SECTION A INDEX
Product Description
Page Number
Form 7 Gray Iron Conduit Bodies . . . . . . . . . . . . . . . . . . . . . .AA1-AA2 Form 7 Covers, Gaskets & Wire Guards . . . . . . . . . . . . . . . . . . . . .AA3 Form 7 Conduit Bodies - Dimensional Data . . . . . . . . . . . . . .AA4-AA6
Spec 5 Malleable Iron Conduit Bodies . . . . . . . . . . . . . . . . . . .AB1-AB2 Spec 5 Conduit Body, Cover & Gasket Assemblies . . . . . . . . . . . . .AB3 Spec 5 Covers, Gaskets & Wire Guards . . . . . . . . . . . . . . . . .AB4-AB5 Spec 5 Conduit Bodies - Dimensional Data . . . . . . . . . . . . . .AB6-AB8 Aluminum Conduit Bodies for Rigid Conduit . . . . . . . . . . . . . .AC1-AC2 Aluminum Conduit Body, Cover & Gasket Assemblies . . . . . . . . . .AC3 Aluminum Conduit Bodies for EMT . . . . . . . . . . . . . . . . . . . . . . . . .AC4 Aluminum Covers, Gaskets & Wire Guards . . . . . . . . . . . . . . . . . .AC5 Aluminum Conduit Bodies - Dimensional Data . . . . . . . . . . . .AC6-AC9 Mogul Conduit Bodies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AD1 Mogul Conduit Bodies - Dimensional Data . . . . . . . . . . . . . . . . . . .AD2
FS/FD Cast Device Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . .AE1-AE2 FS/FD Dry Location Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AE3 FS/FD Wet Location Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AE4 FS/FD Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AE4 OCB Outdoor Connection Box . . . . . . . . . . . . . . . . . . . . . . . . . . . .AE5 FS/FD Cast Device Boxes - Dimensional Data . . . . . . . . . . . . . . . .AE6
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
Notes
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AA1
AA1
Form 7 Conduit Bodies
Form 7 Conduit Bodies For Rigid Conduit & IMC Types LB, T, LL, LR
Trade Size (inches)
Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT). • Flat back design for greater wiring capacity and surface mounting. • Complete interchangeability with other manufacturers’ Form 7 conduit bodies. • Internal volume and maximum wire clearly marked on castings. • Time-saving Clip-on™ covers in steel, gray iron or aluminum. • Easy-Glide™ wire guard for 11⁄4” trade size and larger, see Page - AA3. • For covers and gaskets, see Page - AA3. Material/Finish: • Gray Iron/Zinc Electroplated/Aluminum Enamel • Copper-free Aluminum/Aluminum Enamel Optional Finish: Hot Dip Galvanized. Add suffix “G” to Gray Iron catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gasketed covers. CSA Certified: LR-9795 Suitable for wet locations when used with gasketed covers. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed. Spec: A-A-50563 NEMA: FB-1, FB-2.10
Catalog Number Gray Iron
Catalog Number Aluminum
⁄/™ ‹/¢ 1 1⁄/¢
LB17 LB27 LB37 LB47
LB17-SA LB27-SA LB37-SA LB47-SA
1⁄/™ 2 2⁄/™ 3
LB57 LB67 LB77 LB87
LB57-SA LB67-SA LB77-SA LB87-SA
3⁄/™ 4
LB97 LB107
⁄/™ ‹/¢ 1 1⁄/¢
T17 T27 T37 T47
T17-SA T27-SA T37-SA T47-SA
1⁄/™ 2 2⁄/™ 3
T57 T67 T77 T87
T57-SA T67-SA
3⁄/™ 4
T97 T107
⁄/™ ‹/¢ 1 1⁄/¢
LL17 LL27 LL37 LL47
LL17-SA LL27-SA LL37-SA LL47-SA
1⁄/™ 2 2⁄/™ 3
LL57 LL67 LL77 LL87
LL57-SA LL67-SA
3⁄/™ 4
LL97 LL107
⁄/™ ‹/¢ 1 1⁄/¢
LR17 LR27 LR37 LR47
LR17-SA LR27-SA LR37-SA LR47-SA
1⁄/™ 2 2⁄/™ 3
LR57 LR67 LR77 LR87
LR57-SA LR67-SA
3⁄/™ 4
LR97 LR107
Type LB
Type T
Type LL
Type LR
Dimensional Data: See Pages AA4 - AA6. Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AA2
AA2
Form 7 Conduit Bodies
Form 7 Conduit Bodies For Rigid Conduit & IMC Types TB, TA, X, C, L, E Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT). • Flat back design for greater wiring capacity and surface mounting. • Complete interchangeability with other manufacturers’ Form 7 conduit bodies. • Internal volume and maximum wire clearly marked on castings. • Time-saving Clip-on™ covers in steel, gray iron or aluminum. • Easy-Glide™ wire guard for 11⁄4” trade size and larger, see Page - AA3. • For covers and gaskets, see Page - AA3. Material/Finish: • Gray Iron/Zinc Electroplated/Aluminum Enamel • Copper-free Aluminum/Aluminum Enamel Optional Finish: Hot Dip Galvanized. Add suffix “G” to Gray Iron catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gasketed covers. CSA Certified: LR-9795 Suitable for wet locations when used with gasketed covers. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed. Spec: A-A-50563 NEMA: FB-1, FB-2.10 Dimensional Data: See Pages AA4 - AA6.
Trade Size (inches)
Catalog Number Gray Iron
Catalog Number Aluminum
⁄/™ ‹/¢ 1 1⁄/¢
TB17 TB27 TB37 TB47
TB17-SA TB27-SA TB37-SA TB47-SA
1⁄/™ 2
TB57 TB67
TB57-SA TB67-SA
⁄/™ ‹/¢ 1 1⁄/¢
TA17 TA27 TA37 TA47
1⁄/™ 2
TA57 TA67
⁄/™ ‹/¢ 1 1⁄/¢
X17 X27 X37 X47
1⁄/™ 2
X57 X67
⁄/™ ‹/¢ 1 1⁄/¢
C17 C27 C37 C47
C17-SA C27-SA C37-SA C47-SA
1⁄/™ 2 2⁄/™ 3
C57 C67 C77 C87
C57-SA C67-SA C77-SA C87-SA
⁄/™ ‹/¢ 1 1⁄/¢
L17 L27 L37 L47
1⁄/™ 2
L57 L67
⁄/™ ‹/¢ 1
E17 E27 E37
X17-SA X27-SA X37-SA
Type TB
Type TA
Type X
Type C E17-SA E27-SA E37-SA
Type L (Provided with one blank steel cover)
Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Type E
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AA3 Form 7 Conduit Bodies Covers, Gaskets and Wire Guards
AA3
For Form 7 Conduit Bodies
Type 170
Type 170F
Type 170 Stamped Steel and Aluminum Clip-on™ Cover
Type 170F Cast Gray Iron and Aluminum Clip-on™ Cover Use: To cover conduit body opening.
Use: To cover conduit body opening.
Material/Finish: Stamped Steel/Zinc Pre-Galvanized Stainless Steel Screws Zinc Electroplated Clips Optional Material: Aluminum add suffix -SA as shown below Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gaskets, Type GASK on Form 7 conduit bodies. CSA Certified: LR-9795 Suitable for wet locations when used with gaskets, Type GASK on Form 7 conduit bodies. Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed. Spec: A-A-50563 NEMA: FB-1, FB-2.10
Trade Size (inches)
Optional Finish Hot Dip Galvanized. Add suffix “G” to Gray Iron catalog number. Contact your local representative for pricing and availability.
Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gaskets, Type GASK on Form 7 conduit bodies. CSA Certified: LR-9795 Suitable for wet locations when used with gaskets, Type GASK on Form 7 conduit bodies. Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed. Spec: A-A-50563 NEMA: FB-1, FB-2.10
⁄2 ⁄4 1 11⁄4
170 270 370 470
170-SA 270-SA 370-SA 470-SA
⁄2 ⁄4 1 11⁄4
170F 270F 370F 470F
170F-SA 270F-SA 370F-SA 470F-SA
11⁄2 2 21⁄2-3 31⁄2-4
570 670 870 970
570-SA 670-SA 870-SA 970-SA
11⁄2 2 21⁄2-3 31⁄2-4
570F 670F 870F 970F
570F-SA 670F-SA 870F-SA 970F-SA
3
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Catalog Number
For O-Z/Gedney Form 7 Conduit Bodies 11⁄4-11⁄2-2 EW7-1220S 21⁄2-3-31⁄2-4 EW7-2540S
Optional Material Cast Aluminum add suffix -SA as shown below
Catalog Number Aluminum
1
Use: To ease the job of wire pulling when used with O-Z/Gedney conduit bodies.
Material: Spring Steel
Material/Finish: Gray Iron/Zinc Electroplated Stainless Steel Screws Zinc Electroplated Clips
Catalog Number Steel
(inches)
Type EW Easy-Glide™ Wire Guard
Features: • Reusable • Protects wire insulation • Fits all conduit body hub configurations.
Features: • Centering tabs • Easy installation • Easy removal
Features: • Centering tabs • Easy installation • Easy removal
Trade Size
Type EW
Trade Size (inches) 1 3
Catalog Number Gray Iron
Catalog Number Cast Aluminum
Type GASK
Type GASK Solid Cover Gasket Use: To provide a worry-free, rain tight seal when used with Type 170 or 170F covers that have heavy-duty cover screw washers. Material: Closed-Cell Neoprene. Temperature Rating: 212°F/100°C. Note: UL/CSA not applicable. Trade Size (inches)
Catalog Number
⁄2 ⁄4 1 11⁄4
GASK571 GASK572 GASK573 GASK574
11⁄2 2 21⁄2-3 31⁄2-4
GASK575 GASK576 GASK578 GASK579
1 3
7770 N. Frontage Road Skokie, Illinois 60077
AA4
AA4
Form 7 Conduit Bodies
Form 7 Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Type LB
Type T
Type LL
Type LR
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
a
b
LB17 LB27 LB37 LB47 LB57
⁄2 ⁄4 1 11⁄4 11⁄2
49⁄16 53⁄16 6 61⁄2 71⁄8
LB67 LB77 LB87 LB97 LB107
2 21⁄2 3 31⁄2 4
81⁄8 101⁄2 101⁄2 1211⁄16 1211⁄16
Catalog Number
Trade Size
1 3
c
d
e
Volume Cu. In.
