catalog Altech MotorDisconnectSwitches

Report 2 Downloads 31 Views
MOTOR DISCONNECT SWITCHES

FEATURES AND BENEFITS:

• One of the smallest 60A switches in the industry with compact design • Advanced switch technology (use of silver contacts ensures safe and durable operation) • Across the line, motor starting - up to 75hp/600V • General Use Rating - 25A to 150A/600V • Available as rotary switches for extended or direct handle • Toggle switches • Non-fused switch • Interrupting capacity 10kA with back-up fuse • DIN Rail and panel mount available • Comprehensive range of accessories includes Door Mounting Kits & Fuse Holder • Snap on auxiliary contacts • Enclosed switches with NEMA Type 4X rating • Operating temperature is -20°C to +40°C

UL508 Listed Manual Motor Controllers with Disconnecting Means E185115

AC Motor Across-The-Line AC General Use

EXTENDED / DIRECT HANDLE MOTOR DISCONNECT SWITCH KU/VKA switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5

EXTENDED / DIRECT HANDLE ACCESSORIES Extended Handle Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7 Direct Handle Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Door Mounting Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

TOGGLE HANDLE MOTOR DISCONNECT SWITCH KUE/EVA Switches and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11

ENCLOSED MOTOR DISCONNECT SWITCHES & FUSED ENCLOSED MOTOR DISCONNECT SWITCH (30A) KEM Switches and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-13 KKVM Fused Switch and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

STAINLESS STEEL ENCLOSED MOTOR DISCONNECT SWITCHES KER Switches and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15

APPLICATION EXAMPLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17

INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18

TERMS AND CONDITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

3

Extended/Direct Handle Motor Disconnect Switch The KU/VKA...N series can be used with extended and direct handles (see page 8-9 for details).

E185115

Catalog Number No. of Poles General Purpose Current Maximum Voltage Motor FLA @ 480V AC Motor FLA @ 600V AC Horsepower Rating /HP 110-120V AC 200V AC 208V AC 220-240V AC 265V AC 277V AC 380-415V AC 440-480V AC 550-600V AC

KU316N 3 (4 pole - KU416N) 16A 600V AC 14A 9A 1 Phase

3 Phase 1 Phase

3/4 2 2 2 2 2 3 5 3

1 1/2 3 3 3 3 3 7.5 10 7.5

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class:

KU340N 3 (4 pole - KU440N) 40A 600V AC 28A 18A

3 Phase 1 Phase

1 2 2 3 3 3 5 7.5 5

2 5 5 7.5 7.5 7.5 10 15 10

KU363N 3 (4 pole - KU463N) 60A 600V AC 34A 27A

3 Phase 1 Phase

2 3 3 5 5 5 7.5 10 7.5

3 7.5 7.5 10 10 10 15 20 15

3 Phase

3 5 5 5 5 7.5 10 15 15

5 10 10 10 10 10 20 25 25

10kA

10kA

10kA

10kA

50A 50A 80A 80A

50A 50A 80A 80A

50A 50A 80A 80A

60A 60A (80A@480V AC) 100A 100A

14-8AWG

14-8AWG

14-8AWG

12-4AWG

16 lb. in.

16 lb. in.

16 lb. in.

16 lb. in.

K5 RK5 RK1 J

Terminal Size Acceptability

KU325N 3 (4 pole - KU425N) 25A 600V AC 17.5A 11A

(Cu Conductors only, 75°C)

35 mm

58 mm

15 mm

65 mm 15.8 15.8 15.8 mm mm mm

58 mm

66 mm

15 mm

73 mm

66 mm

(to convert to inches multiply by 0.03937)

4 Pole 49.5 mm 15.8 15.8 mm mm

74 mm

73 mm

74 mm

3 Pole

Dimensions

35 mm

Terminal Torque

4 Pole

Weight

0.19Kg (0.419lb.) (3 pole) 0.23Kg (0.507lb.) (4 pole)

0.172Kg (0.379lb.) (3 pole) 0.172Kg (0.379lb.) (3 pole) 0.215Kg (0.474lb.) (4 pole) 0.215Kg (0.474lb.) (4 pole)

0.200Kg (0.441lb.) (3 pole) 0.245Kg (0.540lb.) (4 pole)

