Connectors

Report 2 Downloads 130 Views
Color-Keyed

®

EZ Ground™ Connectors MEETS

Figure 6 Compression Ground Tap Connector

IEEE

®

837 REQUIREMENTS

®

H

MAIN

TAP

T

Material : high conductivity copper. Acceptable for direct burial.

Application Cat. No.

54900 54895 54890 54885 54875 54865CK 54860 54855

Tap

Main

Tap

250 kcmil - 500 kcmil or e” - f” ROD 250 kcmil - 500 kcmil or e” - f” ROD 250 kcmil - 500 kcmil or e” - f” ROD 250 kcmil - 500 kcmil or e” - f” ROD #6 SOL - #2 STR 1/0 STR - 250 kcmil or d” - e” ROD 1/0 STR - 250 kcmil or d” - e” ROD 1/0 STR - 250 kcmil or d” - e” ROD

350 kcmil - 500 kcmil 3/0 STR - 250 kcmil 1/0 STR - 2/0 STR #4 SOL - #2 STR #6 SOL - #2 STR 3/0 STR - 250 kcmil 1/0 STR - 2/0 STR #4 SOL - #2 STR

#5 REBAR e” THRU f” #6 REBAR #5 REBAR e” THRU f” #6 REBAR #5 REBAR e” THRU f” #6 REBAR _ _

350 kcmil - 500 kcmil 3/0 STR - 250 kcmil 1/0 STR - 2/0 STR _ _

#3 REBAR c” THRU d” #4 REBAR #3 REBAR c” THRU d” #4 REBAR #3 REBAR c” THRU d” #4 REBAR

3/0 STR - 250 kcmil 1/0 STR - 2/0 STR #2 STR

Cat. No.

H

T

Dies for T&B 14- and 15-Ton Tools *

54900

2k”

1c”

15G121R

3

U1011

3

54895

2i”

f”

15G126R

1

PU998

1

54890

2a”

f”

15G126R

1

PU998

1

54885

1n”

f”

15G126R

1

PU998

1

54875 54865CK 54860 54855

2l” 2i” 1O” 1n”

f” f” f” f”

15501A 15G86R 15G86R 15G86R

1 1 1 1

UO 997 997 997

1 1 1 1

Use 15500TB adapter for T&B 15-ton tool.

96

Cable to Rebar Application

Main

Y750

*

Burndy Tools and Dies Y45 *

S1011 PU996 or S998 PU996 or S998 PU996 or S998 UO U997 U997 U997

3 1 1 1 1 1 1 1 1 1 1

Y46

P1011 PU996 or S998 PU996 or S998 PU996 or S998 UO U997 U997 U997

*

3 1 1 1 1 1 1 1 1 1 1

* = Number of crimps

Color-Keyed

®

EZ Ground™ Connectors MEETS

Figure 8 Compression for Copper Ground Rod Tap Connectors

IEEE

837 REQUIREMENTS

®

B H A

g” T

B Cable Range

GR1-300500†

1”

300-500 kcmil

2W”

15G121R

GR34-300500

f”

300-500 kcmil

2k”

GR58-300500

e”

300-500 kcmil

GR1-40250

1”

3/0 AWG-250 kcmil

H

Dies for T&B * 14- and 15-Ton Tools

Burndy Tools and Dies Y45 *

Y750

*

2

15G121R

2 2

U1011 U1011

2

or

2a”

15G121R

2

PU998

1

or

2k”

15G121R

2

U1011

2 or

GR34-40250

f”

3/0 AWG-250 kcmil

2i”

15G121R

2

PU998

1

or

GR58-40250

e”

3/0 AWG-250 kcmil

2a”

15G121R

2

PU998

1

or

GR12-40250

d”

3/0 AWG-250 kcmil

1n”

15G121R

2

PU998

1

or

GR1-202

1”

2 AWG-2/0 AWG

2l”

15G121R

2

U1011

2 or

GR34-202

f”

2 AWG-2/0 AWG

2i”

15G121R

2

PU998

1

or

GR58-202

e”

2 AWG-2/0 AWG

1O”

15G121R

2

PU998

1

or

GR12-202

d”

2 AWG-2/0 AWG

1n”

15G121R

2

PU998

1

or

S1011 S1012 PU998 S1012 PU998 S1011 S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998 S1011 S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998

2 2 1 2 1 2 2 1 2 1 2 1 2 1 2 2 1 2 1 2 1 2 1

Material: high conductivity copper; acceptable for direct burial. Optional ground rod knurling die for TBM 14- and 15-ton tools: 15500KD58 for e” Ground rod. 15500KD34 for f” Ground rod. Use 15500TB adapter for T&B 15-ton tool. Optional ground rod knurling tool: 240-31565-94 † Use 15-ton tool only.