21⁄4 21⁄2 27⁄8 35⁄16 311⁄16
13⁄8 19⁄16 13⁄4 23⁄16 27⁄16
115⁄16 11⁄8 13⁄8 13⁄4 115⁄16
33⁄16 313⁄16 41⁄2 5 57⁄16
4 6.9 10.5 19.3 26.5
41⁄4 51⁄8 57⁄8 69⁄16 71⁄16
3 41⁄4 41⁄4 51⁄4 51⁄4
27⁄16 39⁄16 39⁄16 41⁄2 41⁄2
63⁄8 83⁄8 83⁄8 101⁄4 101⁄4
Max No. Conductors N/A 3 #6AWG 3 #4AWG 3 #3AWG 3 #1AWG
46 102 126 210 238
3 3 3 3 3
#1/0AWG #3/0AWG #3/0AWG #300MCM #300MC
Dimensions in Inches
a
b
c
d
e
Volume Cu. In.
Max No. Conductors
6 19.5 15 20 27
N/A 3 #6AWG 3 #4AWG 3 #3AWG 3 #2AWG
T17 T27 T37 T47 T57
⁄2 ⁄4 1 11⁄4 11⁄2
55⁄8 61⁄4 71⁄4 77⁄16 83⁄16
13⁄4 2 21⁄4 25⁄16 29⁄16
27⁄16 25⁄8 3 33⁄16 39⁄16
15⁄16 1⁄ 13⁄8 13⁄4 115⁄16
33⁄16 313⁄16 41⁄2 5 57⁄16
T67 T77 T87 T97 T107
2 21⁄2 3 31⁄2 4
93⁄16 12 121⁄16 145⁄16 145⁄16
31⁄8 35⁄8 43⁄8 47⁄8 53⁄8
41⁄8 53⁄4 53⁄4 615⁄16 615⁄16
27⁄16 39⁄16 39⁄16 41⁄2 41⁄2
63⁄8 83⁄8 83⁄8 101⁄4 101⁄4
1 3
1
8
50 102 126 210 238
3 3 3 3 3
#2AWG #1/0AWG #1/0AWG #3/0AWG #3/0AWG
Dimensions in Inches
Catalog Number
Trade Size
a
b
c
d
e
LL17 LL27 LL37 LL47 LL57
⁄2 ⁄4 1 11⁄4 11⁄2
49⁄16 53⁄16 6 61⁄2 71⁄8
13⁄8 15⁄8 17⁄8 25⁄16 29⁄16
21⁄4 27⁄16 23⁄4 33⁄16 39⁄16
15
⁄16 11⁄8 13⁄8 13⁄4 115⁄16
33⁄16 313⁄16 41⁄2 5 57⁄16
LL67 LL77 LL87 LL97 LL107
2 21⁄2 3 31⁄2 4
81⁄8 101⁄2 101⁄2 1211⁄16 1211⁄16
31⁄8 35⁄8 43⁄8 47⁄8 53⁄8
41⁄8 53⁄4 53⁄4 615⁄16 615⁄16
27⁄16 39⁄16 39⁄16 41⁄2 41⁄2
63⁄8 83⁄8 83⁄8 101⁄4 101⁄4
1 3
Volume Cu. In.
Max No. Conductors
4 6.9 10.5 19.5 27
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #2AWG
50 102 126 210 238
3 3 3 3 3
#3/0AWG #250MCM #250MCM #350MCM #350MCM
Dimensions in Inches
Catalog Number
Trade Size
LR17 LR27 LR37 LR47 LR57 LR67 LR77 LR87 LR97 LR107
a
b
c
⁄2 ⁄4 1 11⁄4 11⁄2
49⁄16 53⁄16 6 61⁄2 71⁄8
13⁄8 15⁄8 17⁄8 25⁄16 29⁄16
21⁄4 27⁄16 23⁄4 33⁄16 39⁄16
15
⁄16 11⁄8 13⁄8 13⁄4 115⁄16
33⁄16 313⁄16 41⁄2 5 57⁄16
2 21⁄2 3 31⁄2 4
81⁄8 101⁄2 101⁄2 1211⁄16 1211⁄16
31⁄8 35⁄8 43⁄8 47⁄8 53⁄8
41⁄8 53⁄4 53⁄4 615⁄16 615⁄16
27⁄16 39⁄16 39⁄16 41⁄2 41⁄2
63⁄8 83⁄8 83⁄8 101⁄4 101⁄4
1 3
d
e
Volume Cu. In.
Max No. Conductors
4 6.9 10.5 19.5 27
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #2AWG
50 102 126 210 238
3 3 3 3 3
#3/0AWG #250MCM #250MCM #350MCM #350MCM
7770 N. Frontage Road Skokie, Illinois 60077
AA5
AA5
Form 7 Conduit Bodies
Form 7 Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Type TB
Type TA
Type X
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
TB17 TB27 TB37 TB47
e
Volume Cu. In.
Max No. Conductors
15 ⁄16 11⁄8 13⁄8 13⁄4
33⁄16 313⁄16 41⁄2 5
6 9.5 15 20
N/A 3 #6AWG 3 #4AWG 3 #3AWG
115⁄16 27⁄16
57⁄16 63⁄8
27 50
3 #2AWG 3 #2AWG
c
d
e
Volume Cu. In.
Max No. Conductors
25⁄8 27⁄8 31⁄4 35⁄16
27⁄16 25⁄8 3 33⁄16
15⁄16 11⁄8 13⁄8 13⁄4
33⁄16 313⁄16 41⁄2 5
6 9.5 15 20
N/A 3 #6AWG 3 #4AWG 3 #3AWG
311⁄16 41⁄4
39⁄16 41⁄8
115⁄16 27⁄16
57⁄16 63⁄8
27 50
3 #2AWG 3 #2AWG
d
e
Volume Cu. In.
Max No. Conductors
a
b
c
⁄2 ⁄4 1 11⁄4
55⁄8 61⁄4 71⁄4 77⁄16
25⁄8 27⁄8 31⁄4 35⁄16
19⁄16 17⁄8 2 23⁄16
TB57 TB67
11⁄2 2
83⁄16 93⁄16
35⁄8 41⁄4
27⁄16 3
Catalog Number
Trade Size
a
b
TA17 TA27 TA37 TA47
⁄2 ⁄4 1 11⁄4
55⁄8 61⁄4 71⁄4 77⁄16
TA57 TA67
11⁄2 2
83⁄16 93⁄16
Catalog Number
Trade Size
1 3
d
Dimensions in Inches
1 3
Dimensions in Inches
a
b
c
X17 X27 X37 X47
⁄2 ⁄4 1 11⁄4
55⁄8 61⁄4 71⁄4 77⁄16
13⁄4 2 21⁄4 25⁄16
35⁄16 31⁄2 37⁄8 41⁄8
15
⁄16 11⁄8 13⁄8 13⁄4
33⁄16 313⁄16 41⁄2 5
6 9.5 15 20
N/A 3 #6AWG 3 #4AWG 3 #3AWG
X57 X67
11⁄2 2
83⁄16 93⁄16
29⁄16 31⁄8
45⁄8 53⁄16
115⁄16 27⁄16
57⁄16 63⁄8
27 50
3 #2AWG 3 #2AWG
1 3
7770 N. Frontage Road Skokie, Illinois 60077
AA6
AA6
Form 7 Conduit Bodies
Form 7 Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Type C
Type L
Type E
Dimensions in Inches
Catalog Number
a
b
c
d
e
Volume Cu. In.
Max No. Conductors
4 6.9 10.5 20
N/A 3 #6AWG 3 #4AWG 3 #3AWG
C17 C27 C37 C47
⁄2 ⁄4 1 11⁄4
53⁄8 6 7 77⁄16
13⁄8 15⁄8 17⁄8 25⁄16
13⁄8 19⁄16 13⁄4 23⁄16
15
⁄16 11⁄8 13⁄8 13⁄4
33⁄16 313⁄16 41⁄2 5
C57 C67 C77 C87
11⁄2 2 21⁄2 3
83⁄16 93⁄16 12 12
29⁄16 31⁄8 35⁄8 43⁄8
27⁄16 3 41⁄4 41⁄4
115⁄16 27⁄16 39⁄16 39⁄16
57⁄16 63⁄8 83⁄8 83⁄8
27 50 102 126
3 3 3 3
d
e
Volume Cu. In.
Max No. Conductors
1 3
#2AWG #1/0AWG #2/0AWG #2/0AWG
Dimensions in Inches
Catalog Number
Trade Size
a
b
c
L17 L27 L37 L47
⁄2 ⁄4 1 11⁄4
49⁄16 53⁄16 6 61⁄2
13⁄8 13⁄4 2 21⁄2
21⁄4 27⁄16 23⁄4 33⁄16
15
⁄16 11⁄8 13⁄8 13⁄4
33⁄16 313⁄16 41⁄2 5
5 8 13 22
N/A 3 #6AWG 3 #4AWG 3 #2AWG
L57 L67
11⁄2 2
71⁄8 81⁄8
23⁄4 31⁄4
39⁄16 31⁄4
115⁄16 27⁄16
57⁄16 63⁄8
31 54
3 #2AWG 3 #2AWG
d
e
Volume Cu. In.
