S3S - Three-Stage Boiler Control Overview The S3S is a Three-Stage Boiler Control which can stage up to three boilers using PID logic for better control of the system temperature. The S3S will enable just enough stages to maintain either a fixed or an outdoor reset set point. The S3S has multiple uses including: Staging three Triangle Tube Boilers to maintain the desired set point for either heating or domestic applications. Staging between multiple sources of heat such as Solar, Geothermal Systems and a Triangle Tube Boiler.

Features •

Stage 3 Triangle Tube Boilers The S3S can be configured to stage up to three Triangle Tube Boilers to maintain the desired system set point.



Fixed Lead Stage or Automatic Rotation The S3S can be configured to always start with the same stage or automatically rotate the lead stage to equalize runtimes.



Stage 2 Triangle Tube Boilers with a System Pump The S3S can also be configured to stage up to two Triangle Tube Boilers and operate the System Pump.



External Enable The S3S can be remotely enabled from an external device or controller.



System Pump Run-On The S3S can be configured to provide the System Pump with an additional Run-On time to disburse heat from the boilers.



Sensor Fault Operation The S3S provides the option of switching on or off all stages if a sensor fault should occur.



Fixed Set Point or Outdoor Reset The S3S can stage up to three boilers to maintain either a fixed set point or operate using the outdoor reset function. The outdoor reset function utilizes fixed reset curves as well as providing the option for custom user defined heating curves.



Digital Display Large 2 x 16 character display provides status information as well as easy parameter adjustments in plain English.



English or Metric Units The S3S can be configured to operate using either English or Metric units.



Mounting Options The S3S can be mounted on a standard 4” x 4” electrical box or can be panel mounted using the included plastic wiring enclosure.



Outdoor Cutoff The optional Outdoor Cutoff function can disable the system when the outdoor temperature rises and heat is no longer required.

Part #

Item Description

PSCON14

S3S Three-Stage Boiler Control (Includes System and Outdoor Temperature Sensors)

S3S Specifications Voltage Input: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC 60 Hz (2 Black wires) / 24 VAC 60 Hz (24VAC Terminals) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(Only One Power Source) Power Consumption: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 VA Max Operating Temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . .20ºF (-7ºC )to 120ºF (49ºC) Operating Humidity: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20% to 80% Dimensions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4”W x 4”H x 2 1/2” Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 pound Outputs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 S.P.S.T (Yellow = Output A) (Blue = OutputB), (White = Output C.) Output Relay Ratings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Amp inductive(Maximum of 1/8 HP), 6 Amp resistive at 120 VAC 60 Hz Control Modes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Outdoor Reset, Set Point Output Modes: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Boiler + 1-Pump, 1 Boiler+2-Pump, 1-Lo/Hi+1-Pump, 2 Boilers+1-Pump, 3 Boilers Lead Rotation : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Manual or Time (1Hr to 999 Hr) Purge Delay: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.0 to 10.0 minutes Reaction Time: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 to 10 minutes Minimum Runtime: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 to 60 minutes Reset Ratios: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Standard ranging from 8:1 to 1:4 (Outdoor: System), and one Custom Offset: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40ºF (-22ºC) to 40ºF (+22ºC) Minimum Target: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70ºF (21ºC) to 170ºF (77ºC) Maximum Target: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90ºF (32ºC) to 240ºF (116ºC) Set Point: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-10ºF (-23ºC) to 230ºF (110ºC) Pump Run-On: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0 to 60 minutes DHW Priority Timer Options: . . . . . . . . . . . . . . . . . . . . . . . .No Priority, Priority from 1 to 120 minutes Setback: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0ºF (0ºC) to 80ºF (44ºC) Boost: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Yes, No Sensor Fault Operating Options: . . . . . . . . . . . . . . . . . . . . .Output ON or Output OFF Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Back Lite Alphanumeric (2 rows x 16 char. each) LEDs: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 representing the Output Relays Buttons: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 (Set, Up, Down) Prestige Boilers SYSTEM = TARGET =

147 °F 150 °F

OUTPUT A OUTPUT B OUTPUT C

Outdoor Sensor

S3S Application:

SET

prestige

prestige

prestige

The S3S monitors the header temperature and stages the Prestige Solo Boilers as required to maintain set point.

S3S Sensor