Assembly!Hall!–!Rainy!Hall! !
!
! ! Capacity:!265! Mound!Place,!EH1!2LX! !
Schedule C Rainy Hall Outline description of the stage and technical facilities provided by Assembly.
1.
SEATING
2.
THE STAGE
3.
MASKING
4.
SUSPENSION
5.
LIGHTING
Rainy Hall is an end on theatre space with a raked auditorium with 256 seats, to increase performance area the front two rows of seating can be removed.
The performance area is 8.0m wide x 4.0m (up to 5.5m with the front two rows removed) deep covered in black dance floor. There is a Fire Exit up stage right to which access of a corridor of 1.2m must be maintained, this is also the access/egress for wheelchair users, it may be necessary to use this as access before and after your performance. There is no crossover available. It is not permissible to screw into the venue floors and walls.
Black box. No wing area. No Crossover.
The underside of the truss is approximately 4.75m above the stage. There are no flying facilities. Lightweight items of scenery may be hung from the grid on single lines at the discretion of the Technical Manager.
The lighting control position is located at the rear of the auditorium. It may be possible for one person to operate both lighting and sound. CONTROL: ETC ION DIMMERS: 48 x 10Amp POWER SUPPLY MAXIMUM LOAD: 40 kW FIXED RIG MOVING LIGHTS: (Exact specifications subject to change) - 1 x Martin Mac 700 Profile (available for hire) - 4 x Martin Mac Aura XB Wash (available for hire) A good general cover of warm and cool light over the performance area is provided. The position and focus of these lanterns may not be changed, however they may be coloured for your show, provided this is possible within your set-up and strike time. Additional lanterns can be rigged as company specials but must come from the stock of Assembly Theatre’s supplier. These units will be charged as an additional cost. Moving lights in the fixed rig are available for hire. Blackout on stage is acceptable; however, absolute blackout is not possible due to emergency lighting regulations. We do not allow companies to bring their own lights.
Rainy Hall June 15
For the most up to date plans and technical specifications, please liaise with the Head of Lighting in the lead up to the festival. Please note these specifications are subject to change.
6.
SOUND
The control position is located at the rear of the auditorium. It may be possible for one person to operate both lighting and sound. We do not allow companies to bring their own sound equipment. System : L-Acoustics L&R Line array system with centre and rear fills – plans available on request. Monitors: 2 x Flown monitors and 2 x floor monitors are available. FOH Desk: Digico SD9 48 Input Digital Console with on board processing and effects FOH Playback 1: 1 x Qlab playback machine FOH Playback 2: 1 x 3.5mm Jack inputs The basic rig also includes 4 wired dynamic SM58 microphones and 4 DI boxes. For information and costs for radio microphones please contact the Head of Sound. Additional microphones, other sound equipment and backline equipment is available for hire. This equipment is provided by Assembly Festival’s supplier and will be charged as an additional cost – details on request. All sound equipment must be agreed in advance with the Head of Sound or the Technical Manager.
7.
DRESSING ROOM
8.
STORAGE
9.
ACCESS
There are two dressing rooms to be shared by all the companies in the venue. Tables, chairs and mirrors are provided for communal use. The management cannot accept responsibility for the security of any items left in the dressing room. You will have access to the storage and dressing room 40 minutes before and for 20 minutes after your performance each day.
Backstage storage is extremely limited and we recommend that companies keep their scenery/props requirements to an absolute minimum. The maximum size for flat scenery is 3.0m tall x 1.8m width carried on edge. Small items of scenery and props may be stored in the dressing room at the discretion of the Technical Manager. It is not possible to provide storage space in other parts of the building. It is worth ensuring that your set is light yet durable enough to withstand daily dismantling. ALL SET ITEMS ARE REQUIRED TO EASILY PASS THROUGH A STANDARD DOOR 1M wide x 1.9M.
Rainy Hall is accessible from: Mound Place EH1 2LX. Load in and access is via the Quad and up a large stone staircase. Careful reference to the images and dimensions below is essential. The venue is on the first floor with access from the street by way of multiple staircases.
Rainy Hall June 15
Please check before attempting to bring large pieces of scenery - they may not fit through the doors. Access to the stage is from a door stage right and via the auditorium via steps. There is one audience entrance/exit in the seating bank. There is a Fire Exit up stage right to which access of a corridor of 1.2m must be maintained, this is also the access/egress for wheelchair users, it may be necessary to use this as access before and after your performance. Please note that these must be kept clear as emergency exits.
