Features • 100mm axial flow fan • Suitable for wall and ceiling installations with up to 3m of 100mm ducting • Various control options including SELV • Built in guide vanes to improve airflow
Physical specification
• Anti-backdraught shutters
All measurements in millimetres.
• Clever spigot strengtheners to prevent crushing when attaching flexible ducting
154
27
Cable surface entry
• Stylish design for discreet finish 84
154
Model
99
Controls Operation
IP
Voltage
AXS100
Basic to light switch.
24
230
AXS100PC
With pull cord.
24
230
AXS100T
Overrun timer and pull cord. 24
230
AXS100TR
Overrun timer no pull cord.
24
230
AXS100HT
Humidistat/timer & pull cord. 24
230
AXS100SVIT
SELV with overrun timer and pull cord.
57
12
57
12
111
Front
27
154
99
84
AXS100SVIHT SELV with humidistat/timer and pull cord. Full details of control options on page 045.
111
Installation
Side
Wiring:
Must comply with IEE Regulations, see wiring diagrams on page 043.
147
102
102
Installation: Diagrams, see page 042.
65
Transformer
Weight: 0.54 kg Materials: White satin finish. ABS plastic. 026 Greenwood specifiers GUIDE MARCH 2009
Cable:
1.5mm2 Ø max.
Fuse:
3 amp normally required (when fan is supplied from a 6A lighting circuit no local fuse is required).
Select: Bathrooms Performance
Model
Performance to BS 848 Pt1 in free air l.s-1 m3.h-1
Sound Pressure level @ 3m dB(A)
AXS100
72
20
35.1
AXS100PC
72
20
35.1
AXS100T
72
20
35.1
AXS100TR
72
20
35.1
AXS100HT
72
20
35.1
AXS100SVIT
72
20
35.1
AXS100SVIHT
72
20
35.1
25
ED1 Easyfix 100mm ducting plastic wall liner with integral screw-fixing channels for one visit installation (page 145). Flexiduct Flexible 100mm PVC and aluminium ducting (page 146).
25
20
EG1 Complementary fixed blade louvred grille in semi-matt ABS plastic, UV stabilised. Choice of white or brown grille (page 148).
20
Static Pressure Pa
Static Pressure Pa
Ancillaries
15
LRB Plastic wall baffle for low rise and sheltered sites. Available in various colours (page 148).
15
10 10 5
0
RAB Plastic recessed air brick with integral housing and PVC duct seal. Available in various colours (page 148).
5
0
0
0
5
5 1 0 1 0 1 5 1 5 2 0 2 0 2 5 2 5 3 03 0
AXS100 Range AXS100 Range Electrical Specification: Consumption:
Air Flow l/s l/s Air Flow
FF100 Fast fix wall duct system. Comprises 100mm PVC duct, external wall duct seal and external grille, choice of white or brown grille (page 144). GG42 External louvred wall vent available in white or brown (page 140).
230V~50Hz Class II 16W MARKED 19W (AXS100SVIT/SVIHT)
SELV: To maintain the fan’s performance within 2% of the published figure, the following lengths of cable between the fan and transformer should not exceed:–
IP57
RATED
IP24
RATED
5
GUARANTEE
Conductor Size (Area2)
0.50 0.75 1.00 1.50 MARKED
Specification
YEAR
(SELV)
MARKED
Max. Cable Length
1.5m
IP57
2.3m
RATED (SELV)
3.0m
COMPLIES TO: LOW VOLTAGE DIRECTIVE EMC COMPATIBILITY DIRECTIVE
IP24
RATED
5 YEAR
GUARANTEE
4.5m
IP57
RATED (SELV) MARKED
2 YEAR
MARKED GUARANTEE
IP24 IP57
RATED RATED
IP57 IP44
RATED (SELV) RATED
2 YEAR
GUARANTEE
5 YEAR IP24
GUARANTEE RATED
IP24 IPX4
RATED
IP44
RATED
(SELV)
COMPLIES TO: LOW VOLTAGE DIRECTIVE EMC COMPATIBILITY DIRECTIVE