Y46

GROUNDING CONNECTORS

A Ground Rod

Cat No.

*

P1011 P1011 or PU998 P1011 or PU998

2 2 1 2 1

P1011 or PU998

2 1

P1011 or PU998 P1011 or PU998 P1011 or PU998

2 1 2 1 2 1

P1011 or PU998

2 1

P1011 or PU998 P1011 or PU998 P1011 or PU998

2 1 2 1 2 1

* = Number of crimps

Figure 8 Compression for Steel Ground Rod Cat No.

A Ground Rod

B Cable Range

H

Dies for T&B * 14- and 15-Ton Tools

Y750

*

GR34-300500TP

f”

300-500 kcmil

2k”

15G121R

2

U1011

2

GR58-300500TP

e”

300-500 kcmil

2a”

15G121R

2

PU998

1

GR34-40250TP

f”

3/0 AWG-250 kcmil

2i”

15G121R

2

PU998

1

GR58-40250TP

e”

3/0 AWG-250 kcmil

2a”

15G121R

2

PU998

1

GR12-40250TP

d”

3/0 AWG-250 kcmil

1n”

15G121R

2

PU998

1

GR34-202TP

f”

2 AWG-2/0 AWG

2i”

15G121R

2

PU998

1

GR58-202TP

e”

2 AWG-2/0 AWG

1O”

15G121R

2

PU998

1

GR12-202TP

d”

2 AWG-2/0 AWG

1n”

15G121R

2

PU998

1

Same specifications as above with additional high conductivity tin plating.

Burndy Tools and Dies Y45 * or or or or or or or or

S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998 S1012 PU998

2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1

or or or or or or or or

Y46 P1011 PU998 P1011 PU998 P1011 PU998 P1011 PU998 P1011 PU998 P1011 PU998 P1011 PU998 P1011 PU998

* 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1

* = Number of crimps

97

Color-Keyed

®

EZ Ground™ Connectors Figure 6 to 6 Compression Ground Grid Connectors

MEETS

IEEE

®

837 REQUIREMENTS

®

ELEMENT A

T-T D

2 1/2"

ELEMENT B

T 2 1/2"

Material : high conductivity copper. Acceptable for direct burial.

Cat. No.

54900L 54895L 54885L 54875L 54865L 54855L

Element A Cable

250 kcmil - 500 kcmil #2 STR - 250 kcmil #6 SOL - #2 STR #2 STR - 250 kcmil #6 SOL - #2 STR #6 SOL - #2 STR

Element B to Cable

Element B to Ground Rod

Element B to Rebar

250 kcmil - 500 kcmil 250 kcmil - 500 kcmil 250 kcmil - 500 kcmil #2 STR - 250 kcmil #1 STR - 250 kcmil #6 SOL - #2 STR

e” - f” ROD e” - f” ROD e” - f” ROD d” - e” ROD d” - e” ROD _

e” - f” #5 - #6 REBAR e” - f” #5 - #6 REBAR e” - f” #5 - #6 REBAR c” - d” #3 - #4 REBAR c” - d” #3 - #4 REBAR _

Dies for T&B 14- and 15-Ton Tools Cat. No.

Element A *

Element B *

54900L 54895L

15G121R 3 15G86R 1

15G121R 3 15G126R 1

54885L

15501A 1

15G126R 1

54875L 54865L 54855L

15G86R 1 15501A 1 15501A 1

15G86R 1 15G86R 1 15501A 1

Use 15500TB adapter for T&B 15-ton tool.