Suitable Accessories Extended Handle Version/ Door Interlock Mechanism Shaft L(1,2,3)00AD11-ST L(1,2,3)00AD11-ST L(1,2,3)00AD11-ST L(1,2,3)00AD11-ST Handles LK10 (Y/R) UL, LK11 (Y/R) U LK10 (Y/R) UL, LK11 (Y/R) U LK10 (Y/R) UL, LK11 (Y/R) U LK10 (Y/R) UL, LK11 (Y/R) U Auxiliary Switch KU1.V, KU2.V KU1.V, KU2.V KU1.V, KU2.V KU1.V, KU2.V Fuse Holder — — KV 10x38, KV 10x38 CC — Direct Handle Version Handle for 3 Pole K/KU3P (Y/R) K/KU3P (Y/R) K/KU3P (Y/R) K/KU3P (Y/R) Handle for 4 Pole K/KU4P (Y/R) K/KU4P (Y/R) K/KU4P (Y/R) K/KU4P (Y/R) Door Mounting Kits OKA/KU LK10 x; OKA x OKA/KU LK10 x; OKA x OKA/KU LK10 x; OKA x OKA/KU LK10 x; OKA x 4

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Extended/Direct Handle Motor Disconnect Switch The KU/VKA...N series can be used with extended and direct handles (see page 8-9 for details).

E185115

Catalog Number No. of Poles General Purpose Current Maximum Voltage Motor FLA @ 480V AC Motor FLA @ 600V AC

VKA380N 3 (4 pole - VKA480N) 80A 600V AC – 47A

VKA3100N 3 (4 pole - VKA4100N) 100A 600V AC – 54A

VKA3125N 3 (4 pole - VKA4125N) 125A 600V AC – 68A

VKA3160N 3 (4 pole - VKA4160N) 150A 600V AC – 83A

Horsepower Rating /HP

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

3 7.5 7.5 7.5 10 10 15 20 25

7.5 10 15 15 20 20 25 30 40

3 7.5 7.5 10 10 10 15 20 30

7.5 15 15 20 20 20 30 40 50

5 10 10 15 15 15 20 25 30

10 20 20 25 25 30 40 50 60

7.5 10 10 15 20 20 25 30 40

10 25 25 30 30 30 50 60 75

110-120V AC 200V AC 208V AC 220-240V AC 265V AC 277V AC 380-415V AC 440-480V AC 550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class: K5 RK5 RK1 J

Terminal Size Acceptability

10kA

10kA

10kA

10kA

150A 150A – 200A

150A 150A – 200A

150A 150A – 200A

150A 150A – 200A

4-1/0AWG

4-1/0AWG

4-1/0AWG

4-1/0AWG

50 lb. in.

50 lb. in.

(Cu Conductors only, 75°C)

50 lb. in. 3 Pole 15 mm

82 mm 67 mm 53 mm

79 mm 69 mm 20 mm

Weight

3

5

82 mm 67 mm 53 mm

2

99 mm 89 mm 20 mm

3

1

82 mm

35 mm

1

4 Pole

15 mm

5

7

35 mm

(to convert to inches multiply by 0.03937)

Ø4.5 mm

Dimensions

50 lb. in. 4 Pole

Ø4.5 mm 82 mm

Terminal Torque

2

6

4

6

8

0.480Kg (1.058lb.) (3 pole) 0.480Kg (1.058lb.) (3 pole) 0.480Kg (1.058lb.) (3 pole) 0.480Kg (1.058lb.) (3 pole) 0.620Kg (1.367lb.) (4 pole) 0.620Kg (1.367lb.) (4 pole) 0.620Kg (1.367lb.) (4 pole) 0.620Kg (1.367lb.) (4 pole)

Suitable Accessories Extended Handle Version/ Door Interlock Mechanism Shaft L(1,2.3)00AD11-ST Handles LK10(Y/R)UL,LK11(Y/R)U Auxiliary Switch VKA1.V,VKA2.V Fuse Holder – Direct Handle Version Handle for 3 & 4 Pole K/VKA3-4P (Y/R) Door Mounting Kits OKA/VKA x

L(1,2.3)00AD11-ST LK10(Y/R)UL,LK11(Y/R)U VKA1.V, VKA2.V –

L(1,2.3)00AD11-ST LK10(Y/R)UL,LK11(Y/R)U VKA1.V, VKA2.V –

L(1,2.3)00AD11-ST LK10(Y/R)UL,LK11(Y/R)U VKA1.V, VKA2.V –

K/VKA3-4P (Y/R)

K/VKA3-4P (Y/R)

K/VKA3-4P (Y/R)

OKA/VKA x

OKA/VKA x

OKA/VKA x

Dimensions (to convert to inches multiply by 0.03937) Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