⁄16 11⁄8 13⁄8
33⁄16 313⁄16 41⁄2
3.9 6.5 10
1 3
Dimensions in Inches
Catalog Number E17 E27 E37
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Trade Size
Trade Size
a
b
c
⁄2 ⁄4 1
49⁄16 53⁄16 6
13⁄8 15⁄8 17⁄8
13⁄8 19⁄16 13⁄4
1 3
15
Max No. Conductors N/A 3 #6AWG 3 #4AWG
7770 N. Frontage Road Skokie, Illinois 60077
AB1
AB1
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Malleable Iron Conduit Bodies For Rigid Conduit & IMC Types LB, T, LB-G & T-G
Trade Size (inches)
Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT). • Raintight when used with gasketed covers. • Malleable iron suitable for use in concrete. • Easy-Glide™ wire guard for 11⁄4” trade size and larger, see Page AB5. • For covers and gaskets, see Pages AB4 and AB5. • Complete interchangeability with other manufacturers’ style “5” or “35” Conduit Bodies. • Internal volume and maximum wire clearly marked on castings. Material/Finish: Malleable Iron/ Zinc Electroplated Aluminum Enamel Optional Finish: Hot Dip Galvanized. Add suffix “G” to standard catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed E-18095 Suitable for wet locations when used with gasketed covers. CSA Certified: LR-9795 Suitable for wet locations when used with gasketed covers. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
Dimensional Data: See Pages AB6 - AB8 Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Catalog Number Malleable Iron Zinc Plated
⁄/™ ‹/¢ 1 1⁄/¢
LB-50 LB-75 LB-100 LB-125
1⁄/™ 2 2⁄/™ 3
LB-150 LB-200 LB-250 LB-300
3⁄/™ 4
LB-350 LB-400
⁄/™ ‹/¢ 1 1⁄/¢
T-50 T-75 T-100 T-125
1⁄/™ 2 2⁄/™ 3
T-150 T-200 T-250 T-300
3⁄/™ 4
T-350 T-400
Trade Size (inches)
Type LB
Type T
Catalog Number Malleable Iron Hot Dip Galvanized
⁄/™ ‹/¢ 1 1⁄/¢
LB-50G LB-75G LB-100G LB-125G
1⁄/™ 2 2⁄/™ 3
LB-150G LB-200G LB-250G LB-300G
3⁄/™ 4
LB-350G LB-400G
⁄/™ ‹/¢ 1 1⁄/¢
T-50G T-75G T-100G T-125G
1⁄/™ 2 2⁄/™ 3
T-150G T-200G T-250G T-300G
3⁄/™ 4
T-350G T-400G
Type LB-G Hot Dip Galvanized
Type T-G Hot Dip Galvanized
7770 N. Frontage Road Skokie, Illinois 60077
AB2
AB2
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Malleable Iron Conduit Bodies For Rigid Conduit & IMC Types LL, LR, TB, X, C
Trade Size (inches)
Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT). • Raintight when used with gasketed covers. • Malleable iron suitable for use in concrete. • Easy-Glide™ wire guard for 11⁄4” trade size and larger, see Page AB5. • For covers and gaskets, see Pages AB4 and AB5. • Complete interchangeability with other manufacturers’ style “5” or “35” Conduit Bodies. • Internal volume and maximum wire clearly marked on castings. Material/Finish: Malleable Iron/ Zinc Electroplated Aluminum Enamel Optional Finish: Hot Dip Galvanized. Add suffix “G” to standard catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed E-18095 Suitable for wet locations when used with gasketed covers. CSA Certified: LR-9795 Suitable for wet locations when used with gasketed covers. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
Dimensional Data: See Pages AB6 - AB8
Catalog Number Malleable Iron Zinc Plated
⁄/™ ‹/¢ 1 1⁄/¢
LL-50 LL-75 LL-100 LL-125
1⁄/™ 2 2⁄/™ 3
LL-150 LL-200 LL-250 LL-300
3⁄/™ 4
LL-350 LL-400
⁄/™ ‹/¢ 1 1⁄/¢
LR-50 LR-75 LR-100 LR-125
1⁄/™ 2 2⁄/™ 3
LR-150 LR-200 LR-250 LR-300
3⁄/™ 4
LR-350 LR-400
⁄/™ ‹/¢ 1 1⁄/¢
TB-50 TB-75 TB-100 TB-125
1⁄/™ 2
TB-150 TB-200
⁄/™ ‹/¢ 1 1⁄/¢
X-50 X-75 X-100 X-125
1⁄/™ 2
X-150 X-200
⁄/™ ‹/¢ 1 1⁄/¢
C-50 C-75 C-100 C-125
1⁄/™ 2 2⁄/™ 3
C-150 C-200 C-250 C-300
3⁄/™ 4
C-350 C-400
Type LL
Type LR
Type TB
Type X
Type C
Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AB3
AB3
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Conduit Body, Cover & Gasket Assemblies For Rigid Conduit & IMC Types LB, LL, LR, C, T Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT) • Packaged complete under one Catalog Number • Ready to use Material/Finish: Conduit body - Malleable Iron Zinc Electroplated with Aluminum Enamel Cover - Type BS Steel Zinc Electroplated Gasket - Type SGN Neoprene Optional Finish: Hot Dip Galvanized. Add suffix “G” to standard catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed: E-18095 Suitable for wet locations CSA Certified: LR-9795 Suitable for wet locations. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
Trade Size (inches)
Catalog Number
⁄/™ ‹/¢ 1 1⁄/¢
LB-50CG LB-75CG LB-100CG LB-125CG
1⁄/™ 2
LB-150CG LB-200CG
⁄/™ ‹/¢ 1 1⁄/¢
T-50CG T-75CG T-100CG T-125CG
1⁄/™ 2
T-150CG T-200CG
⁄/™ ‹/¢ 1 1⁄/¢
LL-50CG LL-75CG LL-100CG LL-125CG
1⁄/™ 2
LL-150CG LL-200CG
⁄/™ ‹/¢ 1 1⁄/¢
LR-50CG LR-75CG LR-100CG LR-125CG
1⁄/™ 2
LR-150CG LR-200CG
⁄/™ ‹/¢ 1 1⁄/¢
C-50CG C-75CG C-100CG C-125CG
1⁄/™ 2
C-150CG C-200CG
Type LB-CG
Type T-CG
Type LL-CG
Type LR-CG
Dimensional Data: See Pages AB6 - AB8. Note: For additional information, please refer to: • Conduit Bodies on pages AB1 and AB2. • Covers and Gaskets on page AB4. • Easy-Glide™ Wire Guards on page AB5.
Type C-CG
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AB4
AB4
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Covers & Gaskets For O-Z/Gedney Malleable Iron Conduit Bodies
Type BS-S
Type BC-G
Type SG & SGN
Type BS-S Domed Top Design Cover
Type SG & SGN Solid Cover Sealing Gasket
Type BC-G Flat Top Design Cover
Use: To cover conduit body opening.
Use: To provide a worry-free, raintight seal when used with Type BS or BC covers.
Use: To cover conduit body opening.
Material/Finish: Stamped Steel Pre-Galvanized Stainless Steel Screws Natural Finish Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gaskets, Type SGN or SG on malleable iron conduit bodies.
Material: Velbuna Composition Closed-Cell Neoprene Temperature Rating: 212°F/100°C Note: UL/CSA not applicable.
Material/Finish: Gray Iron/Hot Dip Galvanized stainless steel screws. Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gaskets, Type SG on malleable iron conduit bodies. CSA Certified: LR-9795 Suitable for wet locations when used with gaskets, Type SG on malleable iron conduit bodies.
CSA Certified: LR-9795 Suitable for wet locations when used with gaskets, Type SGN or SG on malleable iron conduit bodies.
Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10 Trade Size (inches)
Catalog Number
⁄2 ⁄4 1 11⁄4-11⁄2
BS-50S BS-75S BS-100S BS-125S
2 21⁄2-3 31⁄2-4
BS-200S BS-250S BS-350S
1 3
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Trade Size
Catalog Number Velbuna
Catalog Number Neoprene
⁄2 ⁄4 1 11⁄4-11⁄2
SG-50 SG-75 SG-100 SG-125
SGN-50 SGN-75 SGN-100 SGN-125
1
⁄2 ⁄4 1 11⁄4-11⁄2
BC-50G BC-75G BC-100G BC-125G
2 21⁄2-3 31⁄2-4
SG-200 SG-250 SG-350
SGN-200 SGN-250 SGN-350
2 21⁄2-3 31⁄2-4
BC-200G BC-250G BC-350G
(inches) 1 3
Trade Size (inches)
3
Catalog Number
7770 N. Frontage Road Skokie, Illinois 60077
AB5
AB5
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Covers, Gaskets & Wire Guards For O-Z/Gedney Malleable Iron Conduit Bodies
Type BCC
Type SGNC
Type BCC Clip-On™ Cover
Type SGNC Cover Gasket
Use: To cover conduit body opening.
Use: To provide a worry-free, raintight seal when used with Clip-On™ Type BCC cover.
Material/Finish: Gray Iron/Zinc Electroplated Stainless Steel Screws Steel, Zinc-Plated Clips Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gaskets, Type SGNC on malleable iron conduit bodies.
Material: Closed-Cell Neoprene Temperature Rating: 212°F/100°C Note: UL/CSA not applicable.
Catalog Number
Trade Size (inches)
Trade Size (inches)
Catalog Number
BCC-50 BCC-75 BCC-100 BCC-125
1
⁄2 ⁄4 1 11⁄4-11⁄2
SGNC-50 SGNC-75 SGNC-100 SGNC-125
2 21⁄2-3 31⁄2-4
BCC-200 BCC-250 BCC-350
2 21⁄2-3 31⁄2-4
SGNC-200 SGNC-250 SGNC-350
3
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Catalog Number
For O-Z/Gedney Malleable Iron Conduit Bodies 11⁄4-2 EW-1220S 21⁄2-3 EW-2530S 1 3 ⁄2-4 EW-3540S
⁄2 ⁄4 1 11⁄4-11⁄2 1
Use: To ease the job of wire pulling when used with O-Z/Gedney conduit bodies
Material: Spring Steel
Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
(inches)
Type EW Easy-Glide™ Wire Guard
Features: • Reusable • Protects wire insulation • Fits all conduit body hub configurations
CSA Certified: LR-9795 Suitable for wet locations when used with gaskets, Type SGNC on malleable iron conduit bodies.