98

U1011 PU998 or PU998 PU998 or PU998 U997 U997 U-0

*

3 1 1 1 1 1 1 1

f” d” j” d” j” j”

T

T-T

1a” f” f” f” f” f”

1a” f” f” f” f” f”

Burndy Tools and Dies Y45

Y750 A

D

B

*

U1011 3 U997 1 U-0 or PU998 U997 U-0 U-0

1 1 1 1 1

A

*

B

Y46 *

A

*

B

*

S1011 S998 or PU998 S998

3 1 1 1

S1011 3 U997 1

P1011 3 P998 1

P1011 3 U997 1

U-0 1

P998 1

U-0 1

U997 U997 U-0

1 1 1

U997 1 U-0 1 U-0 1

U997 1 U997 1 U-0 1

U997 1 U-0 1 U-0 1

* = Number of crimps

Color-Keyed

®

EZ Ground™ Connectors MEETS

IEEE

Figure 6 to 8 Compression Ground Rod to Grid Connectors

®

837 REQUIREMENTS

®

ELEMENT A 7/8" L

D

ELEMENT B

GROUNDING CONNECTORS

3/4" L

Material : high conductivity copper. Acceptable for direct burial. Cat. no.

A Copper Bond Ground Rod

B Cable range

D

L

1” f” f” e” e” d” d”

2 AWG - 250 kcmil 250 kcmil - 500 kcmil 2 AWG - 250 kcmil 250 kcmil - 500 kcmil 2 AWG - 250 kcmil 250 kcmil - 500 kcmil 2 AWG - 250 kcmil

d” d” d” j” j” j” j”

2e” 2e” 2e” 2d” 2d” 2d” 2d”

54910LR100 54900LR34 54875LR34 54895LR58 54865LR58 54885LR12 54855LR12

Cat. no.

A Copper Bond Ground Rod

B Cable range

D

L

f” f” e” e” d” d”

250 kcmil - 500 kcmil 2 AWG - 250 kcmil 250 kcmil - 500 kcmil 2 AWG - 250 kcmil 250 kcmil - 500 kcmil 2 AWG - 250 kcmil

d” d” j” j” j” j”

2e” 2e” 2d” 2d” 2d” 2d”

54900LR34TP 54875LR34TP 54895LR58TP 54865LR58TP 54885LR12TP 54855LR12TP

Dies for T&B 14- and 15-Ton Tools Cat. No.

Element A *

Element B *

54920LR100

15G121R 2

15G126R 1

54910LR100

15G121R 2

15G86R 1

54900LR34 & TP

15G121R 2

15G126R 1

54875LR34 & TP

15G121R 2

15G86R 1

54895LR58 & TP

15G121R 2

15G126R 1

54865LR58 & TP

15G121R 2

15G86R 1

54885LR12 & TP

15G121R 2

15G126R 1

54855LR12 & TP

15G121R 2

15G86R 0

Burndy Tools and Dies Y45

Y750 A

U1011 or PU998 U1011 or PU998 U1011 or PU998 U1011 or PU998 U1011 or PU998 U1011 or PU998 U1011 or PU998 U1011 or PU998

*

2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1

B

*

U1011 2 or PU998 1 U997 1 U1011 2 or PU998 1 U997 1 U1011 2 or PU998 1 U997 1 U1011 2 or PU998 1 U997 1

A

S1011 or PU998 S1011 or PU998 S1011 or PU998 S1011 or PU998 S1011 or PU998 S1011 or PU998 S1011 or PU998 S1011 or PU998

B

*

2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1

Y46 *

U1011 2 or PU998 1 U997 1 U1011 2 or PU998 1 U997 1 S998 1 or PU998 1 U997 1 S998 1 or PU998 1

Optional ground rod knurling die for TBM14- and 15-ton tools: 15500KD58 for e” Ground rod. 15500KD34 for f” Ground rod. Use 15500TB adapter for T&B 15-ton tool. Optional ground rod knurling tool: 240-31565-94

U997 1

A

P1011 or PU998 P1011 or PU998 P1011 or PU998 P1011 or PU998 P1011 or PU998 P1011 or PU998 P1011 or PU998 P1011 or PU998

*

2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1

B

*

U1011 2 or PU998 1 U997 1 U1011 2 or PU998 1 U997 1 P998 1 or PU998 1 U997 1 P998 1 or PU998 1 U997 1

* = Number of crimps

99

Color-Keyed

®

EZ Ground™ Connectors MEETS

IEEE

C-Taps Cat. No.