5

DOOR INTERLOCK HANDLES with 3 padlock locations*

12 mm

Drill Template Included

63 mm

LK10 UL NEMA Type 4X, IP66 Black

DOOR INTERLOCK SHAFT

28.2 mm

78.5 mm

12.7 mm

Ø79 mm

3 mm

L100AD11-ST 100mm Steel

28.2 mm

LK10 Y/R UL NEMA Type 4X, IP66 Yellow/Red

L200AD11-ST 200mm Steel

SHAFT CUTTING RECOMMENDATIONS 1

cut to length

LK11 U NEMA Type 4X, IP67 Black

notch location & width

LK11 Y/R U NEMA Type 4X, IP67 Yellow/Red Leng

th

L300AD11-ST 300mm Steel

SHAFT LENGTH GUIDELINE LK10

LK11

Door Interlock Handle

Door Interlock Handle

22.5 mm

2

Ø4 mm

Ø22.5 mm

The steel shaft ensures reliable operation even in the toughest conditions. Cat. No. Length (L) Material

m 0m Ø4

Panel Drilling:

Ø22 mm

Cat. No. Environmental Rating Color

Drill Template Included

4 mm

38 mm

E185115 LK10 (Y/R) UL: • Single hole mounting (22.5mm) • Defeatable (built-in mechanism) LK11 (Y/R) U: • Retention mechanism (only rotates 90° from off to on, keeps handle in off position while cabinet door is open) • Defeatable (looses NEMA rating)

41 mm

Extended Handle Accessories

PZ0 1Nm Max

22.5 mm

PZ0 1Nm Max

~1 mm

8 mm

3

29 mm ±5

26 mm ± 1.5

file tip cut notch (optional)

4

final product

90°

Panel Door

Extended/Direct Handle Motor Disconnect Switch Door Interlock Handle Auxiliary Switch

*1/4” padlocks not included. 6

Door Interlock Shaft and Nut

Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

AUXILIARY SWITCHES

Extended Handle Accessories The auxiliary switches are the snap-on type and can be retrofitted.

Cat. No. Electrical Rating No. of contacts For Use With

KU1.V 10A/1/2HP/125-250V AC 1n.o./1n.c. KU models

FUSE HOLDER

KU2.V 10A/1/2HP/125-250V AC 2n.o./2n.c. KU models

VKA1.V 10A/1/2HP/125-250V AC 1n.o./1n.c. VKA models

VKA2.V 10A/1/2HP/125-250V AC 2n.o./2n.c. VKA models

This fuseholder can be retrofitted with the KU340N. Therefore design changes can be incorporated with ease to allow a fusible disconnect. Kit shown; comes with KU340N and fuse holder.

E185115

Cat. No. Electrical Rating Fuse Type For Use With Kit Includes

KKV 332 30A/600V AC 10x38, Midget – KV 10x38 / KU340N

KKV 332CC 30A/600V AC Class CC – KV 10x38 CC / KU340N

58 mm

KV 10x38 CC 30A/600V AC Class CC KU340N –

71 mm

74 mm

74 mm Kit shown; comes with switch and fuse holder.

KV 10x38 30A/600V AC 10x38, Midget KU340N –

50 mm

58 mm

70 mm

74 mm

56 mm

50 mm 60 mm

CHANGE-OVER KITS

• For 2 KU switches • Available with black or yellow/red handle (Y/R) Cat. No. Color

KU3/4P VV Black

Cat. No. Color

KU3/4P VV Y/R Yellow/Red

60 mm Ø4.2 mm

125 mm

125 mm

79 mm

74 mm

32 mm 56 mm 56 mm

PARALLEL KITS

59 mm

50 mm 60 mm

• For KU and VKA-switches • Assembly depth for KU 155-300 mm • Assembly depth for VKA 164-310 mm 75-220

L

93 mm

Center pivoting model available, contact Altech.

65.5 mm 45 mm

134 mm

7 mm

38 mm

48 mm

Cat. No. RV 66S-ST RV 80S-ST RV 104S-ST

Length (L)

For use with

66 mm 80 mm 104 mm

2x KU 3 pole (3P) 2x KU 4P/VKA 3P 2x VKA 4P

Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

7

Direct Handle Accessories and Mounting Alternatives DIRECT HANDLES Improved design with metal shaft. Use for all your “inside the panel” applications. 1 suitcase lock location.