Trade Size
Type EW
3
7770 N. Frontage Road Skokie, Illinois 60077
AB6
AB6
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Malleable Iron Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Type LB
Type T
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
F
H
J
Volume Cu. In.
Max No. Conductors
LB-50 LB-75 LB-100 LB-125 LB-150
⁄2 ⁄4 1 11⁄4 11⁄2
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 73⁄8
11⁄2 15⁄8 17⁄8 21⁄4 23⁄8
4 45⁄8 53⁄8 7 7
45⁄8 53⁄8 61⁄4 81⁄4 81⁄4
4.0 7.0 12.0 32.0 36.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1/0AWG
LB-200 LB-250 LB-300 LB-350 LB-400
2 21⁄2 3 31⁄2 4
31⁄4 43⁄8 43⁄8 55⁄8 55⁄8
35⁄8 4 43⁄4 51⁄2 55⁄8
95⁄8 123⁄8 123⁄8 15 15
23⁄4 33⁄8 35⁄8 41⁄4 41⁄4
91⁄8 115⁄8 115⁄8 14 14
105⁄8 133⁄4 133⁄4 163⁄4 163⁄4
70.0 142.0 173.0 292.0 324.0
LB-50G LB-75G LB-100G LB-125G LB-150G
⁄2 ⁄4 1 11⁄4 11⁄2
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 73⁄8
11⁄2 11⁄2 17⁄8 21⁄4 23⁄8
4 45⁄8 53⁄8 7 7
43⁄4 45⁄8 61⁄4 81⁄4 83⁄8
4.0 7.0 12.0 32.0 36.0
LB-200G LB-250G LB-300G LB-350G LB-400G
2 21⁄2 3 31⁄2 4
31⁄4 43⁄8 43⁄8 55⁄8 55⁄8
35⁄8 4 43⁄4 51⁄2 55⁄8
95⁄8 123⁄8 123⁄8 15 15
23⁄4 33⁄8 35⁄8 41⁄4 41⁄2
91⁄8 115⁄8 115⁄8 137⁄8 14
105⁄8 133⁄4 133⁄4 163⁄4 163⁄4
70.0 142.0 173.0 292.0 324.0
Catalog Number
Trade Size
A
B
C
T-50 T-75 T-100 T-125 T-150
⁄2 ⁄4 1 11⁄4 11⁄2
53⁄8 61⁄8 71⁄8 91⁄8 91⁄4
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
T-200 T-250 T-300 T-350 T-400
2 21⁄2 3 31⁄2 4
117⁄8 151⁄8 151⁄8 183⁄8 183⁄8
T-50G T-75G T-100G T-125G T-150G
⁄2 ⁄4 1 11⁄4 11⁄2
T-200G T-250G T-300G T-350G T-400G
2 21⁄2 3 31⁄2 4
1 3
1 3
3 3 3 3 3
#4/0AWG #300MCM #400MCM #500MCM #500MCM
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1/0AWG 3 3 3 3 3
#4/0AWG #300MCM #400MCM #500MCM #500MCM
Dimensions in Inches
1 3
1 3
D
G
Volume Cu. In.
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
13⁄8 15⁄8 13⁄4 21⁄4 21⁄4
4.0 7.0 12.0 32.0 36.0
31⁄4 43⁄8 43⁄8 51⁄2 51⁄2
31⁄2 4 43⁄4 51⁄2 51⁄2
95⁄8 123⁄8 123⁄8 15 15
25⁄8 35⁄8 35⁄8 41⁄2 41⁄2
70.0 142.0 173.0 290.0 324.0
53⁄8 61⁄8 71⁄8 91⁄8 91⁄8
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
13⁄8 15⁄8 13⁄4 21⁄4 21⁄4
4.0 7.0 12.0 32.0 36.0
117⁄8 151⁄8 151⁄8 183⁄8 183⁄8
31⁄4 43⁄8 43⁄8 51⁄2 51⁄2
31⁄2 4 43⁄4 51⁄2 51⁄2
95⁄8 123⁄8 123⁄8 15 15
25⁄8 35⁄8 35⁄8 41⁄2 41⁄2
70.0 142.0 173.0 290.0 324.0
Max No. Conductors N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG 3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG 3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
7770 N. Frontage Road Skokie, Illinois 60077
AB7
AB7
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Malleable Iron Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Type LL
Type LR
Type TB
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
G
H
J
Volume Cu. In.
Max No. Conductors
LL-50 LL-75 LL-100 LL-125 LL-150
⁄2 ⁄4 1 11⁄4 11⁄2
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
13⁄8 15⁄8 13⁄4 21⁄4 21⁄4
4 45⁄8 53⁄8 67⁄8 67⁄8
45⁄8 53⁄8 61⁄4 81⁄4 81⁄4
4.0 7.0 12.0 32.0 36.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG
LL-200 LL-250 LL-300 LL-350 LL-400
2 21⁄2 3 31⁄2 4
31⁄4 43⁄8 43⁄8 55⁄8 55⁄8
31⁄2 4 43⁄4 55⁄8 55⁄8
95⁄8 123⁄8 123⁄8 15 15
25⁄8 35⁄8 35⁄8 41⁄2 41⁄2
9 115⁄8 115⁄8 137⁄8 137⁄8
105⁄8 133⁄4 133⁄4 163⁄4 163⁄4
70.0 142.0 173.0 292.0 324.0
1 3
3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
G
H
J
Volume Cu. In.
Max No. Conductors
LR-50 LR-75 LR-100 LR-125 LR-150
⁄2 ⁄4 1 11⁄4 11⁄2
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
13⁄8 15⁄8 13⁄4 21⁄4 21⁄4
4 45⁄8 53⁄8 7 7
45⁄8 53⁄8 61⁄4 81⁄4 81⁄4
4.0 7.0 12.0 32.0 36.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG
LR-200 LR-250 LR-300 LR-350 LR-400
2 21⁄2 3 31⁄2 4
31⁄4 43⁄8 43⁄8 55⁄8 55⁄8
31⁄2 4 43⁄4 55⁄8 55⁄8
95⁄8 123⁄8 123⁄8 15 15
25⁄8 35⁄8 35⁄8 41⁄2 41⁄2
9 115⁄8 115⁄8 137⁄8 137⁄8
105⁄8 133⁄4 133⁄4 163⁄4 163⁄4
70.0 142.0 173.0 292.0 324.0
Catalog Number
Trade Size
A
B
C
D
F
Volume Cu. In.
TB-50 TB-75 TB-100 TB-125
⁄2 ⁄4 1 11⁄4
53⁄8 61⁄4 71⁄8 91⁄8
13⁄8 11⁄2 17⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
11⁄2 11⁄2 17⁄8 21⁄4
4.0 7.0 13.0 32.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG
TB-150 TB-200
11⁄2 2
91⁄4 117⁄8
25⁄8 31⁄8
23⁄4 31⁄2
71⁄4 95⁄8
23⁄8 23⁄4
36.0 70.0
3 #1AWG 3 #2/0AWG
1 3
3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
Dimensions in Inches
1 3
Max No. Conductors
7770 N. Frontage Road Skokie, Illinois 60077
AB8
AB8
Spec 5™ Malleable Iron Conduit Bodies
Spec 5™ Malleable Iron Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Type X
Dimensions in Inches
Catalog Number
Type C
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Trade Size
A
B
C
X-50 X-75 X-100 X-125
⁄2 ⁄4 1 11⁄4
53⁄8 61⁄8 71⁄8 91⁄8
13⁄8 15⁄8 17⁄8 25⁄8
X-150 X-200
11⁄2 2
91⁄4 117⁄8
25⁄8 31⁄8
Catalog Number
Trade Size
A
B
C
D
Volume Cu. In.
C-50 C-75 C-100 C-125 C-150
⁄2 ⁄4 1 11⁄4 11⁄2
53⁄8 61⁄8 71⁄8 91⁄8 91⁄4
13⁄8 15⁄8 17⁄8 25⁄8 25⁄8
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
4.0 7.0 12.0 32.0 36.0
C-200 C-250 C-300 C-350 C-400
2 21⁄2 3 31⁄2 4
117⁄8 151⁄8 151⁄8 183⁄8 183⁄8
31⁄8 43⁄8 43⁄8 51⁄2 51⁄2
31⁄2 4 43⁄4 51⁄2 55⁄8
95⁄8 123⁄8 123⁄8 15 15
70.0 153.0 181.0 290.0 320.0
1 3
D
E
Volume Cu. In.
