If drilling & screw insertion is not required, the wound can be closed anytime after 10 minutes
CERAMENT™ |BONE VOID FILLER Mixing chart
MIX
0
a)
WAIT
30s
INJECT
3 min
WAIT
5 min
MOLD
7 min
DRILLING & SCREW INSERTION
WAIT
9 min
~15 min
a)
b)
b)
WWW.BONESUPPORT.COM PR 0242-03 EN/US
a) Remove plug from large powder syringe b) Attach valve, clear end to the large powder syringe
Mix for 30 seconds
a) Unscrew plug of liquid filled syringe using provided tool embedded in blister b) Attach liquid syringe to valve (blue end)
Empty liquid into large powder syringe
Remove red plunger stop
Fully retract blue handle and turn blue knob clockwise
Transfer paste into empty delivery syringe
Remove red plunger stop. Wait 3 minutes before injecting from the syringe. Refer to time chart above for further options