81 mm 52 mm

Cat. No. Color For use with

K/KU3P Black KU models (3P)

36 mm

74 mm

45 mm 66 mm

45 mm

K/KU3P Y/R Yellow/Red KU models (3P) 81 mm 70 mm

K/KU4P Y/R Yellow/Red KU models (4P)

Cat. No. Color For use with

K/VKA3-4P Black VKA models (3/4P)

K/VKA3-4P Y/R Yellow/Red VKA models (3/4P)

3 Pole

105 mm

36 mm

74 mm

K/KU4P Black KU models (4P)

45 mm 66 mm

Cat. No. Color For use with

45 mm

4 Pole 66 mm

66 mm

43 mm

0

43 mm

82 mm

45 mm

1

60 mm

60 mm

73 mm

73 mm

ALUMINUM DIN RAIL

95 mm

95 mm

Panel mount option for small Disconnect Switches. 14 mm

66 mm

27 mm

1 mm

4 mm

27 mm

RKA 4P KU425/40/63N

RKA 4P

4 mm

NOTE:

RKA 3P KU325/40/63N

1 mm

35 mm

Cat. No. For Use With

14 mm

35 mm

RKA 3P

7.5 mm

84 mm

7.5 mm

In the rare case that your mounting hardware (screws) for DIN Rail interfere with the enforcement studs in the back of the Motor Disconnect Switch please use smaller (≤M3 or equivalent) flathead screws or change your DIN Rail to the 15mm high version.

Dimensions (to convert to inches multiply by 0.03937) 8

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Door Mounting Kits Designed for fast and easy assembly.

OKA/KU LK10 Series Environmental ratings: NEMA Type 4X, IP66; 3 padlock locations*. 72 mm

38 mm

Ø79 mm

Drill Template Included

E185115

Shown with switch and display plate. (sold separately)

Cat. No. (Black Handle) OKA/KU LK10 OKA/KU LK10 1.V OKA/KU LK10 2.V OKA/KU4P LK10 OKA/KU4P LK10 1.V OKA/KU4P LK10 2.V

Cat. No. (Yellow/Red Handle) OKA/KU LK10 Y/R OKA/KU LK10 1.V Y/R OKA/KU LK10 2.V Y/R OKA/KU4P LK10 Y/R OKA/KU4P LK10 1.V Y/R OKA/KU4P LK10 2.V Y/R

No. of aux. switches 0 1 2 0 1 2

For use with 3 Pole KU switch 3 Pole KU switch 3 Pole KU switch 4 Pole KU switch 4 Pole KU switch 4 Pole KU switch

OKA Series Environmental ratings: IP65; 3 padlock locations*. 72 mm

32 mm

70 mm

66 mm

62 mm

62 mm

Drill Template Included

Shown with switch and display plate. (sold separately)

Cat. No. (Black Handle) OKA 0.V OKA 1.V OKA 2.V

Cat. No. (Yellow/Red Handle) OKA 0.V Y/R OKA 1.V Y/R OKA 2.V Y/R

No. of aux. switches 0 1 2

For use with 3 Pole KU switch 3 Pole KU switch 3 Pole KU switch

OKA/VKA Series Environmental ratings: NEMA Type 4X, IP67; 3 padlock locations*. 87mm

63mm

41mm

E185115

Shown with switch. (sold separately)

Cat. No. (Black Handle) OKA/VKA 0.V OKA/VKA 1.V OKA/VKA 2.V OKA/VKA4P 0.V OKA/VKA4P 1.V OKA/VKA4P 2.V

*1/4” padlocks not included.

OFF

82mm

78.7mm

ON

Drill Template Included

Cat. No. (Yellow/Red Handle) OKA/VKA 0.V Y/R OKA/VKA 1.V Y/R OKA/VKA 2.V Y/R OKA/VKA4P 0.V Y/R OKA/VKA4P 1.V Y/R OKA/VKA4P 2.V Y/R

No. of aux. switches 0 1 2 0 1 2

For use with 3 Pole VKA switch 3 Pole VKA switch 3 Pole VKA switch 4 Pole VKA switch 4 Pole VKA switch 4 Pole VKA switch

Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

9

Toggle Handle Motor Disconnect Switch The KUE series only requires an additional cover plate (see below) which makes the switch IP20 touch proof.

