Characterization of

Report 3 Downloads 82 Views
Characterization of

H2S-Induced Concrete Corrosion Using Established and New Methods

Scott Schaefer, PE Co-authors: M. Schaefer, M. Massey, V. Schaefer, and S. Fendorf WEFTEC 2016 Presented by: Advanced Engineering and Environmental Services, Inc. (AE2S)

Study Overview

Samples from six municipalities, four states Elemental analyses and traditional methods Observed corrosion penetration and corrosion product formation Best samples: 3.5-km interceptor with abrupt H2S (> 1,000 ppm) from a new SIU FRP insert rehabilitation

H2S CORROSION FUNDAMENTALS SAMPLING & TESTING METHODS STUDY RESULTS CONCLUSIONS

H2S Corrosion

FUNDAMENTALS

FUNDAMENTALS – SOURCES OF H2S H2S CORROSION FUNDAMENTALS

Regional Water Supplies High in Sulfate Significant Industrial User (SIU) Discharges • • •

Sulfate Sulfides Low pH and/or high strength organics/TKN

Water Conservation / I&I reduction •

Less water = longer retention time = anaerobic

Regionalization •

Longer collection systems = longer retention time = anaerobic

The Sewer Sulfur Cycle H2S CORROSION FUNDAMENTALS

Reference: WERF, 2007

FUNDAMENTALS RECAP H2S CORROSION FUNDAMENTALS

Corrosion Due to Acid Attack • •

Sulfuric acid formation Attacks – Concrete (simplified attack) H2SO4 + CaCO3 (concrete) = H2CO3 + CaSO4 (gypsum) – Metals

Sampling & Testing

METHODS

INDUSTRIAL IMPACTS TRADITIONAL SAMPLING/TESTING SAMPLING & TESTING METHODS

Problem •

Industrial Discharge with high H2S (100s to >1,000 ppm measured)



Rapid corrosion of 64 downgradient concrete manholes by acid attack



¼’ to ½’ concrete lost in ~2 months



Phenolphthalein staining confirmation

Interior Concrete Being Scraped

TRADITIONAL SAMPLING/TESTING SAMPLING & TESTING METHODS

75 mm (3”) diameter core samples from manholes Rebound hammer field tests: Manhole structural integrity Cores split and phenolphthalein stain tested: acid penetration H2S Measurement Multi-gas safety meters (spot check) OdaLog units (continuous)

Five additional communities sampled

TOOLS

SAMPLING & TESTING METHODS

SAMPLING & TESTING METHODS

4-GAS METER

ODALOGGER

REBOUND HAMMER

TOOLS

SAMPLING & TESTING METHODS

SAMPLING & TESTING METHODS

CORE DRILL

CORE PLUG

FISHING NET

ELEMENTAL COMP TESTING SAMPLING & TESTING METHODS

Total elemental composition by x-ray fluorescence (XRF), hand-held Bruker S1 Titan-LE unit interior face exterior face 3 cm from interior face

Comparison samples ground to fine powder and analyzed by bulk XRF (Spectro XEPOS).

ELEMENTAL COMP XRD & XAS TESTING SAMPLING & TESTING METHODS

Bulk sulfur x-ray absorption spectroscopy (XAS) performed at Beamline 4-3 at the Stanford Synchrotron Radiation Lightsource (SSRL) . X-ray microprobe imaging and spectroscopy at Beamlines 14-3 and 10-2.

Study

RESULTS

INDUSTRIAL IMPACTS STUDY RESULTS

Phenolphthalein staining

INDUSTRIAL IMPACTS STUDY RESULTS

Sewer Sample Locations, H2S Conc., & Elemental Ca & S Abundance Measurements

Sample Location Upstream Mixing Manhole Downstream 1 Downstream 1 Downstream 1 Downstream 2 Downstream 3 Downstream 4 Downstream 5

Sampling H2S Average Depth (ft) (ppm) 6 7 3.5 6.5 10.5 6.5 3.5 8 3.5

H2S Maximum (ppm)

Not Determined

Not Determined

183 711 711 711 106

835 >1,000 >1,000 >1,000 130

Not Determined

Not Determined

Not Determined

Not Determined

61

163

Calcium Sulfur (%) (%) 21.27 7.78 3.62 9.96 5.52 10.31 11.57 6.30 11.90

0.22 10.30 5.65 14.06 8.23 3.49 14.65 26.37 15.74

Ca:S 96.68 0.72 0.64 0.71 0.62 5.33 0.79 0.36 0.74

INDUSTRIAL IMPACTS STUDY RESULTS

Sulfur Bulk Abundance by XRF Higher on interior surface vs exterior surface for all samples except upstream control MH Upstream Control Mixing Manhole Closest Downstream Manhole Further Downstream Manholes

25 20 15 10 5

Distance from Interior of Manhole [cm]

20

15

10

5

0

0

S u lfu r A b u n d a n c e [% ]



MUNICIPAL CONCRETE SAMPLES STUDY RESULTS

Sulfur Bulk Abundance & Ca:S Ratio Measurements (Proxy for extent of sulfide/sulfate corrosion of concrete) Various Lower H2S Concentrations and Time Exposures

Sample ID MCS1 MCS2 MCS3 MCS4 MCS5 MCS6

Calcium (%) 3.53 13.90 0.69 14.67 3.25 7.99

Sulfur (%) 2.75 25.81 0.83 14.19 9.67 7.40

Ca:S 1.03 0.43 0.67 0.83 0.27 0.86

CALCIUM:SULFUR RATIO INTERPRETATION STUDY RESULTS

Ca:S Ratio

Interpretation

>1

High Ca, less corrosion

=1

Stoichiometric gypsum ratio (main corrosion product, Mori et al. 1992)