CONSTANT PRESSURE PUMP SYSTEMS
QuickPAK now available with either SubDrive or MonoDrive.
Constant Pressure All-in-One Package: The SubDrive QuickPAK is an all-in-one package with an extended warranty available on the pump, motor and drive and Franklin’s commitment to quality, availability, service, innovation and value. The SubDrive QuickPAK includes:
The 3-Wire QuickPAK featuring MonoDrive includes:
n Franklin pump
n Franklin pump
n Franklin motor
n Franklin motor
n SubDrive variable frequency controller
n MonoDrive variable frequency controller
n Pressure sensor
n Pressure sensor
Learn more about how we handle the pressure at constantpressure.com.
Key Features: SubDrive QuickPAK is Franklin’s popular system solution package, designed to simplify the installation of a constant pressure system. n Motor, pump and drive in one package n Selection based on flow and total dynamic head n NEMA
1 and NEMA 4 drive enclosures available
n Extended
warranty available on QuickPAK components
n Soft start feature prevents water hammer and increases motor life n Works
with small or large pressure tanks, even works with an existing tank
n Smart Reset® technology allows well recovery before restarting the pump n Excellent radio frequency interference shielding The SubDrive QuickPAK includes:
The 3-Wire QuickPAK featuring MonoDrive includes:
of flow rates available in: 7, 10, 25, 35, 60 and 90 gpm
n Variety of flow rates available in: 5, 7, 10, 15, 20 and 25 gpm
n Flexible power inputs featuring single-phase input power with three-phase motor performance, using 1.5 - 3 hp motors
n Single-phase input power with single-phase motor performance, using 1/2 - 2 hp motors
Applications:
Built-in Diagnostics and Protection:
n Residential Water Systems - City-like water pressure - Smaller tank saves space
The SubDrive QuickPAK products include diagnostic features and built-in protection from potentially harmful conditions. n Surge n Short circuit n n Overheated controller Underload n Undervoltage n Locked pump n Open circuit
n Variety
n Landscape Irrigation Systems - Even distribution of water in zones - Eliminates need for separate system n Water Treatment Systems - More efficient back flushing - Eliminates need for multiple pumps n Geothermal
Systems Pressure Boosting - Ability to pump from a cistern or holding tank n Constant
Ordering Information Contents: SubDrive QuickPAK Ordering & Performance....................................................... 1 3-Wire QuickPAK Ordering & Performance............................................................ 23
Model Number Description:
XX SD QP - X.XHP Motor Horsepower: 1/2, 3/4, 1.0, 1.5, 2.0 or 3.0 hp QuickPAK SD = SubDrive, 3W = MonoDrive Pump Flow: 5, 7, 10, 15, 20, 25, 35, 60 or 90 gpm
SubDrive NEMA 1 Enclosure: QuickPAK Order No.
Model Number
SubDrive GPM
Drive Type
Pump GPM Design Hydraulics
Motor
Part No.
HP
Part No.
HP
Part No.
93800775
7SDQP-1.5HP
7
SD75
5870203380
3/4
7
SS
Noryl
92470812
1.5
23451492S
93800770
7SDQP-2.0HP
7
SD100
5870204100
1
7
SS
Tri-Seal
93870710
2
23431592S
93800715
7SDQP-3.0HP
7
SD150
5870204150
1.5
7
SS
Noryl
92470820
3
23431626
93801001
10SDQP-1.5HP
10
SD75
5870203380
3/4
10
SS
Tri-Seal
93871007
1.5
23451492S
93801060
10SDQP-2.0HP
10
SD100
5870204100
1
10
SS
Tri-Seal
93871010
2
23431592S
93801003
10SDQP-3.0HP
10
SD150
5870204150
2
10
SS
Tri-Seal
93871020
3
23431626
93801501
15SDQP-1.5HP
15
SD75
5870203380
3/4
15
SS
Tri-Seal
93871507
1.5
23451492S
93801510
15SDQP-2.0HP
15
SD100
5870204100
1
15
SS
Tri-Seal
93871510
2
23431592S
93801503
15SDQP-3.0HP
15
SD150
5870204150
1.5
15
SS
Tri-Seal
93871515
3
23431626
93802001
20SDQP-1.5HP
20
SD75
5870203380
1
20
SS
Tri-Seal
93872010
1.5
23451492S
93802030
20SDQP-2.0HP
20
SD100
5870204100
1
20
SS
Tri-Seal
93872010
2
23431592S
93802003
20SDQP-3.0HP
20
SD150
5870204150
2
20
SS
Tri-Seal
93872020
3
23431626
93802501
25SDQP-1.5HP
25
SD75
5870203380
1
25
SS
Tri-Seal
93872510
1.5
23451492S
93802525
25SDQP-2.0HP
25
SD100
5870204100
1
25
SS
Tri-Seal
93872510
2
23431592S
93802503
25SDQP-3.0HP
25
SD150
5870204150
1.5
25
SS
Tri-Seal
93872515
3
23431626
93803575(a)
35SDQP-1.5HP
35
SD75
5870203380
1
35
SS
Noryl
93873510
1.5
23451492S
93803510
(a)
35SDQP-2.0HP
35
SD100
5870204100
1
35
SS
Noryl
93873510
2
23431592S
93803515
(a)
35SDQP-3.0HP
35
SD150
5870204150
1.5
35
SS
Noryl
93873515
3
23431626
93806015(a)
60SDQP-3.0HP
60
SD150
5870204150
2
60
SS
Noryl
93876020
3
23431626
93809015(a)
90SDQP-3.0HP
90
SD150
5870204150
2
90
SS
Noryl
93879020
3
23431626
NOTE: (a) High capacity pumps, 35 gpm and higher, in a QuickPAK are not supplied with an internal check valve.
1
SubDrive NEMA 4 Enclosure: QuickPAK Order No.
Model Number
SubDrive GPM
Drive Type
Pump
Part No.
HP
5870203384
Motor
GPM Design Hydraulics
Part No.
HP
Part No.
93800760
7SDQP-1.5HP-N4
7
SD75-N4
3/4
7
SS
Noryl
92470812
1.5
23451492S
93800772
7SDQP-2.0HP-N4
7
SD100-N4 5870204104
1
7
SS
Tri-Seal
93870710
2
23431592S
93800710
7SDQP-3.0HP-N4
7
SD150-N4 5870204154
1.5
7
SS
Noryl
92470820
3
23431626
93801002
10SDQP-1.5HP-N4
10
SD75-N4
3/4
10
SS
Tri-Seal
93871007
1.5
23451492S
93801062
10SDQP-2.0HP-N4
10
SD100-N4 5870204104
1
10
SS
Tri-Seal
93871010
2
23431592S
93801004
10SDQP-3.0HP-N4
10
SD150-N4 5870204154
2
10
SS
Tri-Seal
93871020
3
23431626
93801502
15SDQP-1.5HP-N4
15
SD75-N4
3/4
15
SS
Tri-Seal
93871507
1.5
23451492S
93801511
15SDQP-2.0HP-N4
15
SD100-N4 5870204104
1
15
SS
Tri-Seal
93871510
2
23431592S
93801504
15SDQP-3.0HP-N4
15
SD150-N4 5870204154
1.5
15
SS
Tri-Seal
93871515
3
23431626
93802002
20SDQP-1.5HP-N4
20
SD75-N4
5870203384
1
20
SS
Tri-Seal
93872010
1.5
23451492S
93802036
20SDQP-2.0HP-N4
20
SD100-N4 5870204104
1
20
SS
Tri-Seal
93872010
2
23431592S
93802004
20SDQP-3.0HP-N4
20
SD150-N4 5870204154
2
20
SS
Tri-Seal
93872020
3
23431626
93802502
25SDQP-1.5HP-N4
25
SD75-N4
5870203384
1
25
SS
Tri-Seal
93872510
1.5
23451492S
93802530
25SDQP-2.0HP-N4
25
SD100-N4 5870204104
1
25
SS
Tri-Seal
93872510
2
23431592S
93802504
25SDQP-3.0HP-N4
25
SD150-N4 5870204154
1.5
25
SS
Tri-Seal
93872515
3
23431626
93803514
5870203384
5870203384
35SDQP-1.5HP-N4
35
SD75-N4
5870203384
1
35
SS
Noryl
93873510
1.5
23451492S
93803520(a) 35SDQP-2.0HP-N4
35
SD100-N4 5870204104
1
35
SS
Noryl
93873510
2
23431592S
(a)
93803528
(a)
35SDQP-3.0HP-N4
35
SD150-N4 5870204154
1.5
35
SS
Noryl
93873515
3
23431626
93806016
(a)
60SDQP-3.0HP-N4
60
SD150-N4 5870204154
2
60
SS
Noryl
93876020
3
23431626
93809010(a) 90SDQP-3.0HP-N4
90
SD150-N4 5870204154
2
90
SS
Noryl
93879020
3
23431626
Maximum Motor Cable Length (in Feet) Controller Model
140 °F / 60 °C Insulation - AWG copper wire size
Franklin Motor Model
HP
14
12
10
8
6
4
3
SubDrive75
234514XXXX
1.5
420
670
1060
1670
-
-
-
SubDrive100
234315XXXX
2
320
510
810
1280
2010
-
-
SubDrive150
234316XXXX
3
240
390
620
990
1540
-
-
NOTE: (a) High capacity pumps, 35 gpm and higher, in a QuickPAK are not supplied with an internal check valve.