Max No. Conductors
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
23⁄4 31⁄8 31⁄2 41⁄2
4.0 7.0 12.0 32.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG
27⁄8 31⁄2
71⁄4 91⁄2
45⁄8 51⁄4
36.0 70.0
3 #1AWG 3 #2/0AWG
Dimensions in Inches
1 3
Max No. Conductors N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG 3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
7770 N. Frontage Road Skokie, Illinois 60077
AC1
AC1
Aluminum Conduit Bodies
Aluminum Conduit Bodies For Rigid Conduit & IMC Types LB, T, LL, LR, C Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT). • Raintight when used with gasketed covers. • Easy-Glide™ wire guard for 21⁄2” trade size and larger, see Page AC5. • For covers and gaskets, see Page AC5. • Internal volume and maximum wire clearly marked on castings. Material/Finish: 1 ⁄2” - 2” Trade Size Die-cast Copper-free Aluminum/ Aluminum Enamel 21⁄2” - 4” Trade Size Sand-cast Copper-free Aluminum/ Aluminum Enamel Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gasketed covers. CSA Certified: LR-9795 Suitable for wet locations when used with gasketed covers. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10 Dimensional Data: See Pages AC6, AC7 Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Trade Size (inches)
Catalog Number Die-Cast
⁄/™ ‹/¢ 1 1⁄/¢
LB-50A LB-75A LB-100A LB-125A
1⁄/™ 2 2⁄/™ 3
LB-150A LB-200A
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Type LB-A LB-250A LB-300A
3⁄/™ 4
LB-350A LB-400A
⁄/™ ‹/¢ 1 1⁄/¢
T-50A T-75A T-100A T-125A
1⁄/™ 2 2⁄/™ 3
T-150A T-200A
Type T-A T-250A T-300A
3⁄/™ 4
T-350A T-400A
⁄/™ ‹/¢ 1 1⁄/¢
LL-50A LL-75A LL-100A LL-125A
1⁄/™ 2 2⁄/™ 3
LL-150A LL-200A
Type LL-A LL-250A LL-300A
3⁄/™ 4
LL-350A LL-400A
⁄/™ ‹/¢ 1 1⁄/¢
LR-50A LR-75A LR-100A LR-125A
1⁄/™ 2 2⁄/™ 3
LR-150A LR-200A
Type LR-A LR-250A LR-300A
3⁄/™ 4
LR-350A LR-400A
⁄/™ ‹/¢ 1 1⁄/¢
C-50A C-75A C-100A C-125A
1⁄/™ 2 2⁄/™ 3
C-150A C-200A
3⁄/™ 4
Catalog Number Sand-Cast
Type C-A C-250A C-300A C-350A C-400A
7770 N. Frontage Road Skokie, Illinois 60077
AC2
AC2
Aluminum Conduit Bodies
Aluminum Conduit Bodies For Rigid Conduit & IMC Types TB, X
Trade Size (inches)
Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Tapered threaded hubs (NPT). • Raintight when used with gasketed covers. • Easy-Glide™ wire guard for 11⁄4” trade size and larger, see Page AC5. • For covers and gaskets, see Page AC5. • Internal volume and maximum wire clearly marked on castings. Material/Finish: 1 ⁄2” - 2” Trade Size Sand-cast Copper-free Aluminum/ Aluminum Enamel
Catalog Number Die-Cast
Catalog Number Sand-Cast
⁄/™ ‹/¢ 1 1⁄/¢
TB-50A TB-75A TB-100A TB-125A
1⁄/™ 2
TB-150A TB-200A
⁄/™ ‹/¢ 1 1⁄/¢
X-50A X-75A X-100A X-125A
1⁄/™ 2
X-150A X-200A
Type TB-A
Type X-A
Third Party Certification: UL Listed: E-18095 Suitable for wet locations when used with gasketed covers. CSA Certified: LR-9795 Suitable for wet locations when used with gasketed covers. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10 Dimensional Data: See Page AC6 - AC7. Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AC3
AC3
Aluminum Conduit Bodies
Conduit Body, Cover & Gasket Assemblies For Rigid Conduit & IMC Types LB, T, LL, LR, C
Trade Size (inches)
Catalog Number Die-Cast
Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends.
⁄/™ ‹/¢ 1 1⁄/¢
LB-50ACG LB-75ACG LB-100ACG LB-125ACG
1⁄/™ 2
LB-150ACG LB-200ACG
Features: •Tapered threaded hubs (NPT) • Packaged complete under one Catalog Number • Ready to use
⁄/™ ‹/¢ 1 1⁄/¢
T-50ACG T-75ACG T-100ACG T-125ACG
1⁄/™ 2
T-150ACG T-200ACG
⁄/™ ‹/¢ 1 1⁄/¢
LL-50ACG LL-75ACG LL-100ACG LL-125ACG
1⁄/™ 2
LL-150ACG LL-200ACG
⁄/™ ‹/¢ 1 1⁄/¢
LR-50ACG LR-75ACG LR-100ACG LR-125ACG
1⁄/™ 2
LR-150ACG LR-200ACG
⁄/™ ‹/¢ 1 1⁄/¢
C-50ACG C-75ACG C-100ACG C-125ACG
1⁄/™ 2
C-150ACG C-200ACG
Material/Finish Conduit Body - Die-cast, Copper-free Aluminum with Aluminum Enamel Cover - Type BS Aluminum Gasket - Type SGN Neoprene Third Party Certification: UL Listed: E-18095 Suitable for wet locations. CSA Certified: LR-9795 Suitable for wet locations. Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
Type LB-ACG
Type T-ACG
Type LL-ACG
Dimensional Data: See Pages AC6 - AC7.
Type LR-ACG Note: For additional information, please refer to: • Conduit Bodies on page AC1. • Covers and Gaskets on page AC5.
Type C-ACG
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AC4
AC4
Aluminum Conduit Bodies
Aluminum Conduit Bodies Set Screw Type for EMT (Thinwall Conduit) Types LB, T, LL, LR, C Use: To provide access to conductors for pulling, splicing, maintenance and future changes/ upgrades. Allows connection of straight conduit runs, branch conduit runs and 90° bends. Features: • Slotted hex head steel hardened cup-point set screw for EMT. • Easy-Glide™ Wire Guard for 21⁄2” Trade Size and larger, see Page AC5. • Internal volume and maximum wire clearly marked on castings. • For covers and gaskets, see Page AC5. Material/Finish: 1 ⁄2” - 2” Trade Size Die-cast Copper-free Aluminum/ Aluminum Enamel 21⁄2” - 4” Trade Size Sand-cast Copper-free Aluminum/ Aluminum Enamel Third Party Certification: UL Listed: E-18095 CSA Certified: LR-9795 Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10 Dimensional Data: See Pages AC8 - AC9.
Trade Size (inches)
Catalog Number Die-Cast
⁄/™ ‹/¢ 1 1⁄/¢
LB-50A-TW LB-75A-TW LB-100A-TW LB-125A-TW
1⁄/™ 2 2⁄/™ 3
LB-150A-TW LB-200A-TW
Catalog Number Sand Cast
Type LB-TW LB-250A-TW LB-300A-TW
3⁄/™ 4
LB-350A-TW LB-400A-TW
⁄/™ ‹/¢ 1 1⁄/¢
T-50A-TW T-75A-TW T-100A-TW T-125A-TW
1⁄/™ 2
T-150A-TW T-200A-TW
⁄/™ ‹/¢ 1 1⁄/¢
LL-50A-TW LL-75A-TW LL-100A-TW LL-125A-TW
1⁄/™ 2
LL-150A-TW LL-200A-TW
⁄/™ ‹/¢ 1 1⁄/¢
LR-50A-TW LR-75A-TW LR-100A-TW LR-125A-TW
1⁄/™ 2
LR-150A-TW LR-200A-TW
⁄/™ ‹/¢ 1 1⁄/¢
C-50A-TW C-75A-TW C-100A-TW C-125A-TW
1⁄/™ 2
C-150A-TW C-200A-TW
Type T-TW
Type LL-TW
Type LR-TW
Type C-TW
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AC5
AC5
Aluminum Conduit Bodies
Covers, Gaskets & Wire Guards For O-Z/Gedney Aluminum Conduit Bodies
Type BS-A
Type SG & SGN
Type BS-A Domed Top Design Cover
Type SG & SGN Solid Cover Sealing Gasket
Use: To cover conduit body openings.
Use: To provide a worry-free, raintight seal when used with Type BS-A covers.
Material/Finish: Stamped Copper-free Aluminum Stainless Steel Screws Natural Finish Third Party Certification: UL Listed: E-18095
Material: Velbuna Composition Closed-Cell Neoprene Material: Temperature Rating: 212°F/100°C.
CSA Certified: LR-9795
(inches)
Catalog Number
Trade Size (inches)
Catalog Number Velbuna
Catalog Number Neoprene
1
⁄2 ⁄4 1 11⁄4-11⁄2
SG-50 SG-75 SG-100 SG-125
SGN-50 SGN-75 SGN-100 SGN-125
2 21⁄2-3 31⁄2-4
BS-200A BS-250A BS-350A
2 21⁄2-3 31⁄2-4
SG-200 SG-250 SG-350
SGN-200 SGN-250 SGN-350
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Features: • Reusable • Protects wire insulation • Fits all conduit body hub configurations
(inches)
BS-50A BS-75A BS-100A BS-125A
3
Use: To ease the job of wire pulling when used with O-Z/Gedney conduit bodies
Trade Size
⁄2 ⁄4 1 11⁄4-11⁄2 1
Type EW Easy-Glide™ Wire Guard
Material: Spring Steel
Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10 Trade Size
Type EW
3
Catalog Number
For O-Z/Gedney Sand-Cast Aluminum Conduit Bodies 11⁄4-2 EW-1220S 21⁄2-3 EW-2530S 1 3 ⁄2-4 EW-3540S
7770 N. Frontage Road Skokie, Illinois 60077
AC6
AC6
Aluminum Conduit Bodies
Aluminum Conduit Bodies For Rigid Conduit & IMC Dimensional Data:
Type LB-A
Type T-A
Type LL-A
Type LR-A
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
F
H
J
Volume Cu. In.
Max No. Conductors
LB-50A LB-75A LB-100A LB-125A LB-150A
⁄2 ⁄4 1 11⁄4 11⁄2
11⁄4 11⁄2 13⁄4 21⁄2 21⁄2
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
13⁄8 15⁄8 2 21⁄4 21⁄4
35⁄8 41⁄4 5 61⁄2 61⁄2
41⁄2 51⁄8 61⁄8 77⁄8 77⁄8
4.3 7.3 12.2 34.0 35.8
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1/0AWG
LB-200A LB-250A LB-300A LB-350A LB-400A
2 21⁄2 3 31⁄2 4
31⁄8 43⁄8 43⁄8 55⁄8 55⁄8
33⁄8 4 43⁄4 55⁄8 55⁄8
91⁄2 123⁄8 123⁄8 15 15
25⁄8 33⁄8 33⁄8 41⁄4 41⁄2
81⁄4 115⁄8 115⁄8 137⁄8 14
101⁄8 133⁄8 133⁄8 163⁄4 165⁄8
77.5 142.0 173.0 292.0 324.0
D
G
Volume Cu. In.
