APOLLO napoli sealed electric straight multirail technical specification
30 45-60
30
450/500/600
500
45-60
15
Dt
15
Dt
146
800
700
166
Db
15
40
40
front view
Db
A
15 40
side view
40
front view
A top view side view
top view
NAPOLI STRAIGHT DIMENSIONS (mm) Height of radiator 700, 800 Width of radiator Upright tube dimensions
450
500
600
30 x 40
30 x 40
30 x 40
Cross tube diameter Wall to front of rad
(A)
Wall to pipe centres
22
22
22
85 - 100
85 - 100
85 - 100
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Side entry Bottom entry
Distance between tappings
Side entry
Pipe centres
Side entry
Bottom entry Bottom entry Bracket position
(B) (C)
N/A
N/A
N/A
N/A
N/A
N/A
(C)
N/A
N/A
N/A
Top
(Dt)
90
90
90
Bottom
(Db)
90
90
90 TEMPERATURE
NAPOLI STRAIGHT 700 HIGH WEIGHTS AND VOLUMES Model width mm
450
500
600
FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)
Dry weight (A) Kg
5.50
5.90
6.60
Water content (B) Litres
3.10
3.30
3.80
Working weight (A+B) Kg
8.60
9.20
10.40
5 °C
0.050
ΔT=50k Chrome outputs: Watts ΔT=50k
200
200
200
10 °C
0.123
10 °F
0.057
200
200
200
15 °C
0.209
20 °F
0.142
20 °C
0.304
30 °F
0.240
25 °C
0.406
40 °F
0.348
White outputs: Watts
NAPOLI STRAIGHT 800 HIGH WEIGHTS AND VOLUMES Model height mm
500
30 °C
0.515
50 °F
0.466
Dry weight (A) Kg
6.60
35 °C
0.629
60 °F
0.590
Water content (B) Litres
3.80
40 °C
0.748
70 °F
0.721
10.40
45 °C
0.872
80 °F
0.858
N/A
50 °C
1.000
90 °F
1.000
200
55 °C
1.132
100 °F
1.147
60 °C
1.267
110 °F
1.298
65 °C
1.406
120 °F
1.454
70 °C
1.549
130 °F
1.613
Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
ADDITIONAL INFORMATION Material
Mild steel
Steel tube measurements Steel thickness
See dimensions table Upright Cross tubes
Maximum working pressure
1.5mm 1.2mm 2 bar/200 kPa
Testing pressure
12 bar/1200 kPa
Maximum working temperature
70°C
Configuration
700 high
2 banks/14 tubes (4 + 10)
800 high
2 banks/16 tubes (4 + 12)
75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT
APOLLO napoli sealed electric straight multirail technical specification 30
30
500
45-60
300/450/500/600
45-60
15
Dt
15
Dt
132
1200
1100
122
132
122
Db
15 front view
40
Db
40
40
A
front view
side view
15 40
A top view
side view top view
NAPOLI STRAIGHT DIMENSIONS (mm) Height of radiator 1100, 1200 Width of radiator Upright tube dimensions
300
450
500
600
30 x 40
30 x 40
30 x 40
30 x 40
Cross tube diameter Wall to front of rad
(A)
Wall to pipe centres
22
22
22
22
85 - 100
85 - 100
85 - 100
85 - 100
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Side entry Bottom entry
(B)
Distance between tappings
Side entry
Pipe centres
Side entry Bottom entry
Bracket position
Top Bottom
(Db)
Bottom entry
(C)
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
(C)
N/A
N/A
N/A
N/A
(Dt)
90
90
90
90
90
90
90
90
TEMPERATURE
NAPOLI STRAIGHT 1100 HIGH WEIGHTS AND VOLUMES Model height mm
300
450
500
600
Dry weight (A) Kg
6.30
8.30
8.90
10.00
FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)
Water content (B) Litres
3.80
4.80
5.20
5.90
Working weight (A+B) Kg