2
Pump Performance 7SDQP-1.5HP SD75, 7 gpm - 3/4 hp Pump End, 1.5 hp Motor 700
80
600
Hz
Pe
rfo
rm
an
ce
400 Recommended Operating Range
300
200 20 FT
TOTAL HEAD (FT)
500
1.0 GPM
100 30 Hz
Perfo
rman
ce
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 160 Shut-off psi
20
13 12 10 273
40
60
80
100
13 12 12 10 264
13 12 12 11 9 256
13 12 12 11 11 9 247
12 12 11 11 10 8 238
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 350 12 12 13 11 12 11 13 11 10 12 11 10 13 12 10 9 13 12 11 10 8 13 12 12 10 9 8 13 12 12 11 10 8 7 12 12 12 11 11 9 8 7 12 11 11 10 10 9 7 6 11 11 10 10 9 8 7 5 11 10 10 9 9 7 6 3 10 10 9 9 8 7 5 10 9 8 8 8 6 3 8 7 7 6 5 230 221 212 204 195 173 152 130
400 11 11 10 10 9 8 8 7 7 6 4
450 10 9 9 8 8 7 6 6 4
500 9 8 8 7 6 5 4
550 7 7 6 5 4
600 6 5 3
108
87
65
43
22
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
3
7SDQP-2.0HP SD100, 7 gpm - 1.0 hp Pump End, 2.0 hp Motor 1000 900 80
800
Hz
Pe
rfo
rm
TOTAL HEAD (FT)
700
an
ce
600 500 Recommended Operating Range
400 300
25 FT
200 1.0 GPM
100
30 Hz
Perfo
rman
ce
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 300 350 400 450 500 13 12 12 11 11 13 12 12 11 11 10 13 12 12 11 11 10 13 13 12 11 11 10 10 13 13 12 12 11 11 10 9 13 13 13 12 12 11 10 10 9 13 13 13 12 12 11 11 10 9 9 13 13 12 12 12 12 11 10 10 9 8 13 13 12 12 12 12 11 11 10 9 9 8 13 13 12 12 12 12 12 11 10 10 9 8 7 13 13 13 12 12 12 12 12 11 11 10 9 9 8 7 13 13 13 12 12 12 12 12 11 11 10 10 9 8 7 6 13 13 12 12 12 12 11 11 11 11 10 9 9 8 7 6 12 12 12 12 12 11 11 11 11 11 10 9 8 7 7 5 12 12 12 12 11 11 11 11 10 10 10 9 8 7 6 5 12 12 12 11 11 11 11 10 10 10 9 8 8 7 5 4 11 11 11 11 10 10 10 9 9 9 8 7 6 5 4 382 373 365 356 347 339 330 321 313 304 282 261 239 217 196 174 20
40
60
80
550 600 650 700 750 800 850 10 9 8 7 7 5 4 10 9 8 7 6 5 3 9 8 8 7 5 4 3 9 8 7 6 5 4 8 8 7 6 4 3 8 7 6 5 4 8 7 6 4 3 7 6 5 4 7 6 5 3 6 5 4 6 5 3 5 4 5 3 4 3 3 3 153 131 109
88
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
4
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
66
44
23
Pump Performance 7SDQP-3.0HP SD150, 7 gpm - 1.5 hp Pump End, 3.0 hp Motor 1200 1100 80
1000
Hz
Pe
rfo
rm
an
900
ce
TOTAL HEAD (FT)
800 700 600
Recommended Operating Range
500 400 300 25 FT
200 30 Hz
100
Perfo
1.0 GPM
rman
ce
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 3 90 100 110 120 130 140 150 160 Shut-off psi
160
13 404
180
13 396
200
12 387
250
300
13 13 12 365
13 12 12 12 11 344
Depth to Pumping Water Level, or Lift (in feet) 400 450 500 550 600 650 700 750 800 12 12 11 11 10 13 12 12 11 10 9 13 12 11 11 10 9 13 12 12 11 10 9 9 13 12 11 11 10 9 8 12 12 11 10 9 9 8 13 12 11 11 10 9 8 7 12 12 11 10 10 9 8 7 13 12 11 11 10 9 8 8 7 12 12 11 10 10 9 8 7 6 13 12 11 11 10 9 8 8 7 6 12 12 11 10 10 9 8 7 6 5 12 12 11 10 9 8 8 7 6 4 12 11 11 10 9 8 7 6 5 12 11 10 9 8 8 7 6 4 11 11 10 9 8 7 6 5 10 9 9 8 7 6 4 322 300 279 257 235 214 192 170 149 127 350
850 9 8 8 8 7 7 7 6 5 5 3
900 8 8 7 7 7 6 5 4 3
950 1000 1050 7 6 5 7 6 4 6 5 6 4 5 3 4 3
106
84
62
41
19
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
5
10SDQP-1.5HP SD75, 10 gpm - 3/4 hp Pump End, 1.5 hp Motor 600
500 80
Hz
Pe
rfo
rm
an
ce
300 Recommended Operating Range
200 20 FT
TOTAL HEAD (FT)
400
1.0 GPM
100 30 Hz
Perfo
rman
ce
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 160 Shut-off psi
20
17 17 16 15 15 14 13 12 12 11 8 244
40
17 17 16 15 15 14 13 12 12 11 10 7 235
60
80
100
17 17 16 15 15 14 13 13 12 11 10 9 6 226
17 17 16 15 15 14 13 13 12 11 10 9 8 5 218
17 17 16 16 15 14 14 13 12 11 10 10 9 8 4 209
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 17 17 16 15 13 17 16 16 15 14 12 17 16 16 15 15 13 11 16 16 15 15 14 12 11 16 15 15 14 13 12 10 15 14 14 13 13 11 9 14 14 13 12 12 10 8 14 13 12 12 11 9 7 13 12 12 11 10 8 6 12 11 11 10 9 7 5 11 11 10 9 8 6 10 10 9 8 7 5 10 9 8 7 6 4 9 8 7 6 5 8 7 6 5 4 7 6 5 4 200
192
183
174
166
144
122
350 11 11 10 9 8 7 6 5
400 10 9 8 7 6 4
450 7 6 5 4
500 5 4
101
79
57
36
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
6
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 10SDQP-2.0HP SD100, 10 gpm - 1.0 hp Pump End, 2.0 hp Motor 800 700
80
Hz
Pe
rfo
rm
600
an
ce
TOTAL HEAD (FT)
500 400 Recommended Operating Range
300
25 FT
200 1.0 GPM
100 30 Hz
Perfo
rman
ce
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 300 350 400 450 500 550 600 650 700 750 17 16 15 14 13 11 10 9 8 4 17 16 16 15 13 12 11 10 9 7 17 16 15 14 13 12 10 10 8 5 16 16 15 14 12 11 10 9 7 17 16 15 14 13 12 11 10 8 5 17 17 17 16 15 14 12 11 10 9 7 17 17 17 16 15 14 13 12 11 10 8 5 17 17 16 16 16 15 14 12 11 10 9 7 17 17 16 16 16 16 14 13 12 11 10 9 6 17 17 16 16 16 15 15 14 13 11 10 9 8 17 17 16 16 16 15 15 15 13 12 11 10 9 6 17 17 17 16 16 16 15 15 14 14 13 11 10 9 8 4 17 17 16 16 16 15 15 14 14 13 12 11 10 9 6 16 16 16 16 15 15 14 14 13 13 11 10 9 8 4 16 16 16 15 15 14 14 13 13 12 11 10 9 7 16 15 15 15 14 14 13 13 12 12 10 10 8 5 14 14 13 13 12 12 11 11 10 10 9 7 324 315 306 298 289 280 272 263 254 246 224 202 181 159 137 116 94 72 51 29 8 20
40
60
80
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
7
10SDQP-3.0HP SD150, 10 gpm - 2.0 hp Pump End, 3.0 hp Motor 1200 1100 1000 900
70
TOTAL HEAD (FT)
800
Hz
Pe
rfo
rm
an
ce
700 600 500
Recommended Operating Range
400 300
30 Hz
100
25 FT
200 Perfo
1.0 GPM
rman
ce
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 3 90 100 110 120 130 140 150 160 Shut-off psi
20
40
60
17 17 17 16 16 15 490
17 17 17 16 16 16 15 481
17 17 17 16 16 16 16 15 472
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180 200 250 300 350 400 450 500 550 600 650 17 16 16 15 14 13 13 12 17 17 16 15 15 14 13 12 11 17 16 16 15 14 14 13 12 11 17 17 16 15 15 14 13 12 12 11 17 17 16 16 15 14 14 13 12 11 10 17 17 17 16 15 15 14 13 12 12 11 10 17 17 17 17 16 16 15 14 14 13 12 11 10 9 17 17 17 17 16 16 15 15 14 13 12 12 11 10 9 17 17 17 17 16 16 16 15 14 14 13 12 11 10 9 8 17 17 17 16 16 16 16 15 14 13 13 12 11 10 9 8 17 17 16 16 16 15 15 15 14 13 12 11 10 9 8 7 17 16 16 16 15 15 15 14 13 13 12 11 10 9 8 7 16 16 16 15 15 15 15 14 13 12 11 10 10 9 8 6 16 16 15 15 15 15 14 13 13 12 11 10 9 8 7 6 16 15 15 15 14 14 14 13 12 11 11 10 9 8 6 5 15 15 15 14 14 14 14 13 12 11 10 9 8 7 6 5 14 14 14 13 13 13 12 12 11 10 9 8 7 5 4 464 455 446 438 429 420 412 390 368 347 325 303 282 260 238 217
700 11 11 10 10 9 9 8 8 7 7 6 6 5 5 4
750 10 10 9 9 8 8 7 7 6 6 5 4 4
800 9 9 8 8 7 7 6 6 5 4 4
850 8 8 7 7 6 5 5 4 4
195 173 152 130 108 87
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
8
900 950 1000 7 6 5 6 5 4 6 5 5 4 5 4 4
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
65
Pump Performance 15SDQP-1.5HP SD75, 15 gpm - 3/4 hp Pump End, 1.5 hp Motor 450 400 80
350
Hz
Pe
rfo
rm
an
ce
TOTAL HEAD (FT)
300 250 200
Recommended Operating Range
150
25 FT
100 1.0 GPM
50
30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 Shut-off psi
20
24 23 21 20 19 17 15 14 12 10 180
40
24 23 21 20 19 17 16 14 12 10 8 172
60
80
24 23 22 20 19 17 16 14 12 10 8
24 23 22 21 19 18 16 14 13 11 9 6
163
154
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 24 23 22 19 24 23 22 21 20 17 24 23 22 21 20 19 15 23 22 21 20 19 17 14 22 21 20 18 17 16 12 21 20 18 17 16 14 10 19 18 17 15 14 12 8 18 16 15 14 12 10 16 15 13 12 10 8 15 13 12 10 8 13 11 9 7 11 9 7 9 7 6
146
137
128
120
111
102
81
300 15 14 12 10 7
350 11 9 7
400 6
59
37
16
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
9
15SDQP-2.0HP SD100, 15 gpm - 1.0 hp Pump End, 2.0 hp Motor 600
500
80
Hz
Pe
rfo
rm
an
ce
300 Recommended Operating Range
200 20 FT
TOTAL HEAD (FT)
400
1.0 GPM
100 30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
20
24 23 23 22 21 20 19 15 248
40
24 24 23 22 21 20 19 18 14 239
60
80
100
24 24 23 22 21 20 19 18 16 13 231
24 24 23 22 21 20 19 18 17 15 12 222
24 24 23 22 21 20 19 18 17 16 14 10 213
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 23 22 24 23 21 24 24 22 20 24 23 23 21 18 24 23 23 22 20 17 24 23 23 22 21 19 16 23 22 22 21 20 17 15 22 22 21 20 19 16 14 21 21 20 19 18 15 12 20 19 18 17 16 14 11 19 18 17 16 15 12 9 18 17 16 15 14 11 6 17 16 15 14 13 9 16 15 14 13 11 7 15 13 12 11 10 13 12 11 9 7 8 6 205 196 187 179 170 148 127
350 19 18 17 16 15 13 12 10 8 6
400 17 16 14 13 12 10 8
450 14 13 12 10 8
500 11 10 7
550 7
105
83
62
40
18
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
10
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 15SDQP-3.0HP SD150, 15 gpm - 1.5 hp Pump End, 3.0 hp Motor 900 800 700
80
TOTAL HEAD (FT)
600
Hz
Pe
rfo
rm
an
ce
500 400
Recommended Operating Range
300
25 FT
200 100
1.0 GPM
30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 3 90 100 110 120 130 140 150 160 Shut-off psi
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 300 350 400 450 500 550 600 650 700 750 23 22 21 19 17 15 14 11 9 6 24 23 21 20 18 16 15 13 10 8 24 22 21 19 17 16 14 12 9 6 24 23 22 20 18 17 15 13 11 8 24 24 22 21 19 18 16 14 12 9 6 24 24 23 22 20 19 17 15 13 11 8 24 24 24 23 22 21 19 18 16 14 12 10 7 24 24 23 23 22 22 20 19 17 15 13 11 8 24 24 23 23 22 22 21 20 18 16 14 12 10 7 24 24 23 23 22 22 21 20 19 17 15 13 11 9 24 24 23 23 22 22 21 20 20 18 16 14 12 10 7 24 24 23 23 22 21 21 20 20 19 17 15 13 11 9 6 24 23 23 22 21 21 20 19 19 18 16 14 12 10 7 23 22 22 21 21 20 19 19 18 17 15 14 11 9 6 22 22 21 21 20 19 19 18 17 16 15 13 10 8 22 21 20 20 19 19 18 17 16 16 14 12 9 6 20 19 18 17 17 16 15 15 14 13 11 8 344 335 326 318 309 300 292 283 274 266 244 222 201 179 158 136 114 93 71 49 28 20