1 3
3 3 3 3 3
#4/0AWG #300MCM #400MCM #500MCM #500MCM
Dimensions in Inches
Catalog Number
Trade Size
A
B
C
T-50A T-75A T-100A T-125A T-150A
⁄2 ⁄4 1 11⁄4 11⁄2
5 55⁄8 63⁄4 83⁄8 83⁄8
11⁄4 11⁄2 13⁄4 21⁄2 21⁄2
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 51⁄4 71⁄4 71⁄4
11⁄2 15⁄8 2 21⁄4 21⁄4
4.2 7.1 12.0 31.5 34.5
T-200A T-250A T-300A T-350A T-400A
2 21⁄2 3 31⁄2 4
105⁄8 151⁄8 151⁄4 181⁄4 181⁄8
31⁄8 43⁄8 43⁄8 51⁄2 51⁄2
33⁄8 4 43⁄4 51⁄4 51⁄2
91⁄2 123⁄8 123⁄8 147⁄8 147⁄8
25⁄8 35⁄8 35⁄8 43⁄8 43⁄8
75.0 142.0 182.0 290.0 320.0
1 3
Max No. Conductors N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG 3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
G
H
J
Volume Cu. In.
Max No. Conductors
LL-50A LL-75A LL-100A LL-125A LL-150A
⁄2 ⁄4 1 11⁄4 11⁄2
11⁄4 11⁄2 13⁄4 21⁄2 21⁄2
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
11⁄2 15⁄8 2 21⁄4 21⁄4
35⁄8 41⁄4 5 61⁄2 61⁄2
41⁄2 51⁄8 61⁄8 77⁄8 77⁄8
4.3 7.3 12.2 34.0 35.8
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG
LL-200A LL-250A LL-300A LL-350A LL-400A
2 21⁄2 3 31⁄2 4
31⁄8 43⁄8 43⁄8 55⁄8 55⁄8
33⁄8 37⁄8 43⁄4 51⁄4 55⁄8
91⁄2 123⁄8 123⁄8 15 15
25⁄8 35⁄8 31⁄2 41⁄2 43⁄8
75⁄8 115⁄8 115⁄8 137⁄8 137⁄8
101⁄8 133⁄4 133⁄4 165⁄8 165⁄8
77.5 142.0 173.0 292.0 324.0
Catalog Number
Trade Size
LR-50A LR-75A LR-100A LR-125A LR-150A LR-200A LR-250A LR-300A LR-350A LR-400A
1 3
3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
Dimensions in Inches
B
C
D
G
H
J
Volume Cu. In.
Max No. Conductors
⁄2 ⁄4 1 11⁄4 11⁄2
11⁄4 11⁄2 13⁄4 21⁄2 21⁄2
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
11⁄2 15⁄8 2 21⁄4 21⁄4
35⁄8 41⁄4 5 61⁄2 61⁄2
41⁄2 51⁄8 61⁄8 77⁄8 77⁄8
4.3 7.3 12.2 34.0 35.8
N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG
2 21⁄2 3 31⁄2 4
31⁄8 43⁄8 43⁄8 55⁄8 55⁄8
33⁄8 37⁄8 43⁄4 51⁄4 55⁄8
91⁄2 123⁄8 123⁄8 15 15
25⁄8 35⁄8 31⁄2 41⁄2 41⁄2
75⁄8 115⁄8 115⁄8 137⁄8 137⁄8
101⁄8 133⁄4 133⁄4 165⁄8 165⁄8
77.5 142.0 173.0 292.0 350.0
1 3
3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
7770 N. Frontage Road Skokie, Illinois 60077
AC7
AC7
Aluminum Conduit Bodies
Aluminum Conduit Bodies For Rigid Conduit & IMC
Dimensional Data:
Type C-A
Type TB-A
Type X-A
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
A
B
C
D
Volume Cu. In.
C-50A C-75A C-100A C-125A C-150A
⁄2 ⁄4 1 11⁄4 11⁄2
5 55⁄8 63⁄4 83⁄8 83⁄8
11⁄4 11⁄2 13⁄4 21⁄2 21⁄2
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
4.2 7.1 12.0 31.5 34.5
C-200A C-250A C-300A C-350A C-400A
2 21⁄2 3 31⁄2 4
105⁄8 151⁄8 151⁄8 181⁄4 181⁄8
31⁄8 43⁄8 43⁄8 51⁄2 51⁄2
33⁄8 4 43⁄4 51⁄2 55⁄8
91⁄2 121⁄2 121⁄2 15 15
75.0 153.0 181.0 290.0 320.0
Catalog Number
Trade Size
A
B
C
D
F
Volume Cu. In.
TB-50A TB-75A TB-100A TB-125A
⁄2 ⁄4 1 11⁄4
51⁄4 6 71⁄4 91⁄8
11⁄4 11⁄2 13⁄4 25⁄8
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
13⁄8 11⁄2 17⁄8 21⁄4
4.0 7.0 13.0 32.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG
TB-150A TB-200A
11⁄2 2
91⁄4 117⁄8
25⁄8 31⁄8
23⁄4 31⁄2
71⁄4 95⁄8
23⁄8 23⁄4
34.0 70.0
3 #1AWG 3 #2/0AWG
1 3
Max No. Conductors N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1AWG 3 3 3 3 3
#2/0AWG #4/0AWG #4/0AWG #350MCM #350MCM
Dimensions in Inches
1 3
Max No. Conductors
Dimensions in Inches
Catalog Number
Trade Size
A
B
C
X-50A X-75A X-100A X-125A
⁄2 ⁄4 1 11⁄4
53⁄8 61⁄8 71⁄8 91⁄8
13⁄8 15⁄8 17⁄8 25⁄8
X-150A X-200A
11⁄2 2
91⁄4 117⁄8
25⁄8 31⁄8
1 3
D
E
Volume Cu. In.
Max No. Conductors
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
23⁄4 31⁄8 31⁄2 41⁄2
4.0 7.0 12.0 32.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG
27⁄8 31⁄2
71⁄4 91⁄2
45⁄8 51⁄2
36.0 70.0
3 #1AWG 3 #2/0AWG
7770 N. Frontage Road Skokie, Illinois 60077
AC8
AC8
Aluminum Conduit Bodies
Aluminum Conduit Bodies Set Screw Type for EMT (Thinwall Conduit) Dimensional Data:
Type LB
Type T
Type LL
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
F
H
J
Volume Cu. In.
Max No. Conductors N/A 3 #6AWG 3 #4AWG 3 #2AWG 3 #1/0AWG
LB-50A-TW LB-75A-TW LB-100A-TW LB-125A-TW LB-150A-TW
⁄2 ⁄4 1 11⁄4 11⁄2
11⁄4 11⁄2 13⁄4 21⁄2 21⁄2
13⁄8 15⁄8 2 25⁄8 23⁄4
4 45⁄8 53⁄8 71⁄4 71⁄4
13⁄8 15⁄8 2 21⁄4 21⁄4
35⁄8 41⁄4 5 61⁄2 61⁄2
41⁄2 51⁄8 61⁄8 77⁄8 77⁄8
4.3 7.3 12.2 34.0 35.8
LB-200A-TW LB-250A-TW LB-300A-TW LB-350A-TW LB-400A-TW
2 21⁄2 3 31⁄2 4
31⁄8 43⁄8 43⁄8 55⁄8 55⁄8
33⁄8 4 43⁄4 55⁄8 55⁄8
91⁄2 123⁄8 123⁄8 15 15
25⁄8 33⁄8 33⁄8 41⁄4 41⁄2
81⁄4 115⁄8 115⁄8 137⁄8 14
101⁄8 133⁄8 133⁄8 163⁄4 165⁄8
77.5 142.0 173.0 292.0 324.0
1 3
3 3 3 3 3
#4/0AWG #300MCM #300MCM #500MCM #500MCM
Dimensions in Inches
Catalog Number
Trade Size
A
B
C
D
G
Volume Cu. In.
Max No. Conductors
T-50A-TW T-75A-TW T-100A-TW T-125A-TW
⁄2 ⁄4 1 11⁄4
5 55⁄8 63⁄4 83⁄8
11⁄4 11⁄2 13⁄4 21⁄2
13⁄8 15⁄8 2 25⁄8
4 45⁄8 51⁄4 71⁄4
11⁄2 15⁄8 2 21⁄4
4.2 7.1 12.0 31.5
N/A 3 #6AWG 3 #4AWG 3 #2AWG
T-150A-TW T-200A-TW
11⁄2 2
83⁄8 105⁄8
21⁄2 31⁄8
23⁄4 33⁄8
71⁄4 91⁄2
21⁄4 25⁄8
34.5 75.0
3 #1AWG 3 #2/0AWG
1 3
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
G
H
J
Volume Cu. In.
Max No. Conductors
LL-50A-TW LL-75A-TW LL-100A-TW LL-125A-TW
⁄2 ⁄4 1 11⁄4
11⁄4 11⁄2 13⁄4 21⁄2
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
11/2 15⁄8 2 21⁄4
35⁄8 41⁄4 5 61⁄2
41⁄2 51⁄8 61⁄8 77⁄8
4.3 7.3 12.2 34.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG
LL-150A-TW LL-200A-TW
11⁄2 2
21⁄2 31⁄8
23⁄4 33⁄8
71⁄4 91⁄2
21⁄4 25⁄8
61⁄2 75⁄8
77⁄8 101⁄8
35.8 77.5
3 #1AWG 3 #2/0AWG
1 3
7770 N. Frontage Road Skokie, Illinois 60077
AC9
AC9
Aluminum Conduit Bodies
Aluminum Conduit Bodies Set Screw Type for EMT (Thinwall Conduit)
Dimensional Data: Type LR
Type C
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Dimensions in Inches
Catalog Number
Trade Size
B
C
D
G
H
J
Volume Cu. In.
