO OTHER STAINLESS EQUIPMENT. REINSTALL SAFEGUARDED 2'-0" SECTION OF COUNTER. REUSE EXISTING COUNTER LEGS, BACKSPLASH AND LOWER SHELF. WELD TO OTHER STAINLESS EQUIPMENT. REINSTALL SAFEGUARDED THREE-COMPARTMENT SINK AND (2) SAFEGUARDED FIXTURES. PROVIDE NEW PLUMBING LINES TO CONNECT EXISTING FIXTURES TO EXISTING SUPPLY LINES. INDIRECTLY DRAIN THREE COMPARTMENT SINK TO FLOOR SINK PER PLUMBING DRAWINGS. REINSTALL SAFEGUARDED SINK, FIXTURES AND GARBAGE DISPOSAL. REINSTALL EXISTING GARBAGE DISPOSAL SWITCH TO NEW LOCATION. PROVIDE NEW PLUMBING LINES TO CONNECT TO EXISTING SANITARY SEWER. SEE PLUMBING DRAWINGS. REMOVE, SAFEGUARD AND PROTECT METAL SCREEN WALL. REINSTALL SAFEGUARDED METAL SCREEN WALL. LOWER EXISTING ROLL UP DOOR, LOCK AND SECURE FROM INSIDE KITCHEN. KEEP DOOR AND WALL MOUNTED TRACK. REMOVE RECOIL BOX AND EXTRA DOOR SEGEMENTS AS NECESSARY TO CLEAR WALL INTERIOR KITCH WALL FINISH FACE FOR FREEZER WALL INSTALLATION. EXISTING MECHANICAL DUCTWORK LINE. INSULATED AND SEALED CONCRETE FLOOR. CONCRETE FLOOR OVER COMPACTED SUBGRADE. QUARRY TILE OVER CONCRETE. COLOR TO MATCH EXISTING TILE COLOR. CONTINUOUS STAINLESS STEEL SHROUD FROM FLOOR TO CEILING. STEP SHROUD AT THE WALL TILE TO GYPSUM BOARD TRANSITION. FASTEN SHROUD MINIMUM 2'-0" O.C TO TILE GROUT LINES. SEAL ALL HORIZONTAL AND VERTICAL JOINTS WITH CLEAR CAULK. PROVIDE STAINLESS STEEL SHROUD BETWEEN CEILING AND COOLER WALL. REPAIR GYPSUM CEILING TO MATCH EXISTING. REPAINT ENTIRE CEILING. COOLER DOOR. INSTALL DOOR OR WALL MOUNTED DOOR STOP. FREEZER DOOR. COOLER / FREEZER WALL. OFFEST INSTALLATION OF COOLER WALL FROM WALL OBSTRUCTIONS. FIELD VERIFY ALL CLEARANCES AND DIMINSIONS BEFORE FABRICATION OF COOLER WALLS. PROVIDE THRESHOLD OVER THERMAL BREAK JOINT. WALK-IN COOLER AREA. LOCATE COOLER CONDENSOR ON ROOF. PROVIDE CONDENSOR WITH ELECTRICAL DISCONNECT SWITCH. WALK-IN FREEZER AREA. LOCATE COOLER CONDENSOR ON ROOF. PROVIDE CONDENSOR WITH ELECTRICAL DISCONNECT SWITCH. FLOOR SINK (BELOW THREE-COMPARTMENT SINK). SEE PLUMBING DRAWINGS. REMOVE LIGHT AND CAP CONNECTION TO REMAINING LIGHTS AND BALLASTS. RETURN TO OWNER. EXISTING LIGHTS TO REMAIN. RELOCATE 14"X14" EXHAUST OVER THREE-COMPARTMENT SINK. EXHAUST DUCT CONNECTS TO EXISTING MECHANICAL ROOM AND TERMINATES AT EXHAUST FAN. REPAIR GYPSUM CEILING OPENING, MATCH TEXTURE AND FINISH OF EXISTING CEILING. INSTALL 14"X14" EXHAUST VENT OVER THREE-COMPARTMENT SINK. PROVIDE NEW DUCTWORK TO CONNECT TO EXISTING VERTICAL 14"X8" EXHAUST DUCT. ALIGN AND CONNECT EXISTING EQUIPMENT.

CARTWRIGHT

4

5

CONSTRUCTION DOCUMENTS

A101

3/28/2017 4:06:03 PM

D

GYP. CEILING 8' 11"

26AA

26AB

WALL DIMENSIONS ARE TO FACE OF WALL FINISH. FIELD VERIFY ALL EXISTING CONDITIONS AND THEIR COMPATIBILITY WITH NEW CONSTRUCTION PRIOR TO THE COMMENCEMENT OF WORK. COORDINATE DISCREPANCIES WITH ARCHITECT. DO NOT SCALE DRAWINGS. PROTECT AND SAFEGUARD ALL EQUIPMENT OR BUILDING ELEMENTS IN KITCHEN AND SURROUNDING AREAS THAT MAY EXIST, BUT ARE NOT SHOWN ON THE DRAWINGS. NOT ALL KITCHEN ELEMENTS, FIXTURES AND EQUIPMENT ARE SHOWN IN DRAWINGS. ALL EQUIPMENT THAT IS NOT SHOWN ON DRAWINGS IS OUT OF SCOPE OF WORK AND MODIFICATION. PROTECT AND SAFEGUARD ALL BUILDING ELEMENTS AND EQUIPMENT THAT ARE NOT SHOWN. COORDINATE CLEARANCE OF COOLER WALL FROM EXISTING WALL PENETRATIONS BEFORE FABRICATING COOLER WALLS. CONNECT ELECTRICAL TO CHAD PANEL IN BOILER ROOM. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. SEAL ALL GROUT, NEW OR EXISTING DISTURBED DURING CONSTRUCTION. ALL SURFACES, FLOORS OR WALLS, DISTRUBED DURING CONSTRUCTION MUST HAVE A CLEANABLE AND WIPEABLE SURFACE.

KEYNOTES

3461 WEST 4850 SOUTH, TAYLORSVILLE, UT

2

ARCADIA ELEMENTARY COOLER/FREEZER REMODEL

1