40
60
80
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
11
20SDQP-1.5HP SD75, 20 gpm - 1.0 hp Pump End, 1.5 hp Motor 400
70
300
Hz
Pe
rfo
rm
an
200 20 FT
TOTAL HEAD (FT)
ce
Recommended Operating Range 1.0 GPM
100
30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
35
40
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 Shut-off psi
20
33 31 30 29 27 25 23 21 18 16 14 11 7 159
40
33 32 30 29 27 26 23 21 19 17 14 12 8 150
60 34 32 31 29 28 26 24 21 19 17 15 12 8
141
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180 34 32 31 30 29 27 32 31 30 29 27 25 31 30 28 27 25 23 29 28 27 25 23 21 28 26 25 23 21 19 26 24 22 20 18 17 24 22 20 18 16 14 22 20 18 16 14 12 19 18 16 14 11 7 17 15 13 11 7 15 13 10 13 10 9
133
124
115
107
98
89
200 26 23 21 19 17 15 12 8
250 21 19 16 14 11 7
300 16 14 11
81
59
38
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
12
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 20SDQP-2.0HP SD100, 20 gpm - 1.0 hp Pump End, 2.0 hp Motor 500
TOTAL HEAD (FT)
400
80
Hz
Pe
rfo
rm
an
ce
300
Recommended Operating Range
200
20 FT
100 30 Hz
Perfo
1.0 GPM
rman
ce
0 5
10
15
20
25
30
35
40
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
20
35 33 31 30 29 28 26 24 22 19 7 188
40
60
80
33 32 31 29 28 26 24 22 20 17
33 32 31 30 28 26 24 22 20 18 14
33 32 31 30 28 27 25 23 20 18 15 10
179
171
162
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 35 33 32 29 34 32 31 31 28 34 32 31 30 29 26 34 32 31 30 29 28 24 32 31 30 29 28 26 22 31 30 29 28 26 24 20 30 29 27 26 24 22 17 29 27 25 24 22 20 13 27 25 23 22 20 17 8 25 23 21 19 17 14 23 21 19 17 13 9 21 19 16 13 8 18 16 12 7 15 11 11
153
145
136
127
119
110
88
300 26 24 21 19 16 13
350 21 19 16 12
400 15 11
67
45
23
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
13
20SDQP-3.0HP SD150, 20 gpm - 2.0 hp Pump End, 3.0 hp Motor 700
600
70
Hz
Pe
rfo
an
ce
400 Recommended Operating Range
300
200 20 FT
TOTAL HEAD (FT)
500
rm
1.0 GPM
100
30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
35
40
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 3 90 100 110 120 130 140 150 160 Shut-off psi
20
35 33 33 32 31 30 29 29 27 26 22 278
40
35 34 33 32 31 30 30 29 28 26 25 21 269
60
80
100
34 33 32 31 31 30 29 28 27 25 24 20 260
34 33 32 31 31 30 29 28 27 25 24 23 19 252
34 33 32 31 31 30 29 28 27 26 24 23 22 18 243
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 350 35 34 33 31 29 27 35 33 33 32 30 28 26 34 33 33 32 31 30 27 25 33 32 32 31 31 29 26 23 32 32 31 30 30 27 25 22 32 31 30 30 29 26 24 21 31 30 29 29 28 25 22 20 30 29 28 28 26 24 21 19 29 28 27 26 25 23 20 17 28 27 26 25 24 21 19 16 27 26 25 24 23 20 18 14 26 25 24 23 22 19 16 12 25 23 22 21 20 18 15 23 22 21 20 19 17 12 22 21 20 19 18 15 21 20 19 18 17 13 17 16 15 13 11 234 226 217 208 200 178 156 135
400 24 23 22 21 20 19 17 16 14 12
450 22 21 19 18 17 16 14 11
500 19 18 17 15 13 11
550 17 15 13 10
600 13
113
91
70
48
26
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
14
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 25SDQP-1.5HP SD75, 25 gpm - 1.0 hp Pump End, 1.5 hp Motor 350
300 70
250
Hz
Pe
rfo
rm
an
200
150
Recommended Operating Range
100 10 FT
TOTAL HEAD (FT)
ce
1.0 GPM
50
30 H
z Pe
rform
ance
0 5
10
15
20
25
30
35
40
45
FLOW (GPM) HP
PSI
0 10 20 30 40 50 1.5 60 70 80 90 100 110 Shut-off psi
20
40
38 36 35 33 30 27 24 21 18 135
39 36 35 33 31 28 25 21 18 14 126
60 39 37 35 33 31 28 25 22 19 15 117
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 39 37 36 34 33 37 36 34 32 30 35 34 32 30 27 34 32 29 27 24 31 29 26 24 21 29 26 23 20 17 25 23 20 17 22 19 16 19 16 15
109
100
92
83
74
180 30 28 24 21 18 14
200 28 25 22 18 14
250 21 18
66
57
35
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
15
25SDQP-2.0HP SD100, 25 gpm - 1.0 hp Pump End, 2.0 hp Motor 400 80
350
Hz
Pe
rfo
rm
an
ce
300
TOTAL HEAD (FT)
250 200
Recommended Operating Range
150
10 FT
100 1.0 GPM
50
30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
35
40
45
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 2 80 90 100 110 120 130 140 150 Shut-off psi
20
39 36 35 34 31 28 25 23 20 14 158
40
60
40 36 35 34 32 29 26 23 20 15
37 35 34 32 29 26 23 21 16
149
141
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180 200 39 36 35 38 36 35 34 38 36 35 34 32 37 36 35 34 31 29 37 36 35 33 31 29 26 36 35 33 31 28 26 23 34 33 30 28 25 23 21 32 30 27 25 23 20 16 30 27 25 22 20 15 27 24 22 19 24 22 18 21 18 17
132
123
115
106
98
89
80
250 31 28 25 23 20 14
300 25 23 19
350 19
59
37
15
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
16
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 25SDQP-3.0HP SD150, 25 gpm - 1.5 hp Pump End, 3.0 hp Motor 600
500 80
Pe
rfo
rm
an
ce
300 Recommended Operating Range
200 20 FT
TOTAL HEAD (FT)
400
Hz
1.0 GPM
100 30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
35
40
45
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 3 90 100 110 120 130 140 150 160 Shut-off psi
20
37 36 35 34 32 29 27 20 210
40
60
38 36 35 34 32 30 27 25 18 201
38 36 35 34 32 30 28 25 23 14 193
38 37 35 34 33 30 28 26 23 21
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 36 38 35 38 36 34 40 37 36 35 32 39 37 36 35 34 30 39 37 36 35 34 32 27 37 36 35 33 32 30 25 36 35 33 32 30 28 23 34 33 31 29 27 25 21 33 31 29 27 25 23 18 31 29 27 25 23 21 28 26 24 23 21 18 26 24 22 20 18 14 24 22 20 17 22 20 17 19 16
184
175
80
167
158
149
141
132
110
300 33 31 29 27 24 22 20 17
350 29 26 24 22 20 16
400 24 22 19 16
450 19 15
89
67
46
24
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
17
35SDQP-1.5HP SD75, 35 gpm - 1.0 hp Pump End, 1.5 hp Motor 250
200
70
Hz
Pe
rfo
rm
an
150
Recommended Operating Range
100
10 FT
TOTAL HEAD (FT)
ce
1.0 GPM
50 30 H
z Pe
rform
ance
0 5
10
15
20
25
30
35
40
45
50
55
60
65
FLOW (GPM) HP
PSI
0 10 20 30 1.5 40 50 60 70 80 Shut-off psi
20
53 47 41 36 30 25 20 101
40 54 47 42 37 31 26 21 15 92
60
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160
180
200
55 48 43 37 32 27 22 16
49 43 38 33 27 22 17
44 39 33 28 23 18
40 34 29 24 18
35 29 24 19
30 25 20
26 21
21 15
83
75
66
57
49
40
31
23
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
18
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 35SDQP-2.0HP SD100, 35 gpm - 1.0 hp Pump End, 2.0 hp Motor 300
250
80
Hz
Pe
rfo
rm
an
ce
150 Recommended Operating Range
100 10 FT
TOTAL HEAD (FT)
200
1.0 GPM
50 30 Hz
Perfo
rman
ce
0 5
10
15
20
25
30
35
40
45
50
55
60
65
FLOW (GPM) HP
PSI
0 10 20 30 40 50 2 60 70 80 90 100 110 Shut-off psi
20
54 50 46 41 35 30 25 18 120
40
50 46 42 36 31 26 20 111
60
51 47 42 37 31 26 21
103
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160
51 47 43 38 32 27 22
94
180
200
250
52 48 44 38 33 28 22
53 48 44 39 33 28 23 15
49 45 40 34 29 24 16
46 41 35 30 25 18
41 36 30 26 19
36 31 26 20
25 19
85
77
68
59
51
42
20
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
19
35SDQP-3.0HP SD150, 35 gpm - 1.5 hp Pump End, 3.0 hp Motor 400 350 80
300
Hz
Pe
rfo
rm
an
ce
TOTAL HEAD (FT)
250 200 Recommended Operating Range
150
10 FT
100 1.0 GPM
50
30 H
z Per
form
ance
0 5
10
15
20
25
30
35
40
45
50
55
60
65
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 3 80 90 100 110 120 130 140 Shut-off psi
20
60 58 56 54 51 47 44 40 35 31 28 24 19 161
40
60
60 58 56 54 51 48 44 40 36 32 28 24 20
58 56 54 52 48 45 41 37 32 29 25 20 15
152
144
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180 200
250
300
350
58 57 55 52 49 45 41 37 33 29 25 21 16
57 55 52 49 46 42 38 34 30 26 22 17
55 53 50 46 42 38 34 30 26 22 17
53 50 47 43 39 35 31 27 23 18
51 47 43 39 35 31 27 23 19
48 44 40 36 32 28 24 19
44 40 36 32 28 24 20 15
36 32 28 24 19
27 23 19
18
135
126
118
109
101
92
83
62
40
18
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
20
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
Pump Performance 60SDQP-3.0HP SD150, 60 gpm - 2.0 hp Pump End, 3.0 hp Motor 300
250 70
Hz
Pe
rfo
200
rm
an
150 Recommended Operating Range
100 10 FT
TOTAL HEAD (FT)
ce
2.0 GPM
50 30 Hz
Perfo
rman
ce
0 10
20
30
40
50
60
70
80
90
100
FLOW (GPM) HP
PSI
0 10 20 30 40 3 50 60 70 80 90 Shut-off psi
20
87 75 65 57 48 39 31 115
40
89 76 66 58 49 40 32 107
60
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160
180
200
91 78 68 59 50 42 33
93 79 69 60 51 43 34 25
81 70 61 53 44 35 26
72 62 54 45 36 28
64 55 46 38 29
56 47 39 30
49 40 31
41 32
98
89
81
72
63
55
46
37
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
21
90SDQP-3.0HP 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0
70
Hz
Pe
rfo
rm
an
ce
Recommended Operating Range 10 FT
TOTAL HEAD (FT)
SD150, 90 gpm - 2.0 hp Pump End, 3.0 hp Motor
5.0 GPM
30 H
z Pe
rfor
man
ce
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 FLOW (GPM) HP
PSI
0 10 20 3 30 40 50 Shut-off psi
20 150 118 95 74 52 67
Depth to Pumping Water Level, or Lift (in feet) 40 60 80 100 120 121 98 77 55 58
140
125 101 79 58
104 82 61
85 64 41
66 44
48
49
41
32
23
15
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
22
Actual maximum performance of the SubDrive QuickPAK system is power limited by the SubDrive unit. This limit is based on the maximum allowable AMP load of the submersible motor. The result is that in some installations an 80 Hz speed may not be attained.
