Royal George Theatre Center Cabaret Theatre Technical Data Contact Information

Royal George Theatre Center 1641 N. Halsted St. Chicago, IL 60614

Margaret Cotter, President Liberty Theatres Ph: 212.871.6834 [email protected]

Dan Schlaack, General Manager Ph: 312.988.9105 Fax: 312.988.9554 [email protected]

Thom Van Ermen, Technical Director 312-988-9105 (office) 773-220-3172 (mobile [email protected]

Trish Goggin, Box Office Manager Box Office Main Line: 312.988.9000 Fax: 312.988.4027 [email protected]

General Information Box Office:

6 Outside Lines Ticketmaster/Hot Tix - League of Chicago Theatres, Goldstar Computerized reporting/Reportpro access and record keeping

House:

Wheelchair Accessible Maximum Seating Capacity: 193

Dressing Rooms:

Off Stage Right (2) 3 person dressing rooms, each with make-up mirrors, Make-up lights, outlets Men’s and women’s restrooms, with showers 15 feet down the hall

Production Office: Parking:

Lockable production office Off street parking for 90 cars Garage and Valet operated by Valet Parking Services, Inc..

1

Royal George Theatre Center Cabaret Theatre Technical Data Stage Details Drawings available upon request

***All scenery must fit through a standard 32”x80” door*** Lighting Specifications/Inventory General:

2 P&G house connectors 64 house circuits, 2 P&G jumpers from panel to dimmers dimmers and dimmer power located rear of house

Control Locations:

Control Booth- stage lights, house lights

Power:

(2) 400A, 3phase disconnect for dimmers

Inventory: Control:

-(96) LMI 2.4K dimmers (DMX)- no capacity for extra dimmers - ETC Element 40/250 w/ monitor

Fixtures: -(4) Strand 6x9 (40) FEL -(15) Strand 6x12 (30) FEL -(10) Strand 6x16 (20) FEL -(8) Strand PAR 56 500W WFL -(2) Strand PAR 56 500W MFL -(3) Strand 6” Fresnels 750W BTN Accessories: -(3) 100’ 12 circuit multi with break outs -(4) 50’ 6 circuit multi cables with break outs -assortment of 5’,10’,25’,50’ 2P&G jumpers, two-fers Fixtures are hung by Unistrut attached to concrete ceiling over stage and house

2

Royal George Theatre Center Cabaret Theatre Technical Data Sound Specifications/Inventory FOH mix in rear of house in front of control booth -Soundcraft GB4- 24 channel -24 channels plus 2 stereo channels -4 Pre/Post Auxes, 4 post fade Auxes (8 Auxes total) -4 Groups -7x4 matrix L/R Main and Mono Main House amps, and eq’s, in booth Mic Panels:

SL and SR, snake run from FOH mix to backstage

Inventory: -(4) Crown macro-Tech 1200 amps -(2) Ashly GQX3102 EQ’s -(2) ART HD31 EQ’s -((2) Rane Digital Delays -Snake: (16) XLR sends (4) XLR returns (4) ¼” TRS sends (2) Bose 10” cabinets (12) JBL Control 1 speakers for house fill (2) Bag End Jr. 8” cabinets Assortment of XLR and ¼” TRS cable

Intercom Clear-Com 2 Channel Base Station Clear-Com 501 Belt packs w/ single muff Head set (2) Clear Com 501 Belt Pack w/ Handset (1) Clear-Com Wall mount speaker station (by wardrobe room)

3

Royal George Theatre Center Cabaret Theatre Technical Data