cased and uncased coils - Republic Plumbing Supply

Report 0 Downloads 14 Views
CASED AND UNCASED COILS High quality coils are designed for use with split system air conditioning and heat pumps, and are AHRI matched to Heat Controller models. Rifled copper tubing with aluminum fins for optimum heat transfer Installation flexiblity with right or left hand connections for refrigerant and plumbing Factory-installed TX valve for precise refrigerant control Heavy duty drain pan is made of polyproplene for corrosion resistance (5 ton models have metal drain pan); multi-position coils also have a powder coated galvanized steel horizontal drain pan Durable, attractive cabinet of embossed, galvanized steel has furnace connections built in (cased models) Factory tested with immersion test at 500 psi, then nitrogen pressurized and factory sealed CASED COILS: Fully insulated cabinet for quiet operation

MCG Series

Multi-Position Cased Coil

VCG Series

Upflow/Downflow Cased Coil

Split front panel provides easy access for service Plate kit for field conversion to downflow configuration is included

These coils are AHRI certified for system applications when matched with Heat Controller outdoor units (heat pumps and condensing units). See applicable condensing unit or heat pump specification sheets for exact matches.

CCG Series Uncased Coil

MULTI-POSITION CASED COIL COIL MODELS

W = CABINET WIDTH (inches)

D = CABINET DEPTH (inches)

CH= CABINET HEIGHT (inches)

FITS FURNACE WIDTH (inches)

SHIPPING WEIGHT I(bs)

MCG24TA1E MCG24TB1E MCG36TA1E MCG36TB1E MCG36TC1E MCG48TB1E MCG48TC1E MCG48TD1E MCG60TC1E MCG60TD1E

14 171/2 14 171/2 21 171/2 21 241/2 21 241/2

201/2 201/2 201/2 201/2 201/2 21 21 21 21 21

19 19 23 23 23 27 27 27 30 30

141/4

39 41 52 54 56 65 68 71 78 81

14 171/2 14 171/2 21 171/2 21 241/2 21 241/2

201/2 201/2 201/2 201/2 201/2 21 21 21 21 21

19 19 23 23 23 27 27 27 30 30

141/4

17 /

1 2

141/4 171/2 21 171/2 21 241/2 21 241/2

HIGH EFFICIENCY COIL MODELS

MCG24TA2E MCG24TB2E MCG36TA2E MCG36TB2E MCG36TC2E MCG48TB2E MCG48TC2E MCG48TD2E MCG60TC2E MCG60TD2E

54 56 69 71 73 84 87 90 95 99

171/2 141/4 171/2 21 171/2 21 241/2 21 241/2

t

Liquid line: 3/8" ODS, suction line 3/4" ODS on 2 and 3 ton units, 7/8" ODS on 4 and 5 ton units. For bottom duct opening dimensions, subtract 3/4" from width or depth. For top duct opening, subtract 1-1/2" from width or depth.

H

t

t

Do not use coils with polypropylene drain pans on oil furnaces or other applications where outlet temperatures exceed 300o F.

C = Coil Uncased, Upflow/Downflow M = Coil Cased, Multi-Position V = Cased Coil, Upflow/ Dowflow

C G 24 T CopperTube, Aluminum Fin

‘Green’ Gas R-410A

Capacity BTUH x 1000

TXV

2

A

Cabinet/Coil Size A = 14" Wide B = 171/2" Wide C = 21" Wide D = 241/2" Wide

t

W

t

MODEL NOMENCLATURE C

D

t

1 1 = Standard 2 = High Efficiency

E

Series/ Revision

UPFLOW/DOWNFLOW CASED COIL COIL MODELS

W = CABINET WIDTH (nches)

D = CABINET DEPTH (inches)

H = CABINET HEIGHT (inches)

FITS FURNACE WIDTH (inches)

SHIPPING WEIGHT I(bs)

VCG24TA1E VCG24TB1E VCG36TA1E VCG36TB1E VCG36TC1E VCG48TB1E VCG48TC1E VCG48TD1E VCG60TC1E VCG60TD1E

14 171/2 14 171/2 21 171/2 21 241/2 21 241/2

201/2 201/2 201/2 201/2 201/2 21 21 21 21 21

16 16 20 20 20 24 24 24 28 28

141/4

37 39 50 52 54 62 65 68 75 78

14 171/2 14 171/2 21 171/2 21 241/2 21 241/2

201/2 201/2 201/2 201/2 201/2 21 21 21 21 21

16 16 20 20 20 24 24 24 28 28

141/4

17 /

1 2

141/4 171/2 21 171/2 21 241/2 21 241/2

HIGH EFFICIENCY COIL MODELS

VCG24TA2E VCG24TB2E VCG36TA2E VCG36TB2E VCG36TC2E VCG48TB2E VCG48TC2E VCG48TD2E VCG60TC2E VCG60TD2E

17 /

141/4 171/2 21 171/2 21 241/2 21 241/2

t

Liquid line: 3/8" ODS, suction line 3/4" ODS on 2 and 3 ton units, 7/8" ODS on 4 and 5 ton units.

52 54 67 69 71 82 85 88 91 95

1 2

For bottom duct opening dimensions, subtract 3/4" from width or depth. For top duct opening, subtract 1-1/2" from width or depth.

H

t

t

Do not use coils with polypropylene drain pans on oil furnaces or other applications where outlet temperatures exceed 300o F.

t

3

W

t

D

t

UNCASED COIL COIL MODELS

W = PAN WIDTH (nches)

D = PAN DEPTH (inches)

H = BARE SLAB HEIGHT (inches)

FITS FURNACE WIDTH (inches)

SHIPPING WEIGHT I(bs)

CCG24TA1E CCG24TB1E CCG36TA1E CCG36TB1E CCG36TC1E CCG48TB1E CCG48TC1E CCG48TD1E CCG60TC1E CCG60TD1E

13 16 13 16 191/2 16 191/2 23 191/2 23

193/8 193/8 193/8 193/8 193/8 193/8 193/8 193/8 193/8 193/8

12 12 16 16 16 20 20 20 24 24

141/4

27 29 36 38 40 45 48 51 54 57

13 16 14 16 191/2 16 191/2 23 191/2 23

193/8 193/8 193/8 193/8 193/8 193/8 193/8 193/8 213/4 213/4

14 14 18 18 18 22 22 22 26 26

141/4

17 /

1 2

141/4 171/2 21 171/2 21 241/2 21 241/2

HIGH EFFICIENCY COIL MODELS

CCG24TA2E CCG24TB2E CCG36TA2E CCG36TB2E CCG36TC2E CCG48TB2E CCG48TC2E CCG48TD2E CCG60TC2E CCG60TD2E

41 43 53 56 59 64 67 70 65 68

17 /

1 2

141/4 171/2 21 171/2 21 241/2 21 241/2

t

Do not use coils with polypropylene drain pans on oil furnaces or other applications where outlet temperatures exceed 300o F.

H

W

t

D

t

t

t

t

Liquid line: 3/8" ODS, suction line 3/4" ODS on 2 and 3 ton units, 7/8" ODS on 4 and 5 ton units.

Design, specifications, performance data and materials subject to change without notice.

:HOOZRUWK$YH-DFNVRQ0,‡3K‡ZZZKHDWFRQWUROOHUFRP



SP 4M 6/14

4



HC-COILS-D Rev. 04-2013