3-Wire
Ordering Information
MonoDrive NEMA 1 Enclosure: QuickPAK Order No.
Model Number
MonoDrive GPM
Drive Type
Part No.
Pump HP
GPM Design Hydraulics
Motor Part No.
HP
Part No.
93970501
5-3WQP-0.5HP
5
MD
5870203110
1/2
5
SS
Noryl
93870505
1/2 2145059004S
93970503
5-3WQP-0.75HP
5
MD
5870203110
3/4
5
SS
Noryl
93870507
3/4 2145079004S
93970505
5-3WQP-1.0HP
5
MD
5870203110
1
5
SS
Noryl
93870510
93970701
7-3WQP-0.5HP
7
MD
5870203110
1/2
7
SS
Tri-Seal
93870705
1/2 2145059004S
93970703
7-3WQP-0.75HP
7
MD
5870203110
3/4
7
SS
Tri-Seal
93870707
3/4 2145079004S
93970705
7-3WQP-1.0HP
7
MD
5870203110
1
7
SS
Tri-Seal
93870710
93971001
10-3WQP-0.5HP
10
MD
5870203110
1/2
10
SS
Tri-Seal
93871005
1/2 2145059004S
93971003
10-3WQP-0.75HP
10
MD
5870203110
3/4
10
SS
Tri-Seal
93871007
3/4 2145079004S
93971005
10-3WQP-1.0HP
10
MD
5870203110
1
10
SS
Tri-Seal
93871010
93971007
10-3WQP-1.5HP
10
MDXT
5870204110
1.5
10
SS
Tri-Seal
93871015
93971009
10-3WQP-2.0HP
10
MDXT
5870204110
2
10
SS
Tri-Seal
93871020
93971501
15-3WQP-0.5HP
15
MD
5870203110
1/2
15
SS
Tri-Seal
93871505
1/2 2145059004S
93971503
15-3WQP-0.75HP
15
MD
5870203110
3/4
15
SS
Tri-Seal
93871507
3/4 2145079004S
93971505
15-3WQP-1.0HP
15
MD
5870203110
1
15
SS
Tri-Seal
93871510
93971507
15-3WQP-1.5HP
15
MDXT
5870204110
1.5
15
SS
Tri-Seal
93871515
93971509
15-3WQP-2.0HP
15
MDXT
5870204110
2
15
SS
Tri-Seal
93871520
93972003
20-3WQP-0.75HP
20
MD
5870203110
3/4
20
SS
Tri-Seal
93872007
93972005
20-3WQP-1.0HP
20
MD
5870203110
1
20
SS
Tri-Seal
93872010
93972007
20-3WQP-1.5HP
20
MDXT
5870204110
1.5
20
SS
Tri-Seal
93872015
93972009
20-3WQP-2.0HP
20
MDXT
5870204110
2
20
SS
Tri-Seal
93872020
2
2243019204S
93972505
25-3WQP-1.0HP
25
MD
5870203110
1
25
SS
Tri-Seal
93872510
1
2145089003S
93972507
25-3WQP-1.5HP
25
MDXT
5870204110
1.5
25
SS
Tri-Seal
93872515
93972509
25-3WQP-2.0HP
25
MDXT
5870204110
2
25
SS
Tri-Seal
93872525
1
1
1
2145089003S
2145089003S
2145089003S
1.5 2243009203S 2
1
2243019204S
2145089003S
1.5 2243009203S 2
2243019204S
3/4 2145079004S 1
2145089003S
1.5 2243009203S
1.5 2243009203S 2
2243019204S
NOTE: Verify dip switches are set properly. Please refer to the Wiring/Configuration insert or the Quick Installation Guide for dip switch settings.
23
3-Wire MonoDrive NEMA 4 Enclosure: QuickPAK Order No.
Model Number
93970502 5-3WQP-0.5HP-N4
MonoDrive GPM 5
Drive Type MD-N4
Pump
Part No.
HP
5870203114
1/2
GPM Design Hydraulics 5
SS
Noryl
Motor Part No.
HP
Part No.
93870505
1/2 2145059004S 3/4 2145079004S
93970504 5-3WQP-0.75HP-N4
5
MD-N4
5870203114
3/4
5
SS
Noryl
93870507
93970506 5-3WQP-1.0HP-N4
5
MD-N4
5870203114
1
5
SS
Noryl
93870510
93970702 7-3WQP-0.5HP-N4
7
MD-N4
5870203114
1/2
7
SS
Tri-Seal
93870705
1/2 2145059004S 3/4 2145079004S
1
2145089003S
93970704 7-3WQP-0.75HP-N4
7
MD-N4
5870203114
3/4
7
SS
Tri-Seal
93870707
93970706 7-3WQP-1.0HP-N4
7
MD-N4
5870203114
1
7
SS
Tri-Seal
93870710
93971002 10-3WQP-0.5HP-N4
10
MD-N4
5870203114
1/2
10
SS
Tri-Seal
93871005
1/2 2145059004S
93971004 10-3WQP-0.75HP-N4
10
MD-N4
5870203114
3/4
10
SS
Tri-Seal
93871007
3/4 2145079004S
93971006 10-3WQP-1.0HP-N4
10
MD-N4
5870203114
1
10
SS
Tri-Seal
93871010
93971008 10-3WQP-1.5HP-N4
10
MDXT-N4
5870204114
1.5
10
SS
Tri-Seal
93871015
93971010 10-3WQP-2.0HP-N4
10
MDXT-N4
5870204114
2
10
SS
Tri-Seal
93871020
1
1
2145089003S
2145089003S
1.5 2243009203S 2
2243019204S
93971502 15-3WQP-0.5HP-N4
15
MD-N4
5870203114
1/2
15
SS
Tri-Seal
93871505
1/2 2145059004S
93971504 15-3WQP-0.75HP-N4
15
MD-N4
5870203114
3/4
15
SS
Tri-Seal
93871507
3/4 2145079004S
93971506 15-3WQP-1.0HP-N4
15
MD-N4
5870203114
1
15
SS
Tri-Seal
93871510
93971508 15-3WQP-1.5HP-N4
15
MDXT-N4
5870204114
1.5
15
SS
Tri-Seal
93871515
93971510 15-3WQP-2.0HP-N4
15
MDXT-N4
5870204114
2
15
SS
Tri-Seal
93871520
93972004 20-3WQP-0.75HP-N4
20
MD-N4
5870203114
3/4
20
SS
Tri-Seal
93872007
93972006 20-3WQP-1.0HP-N4
20
MD-N4
5870203114
1
20
SS
Tri-Seal
93872010
1
2145089003S
1.5 2243009203S 2
2243019204S
3/4 2145079004S 1
2145089003S
93972008 20-3WQP-1.5HP-N4
20
MDXT-N4
5870204114
1.5
20
SS
Tri-Seal
93872015
93972010 20-3WQP-2.0HP-N4
20
MDXT-N4
5870204114
2
20
SS
Tri-Seal
93872020
1.5 2243009203S 2
2243019204S
93972506 25-3WQP-1.0HP-N4
25
MD-N4
5870203114
1
25
SS
Tri-Seal
93872510
1
2145089003S
93972508 25-3WQP-1.5HP-N4
25
MDXT-N4
5870204114
1.5
25
SS
Tri-Seal
93872515
93972510 25-3WQP-2.0HP-N4
25
MDXT-N4
5870204114
2
25
SS
Tri-Seal
93872525
1.5 2243009203S 2
NOTE: Verify dip switches are set properly. Please refer to the Wiring/Configuration insert or the Quick Installation Guide for dip switch settings.
