R-Series Lids The Christy brand R-Series lid is the perfect solution for parkway, sidewalk and greenbelt enclosure applications. This reinforced lid and ring are available with bolt down and AMR capabilities.
Patented Protection
Conventional Concrete • Substantial increase in strength and durability • Protects against chipping and cracking • Ensures consistent dimensions • UV Inhibitor ensures long life • New marking plate provides FAST turnaround for custom markings
Cross Reference Guide Water Meter Boxes BES C30 Merter Box C30D C30P C30E C30G C30GP No Equal C30-61D C30-61P C30-61G C30-61GP C30X12 C30SL C36 Meter Box C36D C36P C36E C36G C36GP No Equal C36-61D C36-61P C36-61G C36-61GP C36X12 C36SL C40 Meter Box C40D C40P C40M C40-61D C40-61P C40-61G
Brooks #38 Meter Box #38 1 piece #38 S #38 H #38 T #38 TR #38 Ext. #38 Slab #66 Meter Box #66 1 piece #66 S #66 H #66 T #66 TR #66 Ext. #66 Slab #67 Meter Box #67 1 piece #67 S #67 T #67 TR Cross Reference Guide
Installation in Concrete or Pavement for driveways, parking lots and off-roadway applications where subject to occasional non-deliberate light vehicles. ASPHALT PAVEMENT OR CONCRETE
8"
CONCRETE COLLAR AROUND BOX
Meter Box or Pull Box with Cover Gravel Base (Approx. 3" to 6")
COMPACTED FILL
FIELD PREPARATION Prepare the excavation approximately 6" deeper than the overall height of the enclosure. The length and width of the excavation should be determined by adding 4" to 6" to the overall length and width of the box.
INSTALLATION RECOMMENDATIONS
CONCRETE COLLAR
Placement of approximately 3" to 6" of compacted material such as sand or gravel is the recommended material because of its drainage characteristics. The compacted material should be leveled so the top of the box is flush to grade.
BACKFILLING Place selected backfill into the excavation at 12" lifts and compact. The backfill should be discontinued approximately 8" below the finish grade. The final 8" of the excavation should be finished with concrete. This should be accomplished by providing a form around the enclosure that would produce a 8" wide collar (see sketch).
Note: Minimum concrete collar strength is 3,000 psi.
QUIK-SPECIFICATION QUICK-SPECIFICATION
Oldcastle Precast ®
Enclosure Solutions
Madera 801 S. Pine St. Madera, California 93637
Roseville 9600 Antelope Oaks Court, Suite D Roseville, California 95747
Tracy 10304 Linne Road Tracy, California 95377
Portland 11402 NE Markx Street Portland OR 97220
Underground enclosures shall be manufactured by Oldcastle/Christy. Boxes and covers shall be concrete and have a pedestrian rated minimum vertical test load of 350 pounds per square foot. The concrete shall test to a minimum of 4500 psi compressive strength.