E185115

Catalog Number No. of Poles General Purpose Current Maximum Voltage Motor FLA @ 480V AC Motor FLA @ 600V AC Horsepower Rating /HP 110-120V AC 200V AC 208V AC 220-240V AC 265V AC 277V AC 380-415V AC 440-480V AC 550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class: K5 RK5 RK1 J

Terminal Size Acceptability

KUE316 3 16A 600V AC 14A 9A

KUE325 3 25A 600V AC 17.5A 11A

KUE340 3 40A 600V AC 28A 18A

KUE363 3 60A 600V AC 34A 27A

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

3/4 2 2 2 2 2 3 5 3

1 1/2 3 3 3 3 3 7.5 10 7.5

1 2 2 3 3 3 5 7.5 5

2 5 5 7.5 7.5 7.5 10 15 10

2 3 3 5 5 5 7.5 10 7.5

3 7.5 7.5 10 10 10 15 20 15

3 5 5 5 5 7.5 10 15 15

5 10 10 10 10 10 20 25 25

10kA

10kA

10kA

10kA

50A 50A 80A 80A

50A 50A 80A 80A

50A 50A 80A 80A

60A 60A (80A@480V AC) 100A 100A

14-8AWG

14-8AWG

14-8AWG

12-4AWG

16 lb. in.

16 lb. in.

16 lb. in.

16 lb. in.

(Cu Conductors only, 75°C)

Terminal Torque

50.5 mm

71 mm

Dimensions (to convert to inches multiply by 0.03937)

1L1

74 mm

1L1

1L1

Weight

0.19Kg (0.419lb.)

1L1

1L1

0.172Kg (0.379lb.)

0.172Kg (0.379lb.)

0.200Kg (0.441lb.)

Suitable Accessories Cover Plate

Cat. No. Color Shape

K/KUE Grey Rectangular

K/KUE Y Yellow Rectangular

R/KUE Grey Circular

R/KUE Y Yellow Circular

Dimensions (to convert to inches multiply by 0.03937) 10

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Toggle Handle Motor Disconnect Switch The EVA series includes a cover plate.

E185115

Catalog Number White Cover/ White Handle Yellow Cover/ Red Handle No. of Poles General Purpose Current Maximum Voltage Motor FLA @ 480V AC Motor FLA @ 600V AC

EVA380 + K/EVA EVA380 + K/EVA Y/R 3 80A 600V AC — 47A

EVA3100 + K/EVA EVA3100 + K/EVA Y/R 3 100A 600V AC – 54A

Horsepower Rating /HP

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

3 7.5 7.5 7.5 10 10 15 20 25

7.5 10 15 15 20 20 25 30 40

3 7.5 7.5 10 10 10 15 20 30

7.5 15 15 20 20 20 30 40 50

5 10 10 15 15 15 20 25 30

10 20 20 25 25 30 40 50 60

7.5 10 10 15 20 20 25 30 40

10 25 25 30 30 30 50 60 75

110-120V AC 200V AC 208V AC 220-240V AC 265V AC 277V AC 380-415V AC 440-480V AC 550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class: K5 RK5 RK1 J

Terminal Size Acceptability

EVA3125 + K/EVA EVA3125 + K/EVA Y/R 3 125A 600V AC – 68A

EVA3160 + K/EVA EVA3160 + K/EVA Y/R 3 150A 600V AC – 83A

10kA

10kA

10kA

10kA

150A 150A — 200A

150A 150A – 200A

150A 150A – 200A

150A 150A – 200A

4-1/0AWG

4-1/0AWG

4-1/0AWG

4-1/0AWG

50 lb. in.

50 lb. in.

50 lb. in.

50 lb. in.

(Cu Conductors only, 75°C)

Terminal Torque

Dimensions

78 mm 53 mm 47 mm

79 mm 69 mm

(to convert to inches

4.5 mm

35 mm

82 mm

multiply by 0.03937)

Weight

0.480Kg (1.058lb.) (3 pole) 0.480Kg (1.058lb.) (3 pole) 0.480Kg (1.058lb.) (3 pole) 0.480Kg (1.058lb.) (3 pole)

Special Black Toggle Handle Motor Disconnect Switch EVA3100 + K/EVAB

Dimensions (to convert to inches multiply by 0.03937) Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

11

Enclosed Motor Disconnect Switch

*

These enclosed switches can be used locally at the motor.