24
2243019204S
Pump Performance 5-3WQP-0.5HP MonoDrive, 5 gpm - 1/2 hp Pump End, 1/2 hp Motor 400 350 60
300
Hz
Pe
rfo
rm
an
TOTAL HEAD (FT)
ce
250 200
Recommended Operating Range
150
30 H
10 FT
100 z Pe
50
1.0 GPM
rform
ance
0 1
2
3
4
5
6
7
8
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1/2 80 90 100 110 120 130 140 150 Shut-off psi
20
7.2 6.7 6.2 5.8 5.3 4.7 4.2 3.7 3.2 2.6 1.6 160
40
7.3 6.8 6.3 5.8 5.3 4.8 4.3 3.8 3.3 2.7 1.8 0.3 151
60
7.4 6.8 6.4 5.9 5.4 4.9 4.4 3.9 3.4 2.8 1.9 0.5 143
80
7.5 6.9 6.4 6.0 5.5 5.0 4.4 3.9 3.4 2.9 2.1 0.8
134
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 7.1 6.7 6.3 7.0 6.6 6.2 5.8 7.0 6.5 6.2 5.7 5.3 6.5 6.1 5.7 5.2 4.8 6.0 5.6 5.2 4.7 4.3 5.5 5.1 4.6 4.2 3.8 5.0 4.6 4.1 3.7 3.3 4.5 4.1 3.6 3.2 2.6 4.0 3.6 3.1 2.5 1.7 3.5 3.0 2.4 1.5 0.2 2.9 2.3 1.4 2.2 1.2 1.0
125
117
108
100
91
200 5.9 5.4 4.9 4.3 3.8 3.3 2.7 1.9 0.4
250 4.8 4.3 3.8 3.2 2.6 1.7 0.1
300 3.7 3.1 2.5 1.5
350 2.3 1.2
82
61
39
17
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
25
3-Wire 5-3WQP-0.75HP MonoDrive, 5 gpm - 3/4 hp Pump End, 3/4 hp Motor 600 550 500 60
TOTAL HEAD (FT)
450
Hz
Pe
rfo
400
rm
an
ce
350 300 Recommended Operating Range
250 200
100
30 H
z Pe
10 FT
150 rform
ance
50
1.0 GPM
0 1
2
3
4
5
6
7
8
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 3/4 80 90 100 110 120 130 140 150 160 Shut-off psi
20
7.2 6.9 6.6 6.2 5.9 5.5 5.2 4.8 3.5 231
40
7.3 6.9 6.6 6.3 5.9 5.6 5.2 4.8 4.4 3.1 222
60
80
100
7.3 7.0 6.7 6.3 6.0 5.6 5.3 4.9 4.5 4.1 2.7 214
7.4 7.0 6.7 6.4 6.0 5.7 5.3 4.9 4.5 4.1 3.7 2.2 205
7.5 7.1 6.7 6.4 6.1 5.7 5.4 5.0 4.6 4.2 3.8 3.3 1.6 196
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 7.3 6.6 5.9 7.3 7.0 6.3 5.5 7.2 6.9 6.6 5.9 5.1 7.5 7.2 6.9 6.6 6.3 5.6 4.7 7.1 6.8 6.6 6.3 6.0 5.2 4.3 6.8 6.5 6.2 5.9 5.6 4.8 3.9 6.5 6.2 5.9 5.6 5.2 4.4 3.5 6.1 5.8 5.5 5.2 4.9 4.0 3.0 5.8 5.5 5.1 4.8 4.5 3.6 2.5 5.4 5.1 4.8 4.4 4.1 3.1 1.8 5.0 4.7 4.4 4.0 3.6 2.6 1.0 4.6 4.3 3.9 3.6 3.2 2.0 4.2 3.9 3.5 3.1 2.7 1.2 3.8 3.5 3.0 2.6 2.1 0.2 3.4 3.0 2.5 2.0 1.3 2.9 2.4 1.9 1.2 0.4 0.8 188 179 170 162 153 132 110
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
26
350 5.1 4.7 4.3 3.8 3.4 2.9 2.4 1.7 0.9
400 4.2 3.8 3.3 2.8 2.3 1.6 0.7
450 3.3 2.8 2.2 1.5 0.6
500 2.1 1.3 0.4
550 0.2
88
67
45
23
2
Pump Performance 5-3WQP-1.0HP MonoDrive, 5 gpm - 1.0 hp Pump End, 1.0 hp Motor 650 600 550 60
500
Hz
Pe
rfo
rm
TOTAL HEAD (FT)
450
an
ce
400 350 Recommended Operating Range
300 250 200 150
z Pe
rform
ance
10 FT
30 H
100 50
1.0 GPM
0 1
2
3
4
5
6
7
8
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 1 90 100 110 120 130 140 150 160 Shut-off psi
20
7.2 6.9 6.6 6.3 6.0 5.7 4.6 266
40
7.3 7.0 6.7 6.4 6.1 5.8 5.4 4.3 257
60
80
100
7.3 7.0 6.7 6.4 6.1 5.8 5.5 5.1 4.0 248
7.4 7.0 6.7 6.5 6.2 5.8 5.5 5.2 4.8 3.7 240
7.4 7.1 6.8 6.5 6.2 5.9 5.6 5.2 4.8 4.5 3.3 231
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 350 7.2 6.6 5.9 6.9 6.3 5.6 7.3 6.6 6.0 5.3 7.3 7.0 6.3 5.7 4.9 7.2 6.9 6.7 6.0 5.3 4.5 7.5 7.2 6.9 6.6 6.4 5.7 5.0 4.2 7.1 6.9 6.6 6.4 6.1 5.4 4.6 3.8 6.8 6.6 6.3 6.1 5.8 5.0 4.2 3.4 6.5 6.3 6.0 5.7 5.4 4.7 3.9 3.0 6.2 6.0 5.7 5.4 5.1 4.3 3.5 2.5 5.9 5.6 5.3 5.0 4.7 3.9 3.1 2.0 5.6 5.3 5.0 4.7 4.3 3.5 2.6 1.3 5.3 4.9 4.6 4.3 4.0 3.1 2.1 0.4 4.9 4.6 4.2 3.9 3.6 2.7 1.4 4.5 4.2 3.9 3.5 3.2 2.2 0.6 4.1 3.8 3.5 3.2 2.8 1.6 3.0 2.6 2.1 1.6 0.9 222 214 205 196 188 166 145 123
400 5.2 4.8 4.5 4.1 3.7 3.3 2.9 2.5 1.9 1.2 0.2
450 4.4 4.0 3.7 3.3 2.9 2.4 1.8 1.0
500 3.6 3.2 2.8 2.3 1.7 0.9
550 2.7 2.2 1.6 0.7
600 1.4 0.6
101
80
58
36
15
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
27
3-Wire 7-3WQP-0.5HP MonoDrive, 7 gpm - 1/2 hp Pump End, 1/2 hp Motor 350
300 60
TOTAL HEAD (FT)
250
Hz
Pe
rfo
rm
an
ce
200 Recommended Operating Range
150
10 FT
100 1.0 GPM
50
30 H
z Pe
rform
ance
0 1
2
3
4
5
6
7
8
9
10
11
FLOW (GPM) HP
PSI
0 10 20 30 40 50 1/2 60 70 80 90 100 110 120 Shut-off psi
20
9.8 9.2 8.4 7.7 6.9 6.0 4.8 3.2 1.1 125
40
9.9 9.3 8.5 7.8 7.0 6.1 5.0 3.4 1.4 116
60
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180
10.0 9.4 8.6 7.9 7.1 6.3 5.2 3.7 1.7
9.5 8.7 8.0 7.2 6.4 5.3 3.9 2.0
108
99
200
250
300
9.0 8.3 7.5 6.8 5.8 4.5 2.8 0.6
8.4 7.6 6.9 5.9 4.7 3.1 0.9
7.7 7.0 6.1 4.9 3.3 1.2
7.1 6.2 5.1 3.6 1.5
4.9 3.3 1.2
0.8
9.6 8.8 8.1 7.3 6.5 5.5 4.1 2.3
9.7 8.9 8.2 7.4 6.6 5.7 4.3 2.5 0.3
90
82
73
64
56
47
25
4
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
28
Pump Performance 7-3WQP-0.75HP MonoDrive, 7 gpm - 3/4 hp Pump End, 3/4 hp Motor 450 400 60
350
Hz
Pe
rfo
rm
TOTAL HEAD (FT)
300
an
ce
250 Recommended Operating Range
200 150
30 H
10 FT
100 z Pe
50
1.0 GPM
rform
ance
0 1
2
3
4
5
6
7
8
9
10
11
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 3/4 80 90 100 110 120 130 140 150 Shut-off psi
20
9.7 9.3 8.9 8.4 7.9 7.4 6.8 6.1 5.3 4.3 180
40
60
80
9.8 9.4 8.9 8.5 8.0 7.4 6.8 6.2 5.4 4.4 3.3 171
9.8 9.4 9.0 8.5 8.0 7.5 6.9 6.3 5.5 4.6 3.5 2.1 163
9.9 9.5 9.1 8.6 8.1 7.6 7.0 6.4 5.6 4.7 3.6 2.3 0.8 154
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 9.7 9.3 9.0 9.7 9.3 8.9 8.5 9.9 9.6 9.2 8.8 8.4 8.0 9.5 9.2 8.8 8.4 7.9 7.5 9.1 8.7 8.3 7.9 7.4 6.9 8.7 8.2 7.8 7.3 6.8 6.2 8.2 7.7 7.3 6.7 6.1 5.4 7.7 7.2 6.6 6.0 5.3 4.5 7.1 6.5 5.9 5.2 4.4 3.4 6.4 5.8 5.1 4.2 3.2 2.1 5.7 5.0 4.1 3.1 1.9 0.4 4.8 3.9 2.9 1.6 0.2 3.8 2.7 1.4 2.5 1.2 1.0 145
137
128
119
111
102
250 7.9 7.4 6.8 6.1 5.3 4.3 3.2 1.8 0.1
300 6.7 6.0 5.1 4.2 3.0 1.5
350 5.0 4.0 2.8 1.3
400 2.5 1.0
81
59
37
16
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
29
3-Wire 7-3WQP-1.0HP MonoDrive, 7 gpm - 1.0 hp Pump End, 1.0 hp Motor 600 550 500 60
450
Hz
Pe
rfo
rm
TOTAL HEAD (FT)
400
an
ce
350 300 Recommended Operating Range
250 200 10 FT
150 100
1.0 GPM
30 H
z Pe
rform
ance
50 0 1
2
3
4
5
6
7
8
9
10
11
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 1 90 100 110 120 130 140 150 160 Shut-off psi
20
9.8 9.5 9.2 8.9 8.6 8.3 7.9 7.5 7.1 5.3 235
40
9.8 9.5 9.2 8.9 8.6 8.3 8.0 7.6 7.2 6.7 4.6 227
60
80
100
9.9 9.6 9.3 9.0 8.7 8.3 8.0 7.6 7.2 6.7 6.2 3.9 218
9.9 9.6 9.3 9.0 8.7 8.4 8.1 7.7 7.3 6.8 6.2 5.6 3.0 209
9.9 9.7 9.4 9.1 8.7 8.4 8.1 7.7 7.3 6.9 6.3 5.7 4.9 2.2 201