Max No. Conductors
LR-50A-TW LR-75A-TW LR-100A-TW LR-125A-TW
⁄2 ⁄4 1 11⁄4
11⁄4 11⁄2 13⁄4 21⁄2
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
11/2 15⁄8 2 21⁄4
35⁄8 41⁄4 5 61⁄2
41⁄2 51⁄8 61⁄8 77⁄8
4.3 7.3 12.2 34.0
N/A 3 #6AWG 3 #4AWG 3 #2AWG
LR-150A-TW LR-200A-TW
11⁄2 2
21⁄2 31⁄8
23⁄4 33⁄8
71⁄4 91⁄2
21⁄4 25⁄8
61⁄2 75⁄8
77⁄8 101⁄8
35.8 77.5
3 #1AWG 3 #2/0AWG
1 3
Dimensions in Inches
Catalog Number
Trade Size
A
B
C
D
Volume Cu. In.
Max No. Conductors
C-50A-TW C-75A-TW C-100A-TW C-125A-TW
⁄2 ⁄4 1 11⁄4
5 55⁄8 63⁄4 83⁄8
11⁄4 11⁄2 13⁄4 21⁄2
13⁄8 15⁄8 2 25⁄8
4 45⁄8 53⁄8 71⁄4
4.2 7.1 12.0 31.5
N/A 3 #6AWG 3 #4AWG 3 #2AWG
C-150A-TW C-200A-TW
11⁄2 2
83⁄8 105⁄8
21⁄2 31⁄8
23⁄4 33⁄8
71⁄4 91⁄2
34.5 75.0
3 #1/0AWG 3 #3/0AWG
1 3
7770 N. Frontage Road Skokie, Illinois 60077
AC10
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Notes
AC10
7770 N. Frontage Road Skokie, Illinois 60077
AD1
AD1
Mogul Conduit Bodies
Mogul Conduit Bodies For Rigid Conduit & IMC Types C8X, T8X, LB6X, UB6X
(inches)
Catalog Number Cast Iron
Catalog Number Aluminum
1 1⁄/¢ 1⁄/™ 2
C8X-100G C8X-125G C8X-150G C8X-200G
C8X-100A C8X-125A C8X-150A C8X-200A
2⁄/™ 3 3⁄/™ 4
C8X-250G C8X-300G C8X-350G C8X-400G
C8X-250A C8X-300A C8X-350A C8X-400A
1 1⁄/¢ 1⁄/™ 2
T8X-100G T8X-125G T8X-150G T8X-200G
T8X-100A T8X-125A T8X-150A T8X-200A
2⁄/™ 3 3⁄/™ 4
T8X-250G T8X-300G T8X-350G T8X-400G
T8X-250A T8X-300A T8X-350A T8X-400A
1 1⁄/¢ 1⁄/™ 2
LB6X-100G LB6X-125G LB6X-150G LB6X-200G
LB6X-100A LB6X-125A LB6X-150A LB6X-200A
Third Party Certification: UL Listed: E-18095 Raintight-Suitable for wet locations.
2⁄/™ 3 3⁄/™ 4
LB6X-250G LB6X-300G LB6X-350G LB6X-400G
LB6X-250A LB6X-300A LB6X-350A LB6X-400A
CSA Certified: LR-9795 Raintight-Suitable for wet locations.
1 1⁄/¢ 1⁄/™ 2
UB6X-100G UB6X-125G UB6X-150G UB6X-200G
UB6X-100A UB6X-125A UB6X-150A UB6X-200A
2⁄/™ 3 3⁄/™ 4
UB6X-250G UB6X-300G UB6X-350G UB6X-400G
UB6X-250A UB6X-300A UB6X-350A UB6X-400A
Use: To provide adequate access and wiring area for pulling large and heavy conductors. Features: • Type C8X meets NEC and CEC 8 to 1 ratio. • Type T8X meets NEC and CEC 8 to 1 ratio on C pulls only. • Types LB6X and UB6X meet NEC and CEC 6 to 1 ratio. • Supplied with cover and attached gasket. • Smooth integral hub bushings prevent wire pulling damage. • Raintight-suitable for use in wet locations. Material/Finish: Cast Iron/Hot Dipped Galvanized Copper-free Aluminum/Aluminum Paint Stainless Steel Screws Closed-Cell Neoprene Gasket
Applicable Third Party Standards: UL Standard: 514A, 514B CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, FB-2.10
Trade Size
Type C8X
Type T8X
Type LB6X
Dimensional Data: See Page AD2
Type UB6X
Note: Conduit bodies are suitable for use in Class I, Div. 2 hazardous locations per NEC Section 501.4(B).
Type EW Easy-Glide™ Wire Guard Use: To ease the job of wire pulling when used with O-Z/Gedney conduit bodies. Features: • Reusable. • Protects wire insulation. • Fits all conduit body hub configurations. Material: Spring Steel
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Trade Size (inches)
Catalog Number
For O-Z/Gedney Mogul Conduit Bodies 1-2 21⁄2-3 31⁄2-4
EW-1220S EW-2530S EW-3540S
Type EW
7770 N. Frontage Road Skokie, Illinois 60077
AD2
AD2
Mogul Conduit Bodies
Mogul Conduit Bodies For Rigid Conduit & IMC Dimensional Data: Dimensions in Inches
Type C8XG & Type C8XA Catalog Number
Trade Size
Length
C8X-100 C8X-125 C8X-150 C8X-200
1 11⁄4 11⁄2 2
12 121⁄16 181⁄8 181⁄16
3 35⁄16 37⁄8 47⁄16
25⁄8 25⁄8 33⁄16 33⁄16
10 10 16 16
C8X-250 C8X-300 C8X-350 C8X-400
21⁄2 3 31⁄2 4
271⁄8 271⁄4 353⁄8 357⁄16
53⁄16 515⁄16 73⁄16 79⁄16
411⁄16 411⁄16 511⁄16 511⁄16
24 24 32 32
8X Length
Dimensions in Inches
Type T8XG & Type T8XA Catalog Number
Trade Size
Length
T8X-100 T8X-125 T8X-150 T8X-200
1 11⁄4 11⁄2 2
12 121⁄16 181⁄8 181⁄16
3 35⁄16 37⁄8 47⁄16
2 ⁄8 25⁄8 33⁄16 33⁄16
10 10 16 16
T8X-250 T8X-300 T8X-350 T8X-400
21⁄2 3 31⁄2 4
271⁄8 271⁄4 353⁄8 357⁄16
53⁄16 515⁄16 73⁄16 79⁄16
411⁄16 411⁄16 511⁄16 511⁄16
24 24 32 32
Assembled Height Width
8X Length
5
Dimensions in Inches
Type LB6XG & Type LB6XA Catalog Number
Trade Size
Length
LB6X-100 LB6X-125 LB6X-150 LB6X-200
1 11⁄4 11⁄2 2
95⁄8 95⁄8 147⁄16 147⁄16
35⁄8 35⁄8 55⁄8 55⁄8
21⁄2 21⁄2 3 3
71⁄2 71⁄2 12 12
LB6X-250 LB6X-300 LB6X-350 LB6X-400
21⁄2 3 31⁄2 4
22 22 281⁄2 281⁄2
71⁄2 71⁄2 91⁄4 91⁄4
41⁄2 41⁄2 51⁄2 51⁄2
18 18 24 24
Assembled Height Width
6X Length
Dimensions in Inches
Type UB6XG & Type UB6XA Catalog Number
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Assembled Height Width
Trade Size
Length
UB6X-100 UB6X-125 UB6X-150 UB6X-200
1 11⁄4 11⁄2 2
10 ⁄16 107⁄16 159⁄16 159⁄16
3 ⁄8 43⁄16 51⁄8 53⁄4
2 ⁄8 25⁄8 33⁄16 33⁄16
71⁄2 71⁄2 12 12
UB6X-250 UB6X-300 UB6X-350 UB6X-400
21⁄2 3 31⁄2 4
231⁄16 235⁄16 30 30
81⁄2 81⁄2 103⁄8 103⁄8
411⁄16 411⁄16 511⁄16 511⁄16
18 18 24 24
7
Assembled Height Width 7
6X Length
5
7770 N. Frontage Road Skokie, Illinois 60077
AE1
Cast Device Boxes
AE1
Cast Device Boxes For Rigid Conduit & IMC Types FS - Shallow FD - Deep Use: Accommodates wiring devices and provides opening to splice, tap or pull conductors. Features: • Tapered threaded hubs (NPT) with integral bushings. • Both FS and FD styles are deeper than similar boxes, providing greater internal volume. • Internal grounding screw standard on all boxes. • Mounting feet standard on FS, FD, FSC, FDC, FSA and FDA styles. FS/FD boxes without mounting lugs may be supported by the attached conduits per NEC Section 314-23(E). • Available single gang, two gang and tandem styles. • Suitable for use in wet locations when used with gasketed covers. • Gray Iron is suitable for concrete use. • For use with FS style covers on Pages AE3 and AE4 as well as standard device plates made of steel, brass, bakelite, etc. Material/Finish: Gray Iron/Zinc Electroplated/Aluminum Enamel. Copper-free Aluminum/Aluminum Enamel.
Trade Size
Catalog Number Gray Iron
Catalog Number Aluminum
⁄/™ ‹/¢ 1
FS-1-50 FS-1-75 FS-1-100
FS-1-50A FS-1-75A
⁄/™ ‹/¢ 1
FD-1-50 FD-1-75 FD-1-100
FD-1-50A FD-1-75A
⁄/™ ‹/¢ 1
FSC-1-50 FSC-1-75 FSC-1-100
FSC-1-50A FSC-1-75A
⁄/™ ‹/¢ 1
FDC-1-50 FDC-1-75 FDC-1-100
FDC-1-50A FDC-1-75A
⁄/™ ‹/¢
FSL-1-50 FSL-1-75
⁄/™ ‹/¢
FDL-1-50 FDL-1-75
⁄/™ ‹/¢
FSR-1-50 FSR-1-75
⁄/™ ‹/¢
FDR-1-50 FDR-1-75
⁄/™ ‹/¢
FSS-1-50 FSS-1-75
⁄/™ ‹/¢
FSA-1-50 FSA-1-75
⁄/™ ‹/¢
FDA-1-50 FDA-1-75
(inches)
Type FSC & FDC Single Gang with mounting feet
FSS-1-75A
Optional Finish: Hot Dip Galvanized. Add suffix “G” to Gray Iron catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed: E-18095 Raintight-Suitable for wet locations when used with gasketed covers. See pages AE3 and AE4. CSA Certified: LR-9795 Raintight-Suitable for wet locations when used with gasketed covers. See pages AE3 and AE4. Dimensional Data: See page AE6.