E185115

Catalog Number Black Handle Yellow/ Red Handle No. of Poles General Purpose Current Maximum Voltage Motor FLA @ 480V AC Motor FLA @ 600V AC Horsepower Rating /HP 110-120V AC 200V AC 208V AC 220-240V AC 265V AC 277V AC 380-415V AC 440-480V AC 550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class: K5 RK5 RK1 J

Terminal Size Acceptability

KEM325UL KEM325UL Y/R 3 (4 pole - KEM425UL Y/R) 25A 600V AC 17.5A 11A

KEM340UL KEM340UL Y/R 3 (4 pole - KEM440UL Y/R) 40A 600V AC 28A 18A

KEM360UL KEM360UL Y/R 3 (4 pole - KEM460UL Y/R) 60A 600V AC 34A 27A

KEM380UL KEM380UL Y/R 3 (4 pole - KEM480UL Y/R) 80A 600V AC – 47A

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

1 2 2 3 3 3 5 7.5 5

2 5 5 7.5 7.5 7.5 10 15 10

2 3 3 5 5 5 7.5 10 7.5

3 7.5 7.5 10 10 10 15 20 15

3 5 5 5 5 7.5 10 15 15

5 10 10 10 10 10 20 25 25

3 7.5 7.5 7.5 10 10 15 20 25

7.5 10 15 15 20 20 25 30 40

10kA

10kA

10kA

50A 50A 80A 80A

50A 50A 80A 80A

14-8AWG

14-8AWG

10kA

60A 60A (80A@480V AC) 100A 100A

150A 150A — 200A

12-4AWG

4-1/0AWG

(Cu Conductors only, 75°C) 16 lb. in. NEMA Type 4X U2

16 lb. in. NEMA Type 4X U3

16 lb. in. NEMA Type 4X U3

Ø20 Accesos (opcionales) Ø25/32

U2

Dimensions Accesos (opcionales) Ø20/25

(to convert to inches multiply by 0.03937)

0.49kg (1.08 lb.)

Suitable Accessories Auxiliary Contacts

KU1.V, KU2.V

*16A model also available, please contact Altech. 12

0.72kg (1.587 lb.)

KU1.V, KU2.V

0.773kg (1.698 lb.)

KU1.V, KU2.V

U3

131 mm 96 mm

144 mm 132 mm

178 mm

106 mm

118 mm 130.4 mm

96.4 mm 84 mm

Weight

50 lb. in. NEMA Type 4X U3

190 mm

Terminal Torque Environmental Rating Enclosure Type Used

1.021kg (2.249 lb.)

VKA1.V,VKA2.V

Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Enclosed Motor Disconnect Switch

FUSED

KEM3100L KEM3100L Y/R 3 (4 pole - KEM4100L Y/R) 100A 600V AC – 54A

KEM3125L KEM3125L Y/R 3 (4 pole - KEM4125L Y/R) 125A 600V AC – 68A

KEM3150L KEM3150L Y/R 3 (4 pole - KEM4150L Y/R) 150A 600V AC – 83A

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

3 7.5 7.5 10 10 10 15 20 30

7.5 15 15 20 20 20 30 40 50

5 10 10 15 15 15 20 30 30

10 20 20 25 25 30 40 50 60

7.5 10 10 15 20 20 25 30 40

10 25 25 30 30 30 50 60 75

KKVM332, KKVM332CC KKVM332 Y/R, KKVM332CC Y/R 3 30A 600V AC

Cat. No.

Fuse Type

KKVM 332 (Y/R)

10x38, Midget

KKVM 332CC (Y/R)

Class CC

10kA

10kA

10kA

150A 150A – 200A

150A 150A – 200A

150A 150A – 200A

50A 50A 80A 80A

4-1/0AWG

4-1/0AWG

4-1/0AWG

14-8AWG

50 lb. in. NEMA Type 4X MF10

50 lb. in. NEMA Type 4X MF10

50 lb. in. NEMA Type 4X MF11UL

16 lb. in. NEMA Type 4X U3

MF11UL

130 mm

172 mm

MF10

172 mm

10kA

Ø20 KNOCK-OUTS Ø25/32

U3

273 mm 278 mm 254 mm

VKA1.V,VKA2.V

1.9051kg (4.2 lb.)

VKA1.V,VKA2.V

2.8351kg (6.25 lb.)

VKA1.V,VKA2.V

178 mm 190 mm

354 mm

378 mm

273 mm

278 mm

1.9051kg (4.2 lb.)

131 mm 96 mm

144 mm 132 mm

373 mm

183 mm 188 mm

0.998kg (2.2 lb.)