10.
STAFF
The theatre personnel work on a rota basis. The duty rota comprises one stage manager, one lighting technician and one sound technician. If the visiting manager requires additional staff to assist with the turn around, or the use of casual crew during the load in or load out, then this can be organised at additional cost. If the venue technical staff are required to participate for anything more than lights up /lights down (one cue to bring the house to a performance state and mic live and then one cue to bring the house back to exit state) during the performance, the Visiting Company will be liable for a show call charge for each technician used. The rate is £25 per performance per technician plus VAT.
11.
NOTES
Any additional staff or items of equipment, which the management are requested to provide, will be charged to the visiting company. Any practical electrical equipment you wish to use should have a current PAT certificate and be cleared with us. We reserve the right to refuse the use of any equipment which is deemed unsafe. Each company is assigned a get in/rehearsal time prior to their first performance This is the time for you to load your set and props into the venue and for you to re-tech your show. You will also need to allow sufficient time to rehearse your daily turnaround and set storage. Please note that your slot time must include get-in and get-out time. Please note that, due to the Scottish Executive regulations, smoking is not permitted in any venues, including the use of herbal cigarettes. Only electronic cigarettes may be used. At the end of the festival, please arrange for removal or disposal of your set and any unused publicity material. There will be a charge applied to cover the cost of disposal should you not comply with this request. Please note, since this is a temporary conversion and not a permanent theatre, all measurement and quantities quoted in the above specification are approximate and may be subject to change. For detailed and up to date information regarding the venue please contact the Technical Manager –
[email protected] Rainy Hall June 15
assembly 2013 Rainy Hall Initial Plans SUBJECT TO CHANGE 11/4/13 Note:
7905
5018
assembly 2013 Rainy Hall Initial Plans SUBJECT TO CHANGE 11/4/13 Note:
5224
RAINY HALL VENUE
www.assemblyfestival.com
RAINY HALL VENUE
A3
START TRUSS BUILD FROM THESE BASE PLATE MEASUREMENTS.
EDINBURGH FRINGE FESTIVAL 2014 RAINY HALL VENUE
VENUE ELEVATIONS
S.HARE
P.McCABE
17.09.13
1:150
www.assemblyfestival.com 2 Roxburgh Place, Edinburgh, EH8 9SU Email: technical@assembly festival.com Tel: +44 (0)1316 233000
1
2
3
4
5
6
7
A
A 23
26
L716
L441
24
27
L716
L441
25
28
L716
L441
303
EXIT
302
X1 22
21
B
301
-4000
-3500
B
304
-3000
-2500
-2000
-1500
-1000
-500
0mm
500
1000
1500
2000
2500
3000
3500
4000
20
19
C
C
L201
L009
L201
L009
L201
L009
X2 drawing no
10
16
11
17
12
revision
sheet size
2
A3
RHLX15
18
legend
X1
Instruments
D
Used
EXIT 4
Mac 700 Profile
1
S4-26°
3
1.2kW Fresnel
22
Aisle Light
3
Mac Aura XB
4
©Steve
Shelley
2003
Coda 500
D
700 PRO
26° L201
L009
L201
L009
L201
L009
7
13
8
14
9
15
E
#119
F
#119
#119
26°
26°
4
1
©Steve
Shelley
2003
26°
E
F
700 PRO
1
701 X1
X2
X2
G
notes
G
LIGHTING CONTROL: ETC Ion DIMMERS: 48 Channels (25 ch allocated to fixed rig) Aisle Lights & House LX on Alpha Pack FIXED RIG MOVING LIGHTS
H
H
Available for Hire 1 x Mac 700 Profile 4 x Mac Aura XB (LED Wash)
EXIT NOTE: Lighting fixtures & plan are subject to change. For most up to date plan, please contact Assembly Head of Lighting.
information J
client
Assembly Festival
J
project
Edinburgh Festival 2015
venue
Rainy Hall
title designer drawn
Fixed LX Rig AL
scale
1:50
date
02-05-2015
K
K Assembly Festival 2 Roxburgh Place Edinburgh EH8 9SU T. +44 (0) 131 623 3000 http://www.assemblyfestival.com
1
2
X1
3
4
5
6
7
!