CTP500500 CTP500250 CTP50020 CTP250250 CTP25020 CTP2020 CTP202 CTP22††

837 REQUIREMENTS

® ®

A Cable range

B Cable range

H

L

300 - 500 kcmil 300 - 500 kcmil 300 - 500 Kcmil 3/0 STR - 250 kcmil 3/0 STR - 250 kcmil 1 STR - 2/0 STR 1 STR - 2/0 STR 6 SOL - 2 STR

300 - 500 kcmil 3/0 STR - 250 kcmil 6 SOL - 2/0 STR 3/0 STR - 250 kcmil 1 STR - 2/0 STR 1 STR - 2/0 STR 6 SOL - 2/0 STR 6 SOL - 2/0 STR

2C” 2W” 2k” 2h” 1O” 1l” 1u” 1q”

1a” g” g” g” f” f” f” f”

Material : high conductivity copper. Acceptable for direct burial. Cat No.

CTP500500 CTP500250 CTP50020 CTP250250 CTP25020 CTP2020 CTP202 CTP22††

H

Dies for T&B 14- and 15-Ton Tools †

15G121R 15G121R 15G121R 15G86R 15G86R 15501A 15501A HBKC

*

3 2 2 1 1 1 1 1

Y750

*

U1011 U1011 U1011 U997 U997 U-0 U-0 U-C

3 2 2 1 1 1 1 1

Burndy Tools and Dies Y35 *

S1011 S1011 S1011 U997 U997 U-0 U-0 U-C

3 2 2 1 1 1 1 1

Y46

*

P1011 P1011 P1011 U997 U997 U-0 U-0 U-C

3 2 2 1 1 1 1 1

Cat. No. 15500TB adapter required if using T&B 15-ton tool with 155XX series dies. #6 AWG branch must be doubled. * = Number of crimps



††

L

100

Color-Keyed

®

EZ Ground™ Connectors Copper C-Crimps††

®

H

Material : high conductivity copper; acceptable for direct burial.

BC48 BC46-BB 6 SOL.-4 STR. BC44 BC24 2 SOL.-2 STR. BC22 BC202 . BC2020-BB 1/0 STR.-2/0 STR BC402 BC4020 3/0 STR.-4/0 STR. BC4040

Die Index

Tap

8 SOL.-8 STR. 6 SOL.-6 STR 4 SOL.-4 STR. 8 SOL.-4 STR. 2 SOL.-2 STR. 8 SOL.-2 STR. 1/0 STR.-2/0 STR. 6 SOL.-2 STR. 1/0 STR.-2/0 STR. 3/0 STR.-4/0 STR.

I f J

/64

63

H

G

BG or e

f

C

1Y 1j 1X

n

1e

1h

E or O F or D3

Manual

BY31 BY31 BY31 BY33 BY33 N/A N/A N/A N/A N/A

Does not meet IEE837

††

T&B Blackburn Dies Hydraulic *

1 1 1 1 1

B58CS B58CS B58CS HBKC HBKC HO or 15501A HO or 15501A HD or 15502 HD or 15502 HD or 15502

GROUNDING CONNECTORS

Cat. No.

Wire combinations Dimension L

Main

*

1 1 1 1 1 2 2 2 2 2

* = Number of crimps

®

C-Taps — Small Size

Fig. 1

®

Fig. 2

Fig. 3

Fig. 4

Installing Die Colour Cat. No.

Figure No.

Main

Branch

L

H

for T&B Tools

54705 54710

4 1

j” k”

Red Blue

1

l”

e”

Grey

54720

2

1q”

W”

Brown

54725

2

1q”

m”

Green

54730

2

1 q”

B”

Pink

54735

3

h”

g”

Black

54740

3

1W”

O”

Orange

54745

3

1W”

1h”

Purple

54750

3

14 or 16 10 or 12 10,12 8,10,12 8,10,12 6,8 6,8,10,12 6,5 6,8,10,12 5 3 4,5,6,8,10,12 4,5 3,4 4,5,6,8,10,12 3,4 2,3 3,4,5,6,8,10,12 2,3 1,2 2,3,4,5,6,8,10,12 1,2 1/0,1

j” l”

54715

12 or 14 10 or 8 6 8 4 or 5 6 3 4 or 5 2 3 4 1 2 3 1/0 1 2 2/0 1/0 1 3/0 2/0 1/0

1W”

1i”

Yellow

101