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 9.8 9.6 8.9 8.2 9.8 9.5 9.3 8.6 7.9 10.0 9.7 9.5 9.2 9.0 8.3 7.5 9.7 9.4 9.2 8.9 8.6 7.9 7.0 9.4 9.1 8.9 8.6 8.3 7.6 6.5 9.1 8.8 8.6 8.3 8.0 7.1 5.9 8.8 8.5 8.2 7.9 7.6 6.6 5.2 8.5 8.2 7.9 7.6 7.2 6.0 4.4 8.2 7.8 7.5 7.1 6.7 5.3 3.5 7.8 7.5 7.1 6.6 6.1 4.5 2.5 7.4 7.0 6.6 6.0 5.5 3.7 1.5 6.9 6.5 6.0 5.4 4.7 2.7 0.5 6.4 5.9 5.3 4.6 3.8 1.7 5.8 5.2 4.5 3.7 2.9 0.7 5.1 4.3 3.6 2.7 1.8 4.2 3.4 2.6 1.7 0.8 1.3 0.4 192 183 175 166 157 136 114
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
30
350 7.4 7.0 6.4 5.8 5.1 4.3 3.3 2.4 1.3 0.3
400 6.3 5.7 5.0 4.1 3.2 2.2 1.2 0.2
450 4.8 4.0 3.0 2.0 1.0
500 2.9 1.9 0.8
550 0.7
92
71
49
28
6
Pump Performance 10-3WQP-0.5HP MonoDrive, 10 gpm - 1/2 hp Pump End, 1/2 hp Motor 280 260 240 220
TOTAL HEAD (FT)
200
60
180
Hz
Pe
rfo
rm
an
160
ce
140 Recommended Operating Range
120 100 80
10 FT
60 40
30 H
1.0 GPM
z Pe
rform
20
ance
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 1/2 50 60 70 80 90 100 Shut-off psi
20
13.8 12.5 11.3 9.5 7.5 5.5 3.6 0.8 101
40
60
14.0 12.7 11.5 9.8 7.7 5.8 3.8 1.3
12.8 11.6 10.0 8.0 6.0 4.1 1.7
93
84
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 13.0 11.8 10.3 8.3 6.3 4.4 2.1
75
180
200
250
13.1 12.0 10.5 8.6 6.5 4.6 2.5
12.2 10.7 8.8 6.8 4.9 2.8
10.9 9.1 7.1 5.1 3.1
9.4 7.3 5.4 3.4 0.6
7.6 5.6 3.7 1.1
5.9 4.0 1.5
1.0
67
58
49
41
32
23
2
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
31
3-Wire 10-3WQP-0.75HP MonoDrive, 10 gpm - 3/4 hp Pump End, 3/4 hp Motor 350
300 60
Hz
TOTAL HEAD (FT)
250
Pe
rfo
rm
an
ce
200 Recommended Operating Range
150
10 FT
100 1.0 GPM
30 H
z Pe
50
rform
ance
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 3/4 70 80 90 100 110 120 130 140 Shut-off psi
20
13.8 13.0 12.4 11.6 10.7 9.5 8.1 6.6 5.0 3.2 0.9 142
40
60
14.0 13.1 12.5 11.8 10.8 9.7 8.3 6.8 5.2 3.4 1.2
13.2 12.5 11.9 11.0 9.8 8.5 7.0 5.4 3.7 1.6
133
125
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180
13.3 12.6 12.0 11.1 10.0 8.7 7.2 5.6 3.9 1.9
116
13.4 12.7 12.1 11.2 10.2 8.9 7.4 5.9 4.2 2.2
108
200
250
300
13.5 12.8 12.2 11.4 10.3 9.0 7.6 6.1 4.4 2.5
12.9 12.2 11.5 10.5 9.2 7.8 6.3 4.6 2.8 0.3
12.3 11.6 10.6 9.4 8.0 6.5 4.9 3.0 0.7
11.7 10.8 9.6 8.2 6.7 5.1 3.3 1.1
10.9 9.7 8.4 6.9 5.3 3.6 1.4
8.2 6.7 5.1 3.2 1.0
4.8 2.9 0.5
99
90
82
73
64
43
21
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
32
Pump Performance 10-3WQP-1.0HP MonoDrive, 10 gpm - 1.0 hp Pump End, 1.0 hp Motor 500 450 400 60
TOTAL HEAD (FT)
350
Hz
Pe
rfo
rm
an
ce
300 250 Recommended Operating Range
200 150
30 H
10 FT
100 z Pe
50
rform
1.0 GPM
ance
0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 1 90 100 110 120 130 140 150 160 Shut-off psi
20
13.6 13.1 12.6 12.0 11.5 10.9 10.2 9.4 8.5 7.6 6.5 2.7 196
40
13.7 13.1 12.6 12.1 11.6 10.9 10.3 9.5 8.6 7.7 6.7 5.5 1.3 187
60
80
13.8 13.2 12.7 12.2 11.6 11.0 10.4 9.6 8.8 7.8 6.8 5.7 4.4
13.9 13.3 12.8 12.3 11.7 11.1 10.5 9.7 8.9 7.9 6.9 5.8 4.6 3.3
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 13.5 13.0 12.6 12.1 10.9 14.0 13.4 13.0 12.5 12.1 11.6 10.2 13.4 12.9 12.5 12.0 11.5 11.0 9.4 12.8 12.4 11.9 11.4 10.9 10.3 8.5 12.3 11.9 11.4 10.8 10.2 9.5 7.6 11.8 11.3 10.7 10.1 9.4 8.7 6.6 11.2 10.6 10.0 9.3 8.6 7.8 5.4 10.5 9.9 9.2 8.5 7.6 6.7 4.2 9.8 9.1 8.3 7.5 6.6 5.6 2.8 9.0 8.2 7.4 6.4 5.4 4.4 1.2 8.1 7.2 6.3 5.3 4.2 3.0 7.1 6.1 5.1 4.0 2.8 1.5 6.0 5.0 3.8 2.6 1.2 4.8 3.7 2.4 1.0 3.5 2.2 0.8 2.0 0.6
178
170
161
152
144
135
127
118
96
300 9.3 8.4 7.4 6.4 5.2 3.9 2.5 0.9
350 7.3 6.2 5.0 3.7 2.3 0.6
400 4.8 3.5 2.0 0.3
450 1.7
75
53
31
10
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
33
3-Wire 10-3WQP-1.5HP MonoDrive, 10 gpm - 1.5 hp Pump End, 1.5 hp Motor 650 600 550 500 60
TOTAL HEAD (FT)
450
Hz
Pe
rfo
rm
400
an
ce
350 300 Recommended Operating Range
250 200
10 FT
150 30 H
100
z Pe
1.0 GPM
rform
ance
50 0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 160 Shut-off psi
20
13.9 13.4 13.0 12.7 12.4 12.0 11.6 11.1 10.5 9.8 9.1 6.9 262
40
14.0 13.4 13.0 12.7 12.4 12.1 11.7 11.2 10.6 9.9 9.2 8.5 6.3 254
60
80
100
13.5 13.1 12.8 12.5 12.1 11.7 11.2 10.7 10.0 9.3 8.6 7.8 5.7 245
13.6 13.1 12.8 12.5 12.2 11.8 11.3 10.7 10.1 9.4 8.7 7.9 7.2 5.1 236
13.6 13.2 12.8 12.5 12.2 11.8 11.4 10.8 10.2 9.5 8.8 8.0 7.3 6.6 4.6 228
Depth to Pumping Water Level, or Lift (in feet) 120 140 160 180 200 250 300 350 13.8 13.3 13.0 12.7 12.0 11.0 9.6 13.7 13.3 13.0 12.7 12.4 11.6 10.4 8.9 13.2 12.9 12.7 12.4 12.1 11.1 9.8 8.2 12.9 12.6 12.4 12.0 11.7 10.5 9.0 7.4 12.6 12.3 12.0 11.6 11.2 9.9 8.3 6.7 12.3 11.9 11.6 11.1 10.6 9.2 7.6 6.0 11.9 11.5 11.1 10.5 10.0 8.4 6.8 5.3 11.4 11.0 10.5 9.9 9.3 7.7 6.1 4.7 10.9 10.4 9.8 9.2 8.5 6.9 5.4 4.1 10.3 9.7 9.1 8.4 7.8 6.2 4.8 3.4 9.6 9.0 8.3 7.7 7.1 5.6 4.2 2.6 8.9 8.2 7.6 7.0 6.3 4.9 3.5 1.6 8.1 7.5 6.9 6.3 5.7 4.3 2.7 7.4 6.8 6.2 5.6 5.0 3.6 1.8 6.7 6.1 5.5 4.9 4.4 2.9 0.6 6.0 5.4 4.8 4.3 3.7 2.0 4.0 3.4 2.8 2.0 1.0 219 210 202 193 184 163 141 119
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
34
400 8.1 7.3 6.6 5.9 5.2 4.6 4.0 3.3 2.5 1.4
450 6.5 5.8 5.1 4.5 3.8 3.1 2.3 1.2
500 5.0 4.4 3.7 3.0 2.1 1.0
550 3.6 2.9 2.0 0.8
600 1.8 0.6
98
76
54
33
11
Pump Performance 10-3WQP-2.0HP MonoDrive, 10 gpm - 2.0 hp Pump End, 2.0 hp Motor 750 700 650 600
60
Hz
TOTAL HEAD (FT)
550
Pe
rfo
rm
an
500
ce
450 400 350
Recommended Operating Range
300 250 150
30 H
z Pe
100
25 FT
200 rform
ance
1.0 GPM
50 0 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
20
13.9 13.5 13.2 12.9 12.6 12.2 11.9 11.5 11.2 9.8 313
40
14.0 13.6 13.2 12.9 12.6 12.3 11.9 11.6 11.2 10.8 9.4 305
60
14.0 13.6 13.3 12.9 12.6 12.3 12.0 11.6 11.3 10.9 10.4 8.9 296
80
100
120
13.7 13.3 13.0 12.7 12.4 12.0 11.7 11.3 10.9 10.5 10.0 8.5 287
13.7 13.4 13.0 12.7 12.4 12.1 11.7 11.4 11.0 10.6 10.1 9.6 7.9 279
13.8 13.4 13.1 12.8 12.4 12.1 11.8 11.4 11.0 10.6 10.2 9.7 9.2 7.4 270
Depth to Pumping Water Level, or Lift (in feet) 140 160 180 200 250 300 350 400 13.9 13.6 12.9 12.2 11.4 10.6 13.9 13.5 13.3 12.6 11.9 11.1 10.1 13.8 13.5 13.2 12.9 12.2 11.5 10.6 9.6 13.5 13.2 12.9 12.6 11.9 11.1 10.2 9.1 13.1 12.8 12.6 12.3 11.6 10.7 9.7 8.5 12.8 12.5 12.3 12.0 11.2 10.3 9.2 7.9 12.5 12.2 11.9 11.6 10.8 9.8 8.6 7.3 12.2 11.9 11.6 11.3 10.3 9.3 8.0 6.7 11.8 11.5 11.2 10.8 9.9 8.7 7.4 6.0 11.5 11.1 10.8 10.4 9.4 8.1 6.8 5.3 11.1 10.7 10.4 9.9 8.8 7.5 6.1 4.5 10.7 10.3 9.9 9.4 8.2 6.9 5.4 3.7 10.2 9.8 9.4 8.9 7.6 6.2 4.6 2.9 9.7 9.3 8.8 8.3 7.0 5.5 3.8 2.0 9.2 8.8 8.3 7.7 6.3 4.7 3.0 1.0 8.7 8.2 7.7 7.1 5.6 4.0 2.1 6.8 6.3 5.6 5.0 3.3 1.3 261 253 244 235 214 192 170 149
