APP - TAPPAN PRODUCTS - JULY 2012 - Southwire

Report 5 Downloads 90 Views
100 Bradley Parkwy Blauvelt, NY 10913 Phone: 1-800-WIRE-911-Fax 1-845-353-9315

31SR

Multiconductor - Riser Rated - Shielded -- Bare Copper / PVC APPLICATIONS

CONSTRUCTION A.) CONDUCTOR B.) INSULATION C.) COLOR CODE D.) SHIELDING E.) ASSEMBLY F.) JACKET COMPLIANCE A.) FLAME TEST B.) CABLE TYPE C.) VOLTAGE D.) TEMPERATURE E.) SUITABLE USE: F.) QA FEATURES & OPTIONS:

SW PART NUMBER

575721 575722 575724 575725 575723

575726 575727 575728 578913

TAPPAN SPEC # R20540.1 R20384.1 R20007.1 R20016.1 R20030.1 R20775.19 R20076.1 R20077.1 R20024.1 R20078.1 R20488.1 R20081.1 R20084.1 R30024.1 R30041.1 R30042.1 R30044.1

DESCRIPTION 22/2C SOL BC OAS CMR/CL3R 22/4C SOL BC OAS CMR/CL3R 22/2C STR BC OAS CMR/CL3R 22/3C STR BC OAS CMR/CL3R 22/4C STR BC OAS CMR/CL3R 22/5C STR BC OAS CMR/CL3R 22/6C STR BC OAS CMR/CL3R 22/7C STR BC OAS CMR/CL3R 22/8C STR BC OAS CMR/CL3R 22/9C STR BC OAS CMR/CL3R 22/10C STR BC OAS CMR/CL3R 22/12C STR BC OAS CMR/CL3R 22/15C STR BC OAS CMR/CL3R 20/2C STR BC OAS CMR/CL3R 20/3C STR BC OAS CMR/CL3R 20/4C STR BC OAS CMR/CL3R 20/6C STR BC OAS CMR/CL3R

22 AWG & 20 AWG

Remote Control, Signalling, and Power-Limited circuits per NEC Article 725. 22AWG - 16 AWG also as communication circuits per NEC Article 800. Security, sound and audio, speaker cable, public address, intercom, sound reinforcement, alarm and access control circuits and power-limited controls. Stranded or solid bare copper as indicated on on individual product specifications. PVC or Polypropylene Listed below chart. Also listed for each item on individual specification sheets. Overall - Aluminum foil, polyester reinforced tape and stranded tinned copper drain wire. Cabled, Shielded, ripcord under jacket; jacketed. PVC

UL 1666 CL3R. Also CMR where UL permits (Sizes 16 AWG and smaller.) 300V 75C General purpose low voltage and power-limited systems' circuits to NEC Article 725 16 AWG and smaller also for communications circuits to NEC Article 800. UL listed to UL 444 and UL 13 as applicable. Available in 1000ft or 500 ft packages, reels, or pull-boxes where practicable. Optional: other colors, jackets with extruded stripes, and composite cables for multiple services, jacketed, armored, or armored and jacketed. Cable Type

CABLE

CABLE

AWG

22

20

#COND 2 4 2 3 4 5 6 7 8 9 10 12 15 2 3 4 6

STRANDED /SOLID

BC/ TD

SHIELD

BC

OAS

BC

OAS

SOL

STR

STR

NOM. DIA. WEIGHT (Inches) (lbs/Mft) 0.113 10 0.130 16 0.120 11 0.128 14 0.139 17 0.146 20 0.157 23 0.175 27 0.181 29 0.185 34 0.194 35 0.225 40 0.230 49 0.132 14 0.141 18 0.153 23 0.174 31

JACKET COLOR

UL/NEC

Gray

CMR/CL3R

Gray

CMR/CL3R

Color Code: Black, Red, White, Green, Brown, Blue, Orange, Yellow, Violet, Gray, Pink, Beige -- or per individual specification sheet detail.