10.10
13.10
14.10
15.90
5 °C
0.050
N/A
300
300
300
10 °C
0.123
10 °F
0.057
200
200
300
300
15 °C
0.209
20 °F
0.142
20 °C
0.304
30 °F
0.240
25 °C
0.406
40 °F
0.348
ΔT=50k Chrome outputs: Watts ΔT=50k White outputs: Watts
NAPOLI STRAIGHT 1200 HIGH WEIGHTS AND VOLUMES Model height mm
500
30 °C
0.515
50 °F
0.466
Dry weight (A) Kg
9.60
35 °C
0.629
60 °F
0.590
Water content (B) Litres
5.70
40 °C
0.748
70 °F
0.721
15.30
45 °C
0.872
80 °F
0.858
N/A
50 °C
1.000
90 °F
1.000
300
55 °C
1.132
100 °F
1.147
60 °C
1.267
110 °F
1.298
65 °C
1.406
120 °F
1.454
70 °C
1.549
130 °F
1.613
Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
ADDITIONAL INFORMATION Material
Mild steel
Steel tube measurements
See dimensions table
Steel thickness
Upright Cross tubes
Maximum working pressure
1.5mm 1.2mm 2 bar/200 kPa
Testing pressure
12 bar/1200 kPa
Maximum working temperature
70°C
Configuration
1100 high
3 banks/22 tubes (4 + 8 + 10)
1200 high
3 banks/24 tubes (4 + 8 + 12)
75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT
APOLLO napoli sealed electric straight multirail technical specification 30
30 450/500/600
45-60
500/600
45-60 15
Dt
15
Dt
114
126
128
1700
1500
114
114
128
Db
15
40
40
front view A
Db
15
side view
40
40
front view top view A side view
top view
NAPOLI STRAIGHT DIMENSIONS (mm) Height of radiator 1500, 1700 Width of radiator Upright tube dimensions
450
500
600
30 x 40
30 x 40
30 x 40
Cross tube diameter Wall to front of rad
(A)
Wall to pipe centres
22
22
22
85 - 100
85 - 100
85 - 100
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Side entry Bottom entry
(B)
Distance between tappings
Side entry
Pipe centres
Side entry Bottom entry
Bracket position
Top Bottom
(Db)
Bottom entry
(C)
N/A
N/A
N/A
N/A
N/A
N/A
(C)
N/A
N/A
N/A
(Dt)
90
90
90
90
90
90
NAPOLI STRAIGHT 1500 HIGH WEIGHTS AND VOLUMES Model width mm Dry weight (A) Kg Water content (B) Litres Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
TEMPERATURE
500
600
11.10
11.90
13.50
6.60
7.10
8.00
17.70
19.00
21.50
5 °C
0.050
450
450
450
10 °C
0.123
10 °F
0.057
300
450
450
15 °C
0.209
20 °F
0.142
20 °C
0.304
30 °F
0.240
25 °C
0.406
40 °F
0.348
30 °C
0.515
50 °F
0.466
35 °C
0.629
60 °F
0.590
40 °C
0.748
70 °F
0.721
45 °C
0.872
80 °F
0.858
50 °C
1.000
90 °F
1.000
55 °C
1.132
100 °F
1.147
60 °C
1.267
110 °F
1.298
65 °C
1.406
120 °F
1.454
70 °C
1.549
130 °F
1.613
NAPOLI STRAIGHT 1700 HIGH WEIGHTS AND VOLUMES Model height mm
500
600
Dry weight (A) Kg
13.50
15.30
8.00
9.10
21.50
24.40
450
600
450
600
Water content (B) Litres Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
ADDITIONAL INFORMATION Material
Mild steel
Steel tube measurements
See dimensions table
Steel thickness
Upright Cross tubes
Maximum working pressure
1.5mm 1.2mm 2 bar/200 kPa
Testing pressure
12 bar/1200 kPa
Maximum working temperature
70°C
Configuration
FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)
450
1500 high
4 banks/30 tubes (4 + 8 + 8 + 10)
1700 high
4 banks/34 tubes (4 + 10 + 10 + 10)
75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT
APOLLO napoli sealed electric multirail curved technical specification 30
30
45-60
450/500/600
500
45-60
15
Dt
15
Dt
146
800
700
166
Db
15
40
40
front view
Db
A
15 40
side view
40
front view
A top view side view
top view
NAPOLI CURVED DIMENSIONS (mm) Height of radiator 700, 800 Width of radiator Upright tube dimensions
450
500
600
30 x 40
30 x 40
30 x 40
Cross tube diameter Wall to front of rad
22
22
22
95
100
110
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
(A)
Wall to pipe centres
Side entry Bottom entry
(B)
Distance between tappings
Side entry
Pipe centres
Side entry Bottom entry
Bracket position
Top Bottom
(Db)
Bottom entry
(C)
N/A
N/A
N/A
N/A
N/A
N/A
(C)
N/A
N/A
N/A
(Dt)
90
90
90
90
90
90 TEMPERATURE
NAPOLI CURVED 700 HIGH WEIGHTS AND VOLUMES Model width mm
450
500
600
FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)
Dry weight (A) Kg
5.50
5.90
6.60
Water content (B) Litres
3.10
3.30
3.80
Working weight (A+B) Kg
8.60
9.20
10.40
5 °C
0.050
ΔT=50k Chrome outputs: Watts ΔT=50k
200
200
200
10 °C
0.123
10 °F
0.057
200
200
200
15 °C
0.209
20 °F
0.142
20 °C
0.304
30 °F
0.240
25 °C
0.406
40 °F
0.348
White outputs: Watts
NAPOLI CURVED 800 HIGH WEIGHTS AND VOLUMES Model height mm
500
30 °C
0.515
50 °F
0.466
Dry weight (A) Kg
6.60
35 °C
0.629
60 °F
0.590
Water content (B) Litres
3.80
40 °C
0.748
70 °F
0.721
10.40
45 °C
0.872
80 °F
0.858
N/A
50 °C
1.000
90 °F
1.000
200
55 °C
1.132
100 °F
1.147
60 °C
1.267
110 °F
1.298
65 °C
1.406
120 °F
1.454
70 °C
1.549
130 °F
1.613
Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
ADDITIONAL INFORMATION Material
Mild steel
Steel tube measurements Steel thickness
See dimensions table Upright Cross tubes
Maximum working pressure
1.5mm 1.2mm 2 bar/200 kPa
Testing pressure
12 bar/1200 kPa
Maximum working temperature
70°C
Configuration
700 high
2 banks/14 tubes (4 + 10)
800 high
2 banks/16 tubes (4 + 12)
75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT
APOLLO napoli sealed electric curved multirail technical specification 30
30 450/500/600
45-60
500
45-60 15
Dt
15
Dt
132
1200
1100
122
132
122
Db
15 front view
40
Db
40
15
40
A
40
front view side view
A top view
side view top view
NAPOLI CURVED DIMENSIONS (mm) Height of radiator 1100, 1200 Width of radiator Upright tube dimensions
450
500
600
30 x 40
30 x 40
30 x 40
Cross tube diameter Wall to front of rad
22
22
22
95
100
110
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
(A)
Wall to pipe centres
Side entry Bottom entry
(B)
Distance between tappings
Side entry
Pipe centres
Side entry Bottom entry
Bracket position
Top Bottom
(Db)
Bottom entry
(C)
N/A
N/A
N/A
N/A
N/A
N/A
(C)
N/A
N/A
N/A
(Dt)
90
90
90
90
90
90
TEMPERATURE
NAPOLI CURVED 1100 HIGH WEIGHTS AND VOLUMES Model width mm
450
500
600 10.10
FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)
Dry weight (A) Kg
8.30
8.90
Water content (B) Litres
4.90
5.20
5.90
13.20
14.10
16.00
5 °C
0.050
300
300
300
10 °C
0.123
10 °F
0.057
200
300
300
15 °C
0.209
20 °F
0.142
20 °C
0.304
30 °F
0.240
25 °C
0.406
40 °F
0.348
Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
NAPOLI CURVED 1200 HIGH WEIGHTS AND VOLUMES Model height mm
500
30 °C
0.515
50 °F
0.466
Dry weight (A) Kg
9.70
35 °C
0.629
60 °F
0.590
5.70
40 °C
0.748
70 °F
0.721
15.40
45 °C
0.872
80 °F
0.858
N/A
50 °C
1.000
90 °F
1.000
300
55 °C
1.132
100 °F
1.147
60 °C
1.267
110 °F
1.298
65 °C
1.406
120 °F
1.454
70 °C
1.549
130 °F
1.613
Water content (B) Litres Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
ADDITIONAL INFORMATION Material
Mild steel
Steel tube measurements Steel thickness
See dimensions table Upright Cross tubes
Maximum working pressure
1.5mm 1.2mm 2 bar/200 kPa
Testing pressure
12 bar/1200 kPa
Maximum working temperature
70°C
Configuration
1100 high
3 banks/22 tubes (4 + 8 + 10)
1200 high
3 banks/24 tubes (4 + 8 + 12)
75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT
APOLLO napoli sealed electric curved multirail technical specification 30 500/600
45-60 30
15
Dt
450/500/600
45-60
15
Dt
126 114
1700
128
1500
114
114
Db
128
15
40
Db
15
40
front view
40
A
40
front view
side view
A top view
top view
side view
NAPOLI CURVED DIMENSIONS (mm) Height of radiator 1500, 1700 Width of radiator Upright tube dimensions
450
500
600
30 x 40
30 x 40
30 x 40
Cross tube diameter Wall to front of rad
22
22
22
95
100
110
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
(A)
Wall to pipe centres
Side entry Bottom entry
(B)
Distance between tappings
Side entry
Pipe centres
Side entry Bottom entry
Bracket position
Top Bottom
(Db)
Bottom entry
(C)
N/A
N/A
N/A
N/A
N/A
N/A
(C)
N/A
N/A
N/A
(Dt)
90
90
90
90
90
90
NAPOLI CURVED 1500 HIGH WEIGHTS AND VOLUMES Model width mm Dry weight (A) Kg Water content (B) Litres Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
TEMPERATURE
500
600
11.20
12.00
13.50
6.60
7.10
8.00
17.80
19.10
21.50
5 °C
0.050
450
450
450
10 °C
0.123
10 °F
0.057
300
450
450
15 °C
0.209
20 °F
0.142
20 °C
0.304
30 °F
0.240
25 °C
0.406
40 °F
0.348
30 °C
0.515
50 °F
0.466
35 °C
0.629
60 °F
0.590
40 °C
0.748
70 °F
0.721
45 °C
0.872
80 °F
0.858
50 °C
1.000
90 °F
1.000
55 °C
1.132
100 °F
1.147
60 °C
1.267
110 °F
1.298
65 °C
1.406
120 °F
1.454
70 °C
1.549
130 °F
1.613
NAPOLI CURVED 1700 HIGH WEIGHTS AND VOLUMES Model height mm
500
600
Dry weight (A) Kg
13.50
15.30
8.00
9.10
21.50
24.40
450
600
450
600
Water content (B) Litres Working weight (A+B) Kg
ΔT=50k Chrome outputs: Watts ΔT=50k
White outputs: Watts
ADDITIONAL INFORMATION Material
Mild steel
Steel tube measurements
See dimensions table
Steel thickness
Upright Cross tubes
Maximum working pressure
1.5mm 1.2mm 2 bar/200 kPa
Testing pressure
12 bar/1200 kPa
Maximum working temperature
70°C
Configuration
FACTORS FOR DIFFERENCES BETWEEN MEAN WATER TEMPERATURE AND ROOM TEMPERATURE IN °C AND °F OTHER THAN 50 °C (90 °F)
450
1500 high
4 banks/30 tubes (4 + 8 + 8 + 10)
1700 high
4 banks/34 tubes (4 + 10 + 10 + 10)
75 °C 1.694 140 °F 1.776 TO APPLY THE FACTORS SHOWN IN THE TABLE TO OUR QUOTED OUTPUTS. MULTIPLY THE QUOTED OUTPUT BY THE CHOSEN OPERATING FACTOR TO GIVE THE OUTPUT