450 9.5 9.0 8.4 7.8 7.2 6.6 5.9 5.1 4.4 3.6 2.7 1.8 0.8
500 8.3 7.7 7.1 6.4 5.7 5.0 4.2 3.4 2.6 1.6 0.7
550 7.0 6.3 5.6 4.9 4.1 3.3 2.4 1.5 0.5
600 5.5 4.8 4.0 3.1 2.3 1.3 0.3
650 3.8 3.0 2.1 1.2 0.2
700 2.0 1.0
127
106
84
62
41
19
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
35
3-Wire 15-3WQP-0.5HP MonoDrive, 15 gpm - 1/2 hp Pump End, 1/2 hp Motor 200 180 160 60
TOTAL HEAD (FT)
140
Hz
Pe
rfo
rm
an
ce
120 100 Recommended Operating Range
80
5 FT
60 1.0 GPM
40 30 H
z Pe
20
rform
ance
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 1/2 30 40 50 60 Shut-off psi
20
20.3 17.2 14.3 11.9 6.0 69
40
Depth to Pumping Water Level, or Lift (in feet) 60 80 100 120 140
20.2 17.7 14.6 12.4 7.1
18.3 14.9 12.8 8.0 0.4
60
51
160
18.8 15.2 13.1 9.0 1.3
15.6 13.4 9.8 2.3
13.7 10.5 3.4
11.1 4.4
5.5
43
34
25
17
8
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
36
180
Pump Performance 15-3WQP-0.75HP MonoDrive, 15 gpm - 3/4 hp Pump End, 3/4 hp Motor 300
250 60
Pe
rfo
rm
an
ce
150 Recommended Operating Range
100 10 FT
TOTAL HEAD (FT)
200
Hz
1.0 GPM
50
30 H
z Pe
rform
ance
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 3/4 50 60 70 80 90 100 Shut-off psi
20
20.1 19.1 16.8 15.0 13.5 11.5 8.2 3.4 108
40
19.3 17.1 15.2 13.7 11.9 8.7 4.1 99
60
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160
19.6 17.4 15.4 13.9 12.2 9.2 4.8
19.8 17.7 15.7 14.1 12.5 9.7 5.4 0.5
90
82
180
200
250
20.0 18.0 15.9 14.3 12.7 10.2 6.1 1.1
18.3 16.1 14.5 13.0 10.6 6.7 1.7
16.4 14.7 13.2 11.0 7.3 2.4
14.9 13.4 11.4 7.9 3.1
13.6 11.7 8.5 3.8
12.0 9.0 4.4
3.6
73
65
56
47
39
30
8
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
37
3-Wire 15-3WQP-1.0HP MonoDrive, 15 gpm - 1.0 hp Pump End, 1.0 hp Motor 400 350
TOTAL HEAD (FT)
300
60
250
Hz
Pe
rfo
rm
an
ce
200 Recommended Operating Range
150
10 FT
100 1.0 GPM
30 H
z Pe
50
rform
ance
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1 80 90 100 110 120 130 140 Shut-off psi
20
19.8 18.9 17.7 16.4 15.2 14.0 12.4 10.5 7.9 4.8 1.3 144
40
19.9 19.1 17.8 16.6 15.4 14.1 12.7 10.8 8.3 5.3 1.8 135
60
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180
20.0 19.2 18.0 16.8 15.6 14.3 12.9 11.0 8.7 5.7 2.3
19.3 18.2 16.9 15.7 14.5 13.1 11.3 9.0 6.1 2.8
127
118
200
250
300
19.5 18.4 17.1 15.9 14.7 13.3 11.6 9.4 6.6 3.2
19.6 18.5 17.3 16.0 14.8 13.5 11.8 9.7 7.0 3.7 0.2
18.7 17.4 16.2 15.0 13.7 12.1 10.0 7.4 4.2 0.7
17.6 16.4 15.2 13.9 12.3 10.3 7.8 4.6 1.1
16.5 15.3 14.1 12.6 10.6 8.1 5.1 1.6
15.5 14.2 12.8 10.9 8.5 5.5 2.1
12.5 10.6 8.1 5.0 1.5
7.6 4.4 0.9
109
101
92
83
75
66
44
23
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
38
Pump Performance 15-3WQP-1.5HP MonoDrive, 15 gpm - 1.5 hp Pump End, 1.5 hp Motor 500 450 400 60
TOTAL HEAD (FT)
350
Hz
Pe
rfo
rm
an
ce
300 250 Recommended Operating Range
200 150
30 H
z Pe
10 FT
100 rform
50
ance
1.0 GPM
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 160 Shut-off psi
20
40
60
80
20.1 19.9 19.0 17.8 16.5 15.5 14.6 13.8 13.0 12.1 10.8 4.3 198
20.0 20.0 19.1 17.9 16.7 15.6 14.7 13.9 13.1 12.2 11.0 9.3 2.0 190
20.1 19.3 18.1 16.8 15.7 14.8 14.0 13.2 12.3 11.2 9.6 7.5
20.1 19.4 18.3 17.0 15.9 14.9 14.1 13.4 12.5 11.3 9.8 7.8 5.4
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 20.1 19.9 19.1 18.0 15.5 20.1 19.8 18.9 17.8 16.8 14.6 20.1 19.7 18.8 17.7 16.6 15.7 13.8 19.6 18.6 17.5 16.5 15.5 14.7 13.1 18.4 17.3 16.3 15.4 14.6 14.0 12.1 17.2 16.1 15.3 14.5 13.9 13.2 10.8 16.0 15.1 14.4 13.8 13.1 12.3 9.1 15.0 14.3 13.7 13.0 12.1 11.1 7.0 14.2 13.6 12.9 12.0 10.9 9.4 4.4 13.5 12.7 11.8 10.7 9.2 7.4 1.8 12.6 11.7 10.5 8.9 7.0 4.9 11.5 10.3 8.7 6.7 4.5 2.2 10.0 8.4 6.4 4.2 1.8 8.1 6.1 3.8 1.5 5.7 3.4 1.1 3.1 0.8
181
172
164
155
146
138
129
120
99
300 13.7 12.9 11.9 10.6 8.8 6.6 4.0 1.3
350 11.7 10.3 8.5 6.2 3.5 0.9
400 8.1 5.8 3.1 0.5
450 2.7 0.1
77
55
34
12
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
39
3-Wire 15-3WQP-2.0HP MonoDrive, 15 gpm - 2.0 hp Pump End, 2.0 hp Motor 600 550 500 60
TOTAL HEAD (FT)
450
Hz
Pe
rfo
rm
an
ce
400 350 300
Recommended Operating Range
250 200
10 FT
150 100
1.0 GPM
30 H
z Pe
rform
50
ance
0 5
10
15
20
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
20
19.8 19.4 18.7 17.9 17.1 16.3 15.6 14.9 14.2 13.5 10.9 250
40
60
80
19.9 19.4 18.8 18.0 17.2 16.4 15.7 15.0 14.3 13.6 12.8 10.0 241
19.9 19.5 18.9 18.1 17.3 16.5 15.8 15.0 14.4 13.7 12.9 12.1 8.9 232
19.9 19.6 19.0 18.2 17.4 16.6 15.9 15.1 14.4 13.8 13.0 12.2 11.3 7.7 224
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 250 300 20.0 19.8 19.4 18.8 17.1 15.5 20.0 19.8 19.3 18.7 18.1 16.3 14.8 20.0 19.7 19.2 18.6 18.0 17.3 15.6 14.1 19.6 19.1 18.5 17.8 17.1 16.5 14.9 13.4 19.1 18.4 17.7 17.0 16.4 15.7 14.2 12.6 18.3 17.6 16.9 16.3 15.6 15.0 13.5 11.8 17.5 16.8 16.2 15.5 14.9 14.3 12.8 10.8 16.7 16.1 15.4 14.8 14.2 13.6 11.9 9.7 16.0 15.3 14.7 14.1 13.5 12.9 11.0 8.4 15.2 14.6 14.0 13.4 12.8 12.1 9.9 6.9 14.5 13.9 13.3 12.7 12.0 11.2 8.6 5.2 13.8 13.2 12.6 11.8 11.0 10.1 7.1 3.3 13.1 12.5 11.7 10.9 9.9 8.8 5.5 1.4 12.4 11.6 10.7 9.8 8.6 7.4 3.6 11.5 10.6 9.6 8.5 7.2 5.7 1.7 10.5 9.4 8.3 7.0 5.5 3.9 6.3 4.8 3.2 1.5 215 206 198 189 180 172 150 128
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
40
350 14.0 13.3 12.5 11.6 10.6 9.5 8.1 6.6 4.9 3.0 1.1
400 12.4 11.5 10.5 9.3 7.9 6.3 4.6 2.7 0.8
450 10.3 9.1 7.6 6.0 4.3 2.4 0.4
500 7.4 5.8 4.0 2.1 0.1
550 3.7 1.7
107
85
63
42
20
Pump Performance 20-3WQP-0.75HP MonoDrive, 20 gpm - 3/4 hp Pump End, 3/4 hp Motor 200 180
60
Hz
160
Pe
rfo
rm
an
ce
TOTAL HEAD (FT)
140 120 Recommended Operating Range
100 80
5 FT
60 1.0 GPM
40
30 H
z Pe
rform
ance
20 0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 3/4 40 50 60 70 Shut-off psi
20
26.3 23.5 19.4 14.3 7.7 77
40
Depth to Pumping Water Level, or Lift (in feet) 60 80 100 120 140
26.7 23.9 20.0 15.1 8.8
24.3 20.6 15.8 9.8