31SR March 2013

Page 1 of 2

(C) 2013 Tappan Wire Cable

100 Bradley Parkwy Blauvelt, NY 10913 Phone: 1-800-WIRE-911-Fax 1-845-353-9315

31SR

Multiconductor - Riser Rated - Shielded -- Bare Copper / PVC APPLICATIONS

CONSTRUCTION A.) CONDUCTOR B.) INSULATION C.) COLOR CODE D.) SHIELDING E.) ASSEMBLY F.) JACKET COMPLIANCE A.) FLAME TEST B.) CABLE TYPE C.) VOLTAGE D.) TEMPERATURE E.) SUITABLE USE: F.) QA FEATURES & OPTIONS:

SW PART NUMBER 575731 575729 575730 575734 575732 581293 575733 575705 575736 575735 575737 580224 581289 576442

TAPPAN SPEC # R40013.1 R40003.1 R40005.1 R40070.1 R40611.1 R40071.1 R40014.1 R40073.1 R40098.1 R40075.1 A50039.1 R50044.1 R50031.1 R50033.1 R60052.1 R60023.1 R60024.1 R70010.1 R70011.1 R70012.1

DESCRIPTION 18/2C STR BC OAS CMR/CL3R 18/3C STR BC OAS CMR/CL3R 18/4C STR BC OAS CMR/CL3R 18/5C STR BC OAS CMR/CL3R 18/6C STR BC OAS CMR/CL3R 18/7C STR BC OAS CMR/CL3R 18/8C STR BC OAS CMR/CL3R 18/9C STR BC OAS CMR/CL3R 18/10C STR BC OAS CMR/CL3R 18/12C STR BC OAS CMR/CL3R 16/2C STR BC OAS CMR/CL3R 16/3C STR BC OAS CMR/CL3R 16/4C STR BC OAS CMR/CL3R 16/6C STR BC OAS CMR/CL3R 14/2C STR BC OAS CL3R/FPLR 14/3C STR BC OAS CL3R/FPLR 14/4C STR BC OAS CL3R/FPLR 12/2C STR BC OAS CL3R/FPLR 12/3C STR BC OAS CL3R/FPLR 12/4C STR BC OAS CL3R/FPLR

18 AWG thru 12 AWG

Remote Control, Signalling, and Power-Limited circuits per NEC Article 725. 22AWG - 16 AWG also as communication circuits per NEC Article 800. Security, sound and audio, speaker cable, public address, intercom, sound reinforcement, alarm and access control circuits and power-limited controls. Stranded or solid bare copper as indicated on on individual product specifications. PVC or Polypropylene Listed below chart. Also listed for each item on individual specification sheets. Overall - Aluminum foil, polyester reinforced tape and stranded tinned copper drain wire. Cabled, Shielded, ripcord under jacket; jacketed. PVC

UL 1666 CL3R. Also CMR where UL permits (Sizes 16 AWG and smaller.) 300V 75C General purpose low voltage and power-limited systems' circuits to NEC Article 725 16 AWG and smaller also for communications circuits to NEC Article 800. UL listed to UL 444 and UL 13 as applicable. Available in 1000ft or 500 ft packages, reels, or pull-boxes where practicable. Optional: other colors, jackets with extruded stripes, and composite cables for multiple services, jacketed, armored, or armored and jacketed. Cable Type

AWG

CABLE

18

COND

16

CABLE

14

CABLE

12

#COND 2 3 4 5 6 7 8 9 10 12 2 3 4 6 2 3 4 2 3 4

STRANDED /SOLID

BC/ TD

SHIELD

STR

BC

OAS

STR

BC

OAS

STR

BC

OAS

STR

BC

OAS

NOM. DIA. WEIGHT (Inches) (lbs/Mft) 0.156 19 0.167 26 0.182 32 0.192 39 0.230 46 0.232 52 0.241 59 0.257 68 0.265 71 0.281 83 0.180 27 0.193 37 0.212 48 0.242 68 0.218 40 0.244 57 0.257 72 0.266 59 0.296 87 0.326 113

JACKET COLOR

UL/NEC

Gray

CMR/CL3R

Gray

CMR/CL3R

Gray

CL3R/FPLR

Gray

CL3R/FPLR

Color Code: Black, Red, White, Green, Brown, Blue, Orange, Yellow, Violet, Gray, Pink, Beige -- or per individual specification sheet detail.

31SR March 2013

Page 2 of 2

(C) 2013 Tappan Wire Cable