KU1.V, KU2.V Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

13

Stainless Steel Enclosed Motor Disconnect Switch

*

These enclosures are ideal where chemicals are used for cleaning and maintenance such as food processing plants and breweries. Mining is another application area. Their stainless steel construction is extremely resistant to corrosion, and the enclosure is also rated to IP66. Catalog Number Black Handle Yellow/ Red Handle No. of Poles General Purpose Current Maximum Voltage Motor FLA @ 480V AC Motor FLA @ 600V AC Horsepower Rating /HP

E185115

KER325UL KER325UL Y/R 3 (4 pole - KER425UL Y/R) 25A 600V AC 17.5A 11A

KER340UL KER340UL Y/R 3 (4 pole - KER440UL Y/R) 40A 600V AC 28A 18A

1 Phase

3 Phase

1 Phase

3 Phase

1 2 2 3 3 3 5 7.5 5

2 5 5 7.5 7.5 7.5 10 15 10

2 3 3 5 5 5 7.5 10 7.5

3 7.5 7.5 10 10 10 15 20 15

110-120V AC 200V AC 208V AC 220-240V AC 265V AC 277V AC 380-415V AC 440-480V AC 550-600V AC

Short Circuit Withstand Rating at 600 V with Max. Fuse Size/Class: K5 RK5 RK1 J

Terminal Size Acceptability

10kA

10kA

50A 50A 80A 80A

50A 50A 80A 80A

14-8AWG

14-8AWG

(Cu Conductors only, 75°C)

Terminal Torque Environmental Rating Enclosure Type Used

16 lb. in.

16 lb. in.

NEMA Type 4X

NEMA Type 4X

H23

H23 120 mm

Dimensions

H23

(to convert to inches multiply by 0.03937) 108 mm 99 mm

73 mm

Suitable Accessories Auxiliary Contacts * 16A model also available, please contact Altech. 14

OFF

180 mm

Weight

160 mm

ON

1.35kg (2.98 lb.)

1.35kg (2.98 lb.)

KU1.V, KU2.V

KU1.V, KU2.V Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Stainless Steel Enclosed Motor Disconnect Switch

E185115

KER360UL KER360UL Y/R 3 (4 pole - KER460UL Y/R) 60A 600V AC 34A 27A

KER380UL KER380UL Y/R 3 (4 pole - KER480UL Y/R) 80A 600V AC – 47A

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

1 Phase

3 Phase

3 5 5 5 5 7.5 10 15 15

5 10 10 10 10 10 20 25 25

3 7.5 7.5 7.5 10 10 15 20 25

7.5 10 15 15 20 20 25 30 40

3 7.5 7.5 10 10 10 15 20 30

7.5 15 15 20 20 20 30 40 50

5 10 10 15 15 15 20 30 30

10 20 20 25 25 30 40 50 60

KER3100UL KER3100UL Y/R 3 (4 pole - KER4100UL Y/R) 100A 600V AC – 54A

KER3125UL KER3125UL Y/R 3 (4 pole - KER4125UL Y/R) 125A 600V AC – 68A

10kA

10kA

10kA

10kA

60A 60A (80A@480V AC) 100A 100A

150A 150A — 200A

150A 150A – 200A

150A 150A – 200A

12-4AWG

4-1/0AWG

4-1/0AWG

4-1/0AWG

16 lb. in.

50 lb. in.

50 lb. in.

50 lb. in.

NEMA Type 4X

NEMA Type 4X

NEMA Type 4X

NEMA Type 4X

H32

H32

H32

H32

160 mm

H32

125 mm 90 mm

ON

OFF

280 mm

260 mm

139 mm

2.66kg (5.87 lb.)

2.66kg (5.87 lb.)

2.66kg (5.87 lb.)

2.66kg (5.87 lb.)

KU1.V, KU2.V

VKA1.V,VKA2.V

VKA1.V,VKA2.V

VKA1.V,VKA2.V Dimensions (to convert to inches multiply by 0.03937)

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

15

Motor Disconnect Switch Applications Motor Disconnect switches, enclosures and accessories are used in a variety of applications such as conveyors, powder packaging machines, bucket type conveyors and other various automation machinery.

KUHL Corporation is a world-class manufacturer and provider of poultry and specialty equipment worldwide. Kuhl uses Altech Motor Disconnect Switches and other Altech Control components to help their equipment perform at its best.

16

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

Motor Disconnect Switch Applications

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com

17

Motor Disconnect Switch Index Part No.

