AUXILIARY SWITCH NHI-PKZ0 Part no.
NHI11-PKZ0
Article no.
072896
For motor-protective circuit-breakers
Delivery programme Contacts N/O = Normally open
1 N/O
N/C = Normally closed
1 N/C
Contact diagram
Contact sequence
Connection technique
Screw terminals
For use with
PKZM01#http://ecatalog.moeller.net/catalog? pg=Motorschutzschalter&filter=Zubeh%2525C3%2525B6r %253DNormalhilfsschalter%26Sortiment%253DZusatzausr %2525C3%2525BCstung&l=de_DE PKZM0#http://ecatalog.moeller.net/catalog? pg=Motorschutzschalter&filter=Zubeh%2525C3%2525B6r %253DNormalhilfsschalter%26Sortiment%253DZusatzausr %2525C3%2525BCstung&l=de_DE PKZM4#http://ecatalog.moeller.net/catalog? pg=Motorschutzschalter&filter=Zubeh%2525C3%2525B6r %253DNormalhilfsschalter%26Sortiment%253DZusatzausr %2525C3%2525BCstung&l=de_DE PKZM0-T#http://ecatalog.moeller.net/catalog? pg=Motorschutzschalter&filter=Zubeh%2525C3%2525B6r %253DNormalhilfsschalter%26Sortiment%253DZusatzausr %2525C3%2525BCstung&l=de_DE PKM0#http://ecatalog.moeller.net/catalog? pg=Motorschutzschalter&filter=Zubeh%2525C3%2525B6r %253DNormalhilfsschalter%26Sortiment%253DZusatzausr %2525C3%2525BCstung&l=de_DE PKZ-Grundgerät#http://ecatalog.moeller.net/catalog? pg=Motorschutzschalter&filter=Zubeh%2525C3%2525B6r %253DNormalhilfsschalter%26Sortiment%253DZusatzausr %2525C3%2525BCstung&l=de_DE
Notes Can be fitted to the right of motor-protective circuit-breakers, transformer-protective circuit-breakers, motor-protective circuit-breakers for starter combinations. Can be combined with: AGM, NHI-E-... trip-indicating auxiliary contact Notes
Accessories 1 Motor-protective circuit-breakers 5 Trip-indicating auxiliary contact Additional accessories
07/28/2010
# 072730 # 072898 # 106132
1
Auxiliary contacts Rated impulse withstand voltage
Uimp
V AC
Overvoltage category/pollution degree Rated operational voltage
6000 III/3
Ue
V
Ue
V AC
500
Ue
V DC
250
V AC
690
Safe isolation to VDE 0106 Part 101 and Part 101/A1 Between auxiliary contacts and main contacts Rated operational current
Ie
A
220 – 240 V
Ie
A
3.5
380 – 415 V
Ie
A
2
440 – 500 V
Ie
A
1
24 V
Ie
A
2
60 V
Ie
A
1.5
110 V
Ie
A
1
220 V
Ie
A
0.25
AC–15
DC-13 L/R – 100 ms
Lifespan
S 6
> 0.1
× 10
6
0.05
#
< 10
Lifespan, mechanical
Operations
× 10
Lifespan, electrical
Operations Failure rate
Control circuit reliability (at Ue = 24 V DC, Umin = 17 V, I min= 5.4 mA)
-8
Interlocked opposing contacts to ZH 1/457
8
< 1 failure at 1 × 10 operations
Yes
Short-circuit rating without welding deltaEK Fuse
FAZ-B4/1-HI A gG/gL
10
Terminal capacities 2
Solid or flexible conductor with ferrule
mm
Solid or stranded
AWG
0.75 – 2.5 18 – 14
Dimensions
07/28/2010
2
07/28/2010
3
Recommend Documents
Auxiliary Switch
Part no. SL7-BL230-G Article no. 171397 Catalog No
AUXILIARY CONTACTS NHI-PKZ2 Part no. NHI11-PKZ2 ... - Farnell
UPB Wall Switch and Auxiliary Switch - Leviton
Part no. SL4-L24-G Article no. 171314 Catalog No. SL4 ...
Part no. SL4-L24-Y Article no. 171317 Catalog No. SL4-L24-Y ...
Part no. SL7-BL230-R Article no. 171398 Catalog No. SL7-BL230-R ...
×
Report AUXILIARY SWITCH NHI-PKZ0 Part no. NHI11-PKZ0 Article no ...
Your name
Email
Reason
-Select Reason-
Pornographic
Defamatory
Illegal/Unlawful
Spam
Other Terms Of Service Violation
File a copyright complaint
Description
×
Sign In
Email
Password
Remember me
Forgot password?
Sign In
Login with Facebook
Our partners will collect data and use cookies for ad personalization and measurement.
Learn how we and our ad partner Google, collect and use data
.
Agree & Close