LC247HV CeilingCassetteSingleZone OutdoorUnit(ODU)ͲLUU247HV IndoorUnit(IDU)ͲLCN247HV Performance: CoolingCapacity(Btu/h) HeatingCapacity(Btu/h) SEER EER HSPF

24,000 27,000 17 12.56 9.7

OperatingRange: OutdoorUnit: Cooling(°FDB) Heating(°FWB)

5Ͳ118 0Ͳ64

IndoorUnit: Cooling(°FDB) Heating(°FDB)

SEERͲSeasonalEnergyEfficiencyRatioEERͲEnergyEfficiencyRatio HSPFͲHeatingSeasonalPerformanceFactor

Electrical: OutdoorUnit:

64Ͳ90 60Ͳ77

UnitData: RefrigerantType RefrigerantControl IDUSoundPressure(H/M/L)±3dB(A)Ϻ ODUSoundPressureMax(Cool/Heat)±3dB(A)Ϻ

R410A EEV 38/36/34 48/52

PowerSupply(V¹/Hz/Ø) MOP(A) MCA(A) CoolingRatedAmps(A)

208Ͳ230/60/1 30 18.1 12.2

HeatingRatedAmps(A) Compressor(A)

16.0 13.5

ODUNetUnitWeight(lbs)

133

ODUShippingWeight(lbs)

146

0.6

MOPͲMaximumOvercurrentProtection MCAͲMinimumCircuitAmpacity

IDUNetUnitWeight IDUShippingWeight(lbs)

46 58

IndoorUnit:

GrilleWeight(lbs)

11

GrilleShippingWeight(lbs)

20

Fan(A)

PowerSupply(V¹/Hz/Ø) CoolingPowerInput(kW) HeatingPowerInput(kW)

208Ͳ230/60/1 1.91 2.60

FanType

Piping:

Turbo 600/530/459

AirCirculation(CFMH/M/L)

RefrigerantCharge(lbs) LiquidLine(in,OD)

4.41 3/8

SuctionLine(in,OD)

5/8

MaxPipeLength(ft)¹ MaxElevation(ft)

164 98

Features: ••Inverter(Variablespeed compressor) ••Internalcondensatepump ••SwirlWind ••JetCool ••Independentvanecontrol ••Evaporatorfrostcontrol

Fan:

••Autorestart ••Autochangeover ••UltraͲquietturbofan ••BuiltͲinlowambientstandard, downto5Ԭ(coolingmode) ••NightquietoperaƟon

IncludedAccessories:

4/5/4

FanSpeeds(Fan/Cooling/Heating)

5.1

Dehumidification(pts/hr)

StandardFeatures: ••LimitedSevenYearCompressorWarranty ••LimitedFiveYearFuncƟonalPartsWarranty

Notes: 1.AcceptableoperaƟngvoltage:187VͲ253V. 2.Pipinglengthsareequivalent. 3.MustcomplywithapplicablecodesforreisolaƟondampers. 4.SoundpressurelevelsaretestedinananechoicchamberunderISOStandard1996. 5.AllcommunicaƟoncabletobeminimum18Americanwiregage(AWG),2Ͳconductor, stranded,shieldedandmustcomplywithapplicablelocalandnationalcode. 6.Thisunitcomeswithadryheliumcharge. 7.Nominaldataisrated0Ōabovesealevel,with25Ōofrefrigerantlineanda0Ōlevel differencebetweenoutdoorandindoorunits. 8.PowerwiringcablesizemustcomplywiththeapplicablelocalandnaƟonalcode. 9.MustfollowinstallaƟoninstrucƟonsintheapplicableLGinstallaƟonmanual.

••7ͲDayProgrammableController(White)ͲPQRCVSL0QW

RequiredAccessories(soldseparately) CassetteGrille(PTͲUMC)

OptionalAccessories(soldseparately): WirelessHandheldRemoteController––PQWRHDF0 PlasmaKitͲPTPKM0 Ventilation³KitͲPTVK410+PTVK420 AutoElevationKitͲPTEGM0 PI485ͲPMNFP14A0 Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice. LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.““LGLife’’sGood””isaregisteredtrademarkofLGCorp./www.lghvac.com

DFSͲSBͲACͲ004ͲUS012K18

Page1of3

JobName/Location:

OutdoorUnit(ODU)ͲLUU247HV CeilingCassetteSingleZone

Tag#: Date: PONo.:

Forcontinualproductdevelopment,LGreservestherighttochangespecificationswithoutnotice. LGElectronicsU.S.A.,Inc.,EnglewoodCliffs,NJ.Allrightsreserved.““LGLife’’sGood””isaregisteredtrademarkofLGCorp./www.lghvac.com