Page

EVA3100 + K/EVA ..................................................11 EVA3100 + K/EVA Y/R ...........................................11 EVA3100 + K/EVAB................................................11 EVA3125 + K/EVA ..................................................11 EVA3125 + K/EVA Y/R ...........................................11 EVA3160 + K/EVA ..................................................11 EVA3160 + K/EVA Y/R ...........................................11 EVA380 + K/EVA ....................................................11 EVA380 + K/EVA Y/R .............................................11 K/KU3P ....................................................................8 K/KU3P Y/R .............................................................8 K/KU4P ....................................................................8 K/KU4P Y/R .............................................................8 K/KUE ....................................................................10 K/KUE Y .................................................................10 K/VKA3-4P ...............................................................8 K/VKA3-4P Y/R ........................................................8 KEM3100L .............................................................13 KEM3100L Y/R.......................................................13 KEM3125L .............................................................13 KEM3125L Y/R.......................................................13 KEM3150L .............................................................13 KEM3150L Y/R.......................................................13 KEM325UL .............................................................12 KEM325UL Y/R ......................................................12 KEM340UL .............................................................12 KEM340UL Y/R ......................................................12 KEM360UL .............................................................12 KEM360UL Y/R ......................................................12 KEM380UL .............................................................12 KEM380UL Y/R ......................................................12 KER3100UL ...........................................................15 KER3100UL Y/R ....................................................15 KER3125UL ...........................................................15 KER3125UL Y/R ....................................................15 KER325UL .............................................................14 KER325UL Y/R ......................................................14 KER340UL .............................................................14 KER340UL Y/R ......................................................14 KER360UL .............................................................15 KER360UL Y/R ......................................................15 KER380UL .............................................................15 KER380UL Y/R ......................................................15 KKV 332 ...................................................................7 KKV 332CC..............................................................7 KKVM332 ...............................................................13 KKVM332 Y/R ........................................................13 KKVM332CC ..........................................................13 KKVM332CC Y/R...................................................13 KU1.V .......................................................................7 KU2.V .......................................................................7 KU3/4P VV ...............................................................7 KU3/4P VV Y/R ........................................................7 KU316N....................................................................4 KU325N....................................................................4 KU340N....................................................................4 KU363N....................................................................4 KU416N....................................................................4 KU425N....................................................................4 KU440N....................................................................4 KU463N....................................................................4 KUE316 ..................................................................10 18

Part No.

Page

KUE325 ..................................................................10 KUE340 ..................................................................10 KUE363 ..................................................................10 KV 10x38..................................................................7 KV 10x38 CC ...........................................................7 L100AD11-ST...........................................................6 L200AD11-ST...........................................................6 L300AD11-ST...........................................................6 LK10 UL ...................................................................6 LK10 Y/R UL ............................................................6 LK11 U .....................................................................6 LK11 Y/R U ..............................................................6 OKA 0.V ...................................................................9 OKA 0.V Y/R ............................................................9 OKA 1.V ...................................................................9 OKA 1.V Y/R ............................................................9 OKA 2.V ...................................................................9 OKA 2.V Y/R ............................................................9 OKA/KU LK10 ..........................................................9 OKA/KU LK10 1.V....................................................9 OKA/KU LK10 1.V Y/R.............................................9 OKA/KU LK10 2.V....................................................9 OKA/KU LK10 2.V Y/R.............................................9 OKA/KU LK10 Y/R ...................................................9 OKA/KU4P LK10......................................................9 OKA/KU4P LK10 1.V ...............................................9 OKA/KU4P LK10 1.V Y/R ........................................9 OKA/KU4P LK10 2.V ...............................................9 OKA/KU4P LK10 2.V Y/R ........................................9 OKA/KU4P LK10 Y/R...............................................9 OKA/VKA 0.V ...........................................................9 OKA/VKA 0.V Y/R ....................................................9 OKA/VKA 1.V ...........................................................9 OKA/VKA 1.V Y/R ....................................................9 OKA/VKA 2.V ...........................................................9 OKA/VKA 2.V Y/R ....................................................9 OKA/VKA4P 2.V......................................................9 OKA/VKA4P 0.V.......................................................9 OKA/VKA4P 0.V Y/R................................................9 OKA/VKA4P 1.V.......................................................9 OKA/VKA4P 1.V Y/R................................................9 OKA/VKA4P 2.V Y/R................................................9 R/KUE ....................................................................10 R/KUE Y.................................................................10 RKA 3P.....................................................................8 RKA 4P.....................................................................8 RV 104S-ST .............................................................7 RV 66S-ST ...............................................................7 RV 80S-ST ...............................................................7 VKA1.V.....................................................................7 VKA2.V.....................................................................7 VKA3100N ...............................................................5 VKA3125N ...............................................................5 VKA3160N ...............................................................5 VKA380N .................................................................5 VKA4100N ...............................................................5 VKA4125N ...............................................................5 VKA4160N ...............................................................5 VKA480N .................................................................5

Altech Corp.® • 35 Royal Road • Flemington, NJ 08822-6000 • Phone (908)806-9400 • FAX (908)806-9490 • www.altechcorp.com