Type FS & FD Single Gang with mounting feet
Type FSL & FDL Single Gang
Type FSR & FDR Single Gang Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1 Suggested Specifications: Where cast device boxes are required for mounting wiring devices or splicing, taps or pulling conductors, they are zinc electroplated gray iron with aluminum enamel or copper-free aluminum. They are UL Listed and CSA Certified for wet locations when used with gasketed covers.
Type FSS Single Gang
Type FSA & FDA Single Gang with mounting feet Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AE2
Cast Device Boxes
AE2
Cast Device Boxes For Rigid Conduit & IMC Types FS - Shallow FD - Deep Use: Accommodates wiring devices and provides opening to splice, tap or pull conductors. Features: • Tapered threaded hubs (NPT) with integral bushings. • Both FS and FD styles are deeper than similar boxes, providing greater internal volume. • Internal grounding screw standard on all boxes. • Mounting feet standard on FS, FD, FSC, FDC, FSA and FDA styles. FS/FD boxes without mounting lugs may be supported by the attached conduits per NEC Section 314-23(E). • Available single gang, two gang and tandem styles. • Suitable for use in wet locations when used with gasketed covers. • Gray Iron is suitable for concrete use. • For use with FS style covers on Pages AE3 and AE4 as well as standard device plates made of steel, brass, bakelite, etc. Material/Finish: Gray Iron/Zinc Electroplated/Aluminum Enamel. Copper-free Aluminum/Aluminum Enamel.
Trade Size (inches)
Catalog Number Gray Iron
⁄/™ ‹/¢
FSCC-1-50 FSCC-1-75
⁄/™ ‹/¢
FDCC-1-50 FDCC-1-75
⁄/™ ‹/¢ 1
FSCT-1-50 FSCT-1-75 FSCT-1-100
⁄/™ ‹/¢ 1
FDCT-1-50 FDCT-1-75 FDCT-1-100
⁄/™ ‹/¢
FSX-1-50 FSX-1-75
⁄/™ ‹/¢
FDX-1-50 FDX-1-75
⁄/™ ‹/¢ 1
FS-2-50 FS-2-75 FS-2-100
⁄/™ ‹/¢ 1
FD-2-50 FD-2-75 FD-2-100
⁄/™ ‹/¢ 1
FSC-2-50 FSC-2-75 FSC-2-100
⁄/™ ‹/¢ 1
FDC-2-50 FDC-2-75 FDC-2-100
‹/¢
FS-2T-75
Catalog Number Aluminum FSCC-1-75A
Type FSCC & FDCC Single Gang
Type FSCT & FDCT Single Gang
FS-2-75A
Type FSX & FDX Single Gang FSC-2-75A
Optional Finish: Hot Dip Galvanized. Add suffix “G” to Gray Iron catalog number. Contact your local representative for pricing and availability. Third Party Certification: UL Listed: E-18095 Raintight-Suitable for wet locations when used with gasketed covers. See pages AE3 and AE4. CSA Certified: LR-9795 Raintight-Suitable for wet locations when used with gasketed covers. See pages AE3 and AE4. Dimensional Data: See page AE6.
Type FS-2 & FD-2 Two Gang with mounting feet
Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1 Suggested Specifications: Where cast device boxes are required for mounting wiring devices or splicing, taps or pulling conductors, they are zinc electroplated gray iron with aluminum enamel or copper-free aluminum. They are UL Listed and CSA Certified for wet locations when used with gasketed covers.
Type FSC-2 & FDC-2 Two Gang with mounting feet
Type FS-2T Tandem with mounting feet Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AE3
AE3
Cast Device Boxes
Cast Device Box Covers For FS & FD Boxes Types FS-1, FS-2
Suitable for Wet Locations When Installed With Sealing Gaskets.
Use: To cover and seal FS and FD style boxes and to mount wiring devices. Features: • Various styles and sizes to meet most applications. • Stainless Steel screws to prevent corrosion (on blank gray iron covers only). • Blank covers are weatherproof when used with sealing gaskets (ordered separately). See page AE4. • Covers also mount on ordinary boxes with standard device box openings. Material/Finish: Gray Iron/Zinc-Electroplated Steel/Zinc-Electroplated Aluminum/Aluminum Enamel Third Party Certification: UL Listed: E-18095
Blank Steel FS-1-BCS
Blank Steel FS-2-BCS
Blank Gray Iron FS-1-BC
Cast Aluminum FS-1-BCA
Gray Iron FS-2-BC
Blank Cast Aluminum FS-2-BCA
Suitable for Dry Locations Only.
CSA Certified: LR-9795 Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1, OS-1
Toggle Switch Steel FS-1-SCS
Toggle Switch Steel FS-2-SCS
Catalog Number Single Gang FS-1-BCS FS-1-BC FS-1-BCA FS-1-SCS FS-1-DCS FS-1-DC FS-1-DCA FS-1-LRCS FS-1-SRCS
Duplex Receptacle Steel Gray Iron Cast Alum. FS-1-DCS FS-1-DC FS-1-DCA
Duplex Receptacle Steel FS-2-DCS
Two Gang FS-2-BCS FS-2-BC FS-2-BCA FS-2-SCS FS-2-DCS FS-2-SDCS
Round Receptacle 113⁄32 dia.. Steel 15⁄8 dia.. Steel FS-1-LRCS FS-1-SRCS
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Toggle Switch & Duplex Receptacle Steel FS-2-SDCS
7770 N. Frontage Road Skokie, Illinois 60077
AE4
AE4
Cast Device Boxes
Cast Device Box Covers & Gaskets Suitable for Wet Locations Types FS-1, FS-2 Use: To cover and seal FS and FD style boxes and to mount wiring devices. Features: • Various styles and sizes to meet most applications. • Stainless steel screws to prevent corrosion. • All wet location covers supplied with sealing gaskets. • Covers also mount on ordinary boxes with standard device box openings.
Duplex Receptacle Die-Cast Aluminum FS-1-WDCA
Locking Toggle Switch Sand-cast Aluminum FS-2-WSCA
Material/Finish: Aluminum/Aluminum Enamel Neoprene Gaskets Third Party Certification: UL Listed: E-18095 CSA Certified: LR-9795 Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18 Fed Spec: A-A-50563 NEMA: FB-1 Catalog Number Single Gang FS-1-WDCA FS-1-WRCA FS-1-GFCA FS-1-SG FS-2-WSCA FS-1-WPCA
Ground Fault Receptacle Aluminum FS-1-GFCA
Locking Toggle Switch Sand-cast Aluminum FS-1-WSCA
Electrical Rating 15 Amp - 125 Volts 15 Amp - 250 Volts 20 Amp - 125 Volts
113⁄32" Diameter
Round Receptacle Die-cast Aluminum FS-1-WRCA
Pull Switch Sand-cast Aluminum FS-1-WPCA
Two Gang FS-2-WSCA FS-2-SG
Sealing Gasket Neoprene FS-1-SG
Effective February, 2002 Copyright 2002 Printed in U.S.A.
Sealing Gasket Neoprene FS-2-SG
7770 N. Frontage Road Skokie, Illinois 60077
AE5
AE5
Cast Device Boxes
Outdoor Connection Box Type OCB Use: Provides a simple method of installing receptacles used for head-bolt heater outlets in cold area, recreational vehicles, parking areas, trucking terminals, etc. Replaces makeshift enclosures and is an easy way to install outdoor wiring devices. Features: • Easy installation. • Standard set-screw design provides easy slip-fit mounting on either unthreaded or threaded 4” trade size rigid or IMC conduit. • Set screws allow permanent positioning of receptacle openings as required. • Use with standard receptacles and covers. • Has four standard FS openings which accommodate single, duplex and GFI receptacles and weatherproof covers. • Corrosion resistant construction. • Compact profile. • Large volume for wiring capacity to allow feed-thru and splices.
Typical Application
Type OCB
Dimensional Data: Dimensions in Inches
Catalog Number
OCB404-SA
Hub Size with 3 Set Screws
Wiring Capacity (cu. inches)
Number Duplex Receptacle Openings
A
B
4
99
4
69⁄16
47⁄8
Material/Finish: Copper-free Aluminum/Aluminum Enamel Third Party Certification: UL Listed: E-18095 CSA Certified: LR-9795 Applicable Third Party Standards: UL Standard: 514A CSA Standard: C22.2 No. 18
Effective February, 2002 Copyright 2002 Printed in U.S.A.
7770 N. Frontage Road Skokie, Illinois 60077
AE6
AE6
Cast Device Boxes
Cast Device Boxes For Rigid Conduit & IMC
Dimensional Data:
Type FS & FD
Dimensions in Inches
Catalog Number All FS Type Boxes All FD Type Boxes
Trade Size
A
B
C
D
E
F
3
⁄8 ⁄4 7 ⁄8
411⁄16 49⁄16 -
315⁄16 313⁄16 -
⁄8 ⁄4 7 ⁄8
411⁄16 49⁄16 -
315⁄16 315⁄16 -
1
⁄2 ⁄4 1
3
⁄4 ⁄4 7 ⁄8
3
23⁄8 23⁄8 23⁄8
23⁄16 23⁄16 23⁄16
5
3
1
⁄2 ⁄4 1
3
⁄4 ⁄4 7 ⁄8
3
31⁄16 31⁄16 31⁄16
27⁄8 27⁄8 27⁄8
5
3
Effective February, 2002 Copyright 2002 Printed in U.S.A.
3
Internal Volume (cu. inches) Single Gang FS 21.0 FD 28.0 Double Gang FS 33.2 FD 46.0 Tandem 44.0
7770 N. Frontage Road Skokie, Illinois 60077