24.7 21.2 16.4 10.8 0.7
68
60
51
160
180
25.1 21.7 17.1 11.7 2.6
22.3 17.8 12.5 4.3
18.4 13.3 5.8
14.0 7.1
8.3
42
34
25
16
8
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
41
3-Wire 20-3WQP-1.0HP MonoDrive, 20 gpm - 1.0 hp Pump End, 1.0 hp Motor 300
250 60
Hz
Pe
rfo
rm
an
ce
150 Recommended Operating Range
100 10 FT
TOTAL HEAD (FT)
200
1.0 GPM
50
30 H
z Pe
rform
ance
0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 40 50 1 60 70 80 90 100 Shut-off psi
20
26.6 24.8 22.5 19.3 15.7 11.9 7.0 109
40
60
26.9 25.0 22.8 19.8 16.2 12.4 7.8
25.2 23.2 20.2 16.7 13.0 8.5 1.3
101
92
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160
25.5 23.5 20.7 17.2 13.5 9.2 2.6
83
25.7 23.8 21.1 17.7 14.0 9.9 3.7
75
180
200
250
26.0 24.1 21.5 18.2 14.5 10.5 4.8
24.4 21.9 18.7 15.0 11.1 5.7
22.3 19.1 15.5 11.6 6.6
19.6 16.0 12.2 7.4
16.5 12.7 8.2 0.7
7.3
66
57
49
40
31
10
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
42
Pump Performance 20-3WQP-1.5HP MonoDrive, 20 gpm - 1.5 hp Pump End, 1.5 hp Motor 400 350 60
TOTAL HEAD (FT)
300
Hz
Pe
rfo
rm
an
ce
250 200 Recommended Operating Range
150
10 FT
100 30 H
z Pe
50
1.0 GPM
rform
ance
0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 1.5 80 90 100 110 120 130 140 150 Shut-off psi
20
26.1 24.7 23.5 21.7 19.4 16.8 14.4 12.2 10.2 7.8 3.4 155
40
26.3 24.9 23.7 22.0 19.8 17.2 14.7 12.4 10.5 8.2 4.2 147
60
26.6 25.1 23.9 22.3 20.1 17.5 15.0 12.7 10.7 8.5 4.9
138
80
26.9 25.2 24.0 22.5 20.4 17.9 15.3 13.0 11.0 8.9 5.5
129
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 25.8 24.7 23.6 25.6 24.5 23.4 21.9 25.4 24.4 23.2 21.6 19.6 24.2 23.0 21.3 19.3 17.0 22.7 21.0 18.9 16.7 14.5 20.7 18.6 16.3 14.2 12.3 18.2 16.0 13.9 12.1 10.3 15.7 13.6 11.8 10.1 8.0 13.3 11.5 9.8 7.6 3.8 11.3 9.5 7.1 3.0 9.2 6.6 2.1 6.1 1.2 0.1
121
112
103
95
86
200 22.1 19.9 17.4 14.8 12.6 10.6 8.4 4.6
250 17.0 14.5 12.3 10.3 7.9 3.6
300 11.9 9.9 7.4 2.6
350 6.8 1.5
77
56
34
13
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
43
3-Wire 20-3WQP-2.0HP MonoDrive, 20 gpm - 2.0 hp Pump End, 2.0 hp Motor 450 400 60
350
Hz
Pe
rfo
rm
an
ce
250 Recommended Operating Range
200 150 100
30 H
z Pe
10 FT
TOTAL HEAD (FT)
300
rform
50
ance
1.0 GPM
0 5
10
15
20
25
30
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 80 2 90 100 110 120 130 140 150 160 Shut-off psi
20
26.3 25.1 24.3 23.3 21.7 19.8 17.6 15.3 13.2 11.3 2.0 184
40
60
80
26.6 25.3 24.4 23.4 22.0 20.1 17.9 15.6 13.5 11.5 9.5
26.8 25.4 24.5 23.6 22.2 20.3 18.2 15.9 13.8 11.8 9.8 7.4
27.1 25.5 24.6 23.7 22.4 20.6 18.5 16.2 14.0 12.0 10.1 7.8 4.1
175
166
158
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 26.2 25.2 24.5 26.0 25.1 24.4 23.5 25.8 25.0 24.3 23.3 22.1 25.7 24.9 24.1 23.2 21.9 20.2 24.7 24.0 23.0 21.6 19.9 18.0 23.9 22.8 21.4 19.7 17.7 15.8 22.6 21.1 19.4 17.4 15.5 13.6 20.9 19.1 17.1 15.2 13.4 11.7 18.8 16.8 14.9 13.1 11.4 9.7 16.5 14.6 12.8 11.1 9.4 7.2 14.3 12.6 10.9 9.1 6.8 3.2 12.3 10.6 8.8 6.3 2.4 10.4 8.5 5.8 1.7 8.1 5.3 0.8 4.7
149
140
132
123
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
44
114
106
250 21.8 19.9 17.7 15.4 13.3 11.3 9.3 6.7 2.3
300 17.3 15.0 13.0 11.0 9.0 6.1 1.3
350 12.6 10.7 8.6 5.5 0.2
400 8.1 4.8
84
63
41
19
Pump Performance 25-3WQP-1.0HP MonoDrive, 25 gpm - 1.0 hp Pump End, 1.0 hp Motor 250
200
60
Hz
Pe
rm
an
ce
150
Recommended Operating Range
100
10 FT
TOTAL HEAD (FT)
rfo
50
1.0 GPM
30
Hz
Per
form
anc
e
0 5
10
15
20
25
30
35
FLOW (GPM) HP
PSI
0 10 20 30 40 1 50 60 70 80 90 Shut-off psi
20
31.2 29.5 26.9 22.5 18.9 15.6 1.6 90
40
31.8 29.6 27.4 23.1 19.3 16.2 4.9 82
Depth to Pumping Water Level, or Lift (in feet) 60 80 100 120 140 160 32.6 29.8 27.9 23.7 19.7 16.8 7.6
29.9 28.3 24.3 20.1 17.3 9.8
73
65
180
200
30.1 28.6 24.9 20.6 17.7 11.6
28.9 25.5 21.1 18.0 13.1
26.1 21.6 18.4 14.3
22.2 18.7 15.2
19.1 15.9 3.5
16.5 6.4
56
47
39
30
21
13
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
45
3-Wire 25-3WQP-1.5HP MonoDrive, 25 gpm - 1.5 hp Pump End, 1.5 hp Motor 350
300
TOTAL HEAD (FT)
250
60
Hz
Pe
rfo
rm
an
ce
200 Recommended Operating Range
150
10 FT
100 1.0 GPM
30 H
50
z Pe
rform
ance
0 5
10
15
20
25
30
35
FLOW (GPM) HP
PSI
0 10 20 30 40 50 1.5 60 70 80 90 100 110 120 Shut-off psi
20
32.7 30.4 27.6 25.2 23.2 20.9 17.3 11.9 5.4 130
40
32.8 30.8 27.9 25.5 23.5 21.3 17.9 12.7 6.3 0.4 122
60
Depth to Pumping Water Level, or Lift (in feet) 80 100 120 140 160 180
32.8 31.2 28.3 25.8 23.7 21.6 18.4 13.5 7.2 1.0
31.5 28.7 26.1 24.0 21.9 18.9 14.3 8.1 1.7
113
105
31.9 29.1 26.4 24.3 22.2 19.4 15.0 9.0 2.5
96
200
250
300
32.2 29.5 26.7 24.5 22.5 19.9 15.7 9.8 3.3
29.9 27.0 24.8 22.8 20.3 16.4 10.7 4.1
27.4 25.1 23.1 20.7 17.0 11.5 5.0
25.3 23.4 21.1 17.6 12.4 5.9 0.1
23.6 21.4 18.2 13.2 6.8 0.7
17.5 12.2 5.7
4.6
87
79
70
61
53
31
9
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
46
Pump Performance 25-3WQP-2.0HP MonoDrive, 25 gpm - 2.0 hp Pump End, 2.0 hp Motor 450 400
TOTAL HEAD (FT)
350 60
300
Hz
Pe
rfo
rm
an
ce
250 200 Recommended Operating Range
150
10 FT
100 30 H
z Pe
50
1.0 GPM
rform
ance
0 5
10
15
20
25
30
35
FLOW (GPM) HP
PSI
0 10 20 30 40 50 60 70 2 80 90 100 110 120 130 140 150 Shut-off psi
20
32.7 31.2 29.2 27.3 25.7 24.2 22.6 20.6 17.9 14.3 10.0 5.4 167
40
60
32.8 31.4 29.5 27.5 25.9 24.4 22.8 20.9 18.3 14.9 10.6 6.0 2.0 159
32.8 31.7 29.8 27.8 26.1 24.6 23.1 21.2 18.7 15.4 11.2 6.6 2.5 0.1 150
80 32.8 31.9 30.0 28.0 26.3 24.8 23.3 21.5 19.1 15.9 11.8 7.3 3.0 0.3 142
Depth to Pumping Water Level, or Lift (in feet) 100 120 140 160 180 200 32.3 30.8 29.1 27.4 26.0 32.1 30.6 28.8 27.2 25.8 24.5 30.3 28.6 27.0 25.6 24.3 23.0 28.3 26.7 25.4 24.1 22.7 21.1 26.5 25.2 23.9 22.5 20.8 18.5 25.0 23.7 22.3 20.5 18.1 15.1 23.5 22.0 20.2 17.7 14.6 10.9 21.8 19.8 17.3 14.1 10.3 6.4 19.5 16.8 13.5 9.7 5.8 2.3 16.4 13.0 9.1 5.2 1.8 12.4 8.5 4.6 1.4 7.9 4.0 1.1 3.5 0.7 0.5
133
124
116
107
98
90
250 22.7 20.7 18.0 14.5 10.2 5.6 1.7
300 17.5 13.8 9.4 4.9 1.2
350 8.7 4.2 0.8
400 0.5
68
46
25
3
NOTE: Running outside of ‘Recommended Operating Range’ for short periods of time is permissible.
47
400 East Spring Street, Bluffton, Indiana 46714 Tel: 260.824.2900 • Fax: 260.824.2909 www.franklin-electric.